Displaying publications 1 - 20 of 31 in total

Abstract:
Sort:
  1. Zainudin BM
    Med J Malaysia, 1993 Sep;48(3):259-68.
    PMID: 8183136
    Delivering a drug direct to the site of disease has several advantages. In the case of aerosols, it only requires about one-twentieth of the oral dose of the drug to exert its effect, thus resulting in less or minimal systemic side-effects. The onset of action is fast and the efficacy is superior to the oral drug. Because of the anatomy of the airways which are protective against the inhalation of foreign substances, the aerosol particles must be inhaled in an optimal way in order to reach the sites of action which are the peripheral airways. The particle size must be small and the aerosol must be inhaled in a coordinated manner, especially when a pressurised metered dose inhaler is used. Because of the high pressure of the propellants used in the canister, the particles will travel at a rapid speed upon actuating, causing great impaction in the throat. Only a small percentage reaches the peripheral airways and this percentage is even smaller if the coordination between actuation and inhalation is poor. Spacers have been shown to be able to overcome this problem of incoordination and to reduce throat impaction. Alternatively, the breath-actuated dry powder inhaler can be effectively used. The nebuliser, which is another aerosol delivery system, needs proper setting of the flow rate of compressed air and an appropriate volume of solution in order to optimise the drug delivery.
    Matched MeSH terms: Nebulizers and Vaporizers
  2. Zainudin BM, Ismail O, Yusoff K
    Thorax, 1994 Mar;49(3):267-9.
    PMID: 8202885
    BACKGROUND: The benefit of adding theophylline to beta 2 agonists in acute asthmatic attacks has been debated frequently.
    METHODS: In an open randomised study 25 patients with severe acute asthma who presented to the emergency department were treated with either a combined nebulised salbutamol (5 mg/dose) and aminophylline infusion (0.6-0.9 mg/kg/hour), or nebulised salbutamol alone.
    RESULTS: The responses to treatment as measured by peak expiratory flow (PEF) and the time taken to achieve maximum PEF were similar in both groups. Side effects were observed more commonly in patients receiving the combined treatment.
    CONCLUSIONS: Nebulised salbutamol is equally efficacious in acute asthma when given alone or in combination with aminophylline.
    Study site: Emergency department, Hospital Kuala Lumpur, Malaysia
    Matched MeSH terms: Nebulizers and Vaporizers
  3. Kardia E, Halim NSSA, Yahaya BH
    Methods Mol Biol, 2016;1516:243-255.
    PMID: 27062596 DOI: 10.1007/7651_2016_327
    Aerosol-based cell delivery technique via intratracheal is an effective route for delivering transplant cells directly into the lungs. An aerosol device known as the MicroSprayer(®) Aerosolizer is invented to transform liquid into an aerosol form, which then can be applied via intratracheal administration for drug delivery. The device produces a uniform and concentrated distribution of aerosolized liquid. Using the capability of MicroSprayer(®) Aerosolizer to transform liquid into aerosol form, our group has designed a novel method of cell delivery using an aerosol-based technique. We have successfully delivered skin-derived fibroblast cells and airway epithelial cells into the airway of a rabbit with minimum risk of cell loss and have uniformly distributed the cells into the airway. This chapter illustrates the application of aerosol device to deliver any type of cells for future treatment of lung diseases.
    Matched MeSH terms: Nebulizers and Vaporizers
  4. Liam CK, Lim KH, Wong CM
    Asian Pac J Allergy Immunol, 2000 Sep;18(3):135-40.
    PMID: 11270467
    This study aimed to evaluate dry powder inhaler naive asthmatic patients' perception and preference of the Accuhaler, a multidose dry powder inhaler and the pressurized metered dose inhaler (pMDI). After the first instruction, 66.7% of 48 patients enrolled in the study could demonstrate the correct use of the Accuhaler. When the patients were asked to compare the pMDI and the Accuhaler after using the Accuhaler to administer salmeterol for 4 weeks, the Accuhaler scored significantly better than the pMDI for the following features: knowing how many doses are left, presence of an attached cover, taste, instruction for use, attractiveness, ease of use, ease of holding, shape, and comfortable mouthpiece. The pMDI scored better to the Accuhaler in terms of size. More patients preferred the Accuhaler than the pMDI; the presence of a dose counter and perceived ease of use were the main reasons cited for their preference for the Accuhaler.
    Study site: Asthma Clinic, University of Malaya Medical Centre (UMMC), Kuala Lumpur, Malaysia
    Matched MeSH terms: Nebulizers and Vaporizers*
  5. Watts G
    Lancet, 2016 Sep 24;388(10051):1274.
    PMID: 27673462 DOI: 10.1016/S0140-6736(16)31669-5
    Matched MeSH terms: Nebulizers and Vaporizers/history*
  6. Muneswarao J, Hassali MA, Ibrahim B, Saini B, Naqvi AA, Hyder Ali IA, et al.
    J Asthma, 2021 09;58(9):1229-1236.
    PMID: 32493083 DOI: 10.1080/02770903.2020.1776728
    OBJECTIVE: The Test of Adherence to Inhalers (TAI) is a validated self-reported questionnaire that can reliably assess adherence to inhalers through patient self-report. However, it was not available in Bahasa Melayu (BM) language, nor has it been validated for use in the Malaysian population. The study aimed, therefore, to translate the 10-item TAI questionnaire into BM and evaluate its psychometric properties.

