Displaying publications 1 - 20 of 94 in total

Abstract:
Sort:
  1. Ibrahim F, Ismail NA, Taib MN, Wan Abas WA
    Physiol Meas, 2004 Jun;25(3):607-15.
    PMID: 15253113 DOI: 10.1088/0967-3334/25/3/002
    This paper describes a model for predicting hemoglobin (Hb) by using bioelectrical impedance analysis (BIA) in dengue patients in the Hospital Universiti Kebangsaan Malaysia (HUKM). Bioelectrical impedance measurements were conducted on 83 (47 males and 36 females) serologically confirmed dengue fever (DF) and dengue hemorrhagic fever (DHF) patients during their hospitalization. The predictive equation for Hb was derived using multivariate analysis. We investigated all the parameters in BIA, patients' symptom and demographic data. In this developed model, four predictors (reactance (XC), sex, weight and vomiting) were found to be the best predictive factors for modeling Hb in dengue patients. However, the model can only explain approximately 42% of the variation in Hb status, thus single frequency bio-impedance stand-alone technique is insufficient to monitor Hb for the DF and DHF patients. Further investigation using multi-frequency BIA is recommended in modeling Hb to achieve the most parsimonious model.
  2. Ibrahim F, Taib MN, Abas WA, Guan CC, Sulaiman S
    Comput Methods Programs Biomed, 2005 Sep;79(3):273-81.
    PMID: 15925426
    Dengue fever (DF) is an acute febrile viral disease frequently presented with headache, bone or joint and muscular pains, and rash. A significant percentage of DF patients develop a more severe form of disease, known as dengue haemorrhagic fever (DHF). DHF is the complication of DF. The main pathophysiology of DHF is the development of plasma leakage from the capillary, resulting in haemoconcentration, ascites, and pleural effusion that may lead to shock following defervescence of fever. Therefore, accurate prediction of the day of defervescence of fever is critical for clinician to decide on patient management strategy. To date, no known literature describes of any attempt to predict the day of defervescence of fever in DF patients. This paper describes a non-invasive prediction system for predicting the day of defervescence of fever in dengue patients using artificial neural network. The developed system bases its prediction solely on the clinical symptoms and signs and uses the multilayer feed-forward neural networks (MFNN). The results show that the proposed system is able to predict the day of defervescence in dengue patients with 90% prediction accuracy.
  3. Meau YP, Ibrahim F, Narainasamy SA, Omar R
    Comput Methods Programs Biomed, 2006 May;82(2):157-68.
    PMID: 16638620
    This study presents the development of a hybrid system consisting of an ensemble of Extended Kalman Filter (EKF) based Multi Layer Perceptron Network (MLPN) and a one-pass learning Fuzzy Inference System using Look-up Table Scheme for the recognition of electrocardiogram (ECG) signals. This system can distinguish various types of abnormal ECG signals such as Ventricular Premature Cycle (VPC), T wave inversion (TINV), ST segment depression (STDP), and Supraventricular Tachycardia (SVT) from normal sinus rhythm (NSR) ECG signal.
  4. Ibrahim F, Ooi KF, Ismail NA, Taib MN, Wan Abas WA
    Conf Proc IEEE Eng Med Biol Soc, 2007 2 7;2005:4130-3.
    PMID: 17281142
    This paper describes the water compartments in healthy subjects and dengue patients on the day of defervescence of fever using bioelectrical impedance analysis. A total of 223 healthy subjects (65 males and 158 females) and 210 dengue patients (119 males and 91 females) in Hospital Universiti Kebangsaan Malaysia (HUKM), were studied. The ages for healthy subjects vary between 14 and 60 years old with mean age of 26.05 years while the ages for the dengue patients vary between 12 and 83 years old with mean age of 30.14 years. The parameters of water compartments investigated were total body water (TBW), extracellular water (ECW) and intracellular water (ICW). There were significant difference between healthy subjects and dengue patients for both male (p<0.05) and female (p<0.001) beginning on fever day 0 till fever day 4. The mean TBW and ECW values of dengue patients obtained were found to be higher than the normal healthy subjects while the mean ICW was lower. The mean TBW and ICW for male were higher than female while the mean ECW for male was lower than female for healthy subjects and dengue patients.
  5. Faisal T, Ibrahim F, Taib MN
    PMID: 19163874 DOI: 10.1109/IEMBS.2008.4650371
    This study presents a new approach to determine the significant prognosis factors in dengue patients utilizing the self-organizing map (SOM). SOM was used to visualize and determine the significant factors that can differentiate between the dengue patients and the healthy subjects. Bioimpedance analysis (BIA) parameters and symptoms/signs obtained from the 210 dengue patients during their hospitalization were used in this study. Database comprised of 329 sample (210 dengue patients and 119 healthy subjects) were used in the study. Accordingly, two maps were constructed. A total of 35 predictors (17 BIA parameters, 18 symptoms/signs) were investigated on the day of defervescence of fever. The first map was constructed based on BIA parameters while the second map utilized the symptoms and signs. The visualized results indicated that, the significant BIA prognosis factors for differentiating the dengue patients from the healthy subjects are reactance, intracellular water, ratio of the extracellular water and intracellular water, and ratio of the extracellular mass and body cell mass.
  6. Sosroseno W, Sugiatno E, Samsudin AR, Ibrahim F
    J Oral Implantol, 2008;34(4):196-202.
    PMID: 18780564 DOI: 10.1563/0.910.1
    The aim of the present study was to test the hypothesis that the proliferation of a human osteoblast cell line (HOS cells) stimulated with hydroxyapatite (HA) may be regulated by nitric oxide (NO). The cells were cultured on the surface of HA. Medium or cells alone were used as controls. L-arginine, D-arginine, 7-NI (an nNOS inhibitor), L-NIL (an iNOS inhibitor), L-NIO (an eNOS inhibitor) or carboxy PTIO, a NO scavenger, was added in the HA-exposed cell cultures. The cells were also precoated with anti-human integrin alphaV antibody. The levels of nitrite were determined spectrophotometrically. Cell proliferation was assessed by colorimetric assay. The results showed increased nitrite production and cell proliferation by HA-stimulated HOS cells up to day 3 of cultures. Anti-integrin alphaV antibody, L-NIO, or carboxy PTIO suppressed, but L-arginine enhanced, nitrite production and cell proliferation of HA-stimulated HOS cells. The results of the present study suggest, therefore, that interaction between HA and HOS cell surface integrin alphaV molecule may activate eNOS to catalyze NO production which, in turn, may regulate the cell proliferation in an autocrine fashion.
  7. Faisal T, Taib MN, Ibrahim F
    Med Biol Eng Comput, 2010 Mar;48(3):293-301.
    PMID: 20016950 DOI: 10.1007/s11517-009-0561-x
    Even though the World Health Organization criteria's for classifying the dengue infection have been used for long time, recent studies declare that several difficulties have been faced by the clinicians to apply these criteria. Accordingly, many studies have proposed modified criteria to identify the risk in dengue patients based on statistical analysis techniques. None of these studies utilized the powerfulness of the self-organized map (SOM) in visualizing, understanding, and exploring the complexity in multivariable data. Therefore, this study utilized the clustering of the SOM technique to identify the risk criteria in 195 dengue patients. The new risk criteria were defined as: platelet count less than or equal 40,000 cells per mm(3), hematocrit concentration great than or equal 25% and aspartate aminotransferase (AST) rose by fivefold the normal upper limit for AST/alanine aminotransfansferase (ALT) rose by fivefold the normal upper limit for ALT. The clusters analysis indicated that any dengue patient fulfills any two of the risk criteria is consider as high risk dengue patient.
  8. Ibrahim F, Faisal T, Salim MI, Taib MN
    Med Biol Eng Comput, 2010 Nov;48(11):1141-8.
