Displaying publications 1 - 20 of 58 in total

Abstract:
Sort:
  1. Ong T, Vindlacheruvu M
    Age Ageing, 2023 Jun 01;52(6).
    PMID: 37389557 DOI: 10.1093/ageing/afad110
    The National Institute for Health and Care Excellence released its second update on hip fracture management in early 2023. First published in 2011, the last update was in 2017. The scope of this recent update focussed on surgical implants for hip fracture. This included recommendation to offer total hip replacements instead of hemiarthroplasty for displaced intracapsular hip fractures, and a move away from Orthopaedic Device Evaluation Panel rated implants to a more standardised consistent choice. Other recommendations such as the importance of multidisciplinary orthogeriatric care, early surgery and prompt mobilisation remain. As the literature surrounding hip fracture management continue to grow, guidance such as this needs to continue updating itself to ensure patients with hip fracture receive the best possible care.
    Matched MeSH terms: Arthroplasty, Replacement, Hip*
  2. Chiu CL, Ong GS
    Ann Acad Med Singap, 2000 Mar;29(2):256-8.
    PMID: 10895351
    INTRODUCTION: We report a case of subcutaneous emphysema and pneumomediastinum that presented postoperatively after tracheal extubation.

    CLINICAL PICTURE: A 51-year-old man had an uneventful anaesthesia lasting about 6.5 hours. Intubation was performed by a very junior medical officer and was considered difficult. He developed sore throat, chest pain, numbness of both hands and palpable crepitus around the neck postoperatively. Chest X-ray revealed diffuse subcutaneous emphysema, pneumomediastinum and possible pneumopericardium.

    TREATMENT: He was treated conservatively with bed rest, oxygen, analgesia, antibiotic prophylaxis, reassurance and close monitoring.

    OUTCOME: The patient made an uneventful recovery.

    CONCLUSIONS: We discussed the possible causes.

    Matched MeSH terms: Arthroplasty, Replacement, Hip/adverse effects
  3. Baharuddin MY, Salleh ShH, Suhasril AA, Zulkifly AH, Lee MH, Omar MA, et al.
    Artif Organs, 2014 Jul;38(7):603-8.
    PMID: 24404766 DOI: 10.1111/aor.12222
    Total hip arthroplasty is a flourishing orthopedic surgery, generating billions of dollars of revenue. The cost associated with the fabrication of implants has been increasing year by year, and this phenomenon has burdened the patient with extra charges. Consequently, this study will focus on designing an accurate implant via implementing the reverse engineering of three-dimensional morphological study based on a particular population. By using finite element analysis, this study will assist to predict the outcome and could become a useful tool for preclinical testing of newly designed implants. A prototype is then fabricated using 316L stainless steel by applying investment casting techniques that reduce manufacturing cost without jeopardizing implant quality. The finite element analysis showed that the maximum von Mises stress was 66.88 MPa proximally with a safety factor of 2.39 against endosteal fracture, and micromotion was 4.73 μm, which promotes osseointegration. This method offers a fabrication process of cementless femoral stems with lower cost, subsequently helping patients, particularly those from nondeveloped countries.
    Matched MeSH terms: Arthroplasty, Replacement, Hip/economics
  4. Baharuddin MY, Salleh ShH, Zulkifly AH, Lee MH, Noor AM, A Harris AR, et al.
    PMID: 24484753 DOI: 10.1186/1471-2474-15-30
    Minimal available information concerning hip morphology is the motivation for several researchers to study the difference between Asian and Western populations. Current use of a universal hip stem of variable size is not the best option for all femur types. This present study proposed a new design process of the cementless femoral stem using a three dimensional model which provided more information and accurate analysis compared to conventional methods.
    Matched MeSH terms: Arthroplasty, Replacement, Hip/instrumentation*
  5. Kamaruzaman H, Kinghorn P, Oppong R
    BMC Musculoskelet Disord, 2017 05 10;18(1):183.
    PMID: 28486957 DOI: 10.1186/s12891-017-1540-2
    BACKGROUND: The primary purpose of this study is to assess the existing evidence on the cost-effectiveness of surgical interventions for the management of knee and hip osteoarthritis by systematically reviewing published economic evaluation studies.

    METHODS: A systematic review was conducted for the period 2004 to 2016. Electronic databases were searched to identify both trial and model based economic evaluation studies that evaluated surgical interventions for knee and hip osteoarthritis.

    RESULTS: A total of 23 studies met the inclusion criteria and an assessment of these studies showed that total knee arthroplasty (TKA), and total hip arthroplasty (THA) showed evidence of cost-effectiveness and improvement in quality of life of the patients when compared to non-operative and non-surgical procedures. On the other hand, even though delaying TKA and THA may lead to some cost savings in the short-run, the results from the study showed that this was not a cost-effective option.

    CONCLUSIONS: TKA and THA are cost-effective and should be recommended for the management of patients with end stage/severe knee and hip OA. However, there needs to be additional studies to assess the cost-effectiveness of other surgical interventions in order for definite conclusions to be reached.
    Matched MeSH terms: Arthroplasty, Replacement, Hip/economics*
  6. Baharuddin MY, Salleh ShH, Zulkifly AH, Lee MH, Mohd Noor A
    Biomed Res Int, 2014;2014:692328.
    PMID: 25025068 DOI: 10.1155/2014/692328
    A morphology study was essential to the development of the cementless femoral stem because accurate dimensions for both the periosteal and endosteal canal ensure primary fixation stability for the stem, bone interface, and prevent stress shielding at the calcar region. This paper focused on a three-dimensional femoral model for Asian patients that applied preoperative planning and femoral stem design. We measured various femoral parameters such as the femoral head offset, collodiaphyseal angle, bowing angle, anteversion, and medullary canal diameters from the osteotomy level to 150 mm below the osteotomy level to determine the position of the isthmus. Other indices and ratios for the endosteal canal, metaphyseal, and flares were computed and examined. The results showed that Asian femurs are smaller than Western femurs, except in the metaphyseal region. The canal flare index (CFI) was poorly correlated (r < 0.50) to the metaphyseal canal flare index (MCFI), but correlated well (r = 0.66) with the corticomedullary index (CMI). The diversity of the femoral size, particularly in the metaphyseal region, allows for proper femoral stem design for Asian patients, improves osseointegration, and prolongs the life of the implant.
    Matched MeSH terms: Arthroplasty, Replacement, Hip*
  7. Hafizh M, Soliman MM, Qiblawey Y, Chowdhury MEH, Islam MT, Musharavati F, et al.
    Biosensors (Basel), 2023 Jan 02;13(1).
    PMID: 36671914 DOI: 10.3390/bios13010079
    In this paper, a surface acoustic wave (SAW) sensor for hip implant geometry was proposed for the application of total hip replacement. A two-port SAW device was numerically investigated for implementation with an operating frequency of 872 MHz that can be used in more common radio frequency interrogator units. A finite element analysis of the device was developed for a lithium niobate (LiNBO3) substrate with a Rayleigh velocity of 3488 m/s on COMSOL Multiphysics. The Multiphysics loading and frequency results highlighted a good uniformity with numerical results. Afterwards, a hip implant geometry was developed. The SAW sensor was mounted at two locations on the implant corresponding to two regions along the shaft of the femur bone. Three discrete conditions were studied for the feasibility of the implant with upper- and lower-body loading. The loading simulations highlighted that the stresses experienced do not exceed the yield strengths. The voltage output results indicated that the SAW sensor can be implanted in the hip implant for hip implant-loosening detection applications.
    Matched MeSH terms: Arthroplasty, Replacement, Hip*
  8. Solehuddin Shuib, Sahari, B.B., Wong, Shaw Voon, Arumugam, Manohar, Halim Kadarman, A.
    MyJurnal
    Bone is a living tissue. It continuously reproduces its structure and its growth depends partly upon the applied mechanical load. After an implant is inserted, the load equilibrium is disturbed, leading to bone resorption and the stress shielding phenomena. Aseptic loosening is the main contributor for hip prosthesis failure. The purpose of the study is to determine the effect of bone resorption on the stress values and hence obtain a better understanding of the behavior of the stress adaptive bone-remodeling. The bone material used for the analysis was assumed to be isotropic and linearly elastic, and the external loads applied comprised of a femoral head load and an abductor load. A Finite element computer program for evaluating the changes in bone's density and modulus was developed. The values of stress for bone, cement mantle in medial, and lateral positions of Total Hip Replacement (THR) are presented. The failure mechanisms of THR with bone resorption observed the implant loosening since stress is reduced.
    Matched MeSH terms: Arthroplasty, Replacement, Hip
  9. Makker K, Lamba AK, Faraz F, Tandon S, Sheikh Ab Hamid S, Aggarwal K, et al.
    Cell Tissue Bank, 2019 Jun;20(2):243-253.
    PMID: 30903410 DOI: 10.1007/s10561-019-09763-w
    During bone allograft processing, despite stringent donor screening and use of aseptic techniques, microbial invasion may occur due to the porous nature of the graft and cause potentially fatal infections. The aim of the present study was to prepare bone allograft with and without gentamicin and to compare bioburden and sterility in the obtained grafts to evaluate the role of antibiotic in enhancing graft safety. Fifty samples of demineralized freeze-dried bone allograft were prepared from suitable donors according to international standards. Randomly selected 25 samples were placed in 8 mg gentamicin/gram bone solution for 1 h. Packaging and sealing was done to ensure no microbial ingress during transportation. 40 samples were selected for bioburden testing. Remaining 10 were subjected to 25 kGy gamma radiation and tested for sterility. Microbiological evaluation revealed no evidence of colony forming units in all the samples of both the groups (Bioburden = 0). Post-radiation sterility testing also revealed no bacterial colony in the tested samples from both the groups. Favorable results validate the processing protocol while comparable results in both groups indicate no additive benefit of gentamicin addition. Nil bioburden may be used in further studies to determine a lower radiation dose to achieve adequate sterility and minimize the disadvantages of radiation like collagen cross-linking and decreased osteoinductive capacity.
    Matched MeSH terms: Arthroplasty, Replacement, Hip
  10. Dwan LN, Gibbons P, Jamil K, Little D, Birke O, Menezes MP, et al.
    Hip Int, 2023 Mar;33(2):323-331.
    PMID: 34180253 DOI: 10.1177/11207000211027591
    BACKGROUND: Hip dysplasia is a lack of femoral head coverage and disruption of hip and acetabular alignment and congruency, with severity ranging from mild subluxation in nascent at-risk hips to complete dislocation. Presentation of hip dysplasia in neuromuscular conditions can be sub-clinical or associated with a limp with or without hip pain, abductor and flexor weakness and reduced hip range of motion. Untreated hip dysplasia leads to early onset osteoarthritis requiring hip arthroplasty in early adulthood. Hip dysplasia occurs in 6-20% of children with Charcot-Marie-Tooth disease, however little is known about the reliability and sensitivity of detection on plain film pelvic radiographs.

    METHODS: 14 common measures of hip dysplasia on anteroposterior pelvis radiographs were independently assessed by 2 orthopaedic specialists in 30 ambulant children with Charcot-Marie-Tooth disease. Hip health was also categorised based on clinical impression to assess the sensitivity of radiographic measures to identify hip dysplasia status.

    RESULTS: 8 measures (acetabular index, head width, lateral centre-edge angle, lateral uncoverage, medial joint width, migration percentage, neck shaft angle, triradiate status) exhibited 'excellent' reliability between clinical evaluators. 5 of the 30 patients (17%) were identified as having nascent hip dysplasia. Reliable radiographic measures that significantly distinguished between nascent hip dysplasia and healthy hips were acetabular index, lateral centre edge angle, medial joint width and migration percentage.

    CONCLUSIONS: We have identified a subset of reliable and sensitive radiographic hip measures in children with Charcot-Marie-Tooth disease to prioritise during hip screening to mitigate the deleterious effects of hip dysplasia, pain and disability in adulthood.

    Matched MeSH terms: Arthroplasty, Replacement, Hip*
  11. Park KS, Chan CK, Lee DH, Yoon TR
    Indian J Orthop, 2018 8 7;52(4):369-373.
    PMID: 30078894 DOI: 10.4103/ortho.IJOrtho_494_16
    Background: Conversion from failed bipolar hemiarthroplasty (HA) to total hip arthroplasty (THA) presents a great challenge to orthopedic surgeons for bipolar head removal and cup placement with or without change of femoral stem. Conversion THA after failed bipolar arthroplasty is known to offer both symptomatic and functional improvement. This study evaluates the midterm functional outcome and complications, especially dislocation associated with femoral head diameter, after conversion THA.

    Materials and Methods: Forty eight hips with the conversion of bipolar HA to THA were followed up for an average 6.2 years (range 2.0-11.5 years). Twenty one hips had conversion surgery to THA using metal-on-metal articulation (28 or 32 mm head). Nine hips used ceramic-on-ceramic (28-40 mm) and eighteen hips used large head metal-on-metal bearing (>40 mm). Outcome was evaluated using Harris Hip Score (HHS) and Western Ontario McMaster Universities Osteoarthritis Index (WOMAC) score. The radiographs were analyzed for evidence of osteolysis and/or loosening. The complications were evaluated, especially dislocation with different femoral head diameter.

    Results: Average HHS significantly improved from 42 preoperatively to 86 postoperatively and the average WOMAC score also significantly improved from 47 to 22 postoperatively. Radiological evaluation showed all the femoral components were stable. There was one acetabular component loosening, which required revision 9 years after conversion to THA. One dislocation and one recurrent dislocation were recorded in isolated acetabular revision hip; whereas one dislocation, one recurrent dislocation, and one trochanteric nonunion occurred in the hips with revision of both components. All dislocations occurred in hips with a femoral head size of 28 mm (P = 0.052). The cup and femoral head interval length was the most significant factor contributing to dislocation (P = 0.013).

    Conclusions: Conversion THA after failed bipolar HA offers a reliable pain relief and functional improvement. To prevent dislocation, it is highly recommended to use a larger diameter femoral head, especially where the cup size is big.

    Matched MeSH terms: Arthroplasty, Replacement, Hip
  12. Rosenthal VD, Richtmann R, Singh S, Apisarnthanarak A, Kübler A, Viet-Hung N, et al.
    Infect Control Hosp Epidemiol, 2013 Jun;34(6):597-604.
    PMID: 23651890 DOI: 10.1086/670626
     To report the results of a surveillance study on surgical site infections (SSIs) conducted by the International Nosocomial Infection Control Consortium (INICC).
    Matched MeSH terms: Arthroplasty, Replacement, Hip/adverse effects
  13. Lim, Chia Hua, Jacob, V.A., Premchandran, N.
    MyJurnal
    The present concepts in Total Hip Arthroplasty advocate mechanical cement interlock
    with trabecular bone utilising the third-generation cementing technique. However, the
    force generated can easily reach peak pressure of 122 kPa to 1500 kPa, leading to
    extrusion of cement through nutrient foramina into femoral cortex into nutrient vessels,
    henceforth the retrograde arteriovenogram. (Copied from article).
    Matched MeSH terms: Arthroplasty, Replacement, Hip
  14. Chan CK, Lee DH, Yoon TR, Park KS
    J Orthop Sci, 2019 09;24(5):936-938.
    PMID: 28390755 DOI: 10.1016/j.jos.2017.03.010
    Matched MeSH terms: Arthroplasty, Replacement, Hip/instrumentation*
  15. Park KS, Chan CK, Kim SK, Li QS, Im CJ, Yoon TR
    J Orthop Sci, 2019 May;24(3):452-457.
    PMID: 30415823 DOI: 10.1016/j.jos.2018.10.016
    BACKGROUND: Due to concern of potential metallosis caused by residual microscopic ceramic particles, metal-on-metal (MoM) bearing is deemed undesirable in revision total hip arthroplasty (THA) for ceramic bearing fracture. We determined whether MoM bearing is suitable to be used in revision THA for ceramic fractures and also evaluated whether this treatment increases serum iron levels compared with MoM bearing revision THA for polyethylene failure.

    METHODS: Between 2006 and 2012, 22 patients underwent revision surgery using MoM bearing (28 mm femoral head in 18 hips and 32 mm in 4 hips) for ceramic bearing fracture and followed average 52.1 months. We assessed radiological parameter and functional outcome using Harris hip score (HHS) and WOMAC score. Also, serum cobalt (Co) and chromium (Cr) blood tests were performed and compared with the result obtained from age, sex- and follow-up duration-matched patients with MoM revision THA for failed polyethylene bearing.

    RESULTS: The mean HHS improved from 60.6 preoperatively to 90.3 at final follow-up. There were no changes in cup position, progression of osteolytic lesions, and measurable wear of MoM bearing articulation at final follow-up radiographs. There was one case of recurrent dislocation after surgery, which was treated with greater trochanter distal advancement and one case of deep infection, which underwent two-stage revision. Mean serum Co level (1.7 vs. 1.4 μg/dl; p = 0.211) and Cr level (0.70 vs. 1.01 μg/dl; p = 0.327) showed no significant difference.

    CONCLUSIONS: MoM articulation with liner cementation into the acetabular cup along with total synovectomy can be chosen in revision surgery for ceramic fracture with good midterm follow-up. However, the use of MoM bearing is indicated when the stem and metal shell can be retained and ceramic on ceramic or ceramic on polyethylene bearing cannot be selected. Also long-term outcome needs to be further evaluated.

    Matched MeSH terms: Arthroplasty, Replacement, Hip/adverse effects; Arthroplasty, Replacement, Hip/instrumentation*
  16. Wazir NN, Mukundala VV, Choon DS
    J Orthop Surg (Hong Kong), 2006 Apr;14(1):43-6.
    PMID: 16598086 DOI: 10.1177/230949900601400110
    PURPOSE: To evaluate the short-term clinical and functional outcomes of total hip arthroplasty performed for physiologically active elderly patients with Garden type-3 or -4 femoral neck fracture.
    METHODS: Records of 47 consecutive patients (40 female, 7 male) with type-3 or -4 femoral neck fracture (Garden classification) who underwent cemented total hip arthroplasty at our hospital during January 1999 to December 2002 were reviewed. Radiological and clinical (Harris functional hip score and Oxford hip score) assessments of 38 patients were measured with a mean follow-up period of 21 months (range, 4-48 months).
    RESULTS: The mean age of the 47 patients was 75 years (range, 62-89 years). Records of 9 patients were excluded because of death, lost to follow-up, and development of deep infection that necessitated implant removal and excision arthroplasty. The mean Harris hip score of the 38 patients was 83 (range, 59-97), whereas the mean Oxford hip score was 25.2 (range, 14-33). Pain in the hips was absent in 30 patients, 6 had slight pain occasionally, and 2 patients had mild-to-moderate hip discomfort. No signs of aseptic loosening or change in implant position were noted on radiographic assessment. Two cases of dislocation were reduced by closed reduction. Two patients had deep wound infection and were treated with debridement, implant removal, and conversion to girdle stone.
    CONCLUSION: This short-term study showed that total hip arthroplasty for femoral neck fracture had good postoperative results in functional hip and pain scores. More attention should be paid to coexisting medical illness (e.g. diabetes mellitus, hypertension, and ischaemic heart disease) and prevention of infection.
    Matched MeSH terms: Arthroplasty, Replacement, Hip*
  17. Arif M, Sivananthan S, Choon DS
    J Orthop Surg (Hong Kong), 2004 Jun;12(1):25-30.
    PMID: 15237118
    To report the outcome of revised total hip arthroplasty procedures involving an anterior cortical window, extensive strut allografts, and an Exeter impaction graft.
    Matched MeSH terms: Arthroplasty, Replacement, Hip/adverse effects*; Arthroplasty, Replacement, Hip/methods
  18. Sivananthan S, Arif M, Choon DS
    J Orthop Surg (Hong Kong), 2003 Dec;11(2):148-53.
    PMID: 14676339
    To evaluate the clinical and radiological outcome in patients undergoing small stem Exeter total hip replacement.
    Matched MeSH terms: Arthroplasty, Replacement, Hip/instrumentation*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)