OBJECTIVES: To assess the effectiveness of fibrin glue compared to sutures in conjunctival autografting for the surgical treatment of pterygium.
SEARCH METHODS: We searched CENTRAL (which contains the Cochrane Eyes and Vision Trials Register) (2016, Issue 9), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to October 2016), Embase (January 1980 to October 2016), the ISRCTN registry (www.isrctn.com/editAdvancedSearch), ClinicalTrials.gov (www.clinicaltrials.gov), and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 14 October 2016.
SELECTION CRITERIA: We included randomised controlled trials (RCTs) in any setting where fibrin glue was compared with sutures to treat people with pterygium.
DATA COLLECTION AND ANALYSIS: Two review authors independently screened the search results, assessed trial quality, and extracted data using standard methodological procedures expected by Cochrane. Our primary outcome was recurrence of pterygium defined as any re-growth of tissue from the area of excision across the limbus onto the cornea. The secondary outcomes were surgical time and complication rate. We graded the certainty of the evidence using GRADE.
MAIN RESULTS: We included 14 RCTs conducted in Brazil, China, Egypt, India, Malaysia, New Zealand, Philippines, Saudi Arabia, Sweden and Turkey. The trials were published between 2004 and 2016, and were assessed as a mixture of unclear and low risk of bias with three studies at high risk of attrition bias. Only adults were enrolled in these studies.Using fibrin glue for the conjunctival autograft may result in less recurrence of pterygium compared with using sutures (risk ratio (RR) 0.47, 95% CI 0.27 to 0.82, 762 eyes, 12 RCTs; low-certainty evidence). If pterygium recurs after approximately 10 in every 100 surgeries with sutures, then using fibrin glue may result in approximately 5 fewer cases of recurrence in every 100 surgeries (95% CI 2 fewer to 7 fewer cases). Using fibrin glue may lead to more complications compared with sutures (RR 1.92; 95% CI 1.22 to 3.02, 11 RCTs, 673 eyes, low-certainty evidence). The most common complications reported were: graft dehiscence, graft retraction and granuloma. On average using fibrin glue may mean that surgery is quicker compared with suturing (mean difference (MD) -17.01 minutes 95% CI -20.56 to -13.46), 9 RCTs, 614 eyes, low-certainty evidence).
AUTHORS' CONCLUSIONS: The meta-analyses, conducted on people with pterygium in a hospital or outpatient setting, show fibrin glue may result in less recurrence and may take less time than sutures for fixing the conjunctival graft in place during pterygium surgery. There was low-certainty evidence to suggest a higher proportion of complications in the fibrin glue group.
METHODS: 120 primary pterygium participants were selected from patients who visited an ophthalmology clinic. We adopted image analysis software in calculating the size of invading pterygium to the cornea. The marking of the calculated area was done manually, and the total area size was measured in pixel. The computed area is defined as the area from the apex of pterygium to the limbal-corneal border. Then, from the pixel, it was transformed into a percentage (%), which represents the CPTA relative to the entire corneal surface area. Intra- and inter-observer reliability testing were performed by repeating the tracing process twice with a different sequence of images at least one (1) month apart. Intraclass correlation (ICC) and scatter plot were used to describe the reliability of measurement.
RESULTS: The overall mean (N=120) of CPTA was 45.26±13.51% (CI: 42.38-48.36). Reliability for region of interest (ROI) demarcation of CPTA were excellent with intra and inter-agreement of 0.995 (95% CI, 0.994-0.998; P<0.001) and 0.994 (95% CI, 0.992-0.997; P<0.001) respectively. The new method was positively associated with corneal astigmatism (P<0.01). This method was able to predict 37% of the variance in CA compared to 21% using standard method.
CONCLUSIONS: Image analysis method is useful, reliable and practical in the clinical setting to objectively quantify actual pterygium size, shapes and its effects on the anterior corneal curvature.
DESIGN: A case-control study.
METHODS: This study received ethical approval (NMRR Research ID 23957) and informed consent was obtained from all participants. It involved 20 participants with 20 samples of pterygium and 20 samples of normal conjunctiva that were obtained from the same eye of each participant. All the participants underwent history taking, slit lamp examination, and pterygium excision surgery. Both samples underwent immunohistochemistry procedure. Pretreatment procedure was conducted using heat-induced epitope retrieval with PT link, subsequently followed by EnVision FLEX staining procedure and incubation with anti‒IL-17 antibody and anti‒IL-23 antibody. Slides were examined in high-power fields (400x) for both samples in 3 different fields. Total positive stained cell counts in all 3 fields with IL-17 and IL-23 between pterygium and normal conjunctiva were analyzed by using Wilcoxon signed rank test.
RESULTS: IL-17 positive cell counts for normal conjunctiva showed mean 196.10 ± 80.487 but for pterygium was 331.10 ± 108.416. As for IL-23, the mean for positive cell counts for normal conjunctiva was 62.10 ± 33.462 and IL-23 positive cell counts for pterygium showed mean 102.95 ± 41.378. Both IL-17 and IL-23 were significantly increased in pterygium compared with normal conjunctiva (P < 0.001).
CONCLUSIONS: Both IL-17 and IL-23 were found to be significantly higher in the pterygium group than in the normal conjunctiva group with P < 0.001 by Wilcoxon signed rank test.
METHODS: A prospective, randomized, single-blinded clinical trial to assess the efficacy of autologous blood in place of fibrin glue in pterygium surgery. A total of 120 eyes of 111 patients were randomized according to pterygium morphology, to undergo pterygium surgery with autografting using either autologous blood or fibrin glue. All patients were operated by a single surgeon; 58 eyes were operated using fibrin glue and 62 eyes had a conjunctival autograft with autologous blood. Patients were seen on postoperative day 1, 1 week, 1 month, 6 months, and 1 year after surgery. Graft stability and pterygium recurrence were graded by an independent observer who was masked to the method of treatment.
RESULTS: All 120 eyes completed the 1-year follow-up. Graft loss was seen only in the autologous blood group. Of the 62 eyes in this group, a total of 15 (24.2%) grafts dislodged. Recurrence was calculated after excluding grafts that were dislodged. Of the 105 patients, there were a total of 7 recurrences, 2 (3.4%) from the fibrin adhesive method and 5 (10.6%) from the autologous blood method. This was not statistically significant (P = 0.238).
CONCLUSIONS: Autologous blood does not exhibit similar graft stability seen with fibrin glue. Although the recurrence rate may not be significant, careful patient selection and a standard method needs to be laid out before the use of this method is widely accepted.
Methods: A cross-sectional study was conducted involving 114 Malay patients with POAG seen at the eye clinic of Hospital Universiti Sains Malaysia. Patients aged between 40 and 80 years who were diagnosed with other types of glaucoma, previous glaucoma filtering surgery or other surgeries except uncomplicated cataract surgery and pterygium surgery were excluded. A total of 101 patients who were followed up for dry eyes, age-related cataracts or post cataracts extraction surgery were recruited as control subjects. Those with family history of glaucoma or glaucoma suspect were excluded. Microvascular endothelial function was assessed using laser Doppler fluximetry and the process of iontophoresis. Iontophoresis with acetylcholine (ACh) and sodium nitroprusside (SNP) was used to measure microvascular endothelium-dependent and endothelium-independent vasodilatations, respectively.
Results: In general, POAG patients demonstrated lower ACh% and AChmax values compared with controls. There was significant difference in microvascular endothelial function [ACh%: mean, 95% confidence interval = 503.1 (378.0, 628.3), and AChmax: mean, 95% confidence interval = 36.8 (30.2, 43.5)] between primary open angle glaucoma cases (p