    METHODS: The translation of the English version of the valid 10-item TAI questionnaire into BM was followed by subjecting it to a series of tests establishing factorial, concurrent and known group validities. Concurrent validity was assessed through Spearman's rank correlation coefficient against pharmacy refill-based adherence scores. Known group validity was assessed by cross-tabulation against asthma symptom control and using chi-square test. The internal consistency of the test scale was determined by a test-retest method using Cronbach's alpha (α) value and intraclass correlation coefficients.

    RESULTS: A total of 120 adult asthma patients participated in the study. A 2-factor structure was obtained and confirmed with acceptable fit indices; CFI, NFI, IFI, TLI >0.9 and, RMSEA was 0.08. The reliability of the scale was 0.871. The test-retest reliability coefficient for the total sum score was 0.832 (p 85%.

    CONCLUSIONS: The scale successfully translated into BM and validated. The 10-item TAI-BM appears fit for use in testing inhaler adherence of Malaysian patients with asthma.

    Matched MeSH terms: Nebulizers and Vaporizers*
  7. Loh LC, Teh PN, Raman S, Vijayasingham P, Thayaparan T
    Malays J Med Sci, 2005 Jan;12(1):39-50.
    PMID: 22605946 MyJurnal
    Perceived breathlessness played an important role in guiding treatment in asthma. We developed a simple, user-friendly method of scoring perception of dyspnoea (POD) using an incentive spirometer, Triflo II (Tyco Healthcare, Mansfield, USA) by means of repetitive inspiratory efforts achieved within three minutes in 175 normal healthy subjects and 158 asthmatic patients of mild (n=26), moderate (n=78) and severe (n=54). Severity was stratified according to GINA guideline. The mean POD index in normal subjects, and asthmatic patients of mild, moderate and severe severity were: 6 (4-7) 16 (9-23), 25 (14-37), and 57 (14-100) respectively (p<0.001 One-Way ANOVA). Based on 17 asthmatic and 20 normal healthy subjects, intraclass correlation coefficients for POD index within subjects were high. In 14 asthmatic patients randomized to receiving nebulised b(2)-agonist or saline in a crossover, double-blind study, % FEV(1) change correlated with % changes in POD index [r(s) -0.46, p=0.012]. Finally, when compared with 6-minutes walking test (6MWT) in an open label study, respiratory POD index correlated with walking POD index in 21 asthmatic patients [r(s)= 0.58 (0.17 to 0.81) (p=0.007] and 26 normal subjects [0.50 (0.13 to 0.75) (p=0.008)]. We concluded that this test is discriminative between asthmatic patients of varying severity and from normal subjects, is reproducible, responsive to bronchodilator effect, and comparable with 6MWT. Taken together, it has the potential to score disability and POD in asthma effectively and simply.
    Matched MeSH terms: Nebulizers and Vaporizers
  8. Sahib MN, Darwis Y, Peh KK, Abdulameer SA, Tan YT
    Int J Nanomedicine, 2011;6:2351-66.
    PMID: 22072872 DOI: 10.2147/IJN.S25363
    Inhaled corticosteroids provide unique systems for local treatment of asthma or chronic obstructive pulmonary disease. However, the use of poorly soluble drugs for nebulization has been inadequate, and many patients rely on large doses to achieve optimal control of their disease. Theoretically, nanotechnology with a sustained-release formulation may provide a favorable therapeutic index. The aim of this study was to determine the feasibility of using sterically stabilized phospholipid nanomicelles of budesonide for pulmonary delivery via nebulization.
    Matched MeSH terms: Nebulizers and Vaporizers
  9. Ang KM, Yeo LY, Hung YM, Tan MK
    Lab Chip, 2016 09 21;16(18):3503-14.
    PMID: 27502324 DOI: 10.1039/c6lc00780e
    The deposition of a thin graphene film atop a chip scale piezoelectric substrate on which surface acoustic waves are excited is observed to enhance its performance for fluid transport and manipulation considerably, which can be exploited to achieve further efficiency gains in these devices. Such gains can then enable complete integration and miniaturization for true portability for a variety of microfluidic applications across drug delivery, biosensing and point-of-care diagnostics, among others, where field-use, point-of-collection or point-of-care functionality is desired. In addition to a first demonstration of vibration-induced molecular transport in graphene films, we show that the coupling of the surface acoustic wave gives rise to antisymmetric Lamb waves in the film which enhance molecular diffusion and hence the flow through the interstitial layers that make up the film. Above a critical input power, the strong substrate vibration displacement can also force the molecules out of the graphene film to form a thin fluid layer, which subsequently destabilizes and breaks up to form a mist of micron dimension aerosol droplets. We provide physical insight into this coupling through a simple numerical model, verified through experiments, and show several-fold improvement in the rate of fluid transport through the film, and up to 55% enhancement in the rate of fluid atomization from the film using this simple method.
    Matched MeSH terms: Nebulizers and Vaporizers
  10. Zainudin BM, Sufarlan AW
    Med J Malaysia, 1990 Sep;45(3):235-8.
    PMID: 2152085
    The use of pressurised metered dose inhalers was assessed among 93 asthmatic patients attending the respiratory out patient clinic between January to October 1989. They were regular users of the inhalers prior to the assessment. 62.4% of the patients were found to use the inhalers incorrectly. Forty three percent made more than one error. The commonest error observed was the failure to actuate and inhale the aerosol together in 41.9%. There was no difference in the occurrence of incorrect performance between different sexes, age groups, duration of inhaler used and previous supervision or no supervision by the doctors.
    Study site: Respiratory clinic, Hospital Kuala Lumpur (UKM), Malaysia
    Matched MeSH terms: Nebulizers and Vaporizers*
  11. Güvenir M, Otlu B, Tunc E, Aktas E, Suer K
    Malays J Med Sci, 2018 Mar;25(2):40-49.
    PMID: 30918454 DOI: 10.21315/mjms2018.25.2.5
    Background: Stenotrophomonas maltophilia is a non-fermentative gram-negative bacillus which is widely recognised as an important nosocomial pathogen causing pneumonia, blood-stream, wound and urinary tract infections, particularly in immunosuppressed patients. The aim of this study was to evaluate a nosocomial outbreak of by S. maltophilia in an intensive care unit of a tertiary hospital and evaluate unexpected multiclonality.

    Methods: A total of 11 isolates from respiratory cultures in intensive care unit of a 24 bed tertiary hospital obtained over a one months period and one isolate obtained from the nebuliser during environmental screening were investigated. The bacteria were identified by Phoenix 100 system. The clonal relatedness was evaluated by PFGE and semi-automated repetitive sequence-based PCR. Genotyping tests were repeated for 10 serial subcultures.

    Results: PFGE and DiversiLab yielded 10 genotypic profiles for 12 isolates. Four to eight different genotypes were observed from 10 subcultures of the same isolate.

    Conclusion: We conclude that, high genetic diversity and supposed multiclonal appearance of the outbreak isolates may be due to changing profiles during subcultures most probably depending on hypermutation.

    Matched MeSH terms: Nebulizers and Vaporizers
  12. Mohd Rhazi NA, Muneswarao J, Abdul Aziz F, Ibrahim B, Kamalludin A, Soelar SA
    J Asthma, 2023 Aug;60(8):1608-1612.
    PMID: 36650693 DOI: 10.1080/02770903.2023.2169930
    INTRODUCTION: Anti-inflammatory reliever (AIR) with or without regular maintenance delivered through Turbuhaler® has been widely recommended in the GINA strategy document. These patients are not prescribed with additional reliever inhalers, but dependent on Turbuhaler® during acute asthma episodes. The peak inspiratory flow rate (PIFR) is crucial in drug delivery from a dry powder inhaler (DPI) such as Turbuhaler®. Despite its increasing usage, there are some concerns that patients on Turbuhaler® are not able to achieve adequate PIFR during acute exacerbation of asthma.

    OBJECTIVE: This study aimed to assess the PIFR at resistance settings that matched Turbuhaler® in patients with acute exacerbation of asthma.

    METHODOLOGY: A six-month cross-sectional study was conducted at the Emergency Department (ED) of Hospital Sultanah Bahiyah and Hospital Kulim, Kedah, Malaysia. Adult patients diagnosed with mild to moderate acute exacerbations of asthma were recruited. The PIFRs were measured using the In-Check DIAL G16 that was set to simulate the resistance of Turbuhaler® (R3). The PIFRs were assessed before (pre) and after (post) the initial bronchodilator (BD) treatment at the ED. The minimal required PIFR was defined as flow rates ≥ 30 L/min while a PIFR of 60 L/min was considered as optimal.

    RESULTS: A total of 151 patients (81 females and 70 males) were recruited. The mean age was 37.5 years old with a range between 18 and 79 years old. The results showed that 98% (n = 148) of patients managed to achieve the minimal PIFR required for pre-BD. The mean PIFR pre-BD was 60 ± 18.5 L/min and post-BD was 70 ± 18.5 L/min. Furthermore, more than half (54%, n = 82) of the patients recorded PIFR ≥ 60 L/min during pre-BD, and about three-quarters (71%, n = 92) achieved PIFR ≥ 60 L/min post-BD. The PIFR showed a moderate correlation with peak expiratory flow rate (PEFR) (r = 0.55, 95% CI: 0.43-0.65, p 

