Displaying publications 1 - 20 of 114 in total

Abstract:
Sort:
  1. Zouache MA, Eames I, Samsudin A
    PLoS One, 2016;11(3):e0151490.
    PMID: 26990431 DOI: 10.1371/journal.pone.0151490
    In vertebrates, intraocular pressure (IOP) is required to maintain the eye into a shape allowing it to function as an optical instrument. It is sustained by the balance between the production of aqueous humour by the ciliary body and the resistance to its outflow from the eye. Dysregulation of the IOP is often pathological to vision. High IOP may lead to glaucoma, which is in man the second most prevalent cause of blindness. Here, we examine the importance of the IOP and rate of formation of aqueous humour in the development of vertebrate eyes by performing allometric and scaling analyses of the forces acting on the eye during head movement and the energy demands of the cornea, and testing the predictions of the models against a list of measurements in vertebrates collated through a systematic review. We show that the IOP has a weak dependence on body mass, and that in order to maintain the focal length of the eye, it needs to be an order of magnitude greater than the pressure drop across the eye resulting from gravity or head movement. This constitutes an evolutionary constraint that is common to all vertebrates. In animals with cornea-based optics, this constraint also represents a condition to maintain visual acuity. Estimated IOPs were found to increase with the evolution of terrestrial animals. The rate of formation of aqueous humour was found to be adjusted to the metabolic requirements of the cornea, scaling as Vac(0.67), where Vac is the volume of the anterior chamber. The present work highlights an interdependence between IOP and aqueous flow rate crucial to ocular function that must be considered to understand the evolution of the dioptric apparatus. It should also be taken into consideration in the prevention and treatment of glaucoma.
    Matched MeSH terms: Intraocular Pressure/physiology*
  2. Zhao D, Kim MH, Pastor-Barriuso R, Chang Y, Ryu S, Zhang Y, et al.
    PLoS One, 2016;11(1):e0146057.
    PMID: 26731527 DOI: 10.1371/journal.pone.0146057
    IMPORTANCE: Intraocular pressure (IOP) reduction or stabilization is the only proven method for glaucoma management. Identifying risk factors for IOP is crucial to understand the pathophysiology of glaucoma.

    OBJECTIVE: To examine the associations of change in body mass index (BMI), waist circumference, and percent fat mass with change in intraocular pressure (IOP) in a large sample of Korean adults.

    DESIGN, SETTING AND PARTICIPANTS: Cohort study of 274,064 young and middle age Korean adults with normal fundoscopic findings who attended annual or biennial health exams from January 1, 2002 to Feb 28, 2010 (577,981 screening visits).

    EXPOSURES: BMI, waist circumference, and percent fat mass.

    MAIN OUTCOME MEASURE(S): At each visit, IOP was measured in both eyes with automated noncontact tonometers.

    RESULTS: In multivariable-adjusted models, the average increase in IOP (95% confidence intervals) over time per interquartile increase in BMI (1.26 kg/m2), waist circumference (6.20 cm), and percent fat mass (3.40%) were 0.18 mmHg (0.17 to 0.19), 0.27 mmHg (0.26 to 0.29), and 0.10 mmHg (0.09 to 0.11), respectively (all P < 0.001). The association was stronger in men compared to women (P < 0.001) and it was only slightly attenuated after including diabetes and hypertension as potential mediators in the model.

    CONCLUSIONS AND RELEVANCE: Increases in adiposity were significantly associated with an increase in IOP in a large cohort of Korean adults attending health screening visits, an association that was stronger for central obesity. Further research is needed to understand better the underlying mechanisms of this association, and to establish the role of weight gain in increasing IOP and the risk of glaucoma and its complications.

    Matched MeSH terms: Intraocular Pressure*
  3. Zhao D, Kim MH, Pastor-Barriuso R, Chang Y, Ryu S, Zhang Y, et al.
    Invest Ophthalmol Vis Sci, 2014 Oct;55(10):6244-50.
    PMID: 25183763 DOI: 10.1167/iovs.14-14151
    To examine the longitudinal association between age and intraocular pressure (IOP) in a large sample of Korean men and women.
    Matched MeSH terms: Intraocular Pressure/physiology*
  4. Yulia DE, Tan S
    Med J Malaysia, 2024 Mar;79(2):206-211.
    PMID: 38553928
    INTRODUCTION: Numerous tonometers are available to measure intraocular pressure (IOP) in children with glaucoma. This review aims to discuss IOP measurement techniques and principles and compare the accuracy, tolerability and ease of use of available tonometers in measuring IOP in paediatric glaucoma patients.

