AIMS: Our objective was to compare and assess the correlation between the changes in capnographic indices and peak flow measurement in non-intubated acute asthmatic patients attending the emergency room.
METHODS: We carried out a prospective study in a university hospital emergency department (ED). One hundred and twenty eight patients with acute asthma were monitored with peak flow measurements and then had a nasal cannula attached for microstream sampling of expired carbon dioxide. The capnographic waveform was recorded onto a PC card for indices analysis. The patients were treated according to departmental protocols. After treatment, when they were adjudged well for discharge, a second set of results was obtained for peak flow measurements and capnographic waveform recording. The pre-treatment and post-treatment results were then compared with paired samples t-test analysis. Simple and canonical correlations were performed to determine correlations between the assessment methods. A p value of below 0.05 was taken to be significant.
RESULTS: Peak flow measurements showed significant improvements post-treatment (p < 0.001). On the capnographic waveform, there was a significant difference in the slope of phase 3 (p < 0.001) and alpha angle (p < 0.001), but not in phase 2 slope (p = 0.35). Correlation studies done between the assessment methods and indices readings did not show strong correlations either between the measurements or the magnitude of change pre-treatment and post-treatment.
CONCLUSION: Peak flow measurements and capnographic waveform indices can indicate improvements in airway diameter in acute asthmatics in the ED. Even though the two assessment methods did not correlate statistically, capnographic waveform analysis presents several advantages in that it is effort independent and provides continuous monitoring of normal tidal respiration. They can be proposed for the monitoring of asthmatics in the ED.
Methods: Septic patient with hyperlactatemia and metabolic acidosis were randomized to receive either high SID fl uid or Hartmann's solution during initial fl uid resuscitation. The primary outcome measures the pH and bicarbonate levels difference pre- and post- resuscitation.
Results: One hundred and sixty-two patients underwent randomization, 81 were assigned each to receive high SID fluid or Hartmann's solution. Both groups had similar baseline characteristics. High SID group received 23.5 mL/kg and the Hartmann's group received 22.7 mL/kg (p = 0.360). High SID fluid increased the mean (± SD) pH by 0.107 (± 0.09) vs. Hartmann's solution by 0.014 (± 0.12), p ≤ 0.001. Mean bicarbonate level increased signifi cantly in high SID group compared to Hartmann's (4.30 ± 3.76 vs. 1.25 ± 3.33, p ≤ 0.001). High SID group had higher post resuscitation lactate clearance than Hartmann's group (25.4 ± 28.3% vs. 12.0 ± 34.1%, p = 0.009). Shorter hospital stay was observed in highSID group 8.04 ± 5.96 days vs. Hartmann's group 12.18 ± 12.41 days (p = 0.048). Both groups showed no difference in incidence of pulmonary oedema, acute kidney injury and mortality.
Conclusions: Initial resuscitation using high SID fluid in selected septic patient improves pH and bicarbonate levels. The high SID group had better post resuscitation lactate clearance and shorter hospital stay.
Methods: A child-sized mannequin head was developed to measure light illuminance levels with and without sun-protective equipment, across a wide range of environments in Singapore, outdoors (open park, under a tree, street) and indoors (under a fluorescent illumination with window, under white LED-based lighting without window). A comparison was made between indoor and outdoor light levels that are experienced while children are involved in day-to-day activities.
Results: Outdoor light levels were much higher (11,080-18,176 lux) than indoors (112-156 lux). The higher lux levels protective of myopia (>1000 lux) were measured at the tree shade (5556-7876 lux) and with hat (4112-8156 lux). Sunglasses showed lux levels between 1792 and 6800 lux. Although with sunglasses readings were lower than tree shade and hat, light levels were still 11 to 43 times higher than indoors.
Conclusions: Recommendations on spending time outdoors for myopia prevention with adequate sun protection should be provided while partaking in outdoor activities, including protection under shaded areas, wearing a hat or sunglasses, sunscreen, and adequate hydration.
Translational Relevance: Light levels outdoors were higher than indoors and above the threshold illuminance for myopia prevention even with adequate sun-protective measures.