    Matched MeSH terms: Nebulizers and Vaporizers
  13. Sulaiman H, Abdul-Aziz MH, Roberts JA
    Semin Respir Crit Care Med, 2017 06;38(3):271-286.
    PMID: 28578552 DOI: 10.1055/s-0037-1602716
    Hospital-acquired pneumonia and ventilator-associated pneumonia continue to cause significant morbidity and mortality. With increasing rates of antimicrobial resistance, the importance of optimizing antibiotic treatment is key to maximize treatment outcomes. This is especially important in critically ill patients in intensive care units, in whom the infection is usually caused by less susceptible organisms. In addition, the marked physiological changes that can occur in these patients can cause serious changes in antibiotic pharmacokinetics which in turn alter the attainment of therapeutic drug exposures. This article reviews the various aspects of the pharmacokinetic changes that can occur in the critically ill patients, the barriers to achieving therapeutic drug exposures in pneumonia for systemically delivered antibiotics, the optimization for commonly used antibiotics in hospital- and ventilator-associated pneumonia, the agents that should be avoided in the treatment regimen, as well as the use of adjunctive therapy in the form of nebulized antibiotics.
    Matched MeSH terms: Nebulizers and Vaporizers
  14. Goh LC, Arvin B, Zulkiflee AB, Prepageran N
    Otolaryngol Head Neck Surg, 2018 10;159(4):783-788.
    PMID: 30126325 DOI: 10.1177/0194599818795852
    Objective To objectively compare the nasal decongestion potency of lidocaine/phenylephrine when delivered with a nasal nebulizer and a nasal spray before a rigid nasoendoscopic examination. Study Design Open-label randomized controlled trial. Setting Multicenter study. Methods This prospective clinical trial involved 106 participants with untreated chronic rhinitis. Fifty-three participants had 400 μL of lidocaine/phenylephrine administered into the right nostril with a nasal nebulizer, while the remaining 53 participants had 400 μL administered with a nasal spray. The control was the left nostril. Nasal resistance at 150-Pa fixed pressure was evaluated with an active anterior rhinomanometry at 5, 10, 15, and 30 minutes postintervention. Pain score was assessed subjectively by applying pressure to the inferior turbinate 30 minutes after intervention. Results There was an overall reduction in nasal resistance of the right nostril when lidocaine/phenylephrine was administered with the nasal nebulizer in comparison with the nasal spray. However, a statistically significant difference in nasal resistance was seen only at 5 minutes ( P = .047), 15 minutes ( P = .016), and 30 minutes ( P = .036). The examining endoscopist further supported the degree of nasal decongestion via subjective assessment of the nasal cavity ( P = .001). Pain scores obtained after the intervention showed a significant decrease in pain threshold when the nasal nebulizer was used instead of the nasal spray ( P = .040). Conclusions This study suggests that the delivery of lidocaine/phenylephrine to the nasal cavity by the nasal nebulizer provides better decongestive and analgesic potency as compared with the delivery by nasal sprays.
    Matched MeSH terms: Nebulizers and Vaporizers*
  15. Loo CY, Lee WH, Lauretani G, Scalia S, Cipolla D, Traini D, et al.
    Pharm Res, 2018 Feb 07;35(3):50.
    PMID: 29417313 DOI: 10.1007/s11095-018-2350-4
    PURPOSE: The failure of chronic therapy with antibiotics to clear persistent respiratory infection is the key morbidity and mortality factor for patients with chronic lung diseases, primarily due to the presence of biofilm in the lungs. It is hypothesised that carbon sources, such as mannitol, could stimulate the metabolic activity of persister cells within biofilms and restore their susceptibility to antibiotics. The aims of the current study are to: (1) establish a representative in vitro model of Pseudomonas aeruginosa biofilm lung infection, and (2) investigate the effects of nebulised mannitol on antibiotic efficacy, focusing on ciprofloxacin, in the eradication of biofilm.

    METHOD: Air interface biofilm was cultured onto Snapwell inserts incorporated into a modified pharmacopeia deposition apparatus, the Anderson Cascade Impactor (ACI). Three different formulations including mannitol only, ciprofloxacin only and combined ciprofloxacin and mannitol were nebulised onto the P. aeruginosa biofilm using the modified ACI. Antibacterial effectiveness was evaluated using colony-forming units counts, biofilm penetration and scanning electron microscopy.

    RESULTS: Nebulised mannitol promotes the dispersion of bacteria from the biofilm and demonstrated a synergistic enhancement of the antibacterial efficacy of ciprofloxacin compared to delivery of antibiotic alone.

