Displaying publications 1 - 20 of 82 in total

Abstract:
Sort:
  1. Thomas AR, Soe HHK, Silva CS, Kaur H, Ganendrah LD, Gomez LM
    Am J Dent, 2023 Oct;36(5):246-250.
    PMID: 37865812
    PURPOSE: To compare the accuracy and reliability of cone-beam computed tomography (CBCT) and laser scanner in measuring minor volume changes such as the root canal space.

    METHODS: 35 maxillary incisors were endodontically prepared. A dimensionally stable silicone material was injected into the root canal space and scanned with CBCT. The root canal volume was measured using Romexis 3.0.1 R software. Replicas were carefully removed from the teeth and scanned using an extraoral laser scanner. These images were exported to the Rhinoceros software for volume measurement. The volume of each replica was also assessed using the gravimetric method. To determine the accuracy, the volume obtained from both devices was compared with the gravimetric method. Statistical analysis was done using a paired t-test. The reliability was assessed using the intraclass correlation coefficient.

    RESULTS: There was no statistically significant difference between the mean volume of CBCT 27.04 ± 7.25 mm³ and the mean volume of the gravimetric method 27.87 ± 7.17 mm³ (P< 0.05). A statistically significant difference was seen with the laser scanner at 25.31 ± 6.89 mm³ and the gravimetric method at 27.87 ± 7.17 mm³ (P< 0.05). CBCT showed a good degree of agreement (ICC 0.899), while the laser scanner showed a moderate degree of agreement (ICC 0.644) with the gravimetric method. CBCT proved accurate and reliable in measuring minor volumes like the root canal space, ideally in the range of 20-25 mm³. The laser scanner presented acceptable reliability.

    CLINICAL SIGNIFICANCE: The laboratory data showed satisfactory outcomes, providing an evidence-based approach and potentially motivating clinicians to integrate cone-beam computed tomography for volume analysis into clinical practice. The accuracy and reliability of laser scanners for small-volume analysis have not previously been evaluated. Consequently, the findings from this study warrant further clinical investigations.

    Matched MeSH terms: Spiral Cone-Beam Computed Tomography*
  2. Asif MK, Ibrahim N, Sivarajan S, Heng Khiang Teh N, Chek Wey M
    Am J Orthod Dentofacial Orthop, 2020 Oct;158(4):579-586.e1.
    PMID: 32826123 DOI: 10.1016/j.ajodo.2019.09.022
    INTRODUCTION: The study aimed to investigate the effects of micro-osteoperforations (MOPs) on the mandibular bone volume/tissue volume (BV/TV) ratio changes and the rate of orthodontic tooth movement using cone-beam computed tomography images. Another objective was to evaluate the effects of MOP frequency intervals (4 weeks, 8 weeks, and 12 weeks) on the BV/TV ratio and rate of tooth movement.

    METHODS: In 24 participants, 140-200 g of force was applied for mandibular canine retraction. Three MOPs were made according to the scheduled intervals of the 3 different groups: group 1 (MOP 4 weeks), group 2 (MOP 8 weeks), and group 3 (MOP 12 weeks) directly at the mandibular buccal cortical bone of extracted first premolars sites. Cone-beam computed tomography scans were obtained at the 12th week after MOP application. Computed tomography Analyzer software (version 1.11.0.0; Skyscan, Kontich, Belgium) was used to compute the trabecular alveolar BV/TV ratio.

    RESULTS: A significant difference was observed in the rate of canine movement between control and MOP. Paired t test analysis showed a significant difference (P = 0.001) in the mean BV/TV ratio between control and MOP sides in all the frequency intervals groups. However, the difference was significant only in group 1 (P = 0.014). A strong negative correlation (r = -0.86) was observed between the rate of canine tooth movement and the BV/TV ratio at the MOP side for group 1 and all frequency intervals together (r = -0.42).

    CONCLUSIONS: The rate of orthodontic tooth movement can be accelerated by the MOP technique with frequently repeated MOPs throughout the treatment.

    Matched MeSH terms: Cone-Beam Computed Tomography
  3. Wan Hassan WN, Othman SA, Chan CS, Ahmad R, Ali SN, Abd Rohim A
    Am J Orthod Dentofacial Orthop, 2016 Nov;150(5):886-895.
    PMID: 27871715 DOI: 10.1016/j.ajodo.2016.04.021
    INTRODUCTION: In this study we aimed to compare measurements on plaster models using a digital caliper, and on 3-dimensional (3D) digital models, produced using a structured-light scanner, using 3D software.

    METHODS: Fifty digital models were scanned from the same plaster models. Arch and tooth size measurements were made by 2 operators, twice. Calibration was done on 10 sets of models and checked using the Pearson correlation coefficient. Data were analyzed by error variances, repeatability coefficient, repeated-measures analysis of variance, and Bland-Altman plots.

    RESULTS: Error variances ranged between 0.001 and 0.044 mm for the digital caliper method, and between 0.002 and 0.054 mm for the 3D software method. Repeated-measures analysis of variance showed small but statistically significant differences (P <0.05) between the repeated measurements in the arch and buccolingual planes (0.011 and 0.008 mm, respectively). There were no statistically significant differences between methods and between operators. Bland-Altman plots showed that the mean biases were close to zero, and the 95% limits of agreement were within ±0.50 mm. Repeatability coefficients for all measurements were similar.

    CONCLUSIONS: Measurements made on models scanned by the 3D structured-light scanner were in good agreement with those made on conventional plaster models and were, therefore, clinically acceptable.

    Matched MeSH terms: Cone-Beam Computed Tomography
  4. Alkhorayef M, Sulieman A, Alzahrani K, Abuzaid M, Alomair OI, Almuwannis M, et al.
    Appl Radiat Isot, 2021 Feb;168:109520.
    PMID: 33307438 DOI: 10.1016/j.apradiso.2020.109520
    The various technological advancements in computed tomography (CT) have resulted in remarkable growth in the use of CT imaging in clinical practice, not the least of which has been its establishment as the most valuable imaging examination for the assessment of cardiovascular system disorders. The objective of this study was to assess the effective radiation dose and radiation risk for patients during cardiac CT procedures, based on studies from four different hospitals equipped with 128 slice CT equipment. A total of eighty-three patients were investigated in this study with different clinical indications. Effective doses were also calculated using software based on Monte Carlo simulation. The mean patient age (years), weight (kg), and body mass index (BMI (kg/m2)) were 49 ± 11, 82 ± 12, and 31 ± 6, respectively. The results of the study revealed that the tube voltage (kVp) and tube current-exposure time product (mAs) ranged between 100 to 140 and 50 to 840 respectively. The overall average patient dose values for the volume CT dose index [(CTDIvol), in mGy)] and dose length product (DLP) (in mGy·cm) were 34.8 ± 15 (3.7-117.0) and 383.8 ± 354 (46.0-3277.0) respectively. The average effective dose (mSv) was 15.2 ± 8 (1.2-61.8). The radiation dose values showed wide variation between different hospitals and even within the same hospital. The results indicate the need to optimize radiation dose and to establish diagnostic reference levels (DRLs) for patients undergoing coronary computed tomography angiography (CCTA), also to harmonize the imaging protocols to ensure reduced radiation risk.
    Matched MeSH terms: Cone-Beam Computed Tomography
  5. Anderson PJ, Yong R, Surman TL, Rajion ZA, Ranjitkar S
    Aust Dent J, 2014 Jun;59 Suppl 1:174-85.
    PMID: 24611727 DOI: 10.1111/adj.12154
    Following the invention of the first computed tomography (CT) scanner in the early 1970s, many innovations in three-dimensional (3D) diagnostic imaging technology have occurred, leading to a wide range of applications in craniofacial clinical practice and research. Three-dimensional image analysis provides superior and more detailed information compared with conventional plain two-dimensional (2D) radiography, with the added benefit of 3D printing for preoperative treatment planning and regenerative therapy. Current state-of-the-art multidetector CT (MDCT), also known as medical CT, has an important role in the diagnosis and management of craniofacial injuries and pathology. Three-dimensional cone beam CT (CBCT), pioneered in the 1990s, is gaining increasing popularity in dental and craniofacial clinical practice because of its faster image acquisition at a lower radiation dose, but sound guidelines are needed to ensure its optimal clinical use. Recent innovations in micro-computed tomography (micro-CT) have revolutionized craniofacial biology research by enabling higher resolution scanning of teeth beyond the capabilities of MDCT and CBCT, presenting new prospects for translational clinical research. Even after four decades of refinement, CT technology continues to advance and broaden the horizons of craniofacial clinical practice and phenomics research.
    Matched MeSH terms: Cone-Beam Computed Tomography
  6. Yusof M, Dasor MM, Ariffin F, Reduwan NH, Kamil W, Mah MC
    Aust Dent J, 2020 Dec;65(4):308-312.
    PMID: 32259287 DOI: 10.1111/adj.12756
    This report presents two cases of idiopathic osteosclerosis involving the maxilla and mandible which were identified as a buccally impacted canine and a retained root, respectively, on clinical and plain radiographical examinations. Both patients were females who presented with hypodontia. Radiographic evaluation revealed solitary well-defined radiopaque masses with thickened cortical border. Both patients were undergoing orthodontic treatment and one was planned for a surgical traction of unerupted tooth prior to cone-beam CT assessment. In this report, we reviewed the clinical findings and explained the radiographic appearance of idiopathic osteosclerosis through plain radiographs and cone-beam CT to facilitate its identification among general dentists and oral and maxillofacial radiologists.
    Matched MeSH terms: Cone-Beam Computed Tomography
  7. Karobari MI, Noorani TY, Halim MS, Ahmed HMA
    Aust Endod J, 2021 Aug;47(2):202-216.
    PMID: 33159714 DOI: 10.1111/aej.12454
    This cone beam computed tomography (CBCT) study aimed to evaluate the root canal morphology of permanent anteriors in Malaysian population using two classification systems (Vertucci 1984 and Ahmed et al 2017). CBCT images of 856 patients with 10,080 anterior teeth were analysed. Results showed that, except for six mandibular canines, all anterior teeth were single-rooted. According to Ahmed et al's system and Vertucci's classification, code 1 MaxA1 and type I were the most common types except in mandibular laterals where 1 ManA1-2-1 and type III were the most common, respectively. The prevalence of canal variations in mandibular incisors was higher in males and the 20-30 age group than in females and other age groups (P 
    Matched MeSH terms: Cone-Beam Computed Tomography; Spiral Cone-Beam Computed Tomography*
  8. Pan JYY, Parolia A, Chuah SR, Bhatia S, Mutalik S, Pau A
    BMC Oral Health, 2019 01 14;19(1):14.
    PMID: 30642318 DOI: 10.1186/s12903-019-0710-z
    BACKGROUND: To determine the root canal morphology of human permanent maxillary and mandibular teeth in a Malaysian subpopulation using cone-beam computed tomography (CBCT).

    METHODS: A total of 208 CBCT images were examined retrospectively. Prevalence of an extra root/canal and internal morphology based on Vertucci's classification were observed in human maxillary and mandibular permanent teeth. Variations in the external and internal morphology were compared in relation to gender and tooth side (left vs right) using Pearson Chi-square and Fisher's exact tests with significance level set at p 

    Matched MeSH terms: Cone-Beam Computed Tomography/methods*
  9. Ibrahim N, Parsa A, Hassan B, van der Stelt P, Rahmat RA, Ismail SM, et al.
    BMC Oral Health, 2021 05 08;21(1):249.
    PMID: 33964918 DOI: 10.1186/s12903-021-01595-z
    BACKGROUND: The aim of this study was to compare the trabecular bone microstructures of anterior and posterior edentulous regions of human mandible using cone-beam computed tomography (CBCT) and micro computed tomography (µCT).

    METHODS: Twenty volumes of interests consisting of six anterior and fourteen posterior edentulous regions were obtained from human mandibular cadavers. A CBCT system with a resolution of 80 µm (3D Accuitomo 170, J. Morita, Kyoto, Japan) and a µCT system with a resolution of 35 µm (SkyScan 1173, Kontich, Belgium) were used to scan the mandibles. Three structural parameters namely, trabecular number (Tb.N), trabecular thickness (Tb.Th), and trabecular separation (Tb.Sp) were analysed using CTAn software (v 1.11, SkyScan, Kontich, Belgium). For each system, the measurements obtained from anterior and posterior regions were tested using independent sample t-test. Subsequently, all measurements between systems were tested using paired t-test.

    RESULTS: In CBCT, all parameters of the anterior and posterior mandible showed no significant differences (p > 0.05). However, µCT showed a significant different of Tb.Th (p = 0.023) between anterior and posterior region. Regardless of regions, the measurements obtained using both imaging systems were significantly different (p ≤ 0.021) for Tb.Th and Tb.N.

    CONCLUSIONS: The current study demonstrated that only the variation of Tb.Th between anterior and posterior edentulous region of mandible can be detected using µCT. In addition, CBCT is less feasible than µCT in assessing trabecular bone microstructures at both regions.

    Matched MeSH terms: Cone-Beam Computed Tomography
  10. Muhammad AMA, Ibrahim N, Ahmad R, Asif MK, Radzi Z, Zaini ZM, et al.
    BMC Oral Health, 2020 02 10;20(1):48.
    PMID: 32041589 DOI: 10.1186/s12903-020-1035-7
    BACKGROUND: Cone Beam Computed Tomography (CBCT) is a reliable radiographic modality to assess trabecular bone microarchitecture. The aim of this study was to determine the effect of CBCT image reconstruction parameters, namely, the threshold value and reconstruction voxel size, on trabecular bone microstructure assessment.

    METHODS: Five sectioned maxilla of adult Dorper male sheep were scanned using a CBCT system with a resolution of 76 μm3 (Kodak 9000). The CBCT images were reconstructed using different reconstruction parameters and analysed. The effect of reconstruction voxel size (76, 100 and 200 μm3) and threshold values (±15% from the global threshold value) on trabecular bone microstructure measurement was assessed using image analysis software (CT analyser version 1.15).

    RESULTS: There was no significant difference in trabecular bone microstructure measurement between the reconstruction voxel sizes, but a significant difference (Tb.N = 0.03, Tb.Sp = 0.04, Tb.Th = 0.01, BV/TV = 0.00) was apparent when the global threshold value was decreased by 15%.

    CONCLUSIONS: Trabecular bone microstructure measurements are not compromised by changing the CBCT reconstruction voxel size. However, measurements can be affected when applying a threshold value of less than 15% of the recommended global value.

    Matched MeSH terms: Cone-Beam Computed Tomography/methods*
  11. Reduwan NH, Abdul Aziz AA, Mohd Razi R, Abdullah ERMF, Mazloom Nezhad SM, Gohain M, et al.
    BMC Oral Health, 2024 Feb 19;24(1):252.
    PMID: 38373931 DOI: 10.1186/s12903-024-03910-w
    BACKGROUND: Artificial intelligence has been proven to improve the identification of various maxillofacial lesions. The aim of the current study is two-fold: to assess the performance of four deep learning models (DLM) in external root resorption (ERR) identification and to assess the effect of combining feature selection technique (FST) with DLM on their ability in ERR identification.

    METHODS: External root resorption was simulated on 88 extracted premolar teeth using tungsten bur in different depths (0.5 mm, 1 mm, and 2 mm). All teeth were scanned using a Cone beam CT (Carestream Dental, Atlanta, GA). Afterward, a training (70%), validation (10%), and test (20%) dataset were established. The performance of four DLMs including Random Forest (RF) + Visual Geometry Group 16 (VGG), RF + EfficienNetB4 (EFNET), Support Vector Machine (SVM) + VGG, and SVM + EFNET) and four hybrid models (DLM + FST: (i) FS + RF + VGG, (ii) FS + RF + EFNET, (iii) FS + SVM + VGG and (iv) FS + SVM + EFNET) was compared. Five performance parameters were assessed: classification accuracy, F1-score, precision, specificity, and error rate. FST algorithms (Boruta and Recursive Feature Selection) were combined with the DLMs to assess their performance.

    RESULTS: RF + VGG exhibited the highest performance in identifying ERR, followed by the other tested models. Similarly, FST combined with RF + VGG outperformed other models with classification accuracy, F1-score, precision, and specificity of 81.9%, weighted accuracy of 83%, and area under the curve (AUC) of 96%. Kruskal Wallis test revealed a significant difference (p = 0.008) in the prediction accuracy among the eight DLMs.

    CONCLUSION: In general, all DLMs have similar performance on ERR identification. However, the performance can be improved by combining FST with DLMs.

    Matched MeSH terms: Cone-Beam Computed Tomography; Spiral Cone-Beam Computed Tomography*
  12. Rajaran JR, Nazimi AJ, Rajandram RK
    BMJ Case Rep, 2017 Sep 27;2017.
    PMID: 28954756 DOI: 10.1136/bcr-2017-221892
    Surgical removal of impacted mandibular third molar is a routine procedure in oral surgery. Various iatrogenic complications related to the procedure has been discussed well in the literatures before. Some of these complications are related to the wrong usage of instruments and techniques. Here we discuss a rare complication on a 42-year-old male, related to the use of high-speed handpiece drill in mandibular third molar removal in a general dental office setting. He was referred when a high speed tungsten carbide bur was accidentally broken and displaced into the mandibular bone during surgical procedure. It is not common to use a high-speed handpiece in impacted third molar removal. This iatrogenic complication could have been totally avoided with the use of proper equipment and technique; therefore raising awareness regarding wrong usage of instrument is vital to avoid similar incidents in the future.
    Matched MeSH terms: Cone-Beam Computed Tomography
  13. Donald PM, Nayak V
    BMJ Case Rep, 2022 Apr 07;15(4).
    PMID: 35393280 DOI: 10.1136/bcr-2022-249127
    Matched MeSH terms: Cone-Beam Computed Tomography*
  14. Ng Kh, Wong J
    Biomed Imaging Interv J, 2008 Apr;4(2):e21.
    PMID: 21614324 DOI: 10.2349/biij.4.2.21
    Informal discussion started in 1996 and the South East Asian Federation of Organizations for Medical Physics (SEAFOMP) was officially accepted as a regional chapter of the IOMP at the Chicago World Congress in 2000 with five member countries, namely Indonesia, Malaysia, Philippines, Singapore and Thailand. Professor Kwan-Hoong Ng served as the founding president until 2006. Brunei (2002) and Vietnam (2005) joined subsequently. We are very grateful to the founding members of SEAFOMP: Anchali Krisanachinda, Kwan-Hoong Ng, Agnette Peralta, Ratana Pirabul, Djarwani S Soejoko and Toh-Jui Wong.The objectives of SEAFOMP are to promote (i) co-operation and communication between medical physics organizations in the region; (ii) medical physics and related activities in the region; (iii) the advancement in status and standard of practice of the medical physics profession; (iv) to organize and/or sponsor international and regional conferences, meetings or courses; (v) to collaborate or affiliate with other scientific organizations.SEAFOMP has been organizing a series of congresses to promote scientific exchange and mutual support. The South East Asian Congress of Medical Physics (SEACOMP) series was held respectively in Kuala Lumpur (2001), Bangkok (2003), Kuala Lumpur (2004) and Jakarta (2006). The respective congress themes indicated the emphasis and status of development. The number of participants (countries in parentheses) was encouraging: 110 (17), 150 (16), 220 (23) and 126 (7).In honour of the late Professor John Cameron, an eponymous lecture was established. The inaugural John Cameron Lecture was delivered by Professor Willi Kalender in 2004. His lecture was titled "Recent Developments in Volume CT Scanning".
    Matched MeSH terms: Cone-Beam Computed Tomography
  15. Lim EL, Ngeow WC, Lim D
    Braz Oral Res, 2017 Nov 27;31:e97.
    PMID: 29185606 DOI: 10.1590/1807-3107bor-2017.vol31.0097
    The objective of this study was to measure the topographic thickness of the lateral wall of the maxillary sinus in selected Asian populations. Measurements were made on the lateral walls of maxillary sinuses recorded using CBCT in a convenient sample of patients attending an Asian teaching hospital. The points of measurement were the intersections between the axes along the apices of the canine, first premolar, and second premolar and along the mesiobuccal and distobuccal apices of the first and second molars and horizontal planes 10 mm, 20 mm, 30 mm and 40 mm beneath the orbital floor. The CBCT images of 109 patients were reviewed. The mean age of the patients was 33.0 (SD 14.8) years. Almost three quarters (71.8%) of the patients were male. The mean bone thickness decreased beginning at the 10-mm level and continuing to 40 mm below the orbital floor. Few canine regions showed encroachment of the maxillary sinus. The thickness of the buccal wall gradually increased from the canine region (where sinus encroachment of the canine region was present) to the first molar region, after which it decreased to the thickness observed at the canine region. The buccal wall of the maxillary sinus became thicker anteroposteriorly, except in the region of the second molar, and thinner superoinferiorly. These changes will affect the approach used to osteotomize the lateral sinus wall for oral surgery and for the sinus lift procedure.
    Matched MeSH terms: Cone-Beam Computed Tomography/methods
  16. Karobari MI, Alam BF, Bashir R, Fahim MF, Mirza MB, Noorani TY
    Clin Exp Dent Res, 2023 Dec;9(6):1156-1168.
    PMID: 37877522 DOI: 10.1002/cre2.801
    OBJECTIVES: This bibliometric analysis aimed to evaluate the leading nations, authors, journals, institutes, highly cited publications, and most commonly used keywords concerning scientific publications based on root and root canal morphology using the CBCT.

    MATERIAL AND METHODS: For this bibliometric analysis, an extensive search was carried out on September 25, 2023 using the Scopus database. Pertinent articles in the field were scrutinized after applying inclusion and exclusion criteria. Data were evaluated using Vosviewer and Microsoft Excel.

    RESULTS: A literature search revealed the initiation of scientific publication in 2008. Significant contributions made by Saudi Arabia, India, and China concerning the number of publications were seen. Similarly, Jazan University from SA was recognized as the leading institute. The Journal of Endodontics was the leading journal, while authors JNR Martins and G Gambarini produced the highest number of papers.

    CONCLUSIONS: This bibliometric analysis demonstrated that scientific publications have increased tremendously since 2008. Significant contributions have been made by developing and developed nations. The Journal of Endodontics and Jazan University have been identified as the leading journal and institute.

    Matched MeSH terms: Cone-Beam Computed Tomography
  17. Mustafa A, Lung CY, Mustafa NS, Mustafa BA, Kashmoola MA, Zwahlen RA, et al.
    Clin Oral Implants Res, 2016 Mar;27(3):303-9.
    PMID: 25393376 DOI: 10.1111/clr.12525
    OBJECTIVES: To investigate the effect of eicosapentaenoic acid (EPA)-coated Ti implants on osteoconduction in white New Zealand rabbit mandibles.

    MATERIAL AND METHODS: Sandblasted and cleansed planar titanium specimens with a size of 5 × 5 × 1 mm were coated on one side with 0.25 vol% eicosapentaenoic acid (EPA). The other side of the specimens was kept highly polished (the control side). These specimens were inserted in rabbit mandibles. Twelve rabbits were randomly assigned into three study groups (n = 4). The rabbits were sacrificed at 4, 8, and 12 weeks. The harvested specimens with the implants were assessed for new bone formation on both sides of the implant using CBCT, conventional radiographs, and the biaxial pullout test. The results were statistically analyzed by a nonparametric Kruskal-Wallis test and Friedman's test as multiple comparisons and by Brunner-Langer nonparametric mixed model approach (R Software).

