Displaying publications 1 - 20 of 57 in total

Abstract:
Sort:
  1. Wan Abas WA
    Biomed Mater Eng, 1994;4(7):473-86.
    PMID: 7881331
    The response of human skin to biaxial stretch tests in vivo was investigated and compared to the response to uniaxial tension. The results obtained illustrate the nonlinear, anisotropic, and viscoelastic (time-dependent) properties of skin under biaxial stretch. Preconditioning in the load-extension response was found not to be prominent. The results also suggest that the response of skin to a biaxial stretch in vivo is qualitatively similar to that in vitro. Values of the terminal stiffness and limit strain of skin under a biaxial stretch are found.
  2. Wan Abas WA, Asseli MR
    Biomed Mater Eng, 1994;4(7):463-71.
    PMID: 7881330
    Local strains acting across an area of skin loaded uniaxially in vivo are converted to stresses using the standard elastic formulae. The stress values are compared to those obtained using the classical Bossinesq and Michell stress functions. The results indicate that these functions are capable of describing the response of the skin, both in the low load and the high load regions.
  3. Wan Abas WA
    Biomed Mater Eng, 1995;5(2):59-63.
    PMID: 7655319
    The response of human skin to "stress relaxation" tests at low loads in vitro was investigated. A number of behaviours, other than those already well established and documented, were observed. The significant behaviours are pure recovery and relaxation-recovery. Other behaviours observed are temporary stress recovery during the relaxation process, and momentary sudden non-linear drop in stress value followed by a second relaxation. The pure recovery and relaxation-recovery responses are repeatable. The latter represents the transitional response between the well-known behaviour of stress relaxation and the behaviour of stress recovery.
  4. Ibrahim F, Ismail NA, Taib MN, Wan Abas WA
    Physiol Meas, 2004 Jun;25(3):607-15.
    PMID: 15253113 DOI: 10.1088/0967-3334/25/3/002
    This paper describes a model for predicting hemoglobin (Hb) by using bioelectrical impedance analysis (BIA) in dengue patients in the Hospital Universiti Kebangsaan Malaysia (HUKM). Bioelectrical impedance measurements were conducted on 83 (47 males and 36 females) serologically confirmed dengue fever (DF) and dengue hemorrhagic fever (DHF) patients during their hospitalization. The predictive equation for Hb was derived using multivariate analysis. We investigated all the parameters in BIA, patients' symptom and demographic data. In this developed model, four predictors (reactance (XC), sex, weight and vomiting) were found to be the best predictive factors for modeling Hb in dengue patients. However, the model can only explain approximately 42% of the variation in Hb status, thus single frequency bio-impedance stand-alone technique is insufficient to monitor Hb for the DF and DHF patients. Further investigation using multi-frequency BIA is recommended in modeling Hb to achieve the most parsimonious model.
  5. Ibrahim F, Taib MN, Abas WA, Guan CC, Sulaiman S
    Comput Methods Programs Biomed, 2005 Sep;79(3):273-81.
    PMID: 15925426
    Dengue fever (DF) is an acute febrile viral disease frequently presented with headache, bone or joint and muscular pains, and rash. A significant percentage of DF patients develop a more severe form of disease, known as dengue haemorrhagic fever (DHF). DHF is the complication of DF. The main pathophysiology of DHF is the development of plasma leakage from the capillary, resulting in haemoconcentration, ascites, and pleural effusion that may lead to shock following defervescence of fever. Therefore, accurate prediction of the day of defervescence of fever is critical for clinician to decide on patient management strategy. To date, no known literature describes of any attempt to predict the day of defervescence of fever in DF patients. This paper describes a non-invasive prediction system for predicting the day of defervescence of fever in dengue patients using artificial neural network. The developed system bases its prediction solely on the clinical symptoms and signs and uses the multilayer feed-forward neural networks (MFNN). The results show that the proposed system is able to predict the day of defervescence in dengue patients with 90% prediction accuracy.
  6. Ibrahim F, Ooi KF, Ismail NA, Taib MN, Wan Abas WA
    Conf Proc IEEE Eng Med Biol Soc, 2007 2 7;2005:4130-3.
