Displaying all 9 publications

Abstract:
Sort:
  1. Prepageran N, Omar R, Raman R
    Ear Nose Throat J, 2005 Sep;84(9):564.
    PMID: 16261756
    Matched MeSH terms: Lighting/instrumentation
  2. Ganandran GS, Mahlia TM, Ong HC, Rismanchi B, Chong WT
    ScientificWorldJournal, 2014;2014:745894.
    PMID: 25133258 DOI: 10.1155/2014/745894
    This paper reports the result of an investigation on the potential energy saving of the lighting systems at selected buildings of the Universiti Tenaga Nasional. The scope of this project includes evaluation of the lighting system in the Library, Admin Building, College of Engineering, College of Information Technology, Apartments, and COE Food court of the university. The main objectives of this project are to design the proper retrofit scenario and to calculate the potential electricity saving, the payback period, and the potential environmental benefits. In this survey the policy for retrofitting the old lighting system with the new energy saving LEDs starts with 10% for the first year and continues constantly for 10 years until all the lighting systems have been replaced. The result of the life cycle analysis reveals that after four years, the selected buildings will bring profit for the investment.
    Matched MeSH terms: Lighting/instrumentation
  3. Azlan CA, Ng KH, Anandan S, Nizam MS
    Australas Phys Eng Sci Med, 2006 Sep;29(3):278-80.
    PMID: 17058591
    Illuminance level in the softcopy image viewing room is a very important factor to optimize productivity in radiological diagnosis. In today's radiological environment, the illuminance measurements are normally done during the quality control procedure and performed annually. Although the room is equipped with dimmer switches, radiologists are not able to decide the level of illuminance according to the standards. The aim of this study is to develop a simple real-time illuminance detector system to assist the radiologists in deciding an adequate illuminance level during radiological image viewing. The system indicates illuminance in a very simple visual form by using light emitting diodes. By employing the device in the viewing room, illuminance level can be monitored and adjusted effectively.
    Matched MeSH terms: Lighting/instrumentation*
  4. Reshak AH, Shahimin MM, Juhari N, Suppiah S
    Prog Biophys Mol Biol, 2013 Nov;113(2):289-94.
    PMID: 24080185 DOI: 10.1016/j.pbiomolbio.2013.09.002
    The potential of organic semiconductor based devices for light generation is demonstrated by the commercialisation of display technologies using organic light emitting diode (OLED). In OLED, organic materials plays an important role of emitting light once the current is passed through. However OLED have drawbacks whereby it suffers from photon loss and exciton quenching. Organic light emitting transistor (OLET) emerged as a new technology to compensate the efficiency and brightness loss encountered in OLED. The structure has combinational capability to switch the electronic signal such as the field effect transistor (FET) as well as to generate light. Different colours of light could be generated by using different types of organic material. The light emission could also be tuned and scanned in OLET. The studies carried out in this paper focuses on investigation of fabricated MEH-PPV based OLED and also OLET via current voltage characteristics. These studies will continue with a view to develop an optimised MEH-PPV based OLET.
    Matched MeSH terms: Lighting/instrumentation*
  5. Teh KK, Ng ES, Choon DS
    J Hand Surg Eur Vol, 2009 Aug;34(4):506-10.
    PMID: 19675032 DOI: 10.1177/1753193409100962
    This cadaveric study evaluates the margin of safety and technical efficacy of mini open carpal tunnel release performed using Knifelight (Stryker Instruments) through a transverse 1 cm wrist incision. A single investigator released 32 wrists in 17 cadavers. The wrists were then explored to assess the completeness of release and damage to vital structures including the superficial palmar arch, palmar cutaneous branch and recurrent branch of the median nerve. All the releases were complete and no injury to the median nerve and other structures were observed. The mean distance of the recurrent motor branch to the ligamentous divisions was 5.7 +/- 2.4 mm, superficial palmar arch was 8.7 +/- 3.1 mm and palmar cutaneous branch to the ligamentous division was 7.2 +/- 2.4 mm. The mean length of the transverse carpal ligament was 29.3 +/- 3.7 mm. Guyon's canal was preserved in all cases.
    Matched MeSH terms: Lighting/instrumentation*
  6. Van Rostenberghe H, Ho JJ, Lim CH, Abd Hamid IJ
    Cochrane Database Syst Rev, 2020 07 01;7:CD012011.
    PMID: 32609375 DOI: 10.1002/14651858.CD012011.pub2
    BACKGROUND: Phototherapy is a well-established effective therapy for treating babies with significant neonatal jaundice. Studies have shown that increasing light intensity will increase its efficiency. A potentially inexpensive and easy way of increasing the intensity of light on the body of the infant may be to hang reflective materials from the sides of phototherapy units.

    OBJECTIVES: To assess the effects of reflective materials in combination with phototherapy compared with phototherapy alone for unconjugated hyperbilirubinaemia in neonates.

    SEARCH METHODS: We used the standard search strategy of Cochrane Neonatal to search the Cochrane Central Register of Controlled Trials (CENTRAL; 2019, Issue 11), in the Cochrane Library; Ovid MEDLINE(R) and Epub Ahead of Print, In-Process & Other Non-Indexed Citations, Daily and Versions(R); and the Cumulative Index of Nursing and Allied Health Literature (CINAHL), on 1 November 2019. We also searched clinical trials databases and the reference lists of retrieved articles for randomised controlled trials and quasi-randomised trials.

    SELECTION CRITERIA: We included randomised and quasi-randomised controlled trials if the participants, who were term or preterm infants, received phototherapy with curtains made of reflective materials of any type in the treatment arm, and if those in the comparison arm received similar phototherapy without curtains or other intensified phototherapy, such as a double bank of lights.

