Displaying publications 1 - 20 of 75 in total

Abstract:
Sort:
  1. Romli R, Abd Rahman R, Mohd Hashim S, Chew KT, Mohamad EMW, Mohammed Nawi A
    J Educ Health Promot, 2023;12:357.
    PMID: 38144028 DOI: 10.4103/jehp.jehp_1842_22
    INTRODUCTION: Cervical cancer remains a reproductive health burden. Pap smear (PS) screening can detect cervical cancer early but is underused despite being subsidized. Motivational factors play a role in promoting PS screening. This study aimed to determine the women's motivation toward PS screening based on Protection Motivation Theory (PMT), which mainly focused on sexual and screening status.

    MATERIALS AND METHODS: The study was conducted electronically throughout Malaysia from January to February 2022 by disseminating Google Form (https://forms.gle/cD7fkUKYR4Cq6kZC8) via multiple WhatsApp groups to reach 526 women aged 21-65 years. The questionnaire consists of 24 items based on seven PMT constructs [perceived vulnerability, perceived severity, self-efficacy, response efficacy, fear (threat appraisal), response costs (coping appraisal), and protection motivation]. The descriptive statistics and independent t-test was used to analyze data using IBM SPSS Statistics software, version 25.

    RESULTS: Most respondents were sexually active [80.6% (n = 424)] and have heard of PS screening [95.8% (n = 504)]. More than half of respondents did not have PS screening in the last three years [59.3% (n = 312)]. Sexually active women have heard and have undergone PS screening feel less threatened with low coping appraisals. Undergoing PS screening made women perceived more response efficacy (P =. 011), more self-efficacy (P

  2. Gunasagaran J, Ab Wahab N, Khoo SS, Shamsul SA, Shivdas S, Hashim S, et al.
    J Orthop Surg (Hong Kong), 2023;31(2):10225536231180330.
    PMID: 37256763 DOI: 10.1177/10225536231180330
    BACKGROUND: In complete brachial plexus injury, phrenic nerve (PN) is frequently used in neurotization for elbow flexion restoration. The advancement in video-assisted thoracoscopic surgery (VATS) allows full-length PN dissection intrathoracically for direct coaptation to recipient without nerve graft.

    PURPOSE: We report our experience in improving the surgical technique and its outcome.

    METHODS: Seven patients underwent PN dissection via VATS and full-length transfer to musculocutaneous nerve (MCN) or motor branch of biceps (MBB) from June 2015 to June 2018. Comparisons were made with similar group of patients who underwent conventional PN transfer.

    RESULTS: Mean age of patients was 21.9 years. All were males involved in motorcycle accidents who sustained complete brachial plexus injury. We found the elbow flexion recovery were earlier in full-length PN transfer. However, there was no statistically significant difference in elbow flexion strength at 3 years post-surgery.

    CONCLUSION: We propose full-length PN transfer for restoration of elbow flexion in patients with delayed presentation.

  3. Majeed Alneamy JS, A Hameed Alnaish Z, Mohd Hashim SZ, Hamed Alnaish RA
    Comput Biol Med, 2019 09;112:103348.
    PMID: 31356992 DOI: 10.1016/j.compbiomed.2019.103348
    Accurate medical disease diagnosis is considered to be an important classification problem. The main goal of the classification process is to determine the class to which a certain pattern belongs. In this article, a new classification technique based on a combination of The Teaching Learning-Based Optimization (TLBO) algorithm and Fuzzy Wavelet Neural Network (FWNN) with Functional Link Neural Network (FLNN) is proposed. In addition, the TLBO algorithm is utilized for training the new hybrid Functional Fuzzy Wavelet Neural Network (FFWNN) and optimizing the learning parameters, which are weights, dilation and translation. To evaluate the performance of the proposed method, five standard medical datasets were used: Breast Cancer, Heart Disease, Hepatitis, Pima-Indian diabetes and Appendicitis. The efficiency of the proposed method is evaluated using 5-fold cross-validation and 10-fold cross-validation in terms of mean square error (MSE), classification accuracy, running time, sensitivity, specificity and kappa. The experimental results show that the efficiency of the proposed method for the medical classification problems is 98.309%, 91.1%, 91.39%, 88.67% and 93.51% for the Breast Cancer, Heart Disease, Hepatitis, Pima-Indian diabetes and Appendicitis datasets, respectively, in terms of accuracy after 30 runs for each dataset with low computational complexity. In addition, it has been observed that the proposed method has efficient performance compared with the performance of other methods found in the related previous studies.
  4. Hashim S, Ishak A, Muhammad J
    Korean J Fam Med, 2020 Nov;41(6):416-421.
    PMID: 33242382 DOI: 10.4082/kjfm.19.0060
    BACKGROUND: Breastfeeding is widely recognized as the optimal and natural method of feeding infants. However, there are obstacles that can limit exclusive breastfeeding practices during the first 6 months of an infant's life. This study aimed to determine the prevalence of unsuccessful exclusive breastfeeding and its associated factors among mothers who work as healthcare providers at Universiti Sains Malaysia Hospital.