    PMID: 17281142
    This paper describes the water compartments in healthy subjects and dengue patients on the day of defervescence of fever using bioelectrical impedance analysis. A total of 223 healthy subjects (65 males and 158 females) and 210 dengue patients (119 males and 91 females) in Hospital Universiti Kebangsaan Malaysia (HUKM), were studied. The ages for healthy subjects vary between 14 and 60 years old with mean age of 26.05 years while the ages for the dengue patients vary between 12 and 83 years old with mean age of 30.14 years. The parameters of water compartments investigated were total body water (TBW), extracellular water (ECW) and intracellular water (ICW). There were significant difference between healthy subjects and dengue patients for both male (p<0.05) and female (p<0.001) beginning on fever day 0 till fever day 4. The mean TBW and ECW values of dengue patients obtained were found to be higher than the normal healthy subjects while the mean ICW was lower. The mean TBW and ICW for male were higher than female while the mean ECW for male was lower than female for healthy subjects and dengue patients.
  7. Moo EK, Osman NA, Pingguan-Murphy B, Abas WA, Spence WD, Solomonidis SE
    Acta Bioeng Biomech, 2009;11(4):37-43.
    PMID: 20405814
    Conventionally, patellar tendon-bearing (PTB) sockets, which need high dexterity of prosthetist, are widely used. Lack of chartered and experienced prosthetist has often led to painful experience of wearing prosthesis and this will in turn deter the patients to wear the prosthesis, which will further aggravate stump shrinkage. Thus, the hydrostatic socket which demands relatively lower level of fabricating skill is proposed to replace the PTB socket in order to produce the equivalent, if not better, quality of support to the amputee patients. Both sockets' pressure profiles are studied and compared using finite element analysis (FEA) software. Three-dimensional models of both sockets were developed using MIMICS software. The analysis results showed that hydrostatic socket did exhibit more uniform pressure profiles than that of PTB socket. PTB socket showed pressure concentration near the proximal brim of the socket and also at the distal fibula. It was also found that the pressure magnitude in hydrostatic socket is relatively lower than that of PTB socket.
  8. Tham LK, Osman NA, Lim KS, Pingguan-Murphy B, Abas WA, Zain NM
    Med Eng Phys, 2011 May;33(4):407-10.
    PMID: 21146440 DOI: 10.1016/j.medengphy.2010.11.002
    The investigation of patellar tendon reflex involves development of a reflex hammer holder, kinematic data collection and analysis of patellar reflex responses using motion analysis techniques. The main aim of this research is to explore alternative means of assessing reflexes as a part of routine clinical diagnosis. The motion analysis system was applied to provide quantitative data which is a more objective measure of the patellar tendon reflex. Kinematic data was collected from 28 males and 22 females whilst subjected to a knee jerk test. Further analysis of kinematic data was performed to predict relationships which might affect the patellar tendon reflex. All subjects were seated on a high stool with their legs hanging freely within the capture volume of the motion analysis system. Knee jerk tests were applied to all subjects, on both sides of the leg, by eliciting hypo, hyper, and normal reflexes. An additional reinforcement technique called the Jendrassik manoeuvre was also performed under the same conditions to elicit a normal patellar tendon reflex. The comparison of reflex response between genders showed that female subjects generally had a greater response compared to males. However, the difference in reflex response between the left leg and the right leg was not significant. Tapping strength to elicit a hyper-reflex produced greater knee-jerk compared to the normal clinical tapping strength. All results were in agreement with clinical findings and results found by some early researchers.
  9. Gholizadeh H, Abu Osman NA, Lúvíksdóttir Á, Eshraghi A, Kamyab M, Wan Abas WA
    Prosthet Orthot Int, 2011 Dec;35(4):360-4.
    PMID: 21975850 DOI: 10.1177/0309364611423130
    Good suspension lessens the pistoning (vertical displacement) of the residual limb inside the prosthetic socket. Several methods are used for measuring the pistoning.
  10. Gholizadeh H, Osman NA, Kamyab M, Eshraghi A, Abas WA, Azam MN
    Clin Biomech (Bristol, Avon), 2012 Jan;27(1):34-9.
    PMID: 21794965 DOI: 10.1016/j.clinbiomech.2011.07.004
    The method of attachment of prosthesis to the residual limb (suspension) and socket fitting is a critical issue in the process of providing an amputee with prosthesis. Different suspension methods try to minimize the pistoning movement inside the socket. The Seal-In(®) X5 and Dermo(®) Liner by Ossur are new suspension liners that intend to reduce pistoning between the socket and liner. Since the effects of these new liners on suspension are unclear, the objective of this study was to compare the pistoning effect of Seal-In(®) X5 and Dermo(®) Liner by using Vicon Motion System.
  11. Ku PX, Abu Osman NA, Yusof A, Wan Abas WA
    J Biomech, 2012 Jun 1;45(9):1638-42.
