Displaying publications 1 - 20 of 26 in total

Abstract:
Sort:
  1. Ng CK, Chen JY, Yeh JZY, Ho JPY, Merican AM, Yeo SJ
    J Arthroplasty, 2018 06;33(6):1936-1944.
    PMID: 29395720 DOI: 10.1016/j.arth.2017.12.025
    BACKGROUND: We hypothesized that there is a correlation between the distal femoral rotation and proximal tibial joint line obliquity in nonarthritic knees. This has significance for kinematic knee arthroplasty, in which the target knee alignment desired approximates the knee before disease.

    METHODS: Fifty computed tomography scans of nonarthritic knees were evaluated using three-dimensional image processing software. Four distal femoral rotational axes were determined in the axial plane: the transepicondylar axis (TEA), transcondylar axis (TCA), posterior condylar axis (PCA), and a line perpendicular to Whiteside's anterior-posterior axis. Then, angles were measured relative to the TEA. Tibial joint line obliquity was measured as the angle between the proximal tibial plane and a line perpendicular to the axis of the tibia.

    RESULTS: There was a strong positive correlation between PCA-TEA and tibial joint line obliquity (r = 0.68, P < .001) as well as TCA-TEA and tibial joint line obliquity (r = 0.69, P < .001). In addition, the tibial joint line obliquity and TCA-TEA angles were similar, 3.7° ± 2.2° (mean ± standard deviation) and 3.5° ± 1.7°, respectively (mean difference, 0.2° ± 0.2°; P = .369).

    CONCLUSION: Both PCA-TEA and TCA-TEA strongly correlated with proximal tibial joint line obliquity indicating a relationship between distal femoral rotational geometry and proximal tibial inclination. These findings could imply that the native knee in flexion attempts to balance the collateral ligaments toward a rectangular flexion space. A higher tibial varus inclination is matched with a more internally rotated distal femur relative to the TEA.

    Matched MeSH terms: Femur/surgery*
  2. Hwang PX, Wang CK
    Injury, 2023 Nov;54(11):111038.
    PMID: 37741171 DOI: 10.1016/j.injury.2023.111038
    We have read the paper "Important tips and numbers on using the cortical step and diameter difference sign in assessing femoral rotation - Should we abandon the technique?" [1] with great interest. Restoring femoral rotation during intramedullary nailing can pose challenges to many experienced surgeons. Femur rotational side-to-side asymmetry which is greater than 10 ° will cause functional deficit. We propose a surgical technique which allows surgeons to evaluate and reduce the malrotated femur intraoperatively. This technique also improves the ergonomics of the surgery and can be used simultaneously with other femoral rotation evaluation techniques. LEVEL OF EVIDENCE: V.
    Matched MeSH terms: Femur/surgery
  3. Saravanan S, Vivek AS
    Med J Malaysia, 2007 Dec;62(5):418-9.
    PMID: 18705481 MyJurnal
    This is to report on the use of growing endoprosthesis, also known as lengthening prosthesis in the management of four patients in the paedriatic age group in the Orthopaedic Oncolgy Unit at University Malaya Medical Centre. These are custom made prosthesis, designed and made in India based on measured roentrograms. The ages of these patients vary from 6 to 13 years old. These are cases of Osteosarcoma and Ewing's sarcoma around the knee. This is the first time these custom made prosthesis have ever been used in Malaysia. We feel that this is a feasible option for limb salvage in the treatment of primary bone tumours in growing children.
    Matched MeSH terms: Femur/surgery*
  4. Sulaiman AR, Munajat I, Liau KM, Salehuddin AY, Shukrimi A
    Med J Malaysia, 2006 Dec;61 Suppl B:48-50.
    PMID: 17600992
    Distraction osteogeneis over intramedullary nail has a benefit of decreasing the time for external fixation thus reducing the rate of associated complications. However, risk of panosteomyelitis is still the major worry. We are reporting two patients who underwent the procedure. The first case was a 13-year-old girl requiring 6 cm of femoral lengthening and the second case was a 17-year-old girl who required 5 cm of tibial lengthening. The healing index was 19.5 days/cm and 14.8 days/cm respectively, compared favorably to 30 days/cm with traditional method of distraction osteogenesis. There were mild pin tract infections and joint stiffness which responded to non-operative treatment.
    Matched MeSH terms: Femur/surgery*
  5. Zainal Abidin NA, Abdul Wahab AH, Abdul Rahim RA, Abdul Kadir MR, Ramlee MH
    Med Biol Eng Comput, 2021 Sep;59(9):1945-1960.
    PMID: 34392448 DOI: 10.1007/s11517-021-02419-6
    Complication rates of anterior cruciate ligament reconstruction (ACL-R) were reported to be around 15% although it is a common arthroscopic procedure with good outcomes. Breakage and migration of fixators are still possible even months after surgery. A fixator with optimum stability can minimise those two complications. Factors that affect the stability of a fixator are its configuration, material, and design. Thus, this paper aims to analyse the biomechanical effects of different types of fixators (cross-pin, interference screw, and cortical button) towards the stability of the knee joint after ACL-R. In this study, finite element modelling and analyses of a knee joint attached with double semitendinosus graft and fixators were carried out. Mimics and 3-Matic softwares were used in the development of the knee joint models. Meanwhile, the graft and fixators were designed by using SolidWorks software. Once the meshes of all models were finished in 3-Matic, simulation of the configurations was done using MSC Marc Mentat software. A 100-N anterior tibial load was applied onto the tibia to simulate the anterior drawer test. Based on the findings, cross-pin was found to have optimum stability in terms of stress and strain at the femoral fixation site for better treatment of ACL-R.
    Matched MeSH terms: Femur/surgery
  6. Mohamed Thajudeen MZ, Mahmood Merican A, Hashim MS, Nordin A
    Medicine (Baltimore), 2022 Nov 11;101(45):e31398.
    PMID: 36397421 DOI: 10.1097/MD.0000000000031398
    Femoral anteversion is an important parameter that can prevent complication following total hip arthroplasty (THA) caused by improper positioning of the implant. However, assessing femoral anteversion can be challenging in situation with significant defect of the femoral neck. In this study, linea aspera version was nominated as alternative parameter to femoral anteversion. So, the main objective of this study is to determine whether femoral anteversion correlates with linea aspera version. Cross-sectional study. Three-dimensional images of 100 femora were generated and their femoral anteversion and linea aspera version was measured. Correlation between the parameters was calculated. The mean linea aspera version was 7.27° ± 12.17° (mean ± standard deviation) while the mean femoral anteversion was 11.84° ± 10.06°. The linea aspera version was inversely correlated with the femoral anteversion with a correlation coefficient of -0.85. Linea aspera should be considered as an additional bony landmark to assess proper implant positioning in THA.
    Matched MeSH terms: Femur/surgery
  7. Hussain PB, Mohammad M
    Med J Malaysia, 2004 May;59 Suppl B:180-1.
    PMID: 15468877
    Failure analysis was performed to investigate the failure of the femur fixation plate which was previously fixed on the femur of a girl. Radiography, metallography, fractography and mechanical testing were conducted in this study. The results show that the failure was due to the formation of notches on the femur plate. These notches act as stress raisers from where the cracks start to propagate. Finally fracture occurred on the femur plate and subsequently, the plate failed.
    Matched MeSH terms: Femur/surgery*
  8. Lee M, Ho JPY, Chen JY, Ng CK, Yeo SJ, Merican AM
    J Knee Surg, 2022 Feb;35(3):280-287.
    PMID: 32629512 DOI: 10.1055/s-0040-1713733
    BACKGROUND:  Restoration of the anatomical joint line, while important for clinical outcomes, is difficult to achieve in revision total knee arthroplasty (rTKA) due to distal femoral bone loss. The objective of this study was to determine a reliable method of restoring the anatomical joint line and posterior condylar offset in the setting of rTKA based on three-dimensional (3D) reconstruction of computed tomography (CT) images of the distal femur.

    METHODS:  CT scans of 50 lower limbs were analyzed. Key anatomical landmarks such as the medial epicondyle (ME), lateral epicondyle, and transepicondylar width (TEW) were determined on 3D models constructed from the CT images. Best-fit planes placed on the most distal and posterior loci of points on the femoral condyles were used to define the distal and posterior joint lines, respectively. Statistical analysis was performed to determine the relationships between the anatomical landmarks and the distal and posterior joint lines.

    RESULTS:  There was a strong correlation between the distance from the ME to the distal joint line of the medial condyle (MEDC) and the distance from the ME to the posterior joint line of the medial condyle (MEPC) (p 

    Matched MeSH terms: Femur/surgery
  9. Fong TS, Kim SC, Kim JE, Lee ES, Kim TW, Lee YS
    J Arthroplasty, 2019 09;34(9):1929-1937.
    PMID: 31138501 DOI: 10.1016/j.arth.2019.04.061
    BACKGROUND: This study aimed at assessing the morphometry of resected femurs in Korean patients during total knee arthroplasty (TKA) and comparing these measurements with current Western-designed femoral component dimensions.

    METHODS: This single-blind, prospective, randomized, controlled trial involved intraoperative measurements for 271 femoral component implantations from 3 contemporary TKA systems, with 2 systems offering narrow sizing options. The difference between femoral component dimensions and the resected surface of distal femur was measured in millimeters at 5 distinct zones.

    RESULTS: Overhang of standard femoral component was common in the anterior-medial condyle and anterior-lateral condyle ranging from 50.8% to 99.0% and 21.5% to 88.0%, respectively. With narrow femoral components, the rate of overhang reduced to 21.5%-30.2% and 9.2%-32.1%. Conversely, underhang rates were higher over the anterior flange width, middle medial-lateral and posterior medial-lateral zones. Standard components displayed higher underhang rates at these zones compared to narrow components. The good fit rate for femoral component was low among the 3 systems ranging from 1.0% to 56.0%. System with narrow option sizing increases the underhang rates in males, while improving the component fit among females at similar zones with rate ranging from 5.2% to 52.9%.

    CONCLUSION: Currently available TKA implant designs may not provide a perfect match for the distal femoral shape of the Korean population. The availability of implants with standard and narrow options can substantially improve the optimal fitting of femoral components in the Korean population.

    Matched MeSH terms: Femur/surgery*
  10. Lee JK
    Int J Rheum Dis, 2009 Jul;12(2):149-54.
    PMID: 20374333 DOI: 10.1111/j.1756-185X.2009.01396.x
    Antiresorptive agents have been used as primary or first-line therapy in managing patients with osteoporosis. Bisphosphonates in particular are used widely to reduce bone resorption, increase bone mineral density, improve bone quality and therefore reduce fracture risk. However, prolonged use of bisphosphonates may cause over-suppression of bone resorption, leading on to accumulation of micro-damage in bone. This in turn might lead on to atypical femoral fractures. A patient treated with alendronate sodium for 8 years, and presenting with bilateral atypical femoral diaphyseal fractures is reported. X-rays of both femurs showed typical horizontal fracture line involving the thick lateral cortex with short oblique fracture pattern over the medial cortex. This fracture pattern was further confirmed with intra-operative examination of the fracture ends. Histopathological examination of the endocortical fragment removed from the proximal fracture end showed absence of osteoclasts and osteoblasts. Bone mineral density with dual energy X-ray absorptiometry (DXA) scan showed osteopenia over the femoral neck. Blood investigations did not show significant abnormalities. Bone turnover marker levels were not reliable, as presence of fracture might have altered the marker levels. Both femoral fractures united well. The patient reported here had complete pictures on X-ray examination, intra-operative findings, histopathological examination, DXA, as well as blood test results. Complete data should be collected from patients treated with alendronate sodium presenting with atypical femoral fractures to show any link between the use of alendronate sodium with atypical fracture of femur.
    Matched MeSH terms: Femur/surgery
  11. Kokubo T
    Med J Malaysia, 2004 May;59 Suppl B:91-2.
    PMID: 15468833
    Metallic materials implanted into bone defects are generally encapsulated by a fibrous tissue. Some metallic materials such as titanium and tantalum, however, have been revealed to bond to the living bone without forming the fibrous tissue, when they were subjected to NaOH solution and heat treatments. Thus treated metals form bone tissue around them even in muscle, when they take a porous form. This kind of osteoconductive and osteoinductive properties are attributed to sodium titanate or tantalate layer on their surfaces formed by the NaOH and heat treatments. These layers induce the deposition of bonelike apatite on the surface of the metals in the living body. This kind of bioactive metals are useful as bone substitutes even highly loaded portions, such as hip joint, spine and tooth root.
    Matched MeSH terms: Femur/surgery
  12. Yoon KH, Kim JS, Park JY, Park SY, Kiat RYD, Kim SG
    Knee Surg Sports Traumatol Arthrosc, 2021 Jun;29(6):1936-1943.
    PMID: 32914218 DOI: 10.1007/s00167-020-06266-0
    PURPOSE: To compare clinical and radiological outcomes and failure rates between anatomical and high femoral tunnels in remnant-preserving single-bundle posterior cruciate ligament (PCL) reconstruction.

    METHODS: 63 patients who underwent remnant-preserving single-bundle PCL reconstruction between 2011 and 2018 with a minimum 2-year follow-up were retrospectively reviewed. Patients were divided into two groups according to the femoral tunnel position: group A (33 patients with anatomical femoral tunnel) and group H (30 patients with high femoral tunnels). The femoral tunnel was positioned at the center (group A) or upper margin (group H) of the remnant anterolateral bundle. The position of the femoral tunnel was evaluated using the grid method on three-dimensional computed tomography. Clinical and radiological outcomes and failure rates were compared between the groups at the 2-year follow-up.