    PMID: 20683676 DOI: 10.1007/s11517-010-0669-z
    This paper presents a new approach to diagnose and classify early risk in dengue patients using bioelectrical impedance analysis (BIA) and artificial neural network (ANN). A total of 223 healthy subjects and 207 hospitalized dengue patients were prospectively studied. The dengue risk severity criteria was determined and grouped based on three blood investigations, namely, platelet (PLT) count (less than or equal to 30,000 cells per mm(3)), hematocrit (HCT) (increase by more than or equal to 20%), and either aspartate aminotransferase (AST) level (raised by fivefold the normal upper limit) or alanine aminotransferase (ALT) level (raised by fivefold the normal upper limit). The dengue patients were classified according to their risk groups and the corresponding BIA parameters were subsequently obtained and quantified. Four parameters were used for training and testing the ANN which are day of fever, reactance, gender, and risk group's quantification. Day of fever was defined as the day of fever subsided, i.e., when the body temperature fell below 37.5°C. The blood investigation and the BIA data were taken for 5 days. The ANN was trained via the steepest descent back propagation with momentum algorithm using the log-sigmoid transfer function while the sum-squared error was used as the network's performance indicator. The best ANN architecture of 3-6-1 (3 inputs, 6 neurons in the hidden layer, and 1 output), learning rate of 0.1, momentum constant of 0.2, and iteration rate of 20,000 was pruned using a weight-eliminating method. Eliminating a weight of 0.05 enhances the dengue's prediction risk classification accuracy of 95.88% for high risk and 96.83% for low risk groups. As a result, the system is able to classify and diagnose the risk in the dengue patients with an overall prediction accuracy of 96.27%.
  9. Hassan A, Ibrahim F
    J Digit Imaging, 2011 Apr;24(2):308-13.
    PMID: 20386951 DOI: 10.1007/s10278-010-9283-8
    This paper presents the development of kidney TeleUltrasound consultation system. The TeleUltrasound system provides an innovative design that aids the acquisition, archiving, and dissemination of medical data and information over the internet as its backbone. The system provides data sharing to allow remote collaboration, viewing, consultation, and diagnosis of medical data. The design is layered upon a standard known as Digital Imaging and Communication in Medicine (DICOM). The DICOM standard defines protocols for exchanging medical images and their associated data. The TeleUltrasound system is an integrated solution for retrieving, processing, and archiving images and providing data storage management using Structured Query Language (SQL) database. Creating a web-based interface is an additional advantage to achieve global accessibility of experts that will widely open the opportunity of greater examination and multiple consultations. This system is equipped with a high level of data security and its performance has been tested with white, black, and gray box techniques. And the result was satisfactory. The overall system has been evaluated by several radiologists in Malaysia, United Arab Emirates, and Sudan, the result is shown within this paper.
  10. Aboodarda SJ, Shariff MA, Muhamed AM, Ibrahim F, Yusof A
    J Hum Kinet, 2011 Dec;30:5-12.
    PMID: 23487250 DOI: 10.2478/v10078-011-0067-0
    This study was designed to quantify and compare Electromyographic activity (EMG) and applied load in quadriceps muscle within performing high intensity knee extension exercises by Elastic Resistance (ER) and Nautilus Machine (NM). Sixteen male and female subjects (22.4 ± 4.7 yrs) completed 8 RM seated knee extension by NM, elastic tubing with original length (E0) and elastic tubing with 30% decrement of original length (E30). The mean value of EMG and external force were calculated and synchronized across various segments of motion for the three modes of training. The results demonstrated that in the early concentric and late eccentric segments of contraction, NM elicited significantly higher muscle activation than both E30 and E0 (p < 0.05). However, in the mid-concentric and mid-eccentric as well as late concentric and early eccentric segments no significant differences were observed between NM and E30. These findings supported the approach that developing external recoil of force in ER device by reducing 30% of initial length of elastic material can offer similar neuromuscular activation compared with NM. On this basis, E30 can be suggested as an affordable and non-gym based exercise device which has the capacity to provide an appropriate high resistance stimulus to meet the training requirement of athletes.
  11. Doufesh H, Faisal T, Lim KS, Ibrahim F
    Appl Psychophysiol Biofeedback, 2012 Mar;37(1):11-8.