    MATERIALS AND METHODS: A review of observational studies was conducted to discuss the accuracy, tolerability and ease of use of tonometers in measuring IOP in children with glaucoma.

    RESULTS: Goldmann applanation tonometry (GAT) and its portable handheld versions remain the gold standard in measuring IOP. Tono-Pen (Reichert Ophthalmic Instruments, Depew, New York, USA) and rebound tonometer (RBT) both correlate well with GAT. Although both tonometers tend to overestimate IOP, Tono-Pen overestimates more than RBT. Overestimation is more remarkable in higher IOP and corneal pathologies (such as but not limited to scarred cornea and denser corneal opacity). RBT was better tolerated than other tonometers in children and was easier to use in children of all ages.

    CONCLUSIONS: RBT is the preferred tonometer for measuring IOP in children with glaucoma, as it is less traumatic, time efficient and does not require fluorescein dye or anaesthesia. However, examiners should use a second tonometer to confirm elevated IOP readings from the RBT.

    Matched MeSH terms: Intraocular Pressure*
  5. Yip VCH, Wong HT, Yong VKY, Lim BA, Hee OK, Cheng J, et al.
    J Glaucoma, 2019 07;28(7):e132-e133.
    PMID: 31135585 DOI: 10.1097/IJG.0000000000001289
    Matched MeSH terms: Intraocular Pressure
  6. Yip VCH, Wong HT, Yong VKY, Lim BA, Hee OK, Cheng J, et al.
    J Glaucoma, 2019 01;28(1):80-87.
    PMID: 30461553 DOI: 10.1097/IJG.0000000000001125
    AIM: To study the microvascular density of the macular and optic nerve head in healthy and glaucoma subjects using optical coherence tomography angiography.

    METHODOLOGY: We performed a cross-sectional cohort study on healthy subjects and patients with glaucoma. The AngioVue Enhanced Microvascular Imaging System was used to capture the optic nerve head and macula images during one visit. En face segment images of the macular and optic disc were studied in layers. Microvascular density of the optic nerve head and macula were quantified by the number of pixels measured by a novel in-house developed software. Areas under the receiver operating characteristic curves (AUROC) were used to determine the accuracy of differentiating between glaucoma and healthy subjects.

    RESULTS: A total of 24 (32 eyes) glaucoma subjects (57.5±9.5-y old) and 29 (58 eyes) age-matched controls (51.17±13.5-y old) were recruited. Optic disc and macula scans were performed showing a greater mean vessel density (VD) in healthy compared with glaucoma subjects. The control group had higher VD than the glaucoma group at the en face segmented layers of the optic disc (optic nerve head: 0.209±0.05 vs. 0.110±0.048, P<0.001; vitreoretinal interface: 0.086±0.045 vs. 0.052±0.034, P=0.001; radial peripapillary capillary: 0.146±0.040 vs. 0.053±0.036, P<0.001; and choroid: 0.228±0.074 vs. 0.165±0.062, P<0.001). Similarly, the VD at the macula was also greater in controls than glaucoma patients (superficial retina capillary plexus: 0.115±0.016 vs. 0.088±0.027, P<0.001; deep retina capillary plexus: 0.233±0.027 vs. 0.136±0.073, P<0.001; outer retinal capillary plexus: 0.190±0.057 vs. 0.136±0.105, P=0.036; and choriocapillaris: 0.225±0.053 vs. 0.153±0.068, P<0.001. The AUROC was highest for optic disc radial peripapillary capillary (0.96), followed by nerve head (0.92) and optic disc choroid (0.76). At the macula, the AUROC was highest for deep retina (0.86), followed by choroid (0.84), superficial retina (0.81), and outer retina (0.72).

    CONCLUSIONS: Microvascular density of the optic disc and macula in glaucoma patients was reduced compared with healthy controls. VD of both optic disc and macula had a high diagnostic ability in differentiating healthy and glaucoma eyes.

    Matched MeSH terms: Intraocular Pressure/physiology
  7. Wong EY, Chew PT, Chee CK, Wong JS
    Am J Ophthalmol, 1997 Dec;124(6):797-804.
    PMID: 9402826
    PURPOSE: To evaluate the effectiveness and safety of diode laser contact transscleral cyclophotocoagulation in Asian patients with refractory glaucoma by lower energy settings with an innovative probe featuring a glass ball tip that focused the laser beam onto the ciliary body.