    RESULTS: The position of the femoral tunnel was significantly high in group H than in group A (87.4% ± 4.2% versus 76.1% ± 3.7%, p 

    Matched MeSH terms: Femur/surgery*
  13. Soliman MM, Islam MT, Chowdhury MEH, Alqahtani A, Musharavati F, Alam T, et al.
    J Mater Chem B, 2023 Nov 15;11(44):10507-10537.
    PMID: 37873807 DOI: 10.1039/d3tb01469j
    The UK's National Joint Registry (NJR) and the American Joint Replacement Registry (AJRR) of 2022 revealed that total hip replacement (THR) is the most common orthopaedic joint procedure. The NJR also noted that 10-20% of hip implants require revision within 1 to 10 years. Most of these revisions are a result of aseptic loosening, dislocation, implant wear, implant fracture, and joint incompatibility, which are all caused by implant geometry disparity. The primary purpose of this review article is to analyze and evaluate the mechanics and performance factors of advancement in hip implants with novel geometries. The existing hip implants can be categorized based on two parts: the hip stem and the joint of the implant. Insufficient stress distribution from implants to the femur can cause stress shielding, bone loss, excessive micromotion, and ultimately, implant aseptic loosening due to inflammation. Researchers are designing hip implants with a porous lattice and functionally graded material (FGM) stems, femur resurfacing, short-stem, and collared stems, all aimed at achieving uniform stress distribution and promoting adequate bone remodeling. Designing hip implants with a porous lattice FGM structure requires maintaining stiffness, strength, isotropy, and bone development potential. Mechanical stability is still an issue with hip implants, femur resurfacing, collared stems, and short stems. Hip implants are being developed with a variety of joint geometries to decrease wear, improve an angular range of motion, and strengthen mechanical stability at the joint interface. Dual mobility and reverse femoral head-liner hip implants reduce the hip joint's dislocation limits. In addition, researchers reveal that femoral headliner joints with unidirectional motion have a lower wear rate than traditional ball-and-socket joints. Based on research findings and gaps, a hypothesis is formulated by the authors proposing a hip implant with a collared stem and porous lattice FGM structure to address stress shielding and micromotion issues. A hypothesis is also formulated by the authors suggesting that the utilization of a spiral or gear-shaped thread with a matched contact point at the tapered joint of a hip implant could be a viable option for reducing wear and enhancing stability. The literature analysis underscores substantial research opportunities in developing a hip implant joint that addresses both dislocation and increased wear rates. Finally, this review explores potential solutions to existing obstacles in developing a better hip implant system.
    Matched MeSH terms: Femur/surgery
  14. Fallahiarezoodar A, Abdul Kadir MR, Alizadeh M, Naveen SV, Kamarul T
    Knee Surg Sports Traumatol Arthrosc, 2014 Dec;22(12):3019-27.
    PMID: 25149643 DOI: 10.1007/s00167-014-3227-7
    PURPOSE: Reproducing the femoral rollback through specially designed mechanism in knee implants is required to achieve full knee function in total knee arthroplasty. Most contemporary implants use cam/post mechanism to replace the function of Posterior Cruciate Ligament. This study was aimed to determine the most appropriate cam and post designs to produce normal femoral rollback of the knee.

    METHODS: Three different cams (triangle, ellipse, and circle) and three different posts (straight, convex, concave) geometries were considered in this study and were analysed using kinematic analyses. Femoral rollback did not occur until reaching 50° of knee flexion. Beyond this angle, two of the nine combinations demonstrate poor knee flexion and were eliminated from the study.

    RESULTS: The combination of circle cam with concave post, straight post and convex post showed 15.6, 15.9 and 16.1 mm posterior translation of the femur, respectively. The use of ellipse cam with convex post and straight post demonstrated a 15.3 and 14.9 mm femoral rollback, whilst the combination of triangle cam with convex post and straight post showed 16.1 and 15.8 mm femoral rollback, respectively.

    CONCLUSION: The present study demonstrates that the use of circle cam and convex post created the best femoral rollback effect which in turn produces the highest amount of knee flexion. The findings of the study suggest that if the design is applied for knee implants, superior knee flexion may be possible for future patients.

    LEVEL OF EVIDENCE: IV.