    PMID: 21965118 DOI: 10.1007/s10484-011-9170-1
    This study investigated the proposition of relaxation offered by performing the Muslim prayers by measuring the alpha brain activity in the frontal (F3-F4), central (C3-C4), parietal (P3-P4), and occipital (O1-O2) electrode placements using the International 10-20 System. Nine Muslim subjects were asked to perform the four required cycles of movements of Dhuha prayer, and the EEG were subsequently recorded with open eyes under three conditions, namely, resting, performing four cycles of prayer while reciting the specific verses and supplications, and performing four cycles of acted salat condition (prayer movements without any recitations). Analysis of variance (ANOVA) tests revealed that there were no significant difference in the mean alpha relative power (RP(α)) between the alpha amplitude in the Dhuha prayer and the acted conditions in all eight electrode positions. However, the mean RP(α) showed higher alpha amplitude during the prostration position of the Dhuha prayer and acted condition at the parietal and occipital regions in comparison to the resting condition. Findings were similar to other studies documenting increased alpha amplitude in parietal and occipital regions during meditation and mental concentration. The incidence of increased alpha amplitude suggested parasympathetic activation, thus indicating a state of relaxation. Subsequent studies are needed to delineate the role of mental concentration, and eye focus, on alpha wave amplitude while performing worshipping acts.
  12. Faisal T, Taib MN, Ibrahim F
    J Med Syst, 2012 Apr;36(2):661-76.
    PMID: 20703665 DOI: 10.1007/s10916-010-9532-x
    With the dramatic increase of the worldwide threat of dengue disease, it has been very crucial to correctly diagnose the dengue patients in order to decrease the disease severity. However, it has been a great challenge for the physicians to identify the level of risk in dengue patients due to overlapping of the medical classification criteria. Therefore, this study aims to construct a noninvasive diagnostic system to assist the physicians for classifying the risk in dengue patients. Systematic producers have been followed to develop the system. Firstly, the assessment of the significant predictors associated with the level of risk in dengue patients was carried out utilizing the statistical analyses technique. Secondly, Multilayer perceptron neural network models trained via Levenberg-Marquardt and Scaled Conjugate Gradient algorithms was employed for constructing the diagnostic system. Finally, precise tuning for the models' parameters was conducted in order to achieve the optimal performance. As a result, 9 noninvasive predictors were found to be significantly associated with the level of risk in dengue patients. By employing those predictors, 75% prediction accuracy has been achieved for classifying the risk in dengue patients using Scaled Conjugate Gradient algorithm while 70.7% prediction accuracy were achieved by using Levenberg-Marquardt algorithm.
  13. Samsudin S, Adwan S, Arof H, Mokhtar N, Ibrahim F
    J Digit Imaging, 2013 Apr;26(2):361-70.
    PMID: 22610151 DOI: 10.1007/s10278-012-9483-5
    Standard X-ray images using conventional screen-film technique have a limited field of view that is insufficient to show the full bone structure of large hands on a single frame. To produce images containing the whole hand structure, digitized images from the X-ray films can be assembled using image stitching. This paper presents a new medical image stitching method that utilizes minimum average correlation energy filters to identify and merge pairs of hand X-ray medical images. The effectiveness of the proposed method is demonstrated in the experiments involving two databases which contain a total of 40 pairs of overlapping and non-overlapping hand images. The experimental results are compared with that of the normalized cross-correlation (NCC) method. It is found that the proposed method outperforms the NCC method in classifying and merging the overlapping and non-overlapping medical images. The efficacy of the proposed method is further indicated by its average execution time, which is about five times shorter than that of the other method.
  14. Thio TH, Soroori S, Ibrahim F, Al-Faqheri W, Soin N, Kulinsky L, et al.
    Med Biol Eng Comput, 2013 May;51(5):525-35.
    PMID: 23292292 DOI: 10.1007/s11517-012-1020-7
    This paper presents a theoretical development and critical analysis of the burst frequency equations for capillary valves on a microfluidic compact disc (CD) platform. This analysis includes background on passive capillary valves and the governing models/equations that have been developed to date. The implicit assumptions and limitations of these models are discussed. The fluid meniscus dynamics before bursting is broken up into a multi-stage model and a more accurate version of the burst frequency equation for the capillary valves is proposed. The modified equations are used to evaluate the effects of various CD design parameters such as the hydraulic diameter, the height to width aspect ratio, and the opening wedge angle of the channel on the burst pressure.
  15. Yafouz B, Kadri NA, Ibrahim F
    Sensors (Basel), 2013 Jul 12;13(7):9029-46.
    PMID: 23857266 DOI: 10.3390/s130709029
    During the last three decades; dielectrophoresis (DEP) has become a vital tool for cell manipulation and characterization due to its non-invasiveness. It is very useful in the trend towards point-of-care systems. Currently, most efforts are focused on using DEP in biomedical applications, such as the spatial manipulation of cells, the selective separation or enrichment of target cells, high-throughput molecular screening, biosensors and immunoassays. A significant amount of research on DEP has produced a wide range of microelectrode configurations. In this paper; we describe the microarray dot electrode, a promising electrode geometry to characterize and manipulate cells via DEP. The advantages offered by this type of microelectrode are also reviewed. The protocol for fabricating planar microelectrodes using photolithography is documented to demonstrate the fast and cost-effective fabrication process. Additionally; different state-of-the-art Lab-on-a-Chip (LOC) devices that have been proposed for DEP applications in the literature are reviewed. We also present our recently designed LOC device, which uses an improved microarray dot electrode configuration to address the challenges facing other devices. This type of LOC system has the capability to boost the implementation of DEP technology in practical settings such as clinical cell sorting, infection diagnosis, and enrichment of particle populations for drug development.
  16. Thio TH, Ibrahim F, Al-Faqheri W, Moebius J, Khalid NS, Soin N, et al.
    Lab Chip, 2013 Aug 21;13(16):3199-209.
    PMID: 23774994 DOI: 10.1039/c3lc00004d
    A technique known as thermo-pneumatic (TP) pumping is used to pump fluids on a microfluidic compact disc (CD) back towards the CD center against the centrifugal force that pushes liquids from the center to the perimeter of the disc. Trapped air expands in a TP air chamber during heating, and this creates positive pressure on liquids located in chambers connected to that chamber. While the TP air chamber and connecting channels are easy to fabricate in a one-level CD manufacturing technique, this approach provides only one way pumping between two chambers, is real-estate hungry and leads to unnecessary heating of liquids in close proximity to the TP chamber. In this paper, we present a novel TP push and pull pumping method which allows for pumping of liquid in any direction between two connected liquid chambers. To ensure that implementation of TP push and pull pumping also addresses the issue of space and heating challenges, a multi-level 3D CD design is developed, and localized forced convection heating, rather than infra-red (IR) is applied. On a multi-level 3D CD, the TP features are placed on a top level separate from the rest of the microfluidic processes that are implemented on a lower separate level. This approach allows for heat shielding of the microfluidic process level, and efficient usage of space on the CD for centrifugal handling of liquids. The use of localized forced convection heating, rather than infra-red (IR) or laser heating in earlier implementations allows not only for TP pumping of liquids while the CD is spinning but also makes heat insulation for TP pumping and other fluidic functions easier. To aid in future implementations of TP push and pull pumping on a multi-level 3D CD, study on CD surface heating is also presented. In this contribution, we also demonstrate an advanced application of pull pumping through the implementation of valve-less switch pumping.
  17. Ibrahim F, Sian TC, Shanggar K, Razack AH
    J Phys Ther Sci, 2013 Sep;25(9):1087-91.
    PMID: 24259921 DOI: 10.1589/jpts.25.1087
    [Purpose] Our objective was to assess the effect of salat and mimicking salat movements and postures on subjects with erectile dysfunction. [Methods] Ten volunteers were recruited in this study. Subjects who were Muslims (Group I) were asked to perform their daily salat and a new intervention of an additional 12 movement cycles of salat for three sessions a week. Non-Muslim subjects (Group II) were taught to mimic salat movements, and were asked to perform a total of 12 movement cycles without reading the recitation for three sessions a week. An International Index for Erectile Function 5 (IIEF-5) questionnaire was given to the subjects before and after the intervention of performing salat or mimicking salat movements and postures. A nocturnal electrobioimpedance volume assessment (NEVA) device was used to measure the nocturnal penile tumescence (NPT) parameters over two consecutive nights. A nonparametric test was conducted to find the significant NPT parameters. [Results] The results showed that all measured parameters improved significantly, with the largest change observed in the maximum percent volumetric change over the baseline (from 138 to 222%). [Conclusion] This preliminary study suggests that the alternative approach of salat and mimicking salat movements and postures, may have beneficial effects for ED patients.