    CONCLUSIONS: The combination of ciprofloxacin and mannitol may provide an important new strategy to improve antibiotic therapy for the treatment of chronic lung infections. Furthermore, the development of a representative lung model of bacterial biofilm could potentially be used as a platform for future new antimicrobial pre-clinical screening.

    Matched MeSH terms: Nebulizers and Vaporizers
  16. Loh LC, Kanabar V, D'Amato M, Barnes NC, O'Connor BJ
    Asian Pac J Allergy Immunol, 2005 Dec;23(4):189-96.
    PMID: 16572738
    Sputum induction with nebulized hypertonic saline is increasingly being used to evaluate airway inflammation. We investigated the procedure-associated risk in 16 asthmatics that were still symptomatic despite on high doses of regular corticosteroid (CS) therapy (7 on daily inhaled CS > or = 800 microg budesonide or equivalent; 9 on additional daily oral CS) and their sputum cellular profile. For comparison, 12 mild stable asthmatics and 10 normal healthy subjects were included. All subjects inhaled 3%, 4% and 5% hypertonic saline sequentially via ultrasonic nebulizer as a means to induce sputum. Maximal percentage fall of Forced Expiratory Volume on One Second (FEV1) during sputum induction was significantly greater in CS-dependent asthmatics (median % [IQR]: 16.0 [11.0-32.3]) than in mild asthmatics (5.3 [4.2-10.8], p = 0.002] and in normal subjects (4.6 [3.4-6.4]), p = 0.0001). The maximal percentage FEV1 fall was inversely correlated with baseline FEV1 (Rs= -0.69; p < 0.0001). Compared to mild asthmatics, induced sputum from CS-dependant asthmatics had proportionately fewer eosinophils (2.2 [0.8-7.0] versus 23.3% [10.7-46.3], p = 0.003) and greater neutrophils (64.2 [43.9-81.2] versus 28.7 [19.0-42.6], p = 0.009). Sputum neutrophils showed a significant inverse correlation to FEV1 (Rs = -0.51, p = 0.01). We concluded that sputum induction using nebulized hypertonic saline should be performed with caution in CS-dependant asthmatics. The airway cellular profile observed suggests that the immunopathology underlying CS-dependant asthmatics may be different or a consequence of CS therapy.
    Matched MeSH terms: Nebulizers and Vaporizers
  17. Price D, David-Wang A, Cho SH, Ho JC, Jeong JW, Liam CK, et al.
    J Asthma, 2016 09;53(7):761-9.
    PMID: 27096388 DOI: 10.3109/02770903.2016.1141951
    OBJECTIVE: We examined the physician perspectives on asthma management in Asia.

    METHODS: An online/face-to-face, questionnaire-based survey of respiratory specialists and primary care physicians from eight Asian countries/region was carried out. The survey explored asthma control, inhaler selection, technique and use; physician-patient communications and asthma education. Inclusion criteria were >50% of practice time spent on direct patient care; and treated >30 patients with asthma per month, of which >60% were aged >12 years.

    RESULTS: REALISE Asia (Phase 2) involved 375 physicians with average 15.9(±6.8) years of clinical experience. 89.1% of physicians reporting use of guidelines estimated that 53.2% of their patients have well-controlled (GINA-defined) asthma. Top consideration for inhaler choice was asthma severity (82.4%) and lowest, socio-economic status (32.5%). Then 54.7% of physicians checked their patients' inhaler techniques during consultations but 28.2(±19.1)% of patients were using their inhalers incorrectly; 21.1-57.9% of physicians could spot improper inhaler techniques in video demonstrations. And 79.6% of physicians believed combination inhalers could increase adherence because of convenience (53.7%), efficacy (52.7%) and usability (18.9%). Initial and follow-up consultations took 16.8(±8.4) and 9.2(±5.3) minutes, respectively. Most (85.1%) physicians used verbal conversations and least (24.5%), video demonstrations of inhaler use; 56.8% agreed that patient attitudes influenced their treatment approach.