    PMID: 22507349 DOI: 10.1016/j.jbiomech.2012.03.029
    Postural stability is crucial in maintaining body balance during quiet standing, locomotion, and any activities that require a high degree of balance performance, such as participating in sports and dancing. Research has shown that there is a relationship between stability and body mass. The aims of this study were to examine the impact that two variables had on static postural control: body mass index (BMI) and gender. Eighty healthy young adults (age=21.7±1.8 yr; height=1.65±0.09 m; mass=67.5±19.0 kg) participated in the study and the static postural control was assessed using the Biodex Balance System, with a 20 Hz sampling rate in the bipedic stance (BLS) and unipedic stance (ULS) for 30s. Five test evaluations were performed for each balance test. Postural control was found to be negatively correlated with increased adiposity, as the obese BMI group performed significantly poorer than the underweight, normal weight and overweight groups during BLS and ULS tests. The underweight, normal weight and overweight groups exhibited greater anterior-posterior stability in postural control during quiet stance. In addition, female displayed a trend of having a greater postural sway than male young adults, although it was evidenced in only some BMI groups. This study revealed that BMI do have an impact on postural control during both BLS and ULS. As such, BMI and gender-specific effects should be taken into consideration when selecting individuals for different types of sporting activities, especially those that require quiet standing.
  12. Gholizadeh H, Abu Osman NA, Kamyab M, Eshraghi A, Lúvíksdóttir AG, Wan Abas WA
    Am J Phys Med Rehabil, 2012 Oct;91(10):894-8.
    PMID: 22173083
    The effects of Seal-In X5 and Dermo liner (Össur) on suspension and patient's comfort in lower limb amputees are unclear. In this report, we consider the case of a 51-yr-old woman with bilateral transtibial amputation whose lower limbs were amputated because of peripheral vascular disease. The subject had bony and painful residual limbs, especially at the distal ends. Two prostheses that used Seal-In X5 liners and a pair of prostheses with Dermo liners were fabricated, and the subject wore each for a period of 2 wks. Once the 2 wks had passed, the pistoning within the socket was assessed and the patient was questioned as to her satisfaction with both liners. This study revealed that Seal-In X5 liner decreased the residual limb pain experienced by the patient and that 1-2 mm less pistoning occurred within the socket compared with the Dermo liner. However, the patient needed to put in extra effort for donning and doffing the prosthesis. Despite this, it is clear that the Seal-In X5 liner offers a viable alternative for individuals with transtibial amputations who do not have enough soft tissue around the bone, especially at the end of the residual limb.
  13. Ali S, Osman NA, Mortaza N, Eshraghi A, Gholizadeh H, Wan Abas WA
    Clin Biomech (Bristol, Avon), 2012 Nov;27(9):943-8.
    PMID: 22795863 DOI: 10.1016/j.clinbiomech.2012.06.004
    The interface pressure between the residual limb and prosthetic socket has a significant effect on an amputee's satisfaction and comfort. Liners provide a comfortable interface by adding a soft cushion between the residual limb and the socket. The Dermo and the Seal-In X5 liner are two new interface systems and, due to their relative infancy, very little are known about their effect on patient satisfaction. The aim of this study was to compare the interface pressure with these two liners and their effect on patient satisfaction.
  14. Eshraghi A, Abu Osman NA, Karimi MT, Gholizadeh H, Ali S, Wan Abas WA
    Am J Phys Med Rehabil, 2012 Dec;91(12):1028-38.
    PMID: 23168378 DOI: 10.1097/PHM.0b013e318269d82a
    The objectives of this study were to compare the effects of a newly designed magnetic suspension system with that of two existing suspension methods on pistoning inside the prosthetic socket and to compare satisfaction and perceived problems among transtibial amputees.
  15. Ku PX, Abu Osman NA, Yusof A, Wan Abas WA
    PLoS One, 2012;7(7):e41539.
    PMID: 22848523 DOI: 10.1371/journal.pone.0041539
    Postural balance is vital for safely carrying out many daily activities, such as locomotion. The purpose of this study was to determine how changes in normal standing (NS) and standing with toe-extension (SWT) impact postural control during quiet standing. Furthermore, the research aimed to examine the extent to which the effect of these factors differed between genders.
  16. Gholizadeh H, Abu Osman NA, Eshraghi A, Ali S, Sævarsson SK, Wan Abas WA, et al.
    J Rehabil Res Dev, 2012;49(9):1321-30.
