Displaying publications 1 - 20 of 26 in total

Abstract:
Sort:
  1. Ahmed N, Halim MSB, Ghani ZA, Khan ZA, Abbasi MS, Jamayet NB, et al.
    Biomed Res Int, 2021;2021:6674400.
    PMID: 33969123 DOI: 10.1155/2021/6674400
    The objective of this paper was to evaluate the existence of golden percentage in natural maxillary anterior teeth with the aid of 3D digital dental models and 2D photographs. And to propose regional values of golden percentage for restoration of maxillary anterior teeth. For this purpose, one hundred and ninety dentate subjects with sound maxillary anterior teeth were selected. Standardized frontal images were captured with DSLR, and the apparent width of maxillary anterior teeth was measured utilizing a software on a personal laptop computer. Once the dimensions were recorded, the calculations were made according to the golden percentage theory (GPT). The data were analyzed by independent and paired T-test. The level of significance was set at p < 0.05. The golden percentage values were not found in this study. The values obtained were 16%, 15%, 20%, 20%, 15%, and 16% moving from the right canine to the left canine teeth. There was no significant gender difference in the golden percentage values. Thus, golden percentage should not be used solely for the correction of anterior teeth or for determining dental attractiveness. Emphasis should be given to a range of dental proportion on regional basis.
    Matched MeSH terms: Dental Models*
  2. Baig MR, Buzayan MM, Yunus N
    J Investig Clin Dent, 2018 May;9(2):e12320.
    PMID: 29349910 DOI: 10.1111/jicd.12320
    AIM: The aim of the present study was to assess the accuracy of multi-unit dental implant casts obtained from two elastomeric impression materials, vinyl polyether silicone (VPES) and polyether (PE), and to test the effect of splinting of impression copings on the accuracy of implant casts.

    METHODS: Forty direct impressions of a mandibular reference model fitted with six dental implants and multibase abutments were made using VPES and PE, and implant casts were poured (N = 20). The VPES and PE groups were split into four subgroups of five each, based on splinting type: (a) no splinting; (b) bite registration polyether; (c) bite registration addition silicone; and (d) autopolymerizing acrylic resin. The accuracy of implant-abutment replica positions was calculated on the experimental casts, in terms of interimplant distances in the x, y, and z-axes, using a coordinate measuring machine; values were compared with those measured on the reference model. Data were analyzed using non-parametrical Kruskal-Wallis and Mann-Whitney tests at α = .05.

    RESULTS: The differences between the two impression materials, VPES and PE, regardless of splinting type, were not statistically significant (P>.05). Non-splinting and splinting groups were also not significantly different for both PE and VPES (P>.05).

    CONCLUSIONS: The accuracy of VPES impression material seemed comparable with PE for multi-implant abutment-level impressions. Splinting had no effect on the accuracy of implant impressions.

    Matched MeSH terms: Dental Models*
  3. Wan Hassan WN, Othman SA, Chan CS, Ahmad R, Ali SN, Abd Rohim A
    Am J Orthod Dentofacial Orthop, 2016 Nov;150(5):886-895.
    PMID: 27871715 DOI: 10.1016/j.ajodo.2016.04.021
    INTRODUCTION: In this study we aimed to compare measurements on plaster models using a digital caliper, and on 3-dimensional (3D) digital models, produced using a structured-light scanner, using 3D software.

    METHODS: Fifty digital models were scanned from the same plaster models. Arch and tooth size measurements were made by 2 operators, twice. Calibration was done on 10 sets of models and checked using the Pearson correlation coefficient. Data were analyzed by error variances, repeatability coefficient, repeated-measures analysis of variance, and Bland-Altman plots.

    RESULTS: Error variances ranged between 0.001 and 0.044 mm for the digital caliper method, and between 0.002 and 0.054 mm for the 3D software method. Repeated-measures analysis of variance showed small but statistically significant differences (P <0.05) between the repeated measurements in the arch and buccolingual planes (0.011 and 0.008 mm, respectively). There were no statistically significant differences between methods and between operators. Bland-Altman plots showed that the mean biases were close to zero, and the 95% limits of agreement were within ±0.50 mm. Repeatability coefficients for all measurements were similar.

