Displaying publications 1 - 20 of 39 in total

Abstract:
Sort:
  1. Ng ML, Sazali BS, Khalid BA
    Ann. Clin. Biochem., 1991 Nov;28 ( Pt 6):613-7.
    PMID: 1776812
    A filter method for collection and storage of capillary blood spots for glycated haemoglobin (gHb) has been developed. Glass fibre filters (GFB) impregnated with 0.8 M boric acid were used to collect and store capillary blood. Haemoglobin from the dried blood spots was eluted into water and determined by Drabkin's method, while gHb in the eluates was determined by the microcolorimetric method. The intraassay coefficients of variation (CVs) were 4.5, 4.5 and 3.1% at 882, 1101 and 1704 pmol HMF/mg Hb, respectively. The corresponding inter-assay CVs were 8.6, 8.6 and 6.3%, respectively. A total of 63 paired capillary and venous blood samples were measured by both the direct and GFB method. The GFB method showed excellent correlation with the direct method (r = 0.948 and r = 0.994) after 7 and 14 days' storage at room temperature. The GFB method will enable prior collection and postage of blood samples by patients.
    Matched MeSH terms: Specimen Handling/methods*
  2. Loh AG, Israf DA
    J Helminthol, 1998 Mar;72(1):39-42.
    PMID: 9639899
    The influence of soil texture (silt, sand and laterite) and flotation solutions (saturated NaCl, sucrose, NaNO3, and ZnSO4) upon the recovery of Toxocara ova from seeded soil samples with the centrifugal flotation technique was investigated. Soil samples of different texture were artificially seeded with Toxocara spp. ova and subjected to a centrifugal flotation technique which used various flotation solutions. The results showed significant (P < 0.001) interactions between the soil types and the flotation solutions. The highest percentage of ova recovery was obtained with silty soil (34.9-100.8%) with saturated NaCl as the flotation solution (45.3-100.8%). A combination of washing of soil samples with 0.1% Tween 80, and flotation using saturated NaCl and a 30 min coverslip recovery period was used to study the prevalence of contamination of soil samples. Forty-six soil samples were collected from up to 24 public parks/playgrounds in urban areas of Petaling Jaya and suburban areas of Serdang. The prevalence of Toxocara species in the urban and suburban areas was 54.5% and 45.8% respectively.
    Matched MeSH terms: Specimen Handling/methods
  3. Hayati AR, Khong TY, Zainul R
    Malays J Pathol, 1998 Dec;20(2):99-102.
    PMID: 10879270
    144 placentas were sampled from all cases of stillbirth weighing 500 g and above seen over a period of thirteen months in the UKM Unit of the Maternity Hospital, Kuala Lumpur. Sampling was limited to 1-3 blocks per placenta for histological study. Placental abnormalities were found in 121 (85%) placentas, 78 of which had definite lesions known to contribute to foetal death while the remainder showed lesions suggestive of an underlying disease. This study supports the usefulness of limited sampling of the placenta in the face of unavailability of complete placental examination and autopsy for assessment of the cause of stillbirth.
    Matched MeSH terms: Specimen Handling/methods*
  4. Tan EL, Peh SC, Sam CK
    J Med Virol, 2003 Feb;69(2):251-7.
    PMID: 12683415
    Nasopharyngeal carcinoma, a malignancy associated closely with Epstein-Barr virus (EBV), is prevalent among Chinese of Southern China origin. Epidemiological studies indicate a high prevalence of EBV in Asia with viral isolates having typical characteristics of the putative viral oncogene, latent membrane protein 1 (LMP-1), such as the loss of the Xho1 restriction site in Exon 1 and the 30-bp deletion in Exon 3. The EBV LMP-1 gene from throat washings of 120 nasopharyngeal carcinoma patients and 14 healthy individuals were analyzed. Similar analyses were also carried out on 30 and 12 postnasal space biopsies from nasopharyngeal carcinoma patients and healthy individuals, respectively. The 30-bp deletion was detected in 20% of nasopharyngeal carcinoma throat washes and in 100% of nasopharyngeal carcinoma postnasal space biopsies. Interestingly, 16% of the nasopharyngeal carcinoma biopsies possessed both the deleted and the undeleted variants, suggestive of dual infections. The notion of dual infections in nasopharyngeal carcinoma was further supported by the coexistence of both "F" and "f" (BamH1F region) EBV variants in 11% of the nasopharyngeal carcinoma biopsies. All of the throat washes and biopsies from the healthy controls showed the undeleted variant. The loss of the Xho1 restriction site was found with higher frequency both in throat washes and biopsies from patients with nasopharyngeal carcinoma. The discrepancy in the frequency of the 30-bp deletion between throat washes (20%) and postnasal space biopsies (100%) was an indication that this deletion is specific for viral isolates from primary tumour sites.