    RESULTS: A significant osteoconductive bone formation was found on the EPA-coated Ti implant surface (P < 0.05) at 8 weeks when compared to the polished surface (control). Biaxial pullout test results showed a significant difference (P < 0.05) after 8 and 12 weeks with a maximum force of 243.8 N, compared to 143.25 N after 4 week.

    CONCLUSION: EPA implant coating promoted osteoconduction on the Ti implant surfaces, enhancing the anchorage of the implant to the surrounding bone in white New Zealand rabbits.

    Matched MeSH terms: Cone-Beam Computed Tomography
  18. Al-Ani O, Nambiar P, Ha KO, Ngeow WC
    Clin Oral Implants Res, 2013 Aug;24 Suppl A100:115-21.
    PMID: 22233422 DOI: 10.1111/j.1600-0501.2011.02393.x
    The mandibular incisive nerve can be subjected to iatrogenic injury during bone graft harvesting. Using cone beam computed tomography (CBCT), this study aims to determine a safe zone for bone graft harvesting that avoids injuring this nerve.
    Matched MeSH terms: Cone-Beam Computed Tomography
  19. Yusof NAM, Noor E, Reduwan NH, Yusof MYPM
    Clin Oral Investig, 2021 Mar;25(3):923-932.
    PMID: 32535703 DOI: 10.1007/s00784-020-03380-8
    OBJECTIVES: The aim of this study was to evaluate the accuracy of cone beam computed tomography (CBCT), periapical radiograph, and intrasurgical linear measurements in the assessment of molars with furcation defects.

    MATERIALS AND METHODS: This parallel, single-blinded, randomised controlled trial (RCT) consisted of 22 periodontitis patients who had molar with advanced furcation involvement (FI). All patients followed the same inclusion criteria and were treated following the same protocol, except for radiographic evaluation (CBCT vs. periapical). This study proposed and evaluated five parameters that represent the extent and severity of furcation defects in molars teeth, including CEJ-BD (clinical attachment loss), BL-H (depth), BL-V (height), RT (root trunk), and FW (width).

    RESULTS: There were no statistically significant differences between CBCT and intrasurgical linear measurements for any clinical parameter (p > 0.05). However, there were statistically significant differences in BL-V measurements (p 

    Matched MeSH terms: Cone-Beam Computed Tomography; Spiral Cone-Beam Computed Tomography
  20. Al-Jaf, Nagham, Rohaya Megat Abdul Wahab, Mohamed Ibrahim Abu Hassan
    Compendium of Oral Science, 2015;2(1):14-20.
    MyJurnal
    Objectives: To assess interradicular spaces of maxilla and mandible in subjects with class I sagittal skeletal relationship as an aid for miniscrew placement. Materials and Methods: The study was carried out using cone-beam computed tomography (CBCT) images of 47 adult subjects with class I skeletal relationship. Interradicular spaces were obtained at the alveolar processes from first premolar to second molar at 2 different vertical levels (6 and 8mm) from the cementoenamel junction (C.E.J). Results: In the maxilla, the highest inter-radicular space existed between second premolar and first molar. In the mandible, the highest interradicular space existed between first and second molar. All mandibular measurements were higher than their respective maxillary measurement. Generally, availability of interradicular space increases apically in both arches, but the difference is not significant. In the maxilla, male subjects’ measurement were significantly higher at 8 mm level between second premolar and first molar and between first and second molar Conclusions: Interradicular spac-es in the maxillary and mandibular alveolar spaces are available for miniscrew placement. In both arches, a more apical location provides more interradicular space. However, careful planning is needed to avoid sinus perforation.
    Matched MeSH terms: Cone-Beam Computed Tomography; Spiral Cone-Beam Computed Tomography