    METHODS: A cross-sectional study was conducted among 295 medical doctors and staff nurses from June to December 2015. Simple random sampling was applied. The data were collected using a self-administered questionnaire and analyzed using IBM SPSS ver. 22.0 (IBM Corp., Armonk, NY, USA). Descriptive statistics and logistic regression analysis were performed.

    RESULTS: The prevalence of unsuccessful exclusive breastfeeding among the study participants was 58.3%. Mothers who preferred formula milk (odds ratio [OR], 4.40; 95% confidence interval [CI], 1.45-13.31) delivered via lower segment cesarean section (OR, 2.31; 95% CI, 1.07-4.98) and produced inadequate breast milk (OR, 4.06; 95% CI, 2.40- 6.89) were significantly associated with unsuccessful exclusive breastfeeding.

    CONCLUSION: The prevalence of unsuccessful exclusive breastfeeding among the study participants was high. Maternal characteristics such as preference towards formula milk, mode of delivery and adequacy of breast milk must be assessed to prevent unsuccessful exclusive breastfeeding among healthcare providers.

  5. Romli R, Mohd Hashim S, Abd Rahman R, Chew KT, Mohamad EMW, Mohammed Nawi A
    Gynecol Oncol Rep, 2024 Apr;52:101349.
    PMID: 38435346 DOI: 10.1016/j.gore.2024.101349
    PURPOSE: Cervical cancer (CC) screening remains challenging, where the motivational focus towards utilizing CC screening services is rarely highlighted. This study aimed to understand the motivation to undergo CC screening from women and healthcare practitioners' perspectives based on Protection Motivation Theory (PMT).

    METHOD: This qualitative study used the nominal group technique (NGT) and in-depth interview (IDI), where the NGT participants were healthcare practitioners from various disciplines (n = 12). Nominal group discussions were conducted via Zoom and involved one moderator, facilitator and observer. The IDI was conducted via Google Meet among seven women who had been included based on purposive sampling. All nominal group discussions and interviews were transcribed, verbatim and underwent deductive thematic analysis.

    RESULTS: Healthcare practitioners emphasized input on CC knowledge of epidemiology, risk, etiology, nature, and outcome to encourage motivation. Women underlined their important role in the family, and reducing the negative perception as a motivational focus. Having living example of witnessing the CC patient dying and fear of stigma of cancer could be the driven force to undergo screening. Emphasis on the important of sufficient knowledge and correct the misconceptions towards screening could impart the motivation among women.

    CONCLUSIONS: The motivational focus was enriched by the differing perspectives of the healthcare practitioners and women. The findings can guide intervention program development towards enhancing CC screening in the future.

  6. Kuldas S, Ismail HN, Hashim S, Bakar ZA
    Springerplus, 2013 Dec;2(1):105.
    PMID: 23556145 DOI: 10.1186/2193-1801-2-105
    This review aims to provide an insight into human learning processes by examining the role of cognitive and emotional unconscious processing in mentally integrating visual and verbal instructional materials. Reviewed literature shows that conscious mental integration does not happen all the time, nor does it necessarily result in optimal learning. Students of all ages and levels of experience cannot always have conscious awareness, control, and the intention to learn or promptly and continually organize perceptual, cognitive, and emotional processes of learning. This review suggests considering the role of unconscious learning processes to enhance the understanding of how students form or activate mental associations between verbal and pictorial information. The understanding would assist in presenting students with spatially-integrated verbal and pictorial instructional materials as a way of facilitating mental integration and improving teaching and learning performance.
  7. Alajerami YS, Hashim S, Ramli AT, Saleh MA, Saripan MI, Alzimami K, et al.
    Appl Radiat Isot, 2013 Aug;78:21-5.
    PMID: 23644162 DOI: 10.1016/j.apradiso.2013.03.095
    New glasses Li2CO3-K2CO3-H3BO3 (LKB) co-doped with CuO and MgO, or with TiO2 and MgO, were synthesized by the chemical quenching technique. The thermoluminescence (TL) responses of LKB:Cu,Mg and LKB:Ti,Mg irradiated with 6 MV photons or 6 MeV electrons were compared in the dose range 0.5-4.0 Gy. The standard commercial dosimeter LiF:Mg,Ti (TLD-100) was used to calibrate the TL reader and as a reference in comparison of the TL properties of the new materials. The dependence of the responses of the new materials on (60)Co dose is linear in the range of 1-1000 Gy. The TL yields of both of the co-doped glasses and TLD-100 are greater for electron irradiation than for photon irradiation. The TL sensitivity of LKB:Ti,Mg is 1.3 times higher than the sensitivity of LKB:Cu,Mg and 12 times less than the sensitivity of TLD-100. The new TL dosimetric materials have low effective atomic numbers, good linearity of the dose responses, excellent signal reproducibility, and a simple glow curve structure. This combination of properties makes them suitable for radiation dosimetry.
  8. Lim TY, Wagiran H, Hussin R, Hashim S
    Appl Radiat Isot, 2015 Aug;102:10-4.
    PMID: 25933405 DOI: 10.1016/j.apradiso.2015.04.005
    The paper presents the thermoluminescence (TL) response of strontium tetraborate glass subjected to electron irradiations at various Dy2O3 concentrations ranging from 0.00 to 1.00mol%. All glass samples exhibited single broad peak with maximum peak temperature positioned at 170-215°C. The optimum TL response was found at Dy2O3 concentration 0.75mol%. This glass showed good linearity and higher sensitivity for 7MeV compared to 6MeV electrons. Analysis of kinetic parameters showed that the glasses demonstrate second order kinetic.
  9. Mhareb MH, Hashim S, Ghoshal SK, Alajerami YS, Saleh MA, Razak NA, et al.
    Luminescence, 2015 Dec;30(8):1330-5.
    PMID: 25828828 DOI: 10.1002/bio.2902
    We report the impact of dysprosium (Dy(3+)) dopant and magnesium oxide (MgO) modifier on the thermoluminescent properties of lithium borate (LB) glass via two procedures. The thermoluminescence (TL) glow curves reveal a single prominent peak at 190 °C for 0.5 mol% of Dy(3+). An increase in MgO contents by 10 mol% enhances the TL intensity by a factor of 1.5 times without causing any shift in the maximum temperature. This enhancement is attributed to the occurrence of extra electron traps created via magnesium and the energy transfer to trivalent Dy(3+) ions. Good linearity in the range of 0.01-4 Gy with a linear correlation coefficient of 0.998, fading as low as 21% over a period of 3 months, excellent reproducibility without oven annealing and tissue equivalent effective atomic numbers ~8.71 are achieved. The trap parameters, including geometric factor (μg), activation energy (E) and frequency factor (s) associated with LMB:Dy are also determined. These favorable TL characteristics of prepared glasses may contribute towards the development of Li2O-MgO-B2O3 radiation dosimeters.
  10. Alajerami YS, Hashim S, Ramli AT, Saleh MA, Kadni T
    Radiat Prot Dosimetry, 2013 Jun;155(1):1-10.
    PMID: 23193136 DOI: 10.1093/rpd/ncs310
    The thermoluminescent properties of boric glass modified with lithium and potassium carbonates (LKB) and co-doped with CuO and MgO are reported for the first time. Two techniques are applied to investigate the effect of dopants and co-dopants on the thermal stimulation properties of LKB. The induced TL glow curves of a CuO-doped sample are found to be at 220°C with a single peak. An enhancement of about three times is shown with the increment of 0.1 mol % MgO as a co-dopant impurity. This enhancement may contribute to the ability of magnesium to create extra electron traps and consequently the energy transfer to monovalent Cu(+) ions. LKB:Cu,Mg is low Z material (Zeff=8.55), and observed 15 times less sensitive than LiF: Mg, Ti (TLD-100). The proposed dosemeter showed good linearity in TL dose-response, low fading and excellent reproducibility with a simple glow curve, and thus, can be used in the radiation dosimetry.
  11. Hashim S, Alajerami YS, Ramli AT, Ghoshal SK, Saleh MA, Abdul Kadir AB, et al.
    Appl Radiat Isot, 2014 Sep;91:126-30.
    PMID: 24929526 DOI: 10.1016/j.apradiso.2014.05.023
    Lithium potassium borate (LKB) glasses co-doped with TiO2 and MgO were prepared using the melt quenching technique. The glasses were cut into transparent chips and exposed to gamma rays of (60)Co to study their thermoluminescence (TL) properties. The TL glow curve of the Ti-doped material featured a single prominent peak at 230 °C. Additional incorporation of MgO as a co-activator enhanced the TL intensity threefold. LKB:Ti,Mg is a low-Z material (Z(eff)=8.89) with slow signal fading. Its radiation sensitivity is 12 times lower that the sensitivity of TLD-100. The dose response is linear at doses up to 10(3) Gy. The trap parameters, such as the kinetics order, activation energy, and frequency factor, which are related to the glow peak, were determined using TolAnal software.
  12. Hashim S, Al-Ahbabi S, Bradley DA, Webb M, Jeynes C, Ramli AT, et al.
    Appl Radiat Isot, 2009 Mar;67(3):423-7.
    PMID: 18693024 DOI: 10.1016/j.apradiso.2008.06.030
    Modern linear accelerators, the predominant teletherapy machine in major radiotherapy centres worldwide, provide multiple electron and photon beam energies. To obtain reasonable treatment times, intense electron beam currents are achievable. In association with this capability, there is considerable demand to validate patient dose using systems of dosimetry offering characteristics that include good spatial resolution, high precision and accuracy. Present interest is in the thermoluminescence response and dosimetric utility of commercially available doped optical fibres. The important parameter for obtaining the highest TL yield during this study is to know the dopant concentration of the SiO2 fibre because during the production of the optical fibres, the dopants tend to diffuse. To achieve this aim, proton-induced X-ray emission (PIXE), which has no depth resolution but can unambiguously identify elements and analyse for trace elements with detection limits approaching microg/g, was used. For Al-doped fibres, the dopant concentration in the range 0.98-2.93 mol% have been estimated, with equivalent range for Ge-doped fibres being 0.53-0.71 mol%. In making central-axis irradiation measurements a solid water phantom was used. For 6-MV photons and electron energies in the range 6, 9 and 12 MeV, a source to surface distance of 100 cm was used, with a dose rate of 400 cGy/min for photons and electrons. The TL measurements show a linear dose-response over the delivered range of absorbed dose from 1 to 4 Gy. Fading was found to be minimal, less than 10% over five days subsequent to irradiation. The minimum detectable dose for 6-MV photons was found to be 4, 30 and 900 microGy for TLD-100 chips, Ge- and Al-doped fibres, respectively. For 6-, 9- and 12-MeV electron energies, the minimum detectable dose were in the range 3-5, 30-50 and 800-1400 microGy for TLD-100 chip, Ge-doped and Al-doped fibres, respectively.
  13. Hashim S, Bradley DA, Saripan MI, Ramli AT, Wagiran H
    Appl Radiat Isot, 2010 Apr-May;68(4-5):700-3.
    PMID: 19892557 DOI: 10.1016/j.apradiso.2009.10.027
    This paper describes a preliminary study of the thermoluminescence (TL) response of doped SiO(2) optical fibres subjected to (241)AmBe neutron irradiation. The TL materials, which comprise Al- and Ge-doped silica fibres, were exposed in close contact with the (241)AmBe source to obtain fast neutron interactions through use of measurements obtained with and without a Cd filter (the filter being made to entirely enclose the fibres). The neutron irradiations were performed for exposure times of 1-, 2-, 3-, 5- and 7-days in a neutron tank filled with water. In this study, use was also made of the Monte Carlo N-particle (MCNP) code version 5 (V5) to simulate the neutron irradiations experiment. It was found that the commercially available Ge-doped and Al-doped optical fibres show a linear dose response subjected to fast neutrons from (241)AmBe source up to seven days of irradiations. The simulation performed using MCNP5 also exhibits a similar pattern, albeit differing in sensitivity. The TL response of Ge-doped fibre is markedly greater than that of the Al-doped fibre, the total absorption cross section for Ge in both the fast and thermal neutrons region being some ten times greater than that of Al.
  14. Ramli AT, Bradley DA, Hashim S, Wagiran H
    Appl Radiat Isot, 2009 Mar;67(3):428-32.
    PMID: 18693114 DOI: 10.1016/j.apradiso.2008.06.034
    Ion beams are used in radiotherapy to deliver a more precise dose to the target volume while minimizing dose to the surrounding healthy tissue. For optimum dose monitoring in ion-beam therapy, it is essential to be able to measure the delivered dose with a sensitivity, spatial resolution and dynamic range that is sufficient to meet the demands of the various therapy situations. Optical fibres have been demonstrated by this group to show promising thermoluminescence properties with respect to photon, electron and proton irradiation. In particular, and also given the flexibility and small size of optical fibre cores, for example 125.0+/-0.1 microm for the Al- and Ge-doped fibres used in this study, these fibres have the potential to fulfill the above requirements. This study investigates the thermoluminescence dosimetric characteristics of variously doped SiO(2) optical fibres irradiated with alpha particles from (241)Am. Following subtraction of the gamma contribution from the above source, the thermoluminescence characteristics of variously doped SiO(2) optical fibres have been compared with that of TLD-100 rods. The irradiations were performed in a bell jar. Of related potential significance is the effective atomic number, Z(eff) of the fibre, modifying measured dose from that deposited in tissues; in the present work, a scanning electron microscope and associated energy dispersive X-ray spectroscopy facility have been used to provide evaluation of Z(eff). For Ge-doped fibres, the effective atomic numbers value was 11.4, the equivalent value for Al-doped fibres was 12.3. This paper further presents results on dose response and the glow curves obtained. The results obtained indicate there to be good potential for use of variously doped SiO(2) optical fibres in measuring ion-beam doses in radiotherapeutic applications.
  15. Hashim S, Ayub ZN, Mohamed Z, Hasan H, Harun A, Ismail N, et al.
    J Travel Med, 2016 Feb;23(2):tav019.
    PMID: 26858268 DOI: 10.1093/jtm/tav019
    BACKGROUND: Respiratory illness continues to exert a burden on hajj pilgrims in Makkah. The purpose of this study is to determine the prevalence of respiratory illness and its associated factors among Malaysian hajj pilgrims in 2013 and to describe its preventive measures.

