Displaying publications 1 - 20 of 25 in total

Abstract:
Sort:
  1. Al-Majhali SH, Khairuddin NH, Abdul Razak IS, Radzi Z, Rahman MT, Sapalo JT, et al.
    J Equine Vet Sci, 2021 04;99:103399.
    PMID: 33781409 DOI: 10.1016/j.jevs.2021.103399
    The use of a self-inflating tissue expander is a technique to stretch cutaneous tissues for potential use in reconstructive skin surgeries. This study investigates the mechanical properties of horse skin stretched by the subcutaneous implantation of anisotropic tissue expanders at the forehead, right shoulder, and dorsomedial part of the cannon region of the right forelimb in six (n = 6) horses. After 14 days of skin expansion, expanded and normal (control) skin samples were harvested and their mechanical properties of elastic modulus (EM), maximum force (MF), maximum stress (MSs) and maximum strain (MSr) were evaluated using uniaxial tension test. The expanded skin from shoulder area has higher EM, MSs, MSr and MF than the normal skin when compared to the forehead and lower forelimb. Statistically, there was a significant (P= .02) mean difference for MSs between the expanded shoulder and lower forelimb skin, but the pairwise comparison of EM, MSr and MF showed no significant difference between the locations. The overall effect of locations on EM and MSs was statistically significant (P < .05), however, there was no overall effect of horse factor, treatment factor (normal and expanded skin) and location interaction on the EM, MSS, MF and MSr. In conclusion, the expanded skin from the frontal head and the distal limb are less elastic (stiffer) compared to that of the expanded skin of the shoulder, thus anatomical location of the skin has some degree of effect on EM and MSs.
  2. Ali AK, Abubakar AA, Kaka U, Radzi Z, Khairuddin NH, Yusoff MSM, et al.
    Vet World, 2018 Dec;11(12):1706-1711.
    PMID: 30774262 DOI: 10.14202/vetworld.2018.1706-1711
    Aim: Tissue expansion is an applicable technique to reconstruct many surgical defects. The aim of this research was to evaluate the histological changes caused by immediate skin tissue expansion in rats as an animal model.

    Materials and Methods: Immediate skin tissue expansion in 18 adult female rats was performed using three different sizes (small, medium, and big) of polymethylmethacrylate tissue expanders at the dorsal surface of the metatarsal area of the right limb. The contralateral limb was served as the control. The tissue expanders were surgically implanted and kept for 15 days.

    Results: The immediate skin expansion resulted in histological changes such as the increased thickness of the epidermal layer, the reduction of the dermal layer, an elevated number of fibroblast as well as increased vascularity. Furthermore, skin adnexal structures such as hair follicles and sebaceous glands were farther apart.

    Conclusion: The rat skin was able to rapidly adjust and compensate against a specific range of immediate mechanical expansion. The histological changes suggest that the tissues were prepared to withstand the increased external forces, in addition to create possibly additional skin in a relatively short-term period.

  3. Ali Salim KM, Abd Jalil A, Radzi Z, Ismail SM, Czernuszka JT, Rahman MT
    Materials (Basel), 2020 Oct 06;13(19).
    PMID: 33036128 DOI: 10.3390/ma13194436
    OBJECTIVE: Reconstruction of oral and facial defects often necessitate replacement of missing soft tissue. The purpose of tissue expanders is to grow healthy supplementary tissue under a controlled force. This study investigates the inflammatory responses associated with the force generated from the use of anisotropic hydrogel tissue expanders.

    METHODS: Sprague Dawley rats (n = 7, body weight = 300 g ± 50 g) were grouped randomly into two groups-control (n = 3) and expanded (n = 4). Anisotropic hydrogel tissue expanders were inserted into the frontal maxillofacial region of the rats in the expanded group. The rats were sacrificed, and skin samples were harvested, fixed in formalin, and embedded in paraffin wax for histological investigation. Hematoxylin and eosin staining was performed to detect histological changes between the two groups and to investigate the inflammatory response in the expanded samples. Three inflammatory markers, namely interleukin (IL)-1α, IL-6, and tumor necrosis factor-α (TNF-α), were analyzed by immunohistochemistry.

    RESULT: IL-1-α expression was only observed in the expanded tissue samples compared to the controls. In contrast, there was no significant difference in IL-6, and TNF-α production. Histological analysis showed the absence of inflammatory response in expanded tissues, and a negative non-significant correlation (Spearman's correlation coefficient) between IL-1-α immune-positive cells and the inflammatory cells (r = -0.500). In conclusion, tissues that are expanded and stabilized using an anisotropic self-inflating hydrogel tissue expander might be useful for tissue replacement and engraftment as the expanded tissue does not show any sign of inflammatory responses. Detection of IL-1-α in the expanded tissues warrants further investigation for its involvement without any visible inflammatory response.

  4. Alyessary AS, Yap AU, Othman SA, Rahman MT, Al-Namnam NM, Radzi Z
    J Orofac Orthop, 2018 May;79(3):169-179.
    PMID: 29644389 DOI: 10.1007/s00056-018-0134-4
    OBJECTIVE: Accelerated bone-borne expansion protocols on sutural separation and sutural bone formation were evaluated via histomorphometry and immunohistochemistry to determine the optimal initial activation without disruption of bone formation.

    MATERIALS AND METHODS: Sixteen New Zealand white rabbits were randomly divided into four groups. Modified Hyrax expanders were placed across the midsagittal sutures and secured with miniscrew implants with the following activations: group 1 (control), 0.5 mm expansion/day for 12 days; group 2, 1 mm instant expansion followed by 0.5 mm expansion/day for 10 days; group 3, 2.5 mm instant expansion followed by 0.5 mm expansion/day for 7 days; and group 4, 4 mm instant expansion followed by 0.5 mm expansion/day for 4 days. After 6 weeks, sutural expansion and new bone formation were evaluated histomorphometrically. Statistical analysis was performed using Kruskal-Wallis/Mann-Whitney U tests and Spearman's rho correlation (p 

  5. Alyessary AS, Yap AUJ, Othman SA, Ibrahim N, Rahman MT, Radzi Z
    Am J Orthod Dentofacial Orthop, 2018 Aug;154(2):260-269.
    PMID: 30075928 DOI: 10.1016/j.ajodo.2017.11.031
    INTRODUCTION: In this study, we evaluated the effect of bone-borne accelerated expansion protocols on sutural separation and sutural bone modeling using a microcomputed tomography system. We also determined the optimum instant sutural expansion possible without disruption of bone modeling.

    METHODS: Sixteen New Zealand white rabbits, 20 to 24 weeks old, were randomly divided into 4 experimental groups. Modified hyrax expanders were placed across their interfrontal sutures and secured with miniscrew implants located bilaterally in the frontal bone. The hyrax appliances were activated as follows: group 1 (control), 0.5-mm per day expansion for 12 days; group 2, 1-mm instant expansion followed by 0.5 mm per day for 10 days; group 3, 2.5-mm instant expansion followed by 0.5 mm per day for 7 days, and group 4, 4-mm instant expansion followed by 0.5 mm per day for 4 days. After 6 weeks of retention, sutural separation and sutural bone modeling were assessed by microcomputed tomography and quantified. Statistical analysis was performed using Kruskal Wallis and Mann-Whitney U tests and the Spearman rho correlation (P <0.05).

    RESULTS: Median amounts of sutural separation ranged from 2.84 to 4.41 mm for groups 1 and 4, respectively. Median bone volume fraction ranged from 59.96% to 69.15% for groups 4 and 3, respectively. A significant correlation (r = 0.970; P <0.01) was observed between the amounts of instant expansion and sutural separation.

    CONCLUSIONS: Pending histologic verifications, our findings suggest that the protocol involving 2.5 mm of instant expansion followed by 0.5 mm per day for 7 days is optimal for accelerated sutural expansion. When 4 mm of instant expansion was used, the sutural bone volume fraction was decreased.

  6. Alyessary AS, Othman SA, Yap AUJ, Radzi Z, Rahman MT
    Int Orthod, 2019 03;17(1):12-19.
    PMID: 30732977 DOI: 10.1016/j.ortho.2019.01.001
    OBJECTIVE: This systematic review aims to determine the effects of non-surgical rapid maxillary expansion (RME) on breathing and upper airway structures.

    MATERIALS AND METHODS: An electronic search of the scientific literature from January 2005 to June 2016 was done using Web of Science, Dentistry & Oral Sciences Source and PubMed databases. A combination of search terms "rapid maxillary expansion", "nasal", "airway" and "breathing" were used. Studies that involved surgical or combined RME-surgical treatments and patients with craniofacial anomalies were excluded.

    RESULTS: The initial screening yielded a total of 183 articles. After evaluation of the titles, abstracts and accessing the full text, a total of 20 articles fulfilled both inclusion/exclusion criteria and possessed adequate evidence to be incorporated into this review.

    CONCLUSIONS: Non-surgical RME was found to improve breathing, increase nasal cavity geometry and decrease nasal airway resistance in children and adolescents.

  7. Alyessary AS, Yap AUJ, Othman SA, Rahman MT, Radzi Z
    J Oral Maxillofac Surg, 2018 03;76(3):616-630.
    PMID: 28893543 DOI: 10.1016/j.joms.2017.08.018
    PURPOSE: The present study investigated the effect of piezoelectric sutural ostectomies on accelerated bone-borne sutural expansion.

    MATERIALS AND METHODS: Sixteen male New Zealand white rabbits (20 to 24 weeks old) were randomly divided into 4 experimental groups (n = 4): group 1, conventional rapid sutural expansion; group 2, accelerated sutural expansion; group 3, accelerated sutural expansion with continuous ostectomy; and group 4, accelerated sutural expansion with discontinuous ostectomy. All sutural ostectomies were performed using a piezoelectric instrument (Woodpecker DTE, DS-II, Guangxi, China) before expander application with the rabbits under anesthesia. Modified hyrax expanders were placed across the midsagittal sutures of the rabbits and secured with miniscrew implants located bilaterally in the frontal bone. The hyrax expanders were activated 0.5 mm/day for 12 days (group 1) or with a 2.5-mm initial expansion, followed by 0.5 mm/day for 7 days (groups 2 to 4). After 6 weeks of retention, the bone volume fraction, sutural separation, and new bone formation were evaluated using micro-computed tomography and histomorphometry. Statistical analysis was performed using Kruskal-Wallis and Mann-Whitney U tests and Spearman's rho correlation (P 

  8. Aziz J, Shezali H, Radzi Z, Yahya NA, Abu Kassim NH, Czernuszka J, et al.
    Skin Pharmacol Physiol, 2016;29(4):190-203.
    PMID: 27434176 DOI: 10.1159/000447017
    Collagen and elastin networks make up the majority of the extracellular matrix in many organs, such as the skin. The mechanisms which are involved in the maintenance of homeostatic equilibrium of these networks are numerous, involving the regulation of genetic expression, growth factor secretion, signalling pathways, secondary messaging systems, and ion channel activity. However, many factors are capable of disrupting these pathways, which leads to an imbalance of homeostatic equilibrium. Ultimately, this leads to changes in the physical nature of skin, both functionally and cosmetically. Although various factors have been identified, including carcinogenesis, ultraviolet exposure, and mechanical stretching of skin, it was discovered that many of them affect similar components of regulatory pathways, such as fibroblasts, lysyl oxidase, and fibronectin. Additionally, it was discovered that the various regulatory pathways intersect with each other at various stages instead of working independently of each other. This review paper proposes a model which elucidates how these molecular pathways intersect with one another, and how various internal and external factors can disrupt these pathways, ultimately leading to a disruption in collagen and elastin networks.
  9. Aziz J, Ahmad MF, Rahman MT, Yahya NA, Czernuszka J, Radzi Z
    Int J Biol Macromol, 2018 Feb;107(Pt A):1030-1038.
    PMID: 28939521 DOI: 10.1016/j.ijbiomac.2017.09.066
    Successful use of tissue expanders depends on the quality of expanded tissue. This study evaluates the impact of anisotropic self-inflating tissue expander (SITE) on the biomechanics of skin. Two different SITE were implanted subcutaneously on sheep scalps; SITE that requires 30days for maximum expansion (Group A; n=5), and SITE that requires 21days for maximum expansion (Group B; n=5). Control animals (n=5) were maintained without SITE implantation. Young's Modulus, D-periodicity, overlap and gap region length, diameter, and height difference between overlap and gap regions on collagen fibrils were analyzed using atomic force microscopy. Histology showed no significant differences in dermal thickness between control and expanded skin of groups A and B. Furthermore, most parameters of expanded skin were similar to controls (p>0.05). However, the height difference between overlap and gap regions was significantly smaller in group B compared to both control and group A (p<0.01). Strong correlation was observed between Young's Modulus of overlap and gap regions of the control and group A, but not group B. Results suggest that a relatively slower SITE can be useful in reconstructive surgery to maintain the biomechanical properties of expanded skin.
  10. Chang, S.V., Ooi, X.D., Ismail, S.M., Rahman, M.T., Radzi, Z.
    Ann Dent, 2017;24(2):9-15.
    MyJurnal
    The information of biomechanical properties is crucial in the study of biological tissue and its clinical relevance. 3mm x 3mm free gingival human tissues was taken using disposable punch biopsy (Accu sharp blade, India) and stored in 0°C Freezer. The sample was sectioned to a thickness of 10μm using high profile microtome blade (Leica 818, Germany) and cryostat (Leica CM1850UV, United Kingdom). The sample was analysed using Atomic Force Microscope (Nanowizard® 3, JPK Instruments, Germany) at room atmosphere. The collagen fibrils of the free gingival tissues appeared to be stacked in basket weave like structure. The mean value of free gingival collagen fibrils width and the length of D-band were 106.71±11.18nm and 65.82 ± 3.04nm respectively. The Young’s modulus of collagen fibrils for human free gingival tissue at overlap region was 212.88 ± 242.58 MPa, whereas at the gap region was 207.00 ± 230.71 MPa. Within the limitation of the study, the collagen fibrils appeared to be stacked in basket weavelike structure. The length and width of the collagen fibril were similar to the values investigated using other techniques. There was significant linear relationship between Young’s modulus of overlap and gap regions.
  11. Lee WY, Lau MN, Soh EX, Yuen SW, Ashari A, Radzi Z
    BMC Oral Health, 2023 Dec 19;23(1):1015.
    PMID: 38115099 DOI: 10.1186/s12903-023-03762-w
    BACKGROUND: Epworth Sleepiness Scale for Children and Adolescents (ESS-CHAD) is a valid and reliable eight-item self-administered questionnaire for the assessment of excessive daytime sleepiness and is commonly used to screen sleep-disordered breathing for children and adolescents. The cross-sectional study aimed to translate and cross-culturally adapt ESS-CHAD into a Malay version of Epworth Sleepiness Scale for Children and Adolescents (MESS-CHAD) for the Malaysian population, and to assess the validity and reliability of MESS-CHAD.

    METHODS: Forward-backward translation method was used to translate and cross-culturally adapt ESS-CHAD. Three linguistic experts and two paediatricians content validated the translated version. Face validity was conducted through audio-recorded semi-structured in-depth interviews with 14 native Malay-speaking children and adolescents followed by thematic analysis. The revised questionnaire was then proofread by a linguistic expert. A total of 40 subjects answered the MESS-CHAD twice, 2 weeks apart, for test-retest reliability and internal consistency. For criterion validity, 148 eligible subjects and their parents answered MESS-CHAD and the Malay version of Sleep-Related Breathing Disorder scale extracted from the Paediatric Sleep Questionnaire (M-PSQ:SRBD) concurrently. Variance Inflation Factor (VIF) and P values of the model's outer weight and outer loading were analysed using SmartPLS software to assess the indicator's multicollinearity and significance for formative construct validity.

    RESULTS: Intraclass Correlation Coefficient (ICC) ranging from 0.798 to 0.932 and Cronbach's alpha ranging from 0.813 to 0.932 confirmed good to excellent test-retest reliability and internal consistency, respectively. Spearman Correlation Coefficient value of 0.789 suggested a very strong positive correlation between MESS-CHAD and M-PSQ:SRBD. VIF ranging from 1.109 to 1.455 indicated no collinearity problem. All questionnaire items in MESS-CHAD were retained as the P value of either outer model weight or outer model loading was significant (P 

  12. Manssor NA, Radzi Z, Yahya NA, Mohamad Yusof L, Hariri F, Khairuddin NH, et al.
    Skin Pharmacol Physiol, 2016;29(2):55-62.
    PMID: 26836267 DOI: 10.1159/000431328
    Mechanical properties of expanded skin tissue are different from normal skin, which is dependent mainly on the structural and functional integrity of dermal collagen fibrils. In the present study, mechanical properties and surface topography of both expanded and nonexpanded skin collagen fibrils were evaluated. Anisotropic controlled rate self-inflating tissue expanders were placed beneath the skin of sheep's forelimbs. The tissue expanders gradually increased in height and reached equilibrium in 2 weeks. They were left in situ for another 2 weeks before explantation. Expanded and normal skin samples were surgically harvested from the sheep (n = 5). Young's modulus and surface topography of collagen fibrils were measured using an atomic force microscope. A surface topographic scan showed organized hierarchical structural levels: collagen molecules, fibrils and fibers. No significant difference was detected for the D-banding pattern: 63.5 ± 2.6 nm (normal skin) and 63.7 ± 2.7 nm (expanded skin). Fibrils from expanded tissues consisted of loosely packed collagen fibrils and the width of the fibrils was significantly narrower compared to those from normal skin: 153.9 ± 25.3 and 106.7 ± 28.5 nm, respectively. Young's modulus of the collagen fibrils in the expanded and normal skin was not statistically significant: 46.5 ± 19.4 and 35.2 ± 27.0 MPa, respectively. In conclusion, the anisotropic controlled rate self-inflating tissue expander produced a loosely packed collagen network and the fibrils exhibited similar D-banding characteristics as the control group in a sheep model. However, the fibrils from the expanded skin were significantly narrower. The stiffness of the fibrils from the expanded skin was higher but it was not statistically different.
  13. Muhammad AMA, Ibrahim N, Ahmad R, Asif MK, Radzi Z, Zaini ZM, et al.
    BMC Oral Health, 2020 02 10;20(1):48.
    PMID: 32041589 DOI: 10.1186/s12903-020-1035-7
    BACKGROUND: Cone Beam Computed Tomography (CBCT) is a reliable radiographic modality to assess trabecular bone microarchitecture. The aim of this study was to determine the effect of CBCT image reconstruction parameters, namely, the threshold value and reconstruction voxel size, on trabecular bone microstructure assessment.

    METHODS: Five sectioned maxilla of adult Dorper male sheep were scanned using a CBCT system with a resolution of 76 μm3 (Kodak 9000). The CBCT images were reconstructed using different reconstruction parameters and analysed. The effect of reconstruction voxel size (76, 100 and 200 μm3) and threshold values (±15% from the global threshold value) on trabecular bone microstructure measurement was assessed using image analysis software (CT analyser version 1.15).

    RESULTS: There was no significant difference in trabecular bone microstructure measurement between the reconstruction voxel sizes, but a significant difference (Tb.N = 0.03, Tb.Sp = 0.04, Tb.Th = 0.01, BV/TV = 0.00) was apparent when the global threshold value was decreased by 15%.

    CONCLUSIONS: Trabecular bone microstructure measurements are not compromised by changing the CBCT reconstruction voxel size. However, measurements can be affected when applying a threshold value of less than 15% of the recommended global value.

  14. Radzi, Z., Yahya, N.A.
    Ann Dent, 2005;12(1):-.
    MyJurnal
    Breast-feeding offers many benefits to the baby and the mother. For instance, breast milk provides the right balance of nutrients to help an infant grow into a strong and healthy toddler. Even though breastfeeding is a natural process, it is not always easy. In certain situations, some mothers are unable to breastfeed their babies or the babies are unable to adapt to breastfeeding. This will lead to the use of bottle-feeding. The effect of breast-feeding and bottle-feeding on physical growth has been well established but less has been concentrated on the craniofacial growth and dental development. This review reveals the effects of breast-feeding and bottle-feeding on craniofacial growth and dentoalveolar development based on the available literature.
  15. Radzi, Z., Yahya, N.A., Zamzam, N., Spencer, R.J.
    Ann Dent, 2004;11(1):-.
    MyJurnal
    Missing teeth can be due to hypodontia, trauma or extraction. In general, the options for treatment depend on the severity of the hypodontia and the severity of the malocclusion. Occasionally, the space from missing teeth has to be maintained for prosthetic replacement and require an orthodontic/restorative approach. It is very important to ensure the space maintained is adequate for aesthetic reason so that it can be replaced with a prosthesis after the orthodontic treatment is completed. This article discusses a new innovation and clinical technique for maintaining this space during orthodontic treatment by using an acrylic tooth with several modifications. This innovation will be illustrated using two cases.
  16. Radzi, Z., Yahya, N.A., Zamzam, N., Wood, D.J.
    Ann Dent, 2004;11(1):-.
    MyJurnal
    Choosing the right light-curing unit can be a very difficult task for some orthodontists. Currently, there are various types of light curing units available in the market with various trade names and specifications. Most of the time information regarding light curing units is obtained from advertisements, websites or manufacturers’ catalogues. Sometimes such information can be misleading. This article attempts to provide several tips for orthodontists in selecting light curing units.
  17. Radzi, Z., Yahya, N.A., Kasim, N.H.A., Ismail, N.H., Ismail, N.A., Zamzam, N
    Ann Dent, 2006;13(1):18-23.
    MyJurnal
    Introduction: Owing to the variety of materials and methods employed, comparison of the results and findings from bonding studies is difficult. Until recently, several types of teeth have been used in published research papers as a substrate in orthodontic bonding research including bovine incisors, fresh and rebonded human premolars. Objectives: The purpose of this study was to compare the shear bond strength of an adhesive bonded to different tooth surfaces (human premolar, bovine incisor and rebonded human premolar). Methods: Two groups of thirty premolar teeth and one group of bovine incisors had brackets attached in a standardized manner using Transbond XT (3M Unitek). The adhesive was cured using conventional halogen light and a specially designed tool to standardize the distance between the light curing tip and the adhesive. The debonding force was measured using Instron universal testing machine. ANOVA and Post Hoc Dunnett C test were performed to determine any significant difference among groups (p
  18. Radzi, Z., Abu Kasim, N.H., Yahya, N.A., Abu Osman, N.A., Kassim, N.L.
    Ann Dent, 2008;15(1):33-39.
    MyJurnal
    The purpose of this study was to investigate the light intensity of selected light curing units with varying distance and angulation of the light curing tip and lightmeter. Materials and method: Four types of light units; Spectrum 800 (Dentsply), Coltulux 3 (Coltene), Elipar FreeLight 2 (3M Espe) and Starlight Pro (Mectron) were evaluated for light intensity at various distances between the light curing tip and the radiometer Cure Rite Denstply (0,1,3,5,10 and 15 mm). The light curing units were tested at right angles to the aperture of the light meter and at the angles of 45°, 60° to it at a standardized 5 mm distance. Results: The highest light intensity was obtained when the tip of light curing unit was in contact with the lightmeter aperture. The light intensity decreased significantly when the light tip was placed 5mm, 10mm and 15mm away from the lightmeter aperture. However, no significant differences (p> .05) were detected between Omm, Imm and 3mm. There was a decrease in light intensity when light~·tip was angulated at 45° and 60° except for Coltolux 3. Conclusions: The intensity of the curing light was affected by the distance between the light curing tip and the lightmeter. However, the decrease in light intensity of the light curing unit was found not to obey the inverse square law for the distances 0 to 15 mm. The study found that there was no significant difference between 45° and 60° angulation between the light curing tip and the lightmeter. However, the decrease in light intensity was significant when compared to the light tip placed perpendicular (90°) to the aperture of the light meter.
  19. Tang, Y.C., Peh, X.L., Zakaria, N.N., Radzi, Z.
    Ann Dent, 2016;23(1):1-12.
    MyJurnal
    The study aimed to compare mechanical properties and surface characteristics of initial and working
    aesthetic archwires with their conventional counterparts. High Aesthetic Sentalloy (full rhodium coating
    nickel-titanium; Dentsply GAC) represented the initial aesthetic archwires; and FLI TRU-CHROME
    (labial PTFE-coated stainless steel; RMO) as the working aesthetic archwires; together with their
    conventional counterparts were analysed. A three point bending test was conducted using a universal
    testing machine (AGS-X SERIES, Shimadzu, Japan) to determine the load-deflection characteristics of
    archwires. Surface hardness was evaluated by Vickers microhardness test (HMV-FA, Shimadzu, Japan).
    A 3D Optical Surface Texture Analyzer (ALICONA, InfiniteFocus Real3D, Belgium) and a Field Emission
    Scanning Electron Microscope (FESEM, FEI Quanta 250, USA) were used for surface evaluation.
    Results showed that load-deflection characteristics of High Aesthetic Sentalloy archwires did not differ
    from its control, whereas FLI TRU-CHROME archwires exhibited higher loading and unloading forces
    than its counterpart. No statistically significant difference in surface hardness was found between FLI
    TRU-CHROME and its control archwires. The coating surfaces of both aesthetic archwires were rougher
    than the non-coated conventional archwires, with similar roughness between non-coated surface of FLI
    TRU-CHROME archwires and its counterpart. FLI TRU-CHROME archwires showed a distinct coating
    thickness but coating layer is undefined in High Aesthetic Sentalloy archwires. In conclusion, the aesthetic
    rhodium coated nickel titanium archwire has similar mechanical properties as control nickel titanium
    archwire without being adversely affected by the addition of the coating layer. The aesthetic coated PTFE
    stainless steel archwire has higher load response which could be an advantage as rigid wire in working
    stage of orthodontic treatment. Based on their performance, their use could be recommended in cases
    where aesthetic aspect is crucial and where the friction aspect is not critical as their surface roughness
    values increased.
  20. Tripathy A, Pramanik S, Manna A, Shah NF, Shasmin HN, Radzi Z, et al.
    Sensors (Basel), 2016;16(3):292.
    PMID: 26927116 DOI: 10.3390/s16030292
    Armalcolite, a rare ceramic mineral and normally found in the lunar earth, was synthesized by solid-state step-sintering. The in situ phase-changed novel ceramic nanocrystals of Ca-Mg-Ti-Fe based oxide (CMTFOx), their chemical reactions and bonding with polydimethylsiloxane (PDMS) were determined by X-ray diffraction, infrared spectroscopy, and microscopy. Water absorption of all the CMTFOx was high. The lower dielectric loss tangent value (0.155 at 1 MHz) was obtained for the ceramic sintered at 1050 °C (S1050) and it became lowest for the S1050/PDMS nanocomposite (0.002 at 1 MHz) film, which was made by spin coating at 3000 rpm. The excellent flexibility (static modulus ≈ 0.27 MPa and elongation > 90%), viscoelastic property (tanδ = E″/E': 0.225) and glass transition temperature (Tg: -58.5 °C) were obtained for S1050/PDMS film. Parallel-plate capacitive and flexible resistive humidity sensors have been developed successfully. The best sensing performance of the present S1050 (3000%) and its flexible S1050/PDMS composite film (306%) based humidity sensors was found to be at 100 Hz, better than conventional materials.
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links