    CONCLUSION: Physicians and patients have different views of 'well-controlled' asthma. Although physicians informed patients about asthma and inhaler usage, they overestimated actual usage and patients' knowledge was sub-optimal. Physician-patient interactions can be augmented with understanding of patient attitudes, visual aids and ancillary support to perform physical demonstrations to improve treatment outcomes.

    Matched MeSH terms: Nebulizers and Vaporizers*
  18. Azratul-Hizayu T, Chen CD, Lau KW, Azrizal-Wahid N, Tan TK, Lim YAL, et al.
    Parasitol Int, 2022 Feb;86:102483.
    PMID: 34678492 DOI: 10.1016/j.parint.2021.102483
    This study examines the biological efficacy of four mosquito mat vaporizers each containing different active ingredients: prallethrin with PBO, dimefluthrin, prallethrin, and d-allethrin. The glass chamber assay was used to evaluate their efficacy on Aedes albopictus (Skuse) (Diptera: Culicidae) from nine districts in Selangor, Malaysia. Aedes albopictus exhibited different knockdown rates, with 50% knockdown times, KT50, varying from 1.19 to 2.00 min, 1.22 to 2.20 min, 1.39 to 5.85 min, and 1.39 to 1.92 min for prallethrin with PBO, dimefluthrin, prallethrin and d-allethrin, respectively. In general, all populations of Ae. albopictus were completely knocked down after exposure to all active ingredients except Hulu Selangor population, which showed 96.00% knockdown against d-allethrin. On the contrary, mortality rates were observed from 84.00-100.00%, 84.00-100.00%, 90.67-100.00% and 90.67-100.00% in populations tested with prallethrin with PBO, dimefluthrin, prallethrin and d-allethrin, respectively. Moreover, significant correlations between mortality rates of prallethrin with PBO vs dimefluthrin (r = 0.836, P = 0.003), prallethrin with PBO vs prallethrin (r = 0.760, P = 0.011), and prallethrin vs d-allethrin (r = 0.694, P = 0.026) were also observed, suggesting cross-resistance among pyrethroids. d-allethrin was found to be high in insecticidal activity, followed by prallethrin, prallethrin with PBO, and dimefluthrin. In consistent with mortality due to insecticide exposure, elevated levels of enzyme activities were also demonstrated in Sabak Bernam, Hulu Selangor, Gombak, Petaling, Hulu Langat and Klang populations.
    Matched MeSH terms: Nebulizers and Vaporizers*
  19. Loh LC
    Family Physician, 2005;13(3):0-0.
    MyJurnal
    Significant changes have occurred in relation to how chronic asthma is being treated. Emphasis has now shifted from viewing asthma as a condition of smooth muscle dysfunction to one of chronic inflammation. As such, anti-inflammatory therapy forming the cornerstone of treatment represents the first important milestone in the evolution of asthma treatment. For this purpose, inhaled corticosteroid (ICS) is by far the most effective anti-inflammatory therapy. Another important milestone is the recognition of the superiority of adding long-acting β2-agonist (LABA) to ICS over escalating ICS dose alone or other forms of add-on therapies in treating asthmatic patients not responding to regular ICS alone. The effectiveness of adding LABA to ICS in treating asthma logically led to combining the two drugs into one single inhaler (salmeterol/fluticasone and budesonide/formoterol) that has the attractiveness of being user-friendly and ensuring that ICS is not missed out. The unique property of formoterol that allows for repetitive flexible dosing paved way to the concept of using Symbicort for both regular maintenance dosing and as required rescue medication. This revolutionary approach has been recently shown to provide improved asthma outcome, achieved at an overall lower or at least comparable corticosteroid intake, and may represent another evolutionary step in the treatment strategy of chronic asthma.
    Matched MeSH terms: Nebulizers and Vaporizers