    METHODS: A cross-sectional study was conducted in Makkah and Malaysia during the 2013 hajj season. A self-administered proforma on social demographics, previous experience of hajj or umrah, smoking habits, co-morbid illness and practices of preventive measures against respiratory illness were obtained.

    RESULTS: A total of 468 proforma were analysed. The prevalence of the respiratory illness was 93.4% with a subset of 78.2% fulfilled the criteria for influenza-like illness (ILI). Most of them (77.8%) had a respiratory illness of <2 weeks duration. Approximately 61.8% were administered antibiotics but only 2.1% of them had been hospitalized. Most of them acquired the infection after a brief stay at Arafat (81.2%). Vaccination coverages for influenza virus and pneumococcal disease were quite high, 65.2% and 59.4%, respectively. For other preventive measures practices, only 31.8% of them practiced good hand hygiene, ∼82.9% of pilgrims used surgical face masks, N95 face masks, dry towels, wet towels or veils as their face masks. Nearly one-half of the respondents (44.4%) took vitamins as their food supplement. Malaysian hajj pilgrims with previous experience of hajj (OR 0.24; 95% CI 0.10-0.56) or umrah (OR 0.19; 95% CI 0.07-0.52) and those who have practiced good hand hygiene (OR 0.35; 95% CI 0.16-0.79) were found to be significantly associated with lower risk of having respiratory illness. Otherwise, pilgrims who had contact with those with respiratory illness (OR 2.61; 95% CI 1.12-6.09) was associated with higher risk.

    CONCLUSIONS: The prevalence of respiratory illness remains high among Malaysian hajj pilgrims despite having some practices of preventive measures. All preventive measures which include hand hygiene, wearing face masks and influenza vaccination must be practiced together as bundle of care to reduce respiratory illness effectively.

  16. Bamaiyi PH, Hassan L, Khairani-Bejo S, ZainalAbidin M, Ramlan M, Adzhar A, et al.
    Prev Vet Med, 2015 May 1;119(3-4):232-6.
    PMID: 25746928 DOI: 10.1016/j.prevetmed.2015.02.001
    A study was conducted to describe the prevalence and distribution of zoonotic Brucella melitensis in goats in Peninsular Malaysia. Using serosurveillance data of the last decade (2000-2009) involving 119,799 goats and 3555 farms, the seroprevalence of brucellosis among goats was 0.91% (95% CI=0.86-0.96) and among farms was 7.09% (95% CI=6.27-7.98). The odds of brucellosis was significantly (P<0.05) higher in the later part of the decade, in larger herd size and among the states located in the peninsula as compared to eastern Malaysia. The infection was detected throughout Malaysia but at generally low seroprevalences with states like Perlis that border neighbouring countries having higher seroprevalence of brucellosis than other non-border states.
  17. Hassan HJ, Hashim S, Mohd Sanusi MS, Jamal MH, Hassan SA, Bradley DA, et al.
    PLoS One, 2021;16(6):e0250528.
    PMID: 34061865 DOI: 10.1371/journal.pone.0250528
    Forming part of a study of radiological risk arising from use of radioactive consumer products, investigation is made of pendants containing naturally occurring radioactive material. Based on use of gamma-ray spectrometry and Monte Carlo (MC) simulations, the study investigates commercially available 'scalar energy pendants'. The doses from these have been simulated using MIRD5 mathematical phantoms, evaluation being made of dose conversion factors (DCFs) and organ dose. Metallic pendants code MP15 were found to contain the greatest activity, at 7043 ± 471 Bq from 232Th, while glass pendants code GP11 were presented the greatest 238U and 40K activity, at 1001 ± 172 and 687 ± 130 Bq respectively. MP15 pendants offered the greatest percentage concentrations of Th, Ce, U and Zr, with means of 25.6 ± 0.06, 5.6 ± 0.005, 1.03 ± 0.04 and 28.5 ± 0.08 respectively, giving rise to an effective dose of 2.8 mSv for a nominal wearing period of 2000 h. Accordingly, these products can give rise to annual doses in excess of the public limit of 1 mSv.
  18. Karim MKA, Rahim NA, Matsubara K, Hashim S, Mhareb MHA, Musa Y
    J Xray Sci Technol, 2019;27(1):139-147.
    PMID: 30584178 DOI: 10.3233/XST-180397
    BACKGROUND: Numerous techniques had been proposed to reduce radiation exposure in computed tomography (CT) including the use of radiation shielding.