    PMID: 23408214
    Poor suspension increases slippage of the residual limb inside the socket during ambulation. The main purpose of this article is to evaluate the pistoning at the prosthetic liner-socket interface during gait and assess patients' satisfaction with two different liners. Two prostheses with seal-in and locking liners were fabricated for each of the 10 subjects with transtibial amputation. The Vicon motion system was used to measure the pistoning during gait. The subjects were also asked to complete a Prosthesis Evaluation Questionnaire. The results revealed higher pistoning inside the socket during gait with the locking liner than with the seal-in liner (p < 0.05). The overall satisfaction with the locking liner was higher (p < 0.05) because of the relative ease with which the patients could don and doff the device. As such, pistoning may not be the main factor that determines patients' overall satisfaction with the prosthesis and other factors may also contribute to comfort and satisfaction with prostheses. The article also verifies the feasibility of the Vicon motion system for measuring pistoning during gait.
  17. Muhammad KB, Abas WA, Kim KH, Pingguan-Murphy B, Zain NM, Akram H
    Clinics (Sao Paulo), 2012;67(6):629-38.
    PMID: 22760903
    OBJECTIVE: Dark poly(caprolactone) trifumarate is a successful candidate for use as a bone tissue engineering scaffold. Recently, a white polymeric scaffold was developed that shows a shorter synthesis time and is more convenient for tissue-staining work. This is an in vitro comparative study of both the white and dark scaffolds.

    METHODS: Both white and dark poly(caprolactone) trifumarate macromers were characterized via Fourier transform infrared spectroscopy before being chemically cross-linked and molded into disc-shaped scaffolds. Biodegradability was assessed by percentage weight loss on days 7, 14, 28, 42 and 56 (n = 5) after immersion in 10% serum-supplemented medium or distilled water. Static cell seeding was employed in which isolated and characterized rat bone marrow stromal cells were seeded directly onto the scaffold surface. Seeded scaffolds were subjected to a series of biochemical assays and scanning electron microscopy at specified time intervals for up to 28 days of incubation.

    RESULTS: The degradation of the white scaffold was significantly lower compared with the dark scaffold but was within the acceptable time range for bone-healing processes. The deoxyribonucleic acid and collagen contents increased up to day 28 with no significant difference between the two scaffolds, but the glycosaminoglycan content was slightly higher in the white scaffold throughout 14 days of incubation. Scanning electron microscopy at day 1 [corrected] revealed cellular growth and attachment.

    CONCLUSIONS: There was no cell growth advantage between the two forms, but the white scaffold had a slower biodegradability rate, suggesting that the newly synthesized poly(caprolactone) trifumarate is more suitable for use as a bone tissue engineering scaffold.

  18. Oshkour AA, Abu Osman NA, Yau YH, Tarlochan F, Abas WA
    Proc Inst Mech Eng H, 2013 Jan;227(1):3-17.
    PMID: 23516951
    This study aimed to develop a three-dimensional finite element model of a functionally graded femoral prosthesis. The model consisted of a femoral prosthesis created from functionally graded materials (FGMs), cement, and femur. The hip prosthesis was composed of FGMs made of titanium alloy, chrome-cobalt, and hydroxyapatite at volume fraction gradient exponents of 0, 1, and 5, respectively. The stress was measured on the femoral prosthesis, cement, and femur. Stress on the neck of the femoral prosthesis was not sensitive to the properties of the constituent material. However, stress on the stem and cement decreased proportionally as the volume fraction gradient exponent of the FGM increased. Meanwhile, stress became uniform on the cement mantle layer. In addition, stress on the femur in the proximal part increased and a high surface area of the femoral part was involved in absorbing the stress. As such, the stress-shielding area decreased. The results obtained in this study are significant in the design and longevity of new prosthetic devices because FGMs offer the potential to achieve stress distribution that more closely resembles that of the natural bone in the femur.
  19. Eshraghi A, Abu Osman NA, Gholizadeh H, Ali S, Sævarsson SK, Wan Abas WA
    Clin Biomech (Bristol, Avon), 2013 Jan;28(1):55-60.
    PMID: 23157843 DOI: 10.1016/j.clinbiomech.2012.10.002
    Different suspension systems that are used within prosthetic devices may alter the distribution of pressure inside the prosthetic socket in lower limb amputees. This study aimed to compare the interface pressure of a new magnetic suspension system with the pin/lock and Seal-In suspension systems.
  20. Abd Razak NA, Abu Osman NA, Wan Abas WA
    Disabil Rehabil Assist Technol, 2013 May;8(3):255-60.
    PMID: 22830946 DOI: 10.3109/17483107.2012.704654
    This study examined the kinematic differences between a body-powered prosthesis and a biomechatronics prosthesis as a transradial amputee performed activities that involve flexion/extension and supination/pronation of the wrist.