METHOD: A total of 336 and 616 acoustic tokens were collected from six CI and 11 NH Malay children, respectively. The groups were matched for hearing age and duration of exposure to Arabic sounds. All the 28 Arabic consonants in the form of consonant-vowel /a/ were presented randomly twice via a loudspeaker at approximately 65 dB SPL. The participants were asked to repeat verbally the stimulus heard in each presentation.
RESULTS: Within the native Malay perceptual space, the two groups responded differently to the Arabic consonants. The dispersed uncategorized assimilation in the CI group was distinct in the confusion matrix (CM), as compared to the NH children. Consonants /ħ/, /tˁ/, /sˁ/ and /ʁ/ were difficult for the CI children, while the most accurate item was /k/ (84%). The CI group transmitted significantly reduced information, especially for place feature transmission, then the NH group (p
METHODS: Speech-and-noise signals were presented to, and recorded from, six hearing aids mounted on a head and torso simulator. Test stimuli were nonsense words mixed with pink, cafeteria, or speech-modulated noise at 0 dB SNR. Fricatives /s, z/ were extracted from the recordings for analysis.
RESULTS: Analysis of the noise confirmed that MBNR in all hearing aids was activated for the recordings. More than 1.0 dB of acoustic change occurred to /s, z/ when MBNR was turned on in four out of the six hearing aids in the pink and cafeteria noise conditions. The acoustics of /s, z/ by female talkers were affected more than male talkers. Significant relationships between amount of noise reduction and acoustic change of /s, z/ were found. Amount of noise reduction accounts for 42.8% and 16.8% of the variability in acoustic change for /s/ and /z/ respectively.
CONCLUSION: Some clinically-available implementations of MBNR have measurable effects on the acoustics of fricatives. Possible implications for speech perception are discussed.
METHODS: Isotropic multiband functional MRI (1.5 mm) with sparse sampling (effective TR = 9000 ms, acquisition duration = 1962 ms) and continuous sampling (TR = 2000 ms) with ANC were compared in 15 normally hearing participants. A sustained broadband noise stimulus was presented to drive activation of both sustained and transient auditory responses within subcortical and cortical auditory regions.
RESULTS: Robust broadband noise-related activity was detected throughout the auditory pathways. Continuous sampling with ANC was found to give a statistically significant advantage over sparse sampling for the detection of the transient (onset) stimulus responses, particularly in the auditory cortex (P < .001) and inferior colliculus (P < .001), whereas gains provided by sparse over continuous ANC for detecting offset and sustained responses were marginal (p ~ 0.05 in superior olivary complex, inferior colliculus, medial geniculate body, and auditory cortex).
CONCLUSIONS: Sparse and continuous ANC multiband functional MRI protocols provide differing advantages for observing the transient (onset and offset) and sustained stimulus responses.
DESIGN: Quasi-experimental and repeated measure study designs were applied in this study. Two different stopping criteria were used, (1) a fixed-signal averaging 4000 sweeps and, (2) a minimum quality indicator of Fmp = 3.1 with a minimum of 800 sweeps.
STUDY SAMPLE: Twenty-nine normally hearing adults (18 females, 11 male) participated.
RESULTS: Wave V amplitudes were significantly larger in the LS CE-Chirp® recorded from the vertical montage than the ipsilateral montage. Waves I and III amplitudes were significantly larger from the ipsilateral LS CE-Chirp® than from the other montages and stimulus combinations. The differences in the quality of the ABR recording between the vertical and ipsilateral montages were marginal.
CONCLUSIONS: Overall, the result suggested that the vertical LS CE-Chirp® ABR had a high potential for a threshold-seeking application, because it produced a higher wave V amplitude. The Ipsilateral LS CE-Chirp® ABR, on the other hand, might also have a high potential for the site of lesion application, because it produced larger waves I and III amplitudes.
Method: Quasi-experimental and repeated-measures study designs were used in this study. Twenty-six adults with normal hearing (17 females, 9 males) participated. ABRs were acquired from the study participants at 3 intensity levels (80, 60, and 40 dB nHL), 3 frequencies (500, 1000, and 2000 Hz), 2 electrode montages (ipsilateral and vertical), and 2 stimuli (NB LS CE-Chirp and tone-burst) using 2 stopping criteria (fixed averages at 4,000 sweeps and F test at multiple points = 3.1).
Results: Wave V amplitudes were only 19%-26% larger for the vertical recordings than the ipsilateral recordings in both the ABRs obtained from the NB LS CE-Chirp and tone-burst stimuli. The mean differences in the F test at multiple points values and the residual noise levels between the ABRs obtained from the vertical and ipsilateral montages were statistically not significant. In addition, the ABR elicited from the NB LS CE-Chirp was significantly larger (up to 69%) than those from the tone-burst, except at the lower intensity level.
Conclusion: Both the ipsilateral and vertical montages can be used to record ABR to the NB LS CE-Chirp because of the small enhancement in the wave V amplitude provided by the vertical montage.
MATERIALS AND METHODS: The EEG signal was used as a brain response signal, which was evoked by two auditory stimuli (Tones and Consonant Vowels stimulus). The study was carried out on Malaysians (Malay and Chinese) with normal hearing and with hearing loss. A ranking process for the subjects' EEG data and the nonlinear features was used to obtain the maximum classification accuracy.
RESULTS: The study formulated the classification of Normal Hearing Ethnicity Index and Sensorineural Hearing Loss Ethnicity Index. These indices classified the human ethnicity according to brain auditory responses by using numerical values of response signal features. Three classification algorithms were used to verify the human ethnicity. Support Vector Machine (SVM) classified the human ethnicity with an accuracy of 90% in the cases of normal hearing and sensorineural hearing loss (SNHL); the SVM classified with an accuracy of 84%.
CONCLUSION: The classification indices categorized or separated the human ethnicity in both hearing cases of normal hearing and SNHL with high accuracy. The SVM classifier provided a good accuracy in the classification of the auditory brain responses. The proposed indices might constitute valuable tools for the classification of the brain responses according to the human ethnicity.