    OBJECTIVE: This study aims to evaluate efficacy of using a bismuth breast shield and optimized scanning parameter to reduce breast absorbed doses from CT thorax examination.

    METHODS: Five protocols comprising the standard CT thorax clinical protocol (CP1) and four modified protocols (CP2 to CP5) were applied in anthropomorphic phantom scans. The phantom was configured as a female by placing a breast component on the chest. The breast component was divided into four quadrants, where 2 thermoluminescence dosimeters (TLD-100) were inserted into each quadrant to measure the absorbed dose. The bismuth shield was placed over the breast component during CP4 and CP5 scans.

    RESULTS: The pattern of absorbed doses in each breast and quadrant were approximately the same for all protocols, where the 4th quadrant > 3rd quadrant > 2nd quadrant > 1st quadrant. The mean absorbed dose value in CP3 was reduced to almost 34% of CP1's mean absorbed dose. It was reduced even lower to 15% of CP1's mean absorbed dose when the breast shield was used in CP5.

    CONCLUSION: This study showed that CT radiation exposure on the breast could be reduced by using a bismuth shield and low tube potential protocol without compromising the image quality.

  19. Che Mohd Nassir CMN, Damodaran T, Ismail NI, Hashim S, Jaffer U, Hamid HA, et al.
    Life (Basel), 2023 Jan 12;13(1).
    PMID: 36676165 DOI: 10.3390/life13010216
    In this narrative review, we present the evidence on nucleotide-binding and oligomerization (NOD) domain-like receptor (NLR) family pyrin domain (PYD)-containing 3 (NLRP3) inflammasome activation for its putative roles in the elusive pathomechanism of aging-related cerebral small vessel disease (CSVD). Although NLRP3 inflammasome-interleukin (IL)-1β has been implicated in the pathophysiology of coronary artery disease, its roles in cerebral arteriothrombotic micro-circulation disease such as CSVD remains unexplored. Here, we elaborate on the current manifestations of CSVD and its' complex pathogenesis and relate the array of activators and aberrant activation involving NLRP3 inflammasome with this condition. These neuroinflammatory insights would expand on our current understanding of CSVD clinical (and subclinical) heterogenous manifestations whilst highlighting plausible NLRP3-linked therapeutic targets.
  20. Abdullahi I, Hashim S, Ghoshal SK, Sayyed MI
    Heliyon, 2023 Oct;9(10):e20262.
    PMID: 37767474 DOI: 10.1016/j.heliyon.2023.e20262
    The demand for new glass hosts with emergent properties is constantly growing for various miniaturized applications. Thus, some new types of Sm2O3-activated strontium-telluro-alumino-magnesium-borate glasses with copper oxide nanoparticles (CuONps) insertion were made using melt-quenching approach. The obtained glasses were characterized to determine the effects of Sm2O3 concentration changes on their thermal, structural, and luminescence properties. XRD, FTIR, and HRTEM analyses of the samples verified their glassy nature, presence of different functional units and CuONps, respectively. DTA analysis showed excellent thermal stability of these glasses with a stability factor as much as 125 °C. The optical absorption properties of the glasses were highly sensitive to Sm3+ concentrations variation. The Judd-Ofelt intensity parameters of the glasses with and without CuONps followed the trend of Ω6˃Ω4˃Ω2 and Ω4˃Ω6˃Ω2, respectively. These glasses displayed 4 visible luminescence bands at 561, 598, 645, and 705 nm corresponding to 4G5/2 → 6H5/2, 4G5/2 → 6H7/2, 4G5/2 → 6H9/2, and 4G5/2 → 6H11/2 transitions in Sm3+. In addition, branching ratio above 80% and stimulated emission cross-section up to 135.82 × 10-23 cm2 were achieved. The stimulated emission cross-section and optical gain were enhanced due to the inclusion of CuONps in the glasses. These glasses may be useful for solid state laser and optical amplifier development.
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links