Affiliations 

  • 1 Faculty of Pharmacy, Universiti Kebangsaan Malaysia, Jalan Raja Muda Abdul Aziz, Kuala Lumpur, 50300, Malaysia. nsfern@gmail.com
  • 2 Strathclyde Institute of Pharmacy and Biomedical Sciences, University of Strathclyde, Taylor Street, Glasgow G4 0NR, UK
  • 3 GlaxoSmithKline, Pharmaceutical Development, Harlow, CM19 5AW, UK
Pharmaceutics, 2010 May 18;2(2):209-223.
PMID: 27721352

Abstract

Synthetic membranes used in Franz diffusion cells for topical formulation quality assessment should provide least resistance to drug diffusion. In this study, the diffusion rates of ibuprofen across thirteen membranes were determined using Franz diffusion cells. Correlation of the membrane thickness, pore size and MWCO with drug fluxes was also made. The drug diffusion results showed that the porous membranes were categorized into high-flux (8-18 mg/cm²/h) and low-flux (0.1-3 mg/cm²/h) membranes. The drug fluxes did not show strong correlations (r² < 0.99) with membrane parameters. Synthetic membranes can give variable drug fluxes, thus investigators should be careful in choosing membrane for formulation quality assessment.

* Title and MeSH Headings from MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine.