Affiliations 

  • 1 Department of Chemistry, Faculty of Science, University of Malaya, 50603, Kuala Lumpur, Malaysia
  • 2 Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, 50603, Kuala Lumpur, Malaysia
  • 3 Department of Pathology, Faculty of Medicine, University of Malaya, 50603, Kuala Lumpur, Malaysia
  • 4 Low Dimensional Materials Research Centre, Department of Physics, Faculty of Science, University of Malaya, 50603, Kuala Lumpur, Malaysia
  • 5 Department of Chemistry, Faculty of Science, University of Malaya, 50603, Kuala Lumpur, Malaysia; Centre for Innovation in Medical Engineering, Faculty of Engineering, University of Malaya, 50603, Kuala Lumpur, Malaysia. Electronic address: naomikhor@um.edu.my
Biosens Bioelectron, 2020 Jan 01;147:111792.
PMID: 31678828 DOI: 10.1016/j.bios.2019.111792

Abstract

Recently, surface enhanced Raman scattering (SERS) has attracted much attention in medical diagnosis applications owing to better detection sensitivity and lower limit of detection (LOD) than colorimetric detection. In this paper, a novel calibration-free SERS-based μPAD with multi-reaction zones for simultaneous quantitative detection of multiple cardiac biomarkers - GPBB, CK-MB and cTnT for early diagnosis and prognosis of acute myocardial infarction (AMI) are presented. Three distinct Raman probes were synthesised, subsequently conjugated with respective detecting antibodies and used as SERS nanotags for cardiac biomarker detection. Using a conventional calibration curve, quantitative simultaneous measurement of multiple cardiac biomarkers on SERS-based μPAD was performed based on the characteristic Raman spectral features of each reporter used in different nanotags. However, a calibration free point-of-care testing device is required for fast screening to rule-in and rule-out AMI patients. Partial least squares predictive models were developed and incorporated into the immunosensing system, to accurately quantify the three unknown cardiac biomarkers levels in serum based on the previously obtained Raman spectral data. This method allows absolute quantitative measurement when conventional calibration curve fails to provide accurate estimation of cardiac biomarkers, especially at low and high concentration ranges. Under an optimised condition, the LOD of our SERS-based μPAD was identified at 8, 10, and 1 pg mL-1, for GPBB, CK-MB and cTnT, respectively, which is well below the clinical cutoff values. Therefore, this proof-of-concept technique shows significant potential for highly sensitive quantitative detection of multiplex cardiac biomarkers in human serum to expedite medical decisions for enhanced patient care.

* Title and MeSH Headings from MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine.