Displaying publications 1 - 20 of 50 in total

Abstract:
Sort:
  1. Lye HS, Alias KA, Rusul G, Liong MT
    Ultrason Sonochem, 2012 May;19(3):632-41.
    PMID: 21907608 DOI: 10.1016/j.ultsonch.2011.08.004
    This study aimed to evaluate the effect of ultrasound treatment on the cholesterol removing ability of lactobacilli. Viability of lactobacilli cells was significantly increased (P < 0.05) immediately after treatment, but higher intensity of 100 W and longer duration of 3 min was detrimental on cellular viability (P < 0.05). This was attributed to the disruption of membrane lipid bilayer, cell lysis and membrane lipid peroxidation upon ultrasound treatment at higher intensity and duration. Nevertheless, the effect of ultrasound on membrane properties was reversible, as the viability of ultrasound-treated lactobacilli was increased (P < 0.05) after fermentation at 37 °C for 20 h. The removal of cholesterol by ultrasound-treated lactobacilli via assimilation and incorporation of cholesterol into the cellular membrane also increased significantly (P < 0.05) upon treatment, as observed from the increased ratio of membrane C:P. Results from fluorescence anisotropies showed that most of the incorporated cholesterol was saturated in the regions of phospholipids tails, upper phospholipids, and polar heads of the membrane bilayer.
    Matched MeSH terms: Dose-Response Relationship, Radiation
  2. Alajerami YS, Hashim S, Ramli AT, Saleh MA, Saripan MI, Alzimami K, et al.
    Appl Radiat Isot, 2013 Aug;78:21-5.
    PMID: 23644162 DOI: 10.1016/j.apradiso.2013.03.095
    New glasses Li2CO3-K2CO3-H3BO3 (LKB) co-doped with CuO and MgO, or with TiO2 and MgO, were synthesized by the chemical quenching technique. The thermoluminescence (TL) responses of LKB:Cu,Mg and LKB:Ti,Mg irradiated with 6 MV photons or 6 MeV electrons were compared in the dose range 0.5-4.0 Gy. The standard commercial dosimeter LiF:Mg,Ti (TLD-100) was used to calibrate the TL reader and as a reference in comparison of the TL properties of the new materials. The dependence of the responses of the new materials on (60)Co dose is linear in the range of 1-1000 Gy. The TL yields of both of the co-doped glasses and TLD-100 are greater for electron irradiation than for photon irradiation. The TL sensitivity of LKB:Ti,Mg is 1.3 times higher than the sensitivity of LKB:Cu,Mg and 12 times less than the sensitivity of TLD-100. The new TL dosimetric materials have low effective atomic numbers, good linearity of the dose responses, excellent signal reproducibility, and a simple glow curve structure. This combination of properties makes them suitable for radiation dosimetry.
    Matched MeSH terms: Dose-Response Relationship, Radiation
  3. Entezam A, Khandaker MU, Amin YM, Ung NM, Bradley DA, Maah J, et al.
    PLoS One, 2016;11(5):e0153913.
    PMID: 27149115 DOI: 10.1371/journal.pone.0153913
    Study has been made of the thermoluminescence (TL) response of silica-based Ge-doped cylindrical, flat and photonic crystal fibres (referred to herein as PCF-collapsed) to electron (6, 12 and 20 MeV) and photon (6, 10 MV) irradiation and 1.25 MeV γ-rays, for doses from 0.1 Gy to 100 Gy. The electron and photon irradiations were delivered through use of a Varian Model 2100C linear accelerator located at the University of Malaya Medical Centre and γ-rays delivered from a 60Co irradiator located at the Secondary Standard Dosimetry Laboratory (SSDL), Malaysian Nuclear Agency. Tailor-made to be of various dimensions and dopant concentrations (6-10% Ge), the fibres were observed to provide TL yield linear with radiation dose, reproducibility being within 1-5%, with insensitivity to energy and angular variation. The sensitivity dependency of both detectors with respect to field size follows the dependency of the output factors. For flat fibres exposed to 6 MV X-rays, the 6% Ge-doped fibre provided the greatest TL yield while PCF-collapsed showed a response 2.4 times greater than that of the 6% Ge-doped flat fibres. The response of cylindrical fibres increased with core size. The fibres offer uniform response, high spatial resolution and sensitivity, providing the basis of promising TL systems for radiotherapy applications.
    Matched MeSH terms: Dose-Response Relationship, Radiation
  4. Alawiah A, Bauk S, Marashdeh MW, Nazura MZ, Abdul-Rashid HA, Yusoff Z, et al.
    Appl Radiat Isot, 2015 Oct;104:197-202.
    PMID: 26188687 DOI: 10.1016/j.apradiso.2015.07.011
    In regard to thermoluminescence (TL) applied to dosimetry, in recent times a number of researchers have explored the role of optical fibers for radiation detection and measurement. Many of the studies have focused on the specific dopant concentration, the type of dopant and the fiber core diameter, all key dependencies in producing significant increase in the sensitivity of such fibers. At doses of less than 1 Gy none of these investigations have addressed the relationship between dose response and TL glow peak behavior of erbium (Er)-doped silica cylindrical fibers (CF). For x-rays obtained at accelerating potentials from 70 to 130 kVp, delivering doses of between 0.1 and 0.7 Gy, present study explores the issue of dose response, special attention being paid to determination of the kinetic parameters and dosimetric peak properties of Er-doped CF. The effect of dose response on the kinetic parameters of the glow peak has been compared against other fiber types, revealing previously misunderstood connections between kinetic parameters and radiation dose. Within the investigated dose range there was an absence of supralinearity of response of the Er-doped silica CF, instead sub-linear response being observed. Detailed examination of glow peak response and kinetic parameters has thus been shown to shed new light of the rarely acknowledged issue of the limitation of TL kinetic model and sub-linear dose response of Er-doped silica CF.
    Matched MeSH terms: Dose-Response Relationship, Radiation
  5. Wahidin S, Idris A, Shaleh SR
    Bioresour Technol, 2013 Feb;129:7-11.
    PMID: 23232218 DOI: 10.1016/j.biortech.2012.11.032
    Illumination factors such as length of photoperiod and intensity can affect growth of microalgae and lipid content. In order to optimize microalgal growth in mass culture system and lipid content, the effects of light intensity and photoperiod cycle on the growth of the marine microalgae, Nannochloropsis sp. were studied in batch culture. Nannochloropsis sp. was grown aseptically for 9 days at three different light intensities (50, 100 and 200 μmol m(-2) s(-1)) and three different photoperiod cycles (24:0, 18:06 and 12:12 h light:dark) at 23 °C cultivation temperature. Under the light intensity of 100 μmol m(-2) s(-1) and photoperiod of 18 h light: 6 h dark cycle, Nannochloropsis sp. was found to grow favorably with a maximum cell concentration of 6.5×10(7) cells mL(-1), which corresponds to the growth rate of 0.339 d(-1) after 8 day cultivation and the lipid content was found to be 31.3%.
    Matched MeSH terms: Dose-Response Relationship, Radiation
  6. Nawi SN, Wahib NF, Zulkepely NN, Amin YB, Min UN, Bradley DA, et al.
    Sensors (Basel), 2015;15(8):20557-69.
    PMID: 26307987 DOI: 10.3390/s150820557
    Study has been undertaken of the thermoluminescence (TL) yield of various tailor-made flat cross-section 6 mol% Ge-doped silica fibers, differing only in respect of external dimensions. Key TL dosimetric characteristics have been investigated, including glow curves, dose response, sensitivity, fading and reproducibility. Using a (60)Co source, the samples were irradiated to doses within the range 1 to 10 Gy. Prior to irradiation, the flat fibers were sectioned into 6 mm lengths, weighed, and annealed at 400 °C for 1 h. TL readout was by means of a Harshaw Model 3500 TLD reader, with TLD-100 chips (LiF:Mg, Ti) used as a reference dosimeter to allow the relative response of the fibers to be evaluated. The fibers have been found to provide highly linear dose response and excellent reproducibility over the range of doses investigated, demonstrating high potential as TL-mode detectors in radiation medicine applications. Mass for mass, the results show the greatest TL yield to be provided by fibers of the smallest cross-section, analysis indicating this to be due to minimal light loss in transport of the TL through the bulk of the silica medium.
    Matched MeSH terms: Dose-Response Relationship, Radiation
  7. Alyahyawi A, Jupp T, Alkhorayef M, Bradley DA
    Appl Radiat Isot, 2018 Aug;138:45-49.
    PMID: 28780202 DOI: 10.1016/j.apradiso.2017.07.011
    In the modern clinical practice of diagnostic radiology there is a growing demand for radiation dosimetry, it also being recognized that with increasing use of X-ray examinations additional population dose will result, accompanied by an additional albeit low potential for genetic consequences. At the doses typical of diagnostic radiology there is also a low statistical risk for cancer induction; in adhering to best practice, to be also implied is a low but non-negligible potential for deterministic sensitive organ responses, including in regard to the skin and eyes. Risk reduction is important, in line with the principle of ALARP, both in regard to staff and patients alike; for the latter modern practice is usually guided by Dose Reference Levels (DRL) while for the former and members of the public, legislated controls (supported by safe working practices) pertain. As such, effective, reliable and accurate means of dosimetry are required in support of these actions. Recent studies have shown that Ge-doped-silica glass fibres offer several advantages over the well-established phosphor-based TL dosimeters (TLD), including excellent sensitivity at diagnostic doses as demonstrated herein, low fading, good reproducibility and re-usability, as well as representing a water impervious, robust dosimetric system. In addition, these silica-based fibres show good linearity over a wide dynamic range of dose and dose-rate and are directionally independent. In the present study, we investigate tailor made doped-silica glass thermoluminescence (TL) for applications in medical diagnostic imaging dosimetry. The aim is to develop a dosimeter of sensitivity greater than that of the commonly used LiF (Mg,Ti) phosphor. We examine the ability of such doped glass media to detect the typically low levels of radiation in diagnostic applications (from fractions of a mGy through to several mGy or more), including, mammography and dental radiology, use being made of x-ray tubes located at the Royal Surrey County Hospital. We further examine dose-linearity, energy response and fading.
    Matched MeSH terms: Dose-Response Relationship, Radiation
  8. Yeang HY
    New Phytol, 2007;175(2):283-9.
    PMID: 17587376
    How tropical trees flower synchronously near the equator in the absence of significant day length variation or other meteorological cues has long been a puzzle. The rubber tree (Hevea brasiliensis) is used as a model to investigate this phenomenon. The annual cycle of solar radiation intensity is shown to correspond closely with the flowering of the rubber tree planted near the equator and in the subtropics. Unlike in temperate regions, where incoming solar radiation (insolation) is dependent on both day length and radiation intensity, insolation at the equator is due entirely to the latter. Insolation at the upper atmosphere peaks twice a year during the spring and autumn equinoxes, but the actual solar radiation that reaches the ground is attenuated to varying extents in different localities. The rubber tree shows one or two flowering seasons a year (with major and minor seasons in the latter) in accordance with the solar radiation intensity received. High solar radiation intensity, and in particular bright sunshine (as distinct from prolonged diffuse radiation), induces synchronous anthesis and blooming in Hevea around the time of the equinoxes. The same mechanism may be operational in other tropical tree species.
    Matched MeSH terms: Dose-Response Relationship, Radiation
  9. Mohd Asri MT, Elias S, Iskandar SM, Abd Halim S, Jumiah H, Zaki AR, et al.
    Med J Malaysia, 2004 May;59 Suppl B:139-40.
    PMID: 15468857
    The aim of this work was to study radiation and the effects of temperature on conductivity properties of polyvinyl alcohol (PVA)-based potassium hydroxide (KOH) and propylene carbonate (PC), where the ionic conduction preferentially occurs in the amorphous phase by free radicals ions through gamma-irradiation. Alkaline composite polymer electrolyte (ACPE) consisting of PVA, KOH and PC of different concentration ratios were prepared by solvent-casting technique. The ACPE were irradiated with different doses from 5 kGy up to 200 kGy. The conductivity properties of the electrolyte films were measured at different frequencies in the range 20 Hz to 1 MHz using LCR meter. The results showed that the conductivity properties were dependent on the radiation dose, temperature and the concentration of the polymer blends.
    Matched MeSH terms: Dose-Response Relationship, Radiation
  10. Mohd S, Ghazali MI, Yusof N, Sulaiman S, Ramalingam S, Kamarul T, et al.
    Cell Tissue Bank, 2018 Dec;19(4):613-622.
    PMID: 30056604 DOI: 10.1007/s10561-018-9711-4
    Air-dried and sterilized amnion has been widely used as a dressing to treat burn and partial thickness wounds. Sterilisation at the standard dose of 25 kGy was reported to cause changes in the morphological structure as observed under the scanning electron microscope. This study aimed to quantify the changes in the ultrastructure of the air-dried amnion after gamma-irradiated at several doses by using atomic force microscope. Human placentae were retrieved from mothers who had undergone cesarean elective surgery. Amnion separated from chorion was processed and air-dried for 16 h. It was cut into 10 × 10 mm, individually packed and exposed to gamma irradiation at 5, 15, 25 and 35 kGy. Changes in the ultrastructural images of the amnion were quantified in term of diameter of the epithelial cells, size of the intercellular gap and membrane surface roughness. The longest diameter of the amnion cells reduced significantly after radiation (p dose dependent. No significant changes in the shortest diameter after radiation, except at 35 kGy which decreased significantly when compared to 5 kGy (p 
    Matched MeSH terms: Dose-Response Relationship, Radiation
  11. Chow MC, Ma AN
    PMID: 17645207
    Microwave heating was determined in this study to be suitable for the detachment and drying of palm fruits from whole bunches, cut bunches and spikelets. Microwave treatment of the palm fruits was able to attain the objectives of conventional fresh palm fruits sterilization processeses such as fruit softening, nut conditioning and halting of enzymatic lipolysis. Palm oil and kernel oil solvent extracted respectively from the microwave treated whole fruits and kernel were found to have a good quality of low free fatty acid content. This technology, together with the solvent extraction of the dehydrated fruits, may have the potential to be a continuous, dry and clean technology for palm oil milling.
    Matched MeSH terms: Dose-Response Relationship, Radiation
  12. Shulman ST
    Pediatr Ann, 2008 Jun;37(6):368-9.
    PMID: 18616187
    Matched MeSH terms: Dose-Response Relationship, Radiation
  13. Yusof FH, Ung NM, Wong JH, Jong WL, Ath V, Phua VC, et al.
    PLoS One, 2015;10(6):e0128544.
    PMID: 26052690 DOI: 10.1371/journal.pone.0128544
    This study was carried out to investigate the suitability of using the optically stimulated luminescence dosimeter (OSLD) in measuring surface dose during radiotherapy. The water equivalent depth (WED) of the OSLD was first determined by comparing the surface dose measured using the OSLD with the percentage depth dose at the buildup region measured using a Markus ionization chamber. Surface doses were measured on a solid water phantom using the OSLD and compared against the Markus ionization chamber and Gafchromic EBT3 film measurements. The effect of incident beam angles on surface dose was also studied. The OSLD was subsequently used to measure surface dose during tangential breast radiotherapy treatments in a phantom study and in the clinical measurement of 10 patients. Surface dose to the treated breast or chest wall, and on the contralateral breast were measured. The WED of the OSLD was found to be at 0.4 mm. For surface dose measurement on a solid water phantom, the Markus ionization chamber measured 15.95% for 6 MV photon beam and 12.64% for 10 MV photon beam followed by EBT3 film (23.79% and 17.14%) and OSLD (37.77% and 25.38%). Surface dose increased with the increase of the incident beam angle. For phantom and patient breast surface dose measurement, the response of the OSLD was higher than EBT3 film. The in-vivo measurements were also compared with the treatment planning system predicted dose. The OSLD measured higher dose values compared to dose at the surface (Hp(0.0)) by a factor of 2.37 for 6 MV and 2.01 for 10 MV photon beams, respectively. The measurement of absorbed dose at the skin depth of 0.4 mm by the OSLD can still be a useful tool to assess radiation effects on the skin dermis layer. This knowledge can be used to prevent and manage potential acute skin reaction and late skin toxicity from radiotherapy treatments.
    Matched MeSH terms: Dose-Response Relationship, Radiation
  14. Farayola MF, Shafie S, Mohd Siam F, Khan I
    Comput Methods Programs Biomed, 2020 Apr;187:105202.
    PMID: 31835107 DOI: 10.1016/j.cmpb.2019.105202
    Background This paper presents a numerical simulation of normal and cancer cells' population dynamics during radiotherapy. The model used for the simulation was the improved cancer treatment model with radiotherapy. The model simulated the population changes during a fractionated cancer treatment process. The results gave the final populations of the cells, which provided the final volumes of the tumor and normal cells. Method The improved model was obtained by integrating the previous cancer treatment model with the Caputo fractional derivative. In addition, the cells' population decay due to radiation was accounted for by coupling the linear-quadratic model into the improved model. The simulation of the treatment process was done with numerical variables, numerical parameters, and radiation parameters. The numerical variables include the populations of the cells and the time of treatment. The numerical parameters were the model factors which included the proliferation rates of cells, competition coefficients of cells, and perturbation constant for normal cells. The radiation parameters were clinical data based on the treatment procedure. The numerical parameters were obtained from the previous literature while the numerical variables and radiation parameters, which were clinical data, were obtained from reported data of four cancer patients treated with radiotherapy. The four cancer patients had tumor volumes of 28.4 cm3, 18.8 cm3, 30.6 cm3, and 12.6 cm3 and were treated with different treatment plans and a fractionated dose of 1.8 Gy each. The initial populations of cells were obtained by using the tumor volumes. The computer simulations were done with MATLAB. Results The final volumes of the tumors, from the results of the simulations, were 5.67 cm3, 4.36 cm3, 5.74 cm3, and 6.15 cm3 while the normal cells' volumes were 28.17 cm3, 18.68 cm3, 30.34 cm3, and 12.54 cm3. The powers of the derivatives were 0.16774, 0.16557, 0.16835, and 0.16. A variance-based sensitivity analysis was done to corroborate the model with the clinical data. The result showed that the most sensitive factors were the power of the derivative and the cancer cells' proliferation rate. Conclusion The model provided information concerning the status of treatments and can also predict outcomes of other treatment plans.
    Matched MeSH terms: Dose-Response Relationship, Radiation
  15. Mizuno H, Fukuda S, Fukumura A, Nakamura YK, Jianping C, Cho CK, et al.
    J Radiat Res, 2017 May 01;58(3):372-377.
    PMID: 27864507 DOI: 10.1093/jrr/rrw108
    A dose audit of 16 facilities in 11 countries has been performed within the framework of the Forum for Nuclear Cooperation in Asia (FNCA) quality assurance program. The quality of radiation dosimetry varies because of the large variation in radiation therapy among the participating countries. One of the most important aspects of international multicentre clinical trials is uniformity of absolute dose between centres. The National Institute of Radiological Sciences (NIRS) in Japan has conducted a dose audit of participating countries since 2006 by using radiophotoluminescent glass dosimeters (RGDs). RGDs have been successfully applied to a domestic postal dose audit in Japan. The authors used the same audit system to perform a dose audit of the FNCA countries. The average and standard deviation of the relative deviation between the measured and intended dose among 46 beams was 0.4% and 1.5% (k = 1), respectively. This is an excellent level of uniformity for the multicountry data. However, of the 46 beams measured, a single beam exceeded the permitted tolerance level of ±5%. We investigated the cause for this and solved the problem. This event highlights the importance of external audits in radiation therapy.
    Matched MeSH terms: Dose-Response Relationship, Radiation*
  16. Ling AP, Ung YC, Hussein S, Harun AR, Tanaka A, Yoshihiro H
    J Zhejiang Univ Sci B, 2013 Dec;14(12):1132-43.
    PMID: 24302713 DOI: 10.1631/jzus.B1200126
    Heavy ion beam, which has emerged as a new mutagen in the mutation breeding of crops and ornamental plants, is expected to result in the induction of novel mutations. This study investigates the morphological and biochemical responses of Oryza sativa toward different doses of carbon ion beam irradiation.
    Matched MeSH terms: Dose-Response Relationship, Radiation
  17. Foo KY, Hameed BH
    Bioresour Technol, 2012 Sep;119:234-40.
    PMID: 22728787 DOI: 10.1016/j.biortech.2012.05.061
    Microwave heating was used in the regeneration of methylene blue-loaded activated carbons produced from fibers (PFAC), empty fruit bunches (EFBAC) and shell (PSAC) of oil palm. The dye-loaded carbons were treated in a modified conventional microwave oven operated at 2450 MHz and irradiation time of 2, 3 and 5 min. The virgin properties of the origin and regenerated activated carbons were characterized by pore structural analysis and nitrogen adsorption isotherm. The surface chemistry was examined by zeta potential measurement and determination of surface acidity/basicity, while the adsorptive property was quantified using methylene blue (MB). Microwave irradiation preserved the pore structure, original active sites and adsorption capacity of the regenerated activated carbons. The carbon yield and the monolayer adsorption capacities for MB were maintained at 68.35-82.84% and 154.65-195.22 mg/g, even after five adsorption-regeneration cycles. The findings revealed the potential of microwave heating for regeneration of spent activated carbons.
    Matched MeSH terms: Dose-Response Relationship, Radiation
  18. Daood U, Fawzy AS
    Arch Oral Biol, 2019 Feb;98:195-203.
    PMID: 30502562 DOI: 10.1016/j.archoralbio.2018.10.019
    OBJECTIVE: To investigate effects of HIFU on macrophage phenotype, surface micro-topography and nano-scale surface mechanical properties of dental cementum.

    MATERIALS AND METHODS: Root discs (2 mm thickness) were cut apical to CEJ and sectioned into quadrants. HIFU setup with bowl-shaped piezo ceramic transducer submerged in a water tank was used for exposure on each specimen for 15 s, 30 s or 60 s. The specimens of the control group were left without any HIFU exposure. HIFU was generated with a continuous sinusoidal wave of 120Vpp amplitude, 250 KHZ resonance-frequency and highest ultrasonic pressure of ∼10 bar at the focus. Specimens for SEM were viewed, and micro-topography characterization performed, using AFM and Ra parameter and surface area (SA) calculated by specialized SPM surface analysis software. For nano-indentation testing, experiments were carried out using AFM. Macrophage cell isolation and culturing was performed on cementum to receive the HIFU treatment at different time periods. Raman spectroscopy were scanned to create spectra perpendicular to the cementum substrate to analyze generation of standard spectra for Raman intensity ratio of hydroxyapatite normalized to the peaks ν1 960 cm-1. Data was expressed as means ± standard deviations and analyzed by one-way ANOVA in term of Ra, SA, H and Er. Different points for fluorescence intensity ratio were analyzed by Raman using Wilcoxon rank sum test.

    RESULTS: HIFU exposure at 60 s removed the smear layer and most of cementum appeared smoothened. AFM characterisation, showed a slight decrease in the irregularity of the surface as exposure time increased. Intact macrophages can be identified in control and all experimental HIFU groups. The level of fluorescence for the control and HIFU 15 and 30 s were low as compared to HIFU 60 s.

    CONCLUSION: If HIFU can be successfully implemented, it may be a possible alternative to current methods used in periodontal therapy to achieve smooth root surfaces.

    Matched MeSH terms: Dose-Response Relationship, Radiation
  19. Al Musawi MS, Jaafar MS, Al-Gailani B, Ahmed NM, Suhaimi FM
    Lasers Med Sci, 2017 Dec;32(9):2089-2095.
    PMID: 28967036 DOI: 10.1007/s10103-017-2340-5
    The study of the effects of low-level laser (LLL) radiation on blood is important for elucidating the mechanisms behind the interaction of LLL radiation and biologic tissues. Different therapy methods that involve blood irradiation have been developed and used for clinical purposes with beneficial effects. The aim of this study was to compare the effects of different irradiation protocols using a diode-pumped solid-state LLL (λ = 405 nm) on samples of human blood by measuring the erythrocyte sedimentation rate (ESR). Human blood samples were obtained through venipuncture into tubes containing EDTA as an anticoagulant. Every sample was divided into two equal aliquots to be used as an irradiated sample and a non-irradiated control sample. The irradiated aliquot was subjected to a laser beam with a wavelength of 405 nm and an energy density of 72 J/cm2. The radiation source had a fixed irradiance of 30 mW/cm2. The ESR change was observed for three different experimental protocols: irradiated whole blood, irradiated red blood cells (RBCs) samples re-suspended in non-irradiated blood plasma, and non-irradiated RBCs re-suspended in irradiated blood plasma. The ESR values were measured after laser irradiation and compared with the non-irradiated control samples. Irradiated blood plasma in which non-radiated RBCs were re-suspended was found to result in the largest ESR decrease for healthy human RBCs, 51%, when compared with RBCs re-suspended in non-irradiated blood plasma. The decrease in ESR induced by LLL irradiation of the plasma alone was likely related to changes in the plasma composition and an increase in the erythrocyte zeta potential upon re-suspension of the RBCs in the irradiated blood plasma.
    Matched MeSH terms: Dose-Response Relationship, Radiation
  20. Topkaya D, Ng SY, Bretonnière Y, Lafont D, Chung LY, Lee HB, et al.
    Photodiagnosis Photodyn Ther, 2016 Dec;16:12-14.
    PMID: 27475243 DOI: 10.1016/j.pdpdt.2016.07.008
    Matched MeSH terms: Dose-Response Relationship, Radiation
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links