    METHODS: This prospective clinical study included consecutive Asian patients with dark irides and confirmed for glaucoma. Only one eye of each patient was treated. Diode laser contact transscleral cyclophotocoagulation treatment was performed with the center of the probe placed 1.5 mm behind the limbus. About 30 pulses of 810-mm laser radiation (power, 1.8 to 2.0 W; duration, 0.3 to 0.5 second) were applied around the eye. Patients were examined at fixed postoperative intervals. Intraocular pressure levels and postoperative complications were recorded. The relation between patient and disease characteristics, total laser energy delivered, and intraocular pressure effects were analyzed.

    RESULTS: Thirty-three patients were studied, with a mean follow-up period of 9.4 months. An average 56% of patients showed a 30% or greater drop in intraocular pressure. About 38% of patients achieved sustained intraocular pressure lowering to below 22 mm Hg at 18 months. Complications were few and included transient hypotony and iritis.

    CONCLUSIONS: In Asian patients with refractory glaucoma or painful glaucomatous eyes with poor visual acuity (defined for this study as worse than 20/200), low-energy-setting diode laser contact transscleral cyclophotocoagulation by means of the glass ball probe is relatively effective and safe.

    Matched MeSH terms: Intraocular Pressure/physiology
  8. Vassiliev P, Iezhitsa I, Agarwal R, Marcus AJ, Spasov A, Zhukovskaya O, et al.
    Data Brief, 2018 Jun;18:340-347.
    PMID: 29896521 DOI: 10.1016/j.dib.2018.02.067
    This article contains data that relate to the study carried out in the work of Marcus et al. (2018) [1]. Data represent an information about pharmacophore analysis of imidazo[1,2-a]benzimidazole and pyrimido[1,2-a]benzimidazole derivatives and results of construction of the relationship between intraocular pressure (IOP) lowering activity and hypotensive activity of imidazo[1,2-a]benzimidazole and pyrimido[1,2-a]benzimidazole derivatives using a multilayer perceptron artificial neural network. In particular, they include the ones listed in this article: 1) table of all pharmacophores of imidazo[1,2-a]benzimidazole and pyrimido[1,2-a]benzimidazole derivatives that showed IOP lowering activity; 2) table of all pharmacophores of the compounds that showed absence of IOP lowering activity; 3) table of initial data for artificial neural network analysis of relationship between IOP activity and hypotensive activity of this chemical series; 4) graphical representation of the best neural network model of this dependence; 5) original txt-file of results of pharmacophore analysis; 6) xls-file of initial data for neural network modeling; 7) original stw-file of results of neural network modeling; 8) original xml-file of the best neural network model of dependence between IOP lowering activity and hypotensive activity of these azole derivatives. The data may be useful for researchers interested in designing new drug substances and will contribute to understanding of the mechanisms of IOP lowering activity.
    Matched MeSH terms: Intraocular Pressure
  9. Ting Yl J, Faisal HA, Pan SW
    Int Ophthalmol, 2019 Jan;39(1):203-206.
    PMID: 29197945 DOI: 10.1007/s10792-017-0774-1
    PURPOSE: To describe a rare case of spontaneous expulsive suprachoroidal haemorrhage (SESCH) in an asymptomatic elderly patient.

    METHOD: This is a case report of a 76-year-old Chinese female, presented as an emergency with spontaneous left eye bleeding. She had underlying uncontrolled hypertension, no other systemic illness and not on anticoagulant. She has a history of right eye cataract operation, right eye angle-closure glaucoma and left eye absolute glaucoma complicated with painless left blind eye. Ocular examination over left eye showed no light perception and demonstrated presence of fresh bleed, expulsion of lens and prolapsed uveal contents, while right eye examination was unremarkable. Patient subsequently underwent evisceration and was uneventful.

    RESULTS: Routine blood investigations including coagulation profile came back as normal. Surgical findings include perforated cornea more than three-fourths with prolapsed uveal contents and fragile conjunctiva. No other significant macroscopic conditions were noted. Histology and culture came back with growth of Pseudomonas aeuroginosa with no evidence of malignancy.

    DISCUSSION: SESCH is a rare but serious sight-threatening ocular condition associated with multiple risk factors including arteriosclerosis, vascular disease, glaucoma, diabetes, intraocular malignancy and diseased eye wall. The predisposing factors involved in this case include advanced age, glaucoma with persistent high intraocular pressure, uncontrolled hypertension and presence of infection.