    Matched MeSH terms: Specimen Handling/methods
  5. Chua KB
    Microbes Infect., 2003 May;5(6):487-90.
    PMID: 12758277
    During the outbreak of Nipah virus encephalitis involving pigs and humans in peninsular Malaysia in 1998/1999, a conventional approach was initially undertaken to collect specimens from fruit bats by mist-netting and shooting, as an integral part of wildlife surveillance of the natural reservoir host of Nipah virus. This study describes a novel method of collecting fruit bats' urine samples using plastic sheets for isolation of Nipah virus. This novel approach resulted in the isolation of several other known and unidentified infectious agents besides Nipah virus.
    Matched MeSH terms: Specimen Handling/methods*
  6. Goossens B, Abdullah ZB, Sinyor JB, Ancrenaz M
    Folia Primatol., 2004 Jan-Feb;75(1):23-6.
    PMID: 14716150
    Matched MeSH terms: Specimen Handling/methods*
  7. Jamail M, Andrew K, Junaidi D, Krishnan AK, Faizal M, Rahmah N
    Trop Med Int Health, 2005 Jan;10(1):99-104.
    PMID: 15655019
    We conducted a field study of a rapid test (Brugia Rapid) for detection of Brugia malayi infection to validate its sensitivity and specificity under operational conditions. Seven districts in the state of Sarawak, Malaysia, which are endemic for brugian filariasis, were used to determine the test sensitivity. Determination of specificity was performed in another state in Malaysia (Bachok, Kelantan) which is non-endemic for filariasis but endemic for soil-transmitted helminths. In Sarawak both the rapid test and thick blood smear preparation were performed in the field. The rapid test was interpreted on site, whereas blood smears were taken to the district health centres for staining and microscopic examination. Sensitivity of Brugia Rapid dipstick as compared with microscopy of thick blood smears was 87% (20/23; 95% CI: 66.4-97.2) whereas the specificity was 100% (512/512). The lower sensitivity of the test in the field than in laboratory evaluations (> or =95%), was probably due to the small number of microfilaraemic individuals, in addition to difficulties in performing the test in remote villages by field personnel. The overall prevalence of brugian filariasis as determined by the dipstick is 9.4% (95% CI: 8.2-0.5) while that determined by microscopy is 0.90% (95% CI: 0.5-1.3) thus the dipstick detected about 10 times more cases than microscopy. Equal percentages of adults and children were found to be positive by the dipstick whereas microscopy showed that the number of infected children was seven times less than infected adults. The rapid dipstick test was useful as a diagnostic tool for mapping and certification phases of the lymphatic filariasis elimination programme in B. malayi-endemic areas.
    Matched MeSH terms: Specimen Handling/methods
  8. Katayon S, Noor MJ, Asma M, Ghani LA, Thamer AM, Azni I, et al.
    Bioresour Technol, 2006 Sep;97(13):1455-60.
    PMID: 16213137
    Moringa oleifera is a plant whose seeds have coagulation properties for treating water and wastewater. In this study the coagulation efficiency of Moringa oleifera kept in different storage conditions were studied. The Moringa oleifera seeds were stored at different conditions and durations; open container and closed container at room temperature (28 degrees C) and refrigerator (3 degrees C) for durations of 1, 3 and 5 months. Comparison between turbidity removal efficiency of Moringa oleifera kept in refrigerator and room temperature revealed that there was no significant difference between them. The Moringa oleifera kept in refrigerator and room temperature for one month showed higher turbidity removal efficiency, compared to those kept for 3 and 5 months, at both containers. The coagulation efficiency of Moringa oleifera was found to be dependent on initial turbidity of water samples. Highest turbidity removals were obtained for water with very high initial turbidity. In summary coagulation efficiency of Moringa oleifera was found independent of storage temperature and container, however coagulation efficiency of Moringa oleifera decreased as storage duration increased. In addition, Moringa oleifera can be used as a potential coagulant especially for very high turbidity water.
    Matched MeSH terms: Specimen Handling/methods*
  9. Ooi MH, Solomon T, Podin Y, Mohan A, Akin W, Yusuf MA, et al.
    J Clin Microbiol, 2007 Jun;45(6):1858-66.
    PMID: 17446325
    Human enterovirus 71 and coxsackievirus A16 are important causes of hand-foot-and-mouth disease (HFMD). Like other enteroviruses, they can be isolated from a range of sterile and nonsterile sites, but which clinical sample, or combination of samples, is the most useful for laboratory diagnosis of HFMD is not clear. We attempted virus culture for 2,916 samples from 628 of 725 children with HFMD studied over a 3 1/2-year period, which included two large outbreaks. Overall, throat swabs were the single most useful specimen, being positive for any enterovirus for 288 (49%) of 592 patients with a full set of samples. Vesicle swabs were positive for 169 (48%) of 333 patients with vesicles, the yield being