    DATA COLLECTION AND ANALYSIS: We used standard methodological procedures expected by Cochrane. We used the GRADE approach to assess the certainty of evidence.

    MAIN RESULTS: Of 15 studies identified, we included 12 (1288 babies) in the review - 11 comparing phototherapy with reflective materials and phototherapy alone, and one comparing a single phototherapy light bank with reflective materials with double phototherapy. All reflective materials consisted of curtains on three or four sides of the cot and were made of white plastic (five studies), white linen (two studies), or aluminium (three studies); materials were not specified in two studies. Only 11 studies (10 comparing reflective materials versus none and one comparing reflective curtains and a single bank of lights with a double (above and below) phototherapy unit) provided sufficient data to be included in the meta-analysis. Two excluded studies used the reflective materials in a way that did not meet our inclusion criteria, and we excluded one study because it compared four different phototherapy interventions not including reflective materials. The risk of bias of included studies was generally low, but all studies had high risk of performance bias due to lack of blinding of the intervention. Three studies (281 participants) reported a decline in serum bilirubin (SB) (μmol/L) at four to eight hours (mean difference (MD) -14.61, 95% confidence interval (CI) -19.80 to -9.42; I² = 57%; moderate-certainty evidence). Nine studies (893 participants) reported a decline in SB over 24 hours and showed a faster decline in SB in the intervention group, but heterogeneity (I² = 97%) was too substantial to permit a meaningful estimate of the actual effect size (very low-certainty evidence). Subgroup analysis by type of reflective material used did not explain the heterogeneity. Exchange transfusion was reported by two studies; both reported none in either group. Four studies (466 participants) reported the mean duration of phototherapy, and in each of these studies, it was reduced in the intervention group but there was substantial heterogeneity (I² = 88%), precluding meaningful meta-analysis of data. The only two studies that reported the mean duration of hospital stay in hours showed a meaningful reduction (MD -41.08, 95% CI -45.92 to -36.25; I² = 0; moderate-certainty evidence). No studies reported costs of the intervention, parental or medical staff satisfaction, breastfeeding outcomes, or neurodevelopmental follow-up. The only study that compared use of curtains with double phototherapy reported similar results for both groups. Studies that monitored adverse events did not report increased adverse events related to the use of curtains, including acute life-threatening events, but other rarer side effects could not be excluded.

    AUTHORS' CONCLUSIONS: Moderate-certainty evidence shows that the use of reflective curtains during phototherapy may result in greater decline in SB. Very low-certainty evidence suggests that the duration of phototherapy is reduced, and moderate-certainty evidence shows that the duration of hospital stay is also reduced. Available evidence does not show any increase in adverse events, but further studies are needed.

    Matched MeSH terms: Lighting/instrumentation
  7. Lee YM, Sheppard E
    Accid Anal Prev, 2016 Oct;95(Pt A):202-8.
    PMID: 27450792 DOI: 10.1016/j.aap.2016.07.011
    Failure in making the correct judgment about the intention of an approaching vehicle at a junction could lead to a collision. This paper investigated the impact of dynamic information on drivers' judgments about the intentions of approaching cars and motorcycles, and whether a valid or invalid signal was provided was also manipulated. Participants were presented with videoclips of vehicles approaching a junction which terminated immediately before the vehicle made any manoeuvre, or images of the final frame of each video. They were asked to judge whether or not the vehicle would turn. Drivers were better in judging the manoeuvre of approaching vehicles in dynamic than static stimuli, for both vehicle types. Drivers were better in judging the manoeuvre of cars than motorcycles for videos, but not for photographs. Drivers were also better in judging the manoeuvre of approaching vehicles when a valid signal was provided than an invalid signal, demonstrating the importance of providing a valid signal while driving. However, drivers were still somewhat successful in their judgments in most of the conditions with an invalid signal, suggesting that drivers were able to focus on other cues to intention. Finally, given that dynamic stimuli more closely reflect the demands of real-life driving there may be a need for drivers to adopt a more cautious approach while inferring a motorcyclist's intentions.
    Matched MeSH terms: Lighting/instrumentation*
  8. Rahman HA, Che Ani AI, Harun SW, Yasin M, Apsari R, Ahmad H
    J Biomed Opt, 2012 Jul;17(7):071308.
    PMID: 22894469 DOI: 10.1117/1.JBO.17.7.071308
    The purpose of this study is to investigate the potential of intensity modulated fiber optic displacement sensor scanning system for the imaging of dental cavity. Here, we discuss our preliminary results in the imaging of cavities on various teeth surfaces, as well as measurement of the diameter of the cavities which are represented by drilled holes on the teeth surfaces. Based on the analysis of displacement measurement, the sensitivities and linear range for the molar, canine, hybrid composite resin, and acrylic surfaces are obtained at 0.09667 mV/mm and 0.45 mm; 0.775 mV/mm and 0.4 mm; 0.5109 mV/mm and 0.5 mm; and 0.25 mV/mm and 0.5 mm, respectively, with a good linearity of more than 99%. The results also show a clear distinction between the cavity and surrounding tooth region. The stability, simplicity of design, and low cost of fabrication make it suitable for restorative dentistry.
    Matched MeSH terms: Lighting/instrumentation*
  9. Cyranoski D, Law YH, Ong S, Phillips N, Zastrow M
    Nature, 2018 06;558(7711):502-510.
    PMID: 29950631 DOI: 10.1038/d41586-018-05506-1
    Matched MeSH terms: Lighting/instrumentation*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links