    CONCLUSIONS: Measurements made on models scanned by the 3D structured-light scanner were in good agreement with those made on conventional plaster models and were, therefore, clinically acceptable.

    Matched MeSH terms: Dental Models*
  4. Wan Hassan WN, Yusoff Y, Mardi NA
    Am J Orthod Dentofacial Orthop, 2017 Jan;151(1):209-218.
    PMID: 28024776 DOI: 10.1016/j.ajodo.2016.08.019
    INTRODUCTION: Rapid prototyping models can be reconstructed from stereolithographic digital study model data to produce hard-copy casts. In this study, we aimed to compare agreement and accuracy of measurements made with rapid prototyping and stone models for different degrees of crowding.

    METHODS: The Z Printer 450 (3D Systems, Rock Hill, SC) reprinted 10 sets of models for each category of crowding (mild, moderate, and severe) scanned using a structured-light scanner (Maestro 3D, AGE Solutions, Pisa, Italy). Stone and RP models were measured using digital calipers for tooth sizes in the mesiodistal, buccolingual, and crown height planes and for arch dimension measurements. Bland-Altman and paired t test analyses were used to assess agreement and accuracy. Clinical significance was set at ±0.50 mm.

    RESULTS: Bland-Altman analysis showed the mean bias of measurements between the models to be within ±0.15 mm (SD, ±0.40 mm), but the 95% limits of agreement exceeded the cutoff point of ±0.50 mm (lower range, -0.81 to -0.41 mm; upper range, 0.34 to 0.76 mm). Paired t tests showed statistically significant differences for all planes in all categories of crowding except for crown height in the moderate crowding group and arch dimensions in the mild and moderate crowding groups.

    CONCLUSIONS: The rapid prototyping models were not clinically comparable with conventional stone models regardless of the degree of crowding.

    Matched MeSH terms: Dental Models*
  5. Nawi N, Mohamed AM, Marizan Nor M, Ashar NA
    J Orofac Orthop, 2018 Jan;79(1):19-27.
    PMID: 29116344 DOI: 10.1007/s00056-017-0111-3
    OBJECTIVE: The aim of the present study was to determine the overall reliability and validity of arch parameters measured digitally compared to conventional measurement.

    METHODS: A sample of 111 plaster study models of Down syndrome (DS) patients were digitized using a blue light three-dimensional (3D) scanner. Digital and manual measurements of defined parameters were performed using Geomagic analysis software (Geomagic Studio 2014 software, 3D Systems, Rock Hill, SC, USA) on digital models and with a digital calliper (Tuten, Germany) on plaster study models. Both measurements were repeated twice to validate the intraexaminer reliability based on intraclass correlation coefficients (ICCs) using the independent t test and Pearson's correlation, respectively. The Bland-Altman method of analysis was used to evaluate the agreement of the measurement between the digital and plaster models.

    RESULTS: No statistically significant differences (p > 0.05) were found between the manual and digital methods when measuring the arch width, arch length, and space analysis. In addition, all parameters showed a significant correlation coefficient (r ≥ 0.972; p 

    Matched MeSH terms: Dental Models*
  6. Banabilh SM, Suzina AH, Dinsuhaimi S, Samsudin AR, Singh GD
    J Oral Rehabil, 2009 Mar;36(3):184-92.
    PMID: 19207445 DOI: 10.1111/j.1365-2842.2008.01915.x
    The association between dental arch morphology and the aetiology of obstructive sleep apnoea (OSA) is not clear. To compare dental arch morphology in 108 Asian adults with and without ''OSA, overnight'' hospital polysomnography was performed, and sleep reports were obtained for all subjects. Standardized digital photographs were also taken of the subjects' upper and lower study models. Using 25 homologous landmarks, mean OSA and control dental arch configurations were computed, and subjected to finite-element morphometry (FEM), t-tests and principal components analysis (PCA). Mean upper and lower OSA dental arch morphologies were statistically different from respective Control upper and lower arch morphologies (P < 0.05). FEM of the upper arch indicated that the mean OSA configuration was 7-11% narrower in the transverse plane in the incisor and canine regions when compared with the control configuration, and inter-landmark analysis (ILA) confirmed this finding. FEM for the lower arch indicated that the mean OSA configuration was 10-11% narrower in the antero-posterior plane in the pre-molar and molar regions, and confirmed by ILA. Using PCA, significant differences were also found between the two groups in the lower arch using the first two eigenvalues, which accounted for 90% of the total shape change (P < 0.001). Supporting their role as aetiological factors, size and shape differences in dental arch morphology are found in patients with OSA.
    Matched MeSH terms: Dental Models
  7. Banabilh SM, Rajion ZA, Samsudin R, Singh GD
    Aust Orthod J, 2006 Nov;22(2):99-103.
    PMID: 17203572
    To quantify and localise differences in Class I and Class II dental arches in Malay schoolchildren.
    Matched MeSH terms: Dental Models
  8. Sockalingam S
    J Indian Soc Pedod Prev Dent, 2011 Jan-Mar;29(1):53-6.
    PMID: 21521920 DOI: 10.4103/0970-4388.79938
    Amelogenesis imperfecta represents a group of dental developmental conditions that are genomic in origin. Hypoplastic AI, hypomineralised AI or both in combination were the most common types seen clinically. This paper describes oral rehabilitation of a 9-year-old Malay girl with inherited hypoplastic AI using transparent thermoforming templates. The defective surface areas were reconstructed to their original dimensions on stone cast models of the upper and lower arches using composite, and transparent thermoform templates were fabricated on the models. The templates were used as crown formers to reconstruct the defective teeth clinically using esthetically matching composite. The usage of the templates allowed direct light curing of the composite, accurate reproducibility of the anatomic contours of the defective teeth, reduced chair-side time and easy contouring and placement of homogenous thickness of composite in otherwise inaccessible sites of the affected teeth.
    Matched MeSH terms: Dental Models
  9. Arshad AI, Alam MK, Khamis MF
    Cleft Palate Craniofac J, 2018 05;55(5):682-687.
    PMID: 29518343 DOI: 10.1177/1055665618758278
    OBJECTIVES: The aim of this study is to assess the treatment outcome of complete unilateral cleft lip and palate (CUCLP) patients using modified Huddart/Bodenham scoring system (MHB). To determine whether there is an association of congenital and postnatal factors with the treatment outcome.

    DESIGN: Retrospective observational study.

    SETTING: Two regional cleft-referral centers.

    MAIN OUTCOME MEASURES: In the current study, 101 pairs of dental models of non-syndromic CUCLP patients were retrieved from hospital archives. Each occlusal relationship from central incisor till the first permanent molars were scored except the lateral incisor. Sum of 10 occlusal relationships in each study sample gave a total occlusion score. The primary outcome was the mean total occlusion score.

    RESULTS: According to MHB, a mean (standard deviation) total occlusion score of -8.92 (6.89) was determined. Based on treatment outcome, 66 cases were favorable (grades 1, 2, and 3) and 35 cases were unfavorable (grades 4 and 5). Chi-square tests indicated, difference of cheiloplasty ( P = .001) and palatoplasty ( P < .001) statistically significant. Five variables-gender, family history of cleft, cleft side, cheiloplasty, and palatoplasty-were analyzed with a logistic regression model.

    CONCLUSIONS: Final model indicated that cases treated with modified Millard technique (cheiloplasty) and Veau-Wardill-Kilner method (palatoplasty) had higher odds of unfavorable treatment outcome.

    Matched MeSH terms: Dental Models
  10. Zreaqat M, Hassan R, Halim AS
    Cleft Palate Craniofac J, 2009 May;46(3):326-30.
    PMID: 19642750 DOI: 10.1597/07-210.1
    To determine the treatment outcome based on dentoalveolar relationships among Malay children born with nonsyndromic complete unilateral cleft lip and palate (UCLP).
    Matched MeSH terms: Dental Models
  11. Al-Makramani BMA, Razak AAA, Abu-Hassan MI
    J Prosthodont, 2008 Feb;17(2):120-124.
    PMID: 18047490 DOI: 10.1111/j.1532-849X.2007.00270.x
    PURPOSE: The current study investigated the effect of different luting agents on the fracture resistance of Procera AllCeram copings.

    METHODS: Six master dies were duplicated from the prepared maxillary first premolar tooth using nonprecious metal alloy (Wiron 99). Thirty copings (Procera AllCeram) of 0.6-mm thickness were manufactured. Three types of luting media were used: zinc phosphate cement (Elite), glass ionomer cement (Fuji I), and dual-cured composite resin cement (Panavia F). Ten copings were cemented with each type. Two master dies were used for each group, and each of them was used to lute five copings. All groups were cemented according to manufacturer's instructions and received a static load of 5 kg during cementation. After 24 hours of distilled water storage at 37 degrees C, the copings were vertically compressed using a universal testing machine at a crosshead speed of 1 mm/min.

    RESULTS: ANOVA revealed significant differences in the load at fracture among the three groups (p < 0.001). The fracture strength results showed that the mean fracture strength of zinc phosphate cement (Elite), glass ionomer cement (Fuji I), and resin luting cement (Panavia F) were 1091.9 N, 784.8 N, and 1953.5 N, respectively.

    CONCLUSION: Different luting agents have an influence on the fracture resistance of Procera AllCeram copings.

    Matched MeSH terms: Dental Models
  12. Tarib NA, Seong TW, Chuen KM, Kun MS, Ahmad M, Kamarudin KH
    Eur J Prosthodont Restor Dent, 2012 Mar;20(1):35-9.
    PMID: 22474935
    This paper aims to evaluate the effect of splinting during implant impression. A master model with two fixtures at the sites of 45 and 47 was used. 20 impressions were made for all four techniques: (A) indirect; (B) direct, unsplinted; (C) direct, splinted; and (D) direct, splinted, sectioned, and re-splinted. Splinting was undertaken with autopolymerizing acrylic resin (AAR). Horizontal distance between fixtures was compared using a digital caliper. The difference in distance were analysed with one-way ANOVA. Group A showed a significantly lowest accuracy among all techniques (p < or = 0.05). There was no significant difference of accuracy among the groups using direct techniques (p > or = 0.05). Group D was more accurate compared to group B and C. We conclude that splinting of impression copings would be beneficial to obtain an accurate impression.
    Matched MeSH terms: Dental Models
  13. Ishak MI, Kadir MR, Sulaiman E, Kasim NH
    Int J Oral Maxillofac Implants, 2013 May-Jun;28(3):e151-60.
    PMID: 23748334 DOI: 10.11607/jomi.2304
    To compare the extramaxillary approach with the widely used intrasinus approach via finite element method.
    Matched MeSH terms: Dental Models*
  14. Abu-Rub N, Samsudin AR, Abdullah AB, Abdullah N
    Aust Orthod J, 2005 May;21(1):39-43.
    PMID: 16433080
    Presurgical orthopaedics has been employed since the 1950s as an adjunctive neonatal therapy for the correction of cleft lip and palate. It is accepted that presurgical orthopaedic plates facilitate lip repair and balanced orofacial growth.
    Matched MeSH terms: Dental Models
  15. Zabidin N, Mohamed AM, Zaharim A, Marizan Nor M, Rosli TI
    Int Orthod, 2018 03;16(1):133-143.
    PMID: 29478934 DOI: 10.1016/j.ortho.2018.01.009
    OBJECTIVES: To evaluate the relationship between human evaluation of the dental-arch form, to complete a mathematical analysis via two different methods in quantifying the arch form, and to establish agreement with the fourth-order polynomial equation.

    MATERIALS AND METHODS: This study included 64 sets of digitised maxilla and mandible dental casts obtained from a sample of dental arch with normal occlusion. For human evaluation, a convenient sample of orthodontic practitioners ranked the photo images of dental cast from the most tapered to the less tapered (square). In the mathematical analysis, dental arches were interpolated using the fourth-order polynomial equation with millimetric acetate paper and AutoCAD software. Finally, the relations between human evaluation and mathematical objective analyses were evaluated.

    RESULTS: Human evaluations were found to be generally in agreement, but only at the extremes of tapered and square arch forms; this indicated general human error and observer bias. The two methods used to plot the arch form were comparable.

    CONCLUSION: The use of fourth-order polynomial equation may be facilitative in obtaining a smooth curve, which can produce a template for individual arch that represents all potential tooth positions for the dental arch.

    Matched MeSH terms: Dental Models
  16. Nambiar P, Carson G, Taylor JA, Brown KA
    J Forensic Odontostomatol, 2001 Jun;19(1):5-8.
    PMID: 11494677
    A wad of used chewing gum recovered from the scene of a burglary contained impressions of human teeth. Casts of these impressions displayed unique morphological characteristics which were found to show concordance with corresponding features present on casts of the posterior teeth of a suspect.
    Matched MeSH terms: Dental Models
  17. Shahid F, Alam MK, Khamis MF
    Eur J Dent, 2016 4 21;10(2):176-182.
    PMID: 27095892 DOI: 10.4103/1305-7456.178299
    OBJECTIVE: Comprehensive diagnosis and treatment planning are essential in a successful orthodontic practice. The purpose of this study is to determine and compare intermaxillary tooth size discrepancy (IMTSD) using traditional digital caliper (DC) measurement on plaster dental models and stereomicroscopic digital dental models (SM).

    MATERIALS AND METHODS: The samples were randomly selected from different states of Pakistan. Total 7168 variables were measured on plaster dental casts (128) and SM digital dental models (128) according to the selection criteria. For IMTSD, the 6 variable measured as for anterior tooth size (maxilla, mandibular), overall tooth size (maxilla, mandibular), Bolton's anterior ratios (BAR), and Bolton's overall ratios (BOR). The independent t-test and ANOVA were used for statistical analyses.

    RESULTS: Significant sexual disparities in the sum of anterior tooth size and overall tooth size via DC and SM methods. No significant sexual disparities for BAR and BOR. No statistically significant differences were found in BAR and BOR between DC and SM. No significant differences were found on IMTSD ratio among different arch length and arch perimeters groups.

    CONCLUSIONS: Norms were developed based on DC and SM for IMTSD. Sexual disparities were observed in the sum of teeth size. However, no significant differences in BAR and BOR for IMTSD between the two methods.

    Matched MeSH terms: Dental Models
  18. Keng SB, Foong KW
    Int Dent J, 1996 Apr;46(2):103-7.
    PMID: 8930682
    In the absence of pre-extraction records, investigators have used various methods to aid in the selection and placement of artificial teeth for complete dentures. Natural tooth position and size provide the dentist with an optimal guide. A study was conducted on a group of ethnic Chinese subjects where direct measurements were made of the arch size and width of the maxillary central incisor on stone casts. The anterior arch width represented by the inter-canine cusp tip distance was 35.74 +/- 2.17mm. The mesiodistal diameter of the maxillary central incisor was 8.85 +/- 0.59mm with a range of 7.60mm to 11.20mm. The results of this study was discussed against other findings on the Caucasian, Nigerian and Malay groups. The significance of artificial tooth selection for dentures was highlighted in relation to the results obtained from the study for the group of Chinese and other races.
    Matched MeSH terms: Dental Models
  19. Soh J, Sandham A
    Angle Orthod, 2004 Dec;74(6):769-73.
    PMID: 15673139
    Orthodontic treatment in adults has gained social and professional acceptance in recent years. An assessment of orthodontic treatment need helps to identify individuals who will benefit from treatment and safeguard their interest. The purpose of this study was to assess the objective and subjective levels of orthodontic treatment need in a sample of orthodontically untreated adult Asian males. A sample of male army recruits (n = 339, age 17-22 years, Chinese = 258, Malay = 60, Indian = 21) with no history of orthodontic treatment or craniofacial anomalies participated in the study on a voluntary basis with informed consent. Impressions for study models were taken. Objective treatment need was assessed based on study model analysis using the Index of Orthodontic Treatment Need (IOTN). Questionnaires were used to assess subjective treatment need based on subjective esthetic component (EC) ratings. Fifty percentage of the sample had a definite need for orthodontic treatment (dental health component [DHC] grades 4 and 5), whereas 29.2% had a moderate need for treatment (DHC grades 3). The occlusal trait most commonly identified was dental crossbite. Malay males had the highest percentage with a definite need for treatment for both dental health and esthetic reasons in comparison with Chinese and Indian males. However, there was no difference in the level of treatment need among the ethnic groups (P > .05). No correlation between objective and subjective EC scores was found (P > .05). A high level of investigator-identified treatment need was not supported by a similar level of subject awareness among the adult sample.
    Matched MeSH terms: Dental Models
Filters