    Matched MeSH terms: Femur/surgery*
  15. Doreya MI, Mona EW, Afaf ES, Hanan HB
    Med J Malaysia, 2004 May;59 Suppl B:21-2.
    PMID: 15468799
    The standard bioglass composition GS45 as well as with excess silica GS50 or with the addition of 5% titanium oxide GS45+Ti5, were prepared by the polymeric route. The different glass components were added to the formed polymer. Firing at 700 degrees C gave an amorphous product with microporous texture that readily crystallizes out at 900 degrees C. The prepared materials were highly porous with two modes of pore system micro-pores and macro-pores with a size ranging between 100 microm to 0.006 microm and a porosity reaching 73%. The measured bulk density was between 0.36 to 1.1g/cm3. The fired material preserved the former structure of the polymer precursor. Biocompatibility was verified in vitro and vivo. IR of the specimens previously immersed in SBF revealed the formation of apatite like layer. While the histology sections of implants in rate femurs showed new bone tissue or bone trabeculae after 21 days.
    Matched MeSH terms: Femur/surgery
  16. Imran Y, Zulmi W, Halim AS
    Med J Malaysia, 2004 Dec;59 Suppl F:35-8.
    PMID: 15941158
    Long bone reconstruction using vascularized fibula graft is becoming more popular despite the difficulties and its post-operative complications. We reviewed our early experience dealing with vascularized fibula graft for the management of massive long bone defect. Thirteen patients had undergone long bone reconstruction using vascularized fibula graft. Early complications that had been encountered include superficial wound infection (23%), transient common peroneal nerve palsy (23%), stage 1 bed sore (7.7%), anastomotic venous thrombosis (30.8%), DIVC (15.4%), flap loss and amputation (7.7%), and reactive psychiatric problem (7.7%). The early complications following this procedure are comparable with other major orthopaedic surgery and most of them are minor and treatable. The complication rates are also comparable with similar surgery done elsewhere.
    Matched MeSH terms: Femur/surgery
  17. Lee YS, Lee SH, Lee ES, Fong TS
    BMC Musculoskelet Disord, 2019 Mar 20;20(1):118.
    PMID: 30894158 DOI: 10.1186/s12891-019-2505-4
    BACKGROUND: We report a case of hardware failure after distal femoral osteotomy (DFO) with a broken screw pulled out from the locking hole and positioned within the knee joint.

    CASE PRESENTATION: A 57-year-old man presented to our orthopedic outpatient department with 3-months history of an unusual painful swelling at the operated area following DFO. The leakage of joint fluid from the penetrated suprapatellar pouch was assumed to be the reason for this complication.

    CONCLUSIONS: The overall aim of this case report is to provide a lesson to budding surgeons who might experience a similar situation that cannot be easily explained, like the unexpected complication in the present case.

    Matched MeSH terms: Femur/surgery
  18. Sulaiman AR, Joehaimy J, Iskandar MA, Anwar Hau M, Ezane AM, Faisham WI
    Singapore Med J, 2006 Aug;47(8):684-7.
    PMID: 16865208
    The purpose of this study is to determine the overgrowth phenomenon of the affected femur following plate fixation of femoral fractures in children.
    Matched MeSH terms: Femur/surgery*
  19. Faisham WI, Zulmi W, Biswal BM
    Med J Malaysia, 2003 Mar;58(1):120-4.
    PMID: 14556337
    Since January 1999, ten patients had undergone surgical treatment for metastatic bony lesions of proximal femur at this centre. Seven of these patients were treated for complete pathological fractures, one for impending fracture and one for revision of internal fixation and loosening of hemiarthroplasty. Primary malignancies were located in breast in four cases, prostate in three and one in lung, thyroid and neurofibrosarcoma. Two patients had died within six months after surgery, four after 1 year while the remaining four were still alive. The mean duration of survival was eleven months. Nine patients had been ambulating pain free and there were no failure of reconstruction.
    Matched MeSH terms: Femur/surgery
  20. Latifi MH, Ganthel K, Rukmanikanthan S, Mansor A, Kamarul T, Bilgen M
    Biomed Eng Online, 2012;11:23.
    PMID: 22545650 DOI: 10.1186/1475-925X-11-23
    Effective fixation of fracture requires careful selection of a suitable implant to provide stability and durability. Implant with a feature of locking plate (LP) has been used widely for treating distal fractures in femur because of its favourable clinical outcome, but its potential in fixing proximal fractures in the subtrochancteric region has yet to be explored. Therefore, this comparative study was undertaken to demonstrate the merits of the LP implant in treating the subtrochancteric fracture by comparing its performance limits against those obtained with the more traditional implants; angle blade plate (ABP) and dynamic condylar screw plate (DCSP).
    Matched MeSH terms: Femur/surgery