  18. Mohktar MS, Ibrahim F, Mohd Rozi NF, Mohd Yusof J, Ahmad SA, Su Yen K, et al.
    Med Sci Monit, 2013 Dec 13;19:1159-66.
    PMID: 24335927 DOI: 10.12659/MSM.889628
    BACKGROUND: Currently, the reference standard used to clinically assess sexual function among women is a qualitative questionnaire. Hence, a generalised and quantitative measurement tool needs to be available as an alternative. This study investigated whether an electromyography (EMG) measurement technique could be used to help quantify women's sexual function.

    MATERIAL AND METHODS: A preliminary intervention study was conducted on 12 female subjects, who were randomised into a control (n=6) and an intervention (n=6) group. Intervention involved a set regimen of pelvic floor muscle exercises (Kegel) and the control group did not have any treatment. All subjects were asked to answer a validated, self-rated Pelvic Organ Prolapse/Urinary Incontinence Sexual Function Questionnaire (PISQ). EMG measurements of the pelvic floor muscles (PFM) and the abdominal muscles were taken from all women at recruitment and 8 weeks after study commencement.

    RESULTS: After 8 weeks, most of the subjects in the control group did not display any noted positive difference in either PISQ score (4/6) or in their muscle strength (4/6). However, a noted progressive difference were observed in subjects who were placed in the Kegel group; PISQ score (5/6) and muscles strength (4/6).

    CONCLUSIONS: The noted difference in the Kegel group subjects was that if progress is observed in the sexual function, improvement is also observed in the strength of at least 2 types of muscles (either abdominal or PFM muscles). Thus, EMG measurement is a potential technique to quantify the changes in female sexual function. Further work will be conducted to validate this assumption.

  19. Kazemzadeh A, Ganesan P, Ibrahim F, He S, Madou MJ
    PLoS One, 2013;8(9):e73002.
    PMID: 24069169 DOI: 10.1371/journal.pone.0073002
    This paper employs the volume of fluid (VOF) method to numerically investigate the effect of the width, height, and contact angles on burst frequencies of super hydrophilic and hydrophilic capillary valves in centrifugal microfluidic systems. Existing experimental results in the literature have been used to validate the implementation of the numerical method. The performance of capillary valves in the rectangular and the circular microfluidic structures on super hydrophilic centrifugal microfluidic platforms is studied. The numerical results are also compared with the existing theoretical models and the differences are discussed. Our experimental and computed results show a minimum burst frequency occurring at square capillaries and this result is useful for designing and developing more sophisticated networks of capillary valves. It also predicts that in super hydrophilic microfluidics, the fluid leaks consistently from the capillary valve at low pressures which can disrupt the biomedical procedures in centrifugal microfluidic platforms.
  20. Al-Faqheri W, Ibrahim F, Thio TH, Moebius J, Joseph K, Arof H, et al.
    PLoS One, 2013;8(3):e58523.
    PMID: 23505528 DOI: 10.1371/journal.pone.0058523
    This paper introduces novel vacuum/compression valves (VCVs) utilizing paraffin wax. A VCV is implemented by sealing the venting channel/hole with wax plugs (for normally-closed valve), or to be sealed by wax (for normally-open valve), and is activated by localized heating on the CD surface. We demonstrate that the VCV provides the advantages of avoiding unnecessary heating of the sample/reagents in the diagnostic process, allowing for vacuum sealing of the CD, and clear separation of the paraffin wax from the sample/reagents in the microfluidic process. As a proof of concept, the microfluidic processes of liquid flow switching and liquid metering is demonstrated with the VCV. Results show that the VCV lowers the required spinning frequency to perform the microfluidic processes with high accuracy and ease of control.
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links