    Matched MeSH terms: Intraocular Pressure
  10. Ting SL, Lim LT, Ooi CY, Rahman MM
    Asia Pac J Ophthalmol (Phila), 2019;8(3):229-232.
    PMID: 31165604 DOI: 10.22608/APO.2018433
    PURPOSE: To compare the measurement of intraocular pressure (IOP) of Icare rebound tonometer and Perkins applanation tonometer (PAT) during community eye screening and to assess the agreement between these 2 instruments.

    DESIGN: A cross-sectional, non-interventional study.

    METHODS: The IOP measurements by handheld Icare rebound tonometer (Finland) were first performed by a primary care physician. Then the IOP was measured using Perkins Mk3 applanation tonometer (Haag-Streit, UK) by an ophthalmologist who was masked to previous readings from the Icare rebound tonometer. The mean IOP measured by each tonometer was compared. Pearson correlation coefficient was used to explore the correlation between the IOP measurements of the 2 instruments. The level of agreement between them was assessed using the Bland and Altman method.

    RESULTS: A total of 420 left eyes were examined. The mean age of subjects was 38.6 ± 18.2 years. Approximately 67% of subjects were female. The mean IOP was 16.3 ± 4.0 mm Hg using Icare and 13.4 ± 2.3 mm Hg using PAT. Pearson correlation coefficient showed a moderate positive correlation between the 2 methods (r = +0.524, P < 0.001). Linear regression analysis revealed a slope of 0.28 with R² of 0.255. The mean difference between the 2 methods was 2.90 ± 3.5 mm Hg and the sample t-test revealed a statistically significant mean difference from 0 (P < 0.001). The 95% limits of agreement between the 2 methods were between -9.73 and 3.93 mm Hg.

    CONCLUSIONS: The handheld Icare rebound tonometer is a reasonably acceptable screening tool in community practices. However, Icare overestimated IOP with a mean of 2.90 mm Hg higher than the PAT. Thus, using Goldmann applanation tonometer as a confirmatory measurement tool of IOP is suggested.

    Matched MeSH terms: Intraocular Pressure/physiology*
  11. Tharmathurai S, Muhammad-Ikmal MK, Razak AA, Che-Hamzah J, Azhany Y, Fazilawati Q, et al.
    J Glaucoma, 2021 May 01;30(5):e205-e212.
    PMID: 33710066 DOI: 10.1097/IJG.0000000000001830
    PRCIS: Depression increases with severity of visual field defect in older adults with primary open-angle glaucoma (POAG).

    PURPOSE: This study aimed to determine the prevalence of depression among patients with POAG and examine the relationship between depression and the severity of POAG in older adults.

    MATERIALS AND METHODS: Three hundred and sixty patients with POAG aged 60 years or above were recruited from 2 tertiary centers located in an urban and suburban area. The participants were stratified according to the severity of their glaucoma based on the scores from the modified Advanced Glaucoma Intervention Study (AGIS) to mild, moderate, severe, and end stage. Face-to-face interviews were performed using the Malay Version Geriatric Depression Scale 14 (mGDS-14) questionnaire. Depression is diagnosed when the score is ≥8. One-way analysis of variance was used to compare the subscores between the groups. Multifactorial analysis of variance was also applied with relevant confounding factors.

    RESULTS: Depression was detected in 16% of older adults with POAG; a higher percentage of depression was seen in those with end stage disease. There was a significant increase in the mean score of mGDS-14 according to the severity of POAG. There was evidence of an association between depression and severity of visual field defect (P<0.001). There was a significant difference in mGDS-14 score between the pairing of severity of POAG [mild-severe (P=0.003), mild-end stage (P<0.001), moderate-severe (P<0.001), and moderate-end stage (P<0.001)] after adjustment to living conditions, systemic disease, and visual acuity.

    CONCLUSION: Ophthalmologists should be aware that older adults with advanced visual field defects in POAG may have depression. The detection of depression is important to ensure adherence and persistence to the treatment of glaucoma.

    Matched MeSH terms: Intraocular Pressure
  12. Teoh LO, Ishikawa H, Liebmann JM, Ritch R
    Arch. Ophthalmol., 2000 Jul;118(7):989-90.
    PMID: 10900117
    Matched MeSH terms: Intraocular Pressure
  13. Tan SY, Md Din N, Mohd Khialdin S, Wan Abdul Halim WH, Tang SF
    Cureus, 2021 Feb 12;13(2):e13320.
    PMID: 33738163 DOI: 10.7759/cureus.13320
    The hazy corneal donor-recipient interface after corneal transplant may cause difficulties when implanting the XEN gel stent via ab-interno approach. We aim to describe XEN gel stent implantation via ab-externo approach in refractory steroid-induced glaucoma after corneal lamellar keratoplasty. Under local anaesthesia, the XEN injector needle was inserted 7 mm behind the limbus with the bevel facing up, directly beneath the conjunctiva and advanced to the marked 2.5 mm scleral entry wound. The needle then pierced the sclera until the needle tip was just visible in the anterior chamber (AC). The slider was pushed until the tip of the XEN stent was seen in the AC. The needle was slowly withdrawn while still pushing the slider to complete stent deployment. Subconjunctival Mitomycin C 0.01% (30 µg/0.3 mL) was then injected posterior to the bleb. Three eyes of three patients with steroid-induced glaucoma after lamellar keratoplasty underwent XEN gel stent implantation via ab-externo approach placed at the superotemporal quadrant. Pre-operatively, all patients had uncontrolled IOP between 30-45 mmHg despite maximum medications and selective laser trabeculoplasty. After XEN gel stent implantation, IOP ranged between 10-17 mmHg with one or two topical antiglaucoma at 12 months. Complications include hypotony maculopathy, stent migration and hyphaema, all of which were successfully managed. Corneal graft remained clear at 12 months. XEN gel stent implantation via ab-externo approach is able to achieve good intraocular pressure (IOP) control without compromising cornea graft in patients with steroid-induced glaucoma after lamellar keratoplasty at 12 months.
    Matched MeSH terms: Intraocular Pressure
  14. Tan HK, Ahmad Tajuddin LS, Lee MY, Ismail S, Wan-Hitam WH
    PMID: 26065503 DOI: 10.1097/APO.0000000000000058
    PURPOSE: To determine the mean central corneal thickness (CCT) and the relationship between the CCT and visual field progression in primary angle closure (PAC) and primary angle closure glaucoma (PACG).

    DESIGN: A combined cross-sectional and prospective study on PAC and PACG.

    METHODS: A total of 35 eyes were included in the study for each group of normal control, PAC, and PACG patients from eye clinics in Kota Bharu, state of Kelantan, Malaysia, from January 2007 to November 2009. The PAC and PACG patients were divided into thin and thick CCT groups. They were followed up for 12 to 18 months for visual field progression assessment with their mean Advanced Glaucoma Intervention Study (AGIS) score.

    RESULTS: The CCT was 516.8 ± 26.0 µm for PAC and 509.7 ± 27.4 µm for PACG. Both were significantly thinner compared with the control group with CCT of 540 ± 27.8 µm (P < 0.001). There was a statistically significant increase in the mean AGIS score after 12.9 ± 1.7 months of follow-up in the thin CCT group for PACG (P = 0.002). However, no significant increase in the mean AGIS score was found for the thick CCT group in PACG and for both thin and thick CCT in PAC.

    CONCLUSIONS: The PAC and PACG had statistically significant thinner CCT compared with the controls. Thin CCT was associated with visual field progression based on the mean AGIS score in PACG.

    Matched MeSH terms: Intraocular Pressure*
  15. Tan AK, Azman A, Hoe TS, Rohana T
    Med J Malaysia, 1994 Dec;49(4):409-11.
    PMID: 7674978
    A six-year-old boy, a known case of acute lymphoblastic leukaemia (ALL) on remission since 1991 presented with leukocoria and poor vision of the left eye for two days' duration. Examination revealed endophthalmitis in the left eye with raised intraocular pressure. Anterior chamber paracentesis with vitreous biopsy confirmed a diagnosis of ocular involvement. Further investigation revealed that he also had bone marrow and central nervous system relapse. Clinical manifestation and treatment modalities of ocular involvement in leukaemia are discussed.
    Matched MeSH terms: Intraocular Pressure
  16. Tajunisah I, Reddy SC, Fathilah J
    Graefes Arch Clin Exp Ophthalmol, 2007 Dec;245(12):1851-7.
    PMID: 17901971
    BACKGROUND: A case-controlled prospective study was conducted to evaluate the diurnal variation of intraocular pressure (IOP); the mean, the amplitude of variation and the peak and trough times of pressure readings in the suspected open-angle glaucoma patients as compared with a control group. We also looked at the outcome of these suspects after diurnal variation of IOP measurements.

    METHODS: Diurnal variation of intraocular pressure was measured in 202 eyes of suspected open-angle glaucoma patients and 100 control eyes, at 4-hourly intervals for 24 hours (phasing). Based on the phasing results, optic disc changes and visual field defects, the patients were diagnosed as primary open angle glaucoma (POAG), normal tension glaucoma (NTG), ocular hypertension (OHT), or physiologic cup (PC), or still remained as glaucoma suspects due to inconclusive diagnosis. The last group (glaucoma suspects) was then followed up 6-monthly for their eventual outcome.

    RESULTS: The highest percentage of suspected glaucoma patients had peak (maximum) readings in the mid-morning (10-11 A.M.) and trough (minimum) readings after midnight (2-3 A.M.); the highest percentage of control group had peak readings in the late evening (6-7 P.M.) and trough readings after midnight (2-3 A.M.). The mean amplitude of variance was 6 mm Hg in suspected glaucoma group and 4 mm Hg in the control group. After 'phasing', 18.8% of the suspected glaucoma patients were diagnosed as POAG, 16.8% as NTG, 5% as OHT, and 28.7% as physiologic cup; 30.9% remained as glaucoma suspects. After 4 years follow-up, 70% of the glaucoma suspects still remained as glaucoma suspects, 6.7% developed NTG and another 6.7% POAG; 16.6% were normal.

    CONCLUSIONS: Serial measurement of IOP ( phasing) in a 24-hour period is still needed, in order not to miss the peak and the trough IOP readings in suspected open-angle glaucoma patients, which helps in better management of glaucoma. Among 30.9% of patients who remained as glaucoma suspects after the initial phasing, 13.4% developed NTG/POAG over a period of 4 years.

    Matched MeSH terms: Intraocular Pressure/physiology*
  17. Sumasri K, Raju P, Aung T, Tin A, Wong TY
    Am J Ophthalmol, 2008 Apr;145(4):766-7; author reply 767.
    PMID: 18358854 DOI: 10.1016/j.ajo.2007.12.028
    Matched MeSH terms: Intraocular Pressure
  18. Subramaniam S, Jeoung JW, Lee WJ, Kim YK, Park KH
    Jpn. J. Ophthalmol., 2018 Nov;62(6):634-642.
    PMID: 30229404 DOI: 10.1007/s10384-018-0620-7
    PURPOSE: To compare the diagnostic capability of three-dimensional (3D) neuro-retinal rim thickness (NRR) with existing optic nerve head and retinal nerve fiber layer (RNFL) scan parameters using high-definition optical coherence tomography (HD-OCT).

    DESIGN: Retrospective study.

    METHODS: Based on the mean deviation (MD) of the Humphrey Field Analyzer (HFA), the 152 subjects were categorized into mild (MD > - 6 dB, 100), moderate (MD - 6 to - 12 dB, 26), and severe (MD

    Matched MeSH terms: Intraocular Pressure*
  19. Singh M, Kaur B
    Int Ophthalmol, 1992 May;16(3):163-6.
    PMID: 1452420
    Postural behaviour of intraocular pressure (IOP) was studied in 29 glaucomatous eyes before and after argon laser trabeculoplasty (ALT) and compared with that of 60 normal eyes. Although argon laser trabeculoplasty was successful in lowering the IOP below 21 mm Hg, it produced little effect on the postural behaviour of the IOP. No significant change was observed in the amplitude of postural rise of IOP in ALT treated eyes.
    Matched MeSH terms: Intraocular Pressure/physiology*
  20. Singh M, Chin SSH
    Med J Malaysia, 1986 Mar;41(1):38-43.
    PMID: 3796346
    Raised intraocular pressure (lOP) is generally held responsible for causing visual loss in chronic simple glaucoma. It is therefore desirable that a safe level of lOP be maintained all the time. Elevation of lOP with change of body position has been suggested as one of the factors which result in tissue damage in low tension as well as in primary wide open angle glaucoma. Postural behaviour of lOP was therefore studied in 58 normal and 30 glaucomatous Malaysian eyes. Clinical significance and possible pathogenesis of abnormal postural response of lOP has been discussed. More application of this simple procedure is advocated.
    Matched MeSH terms: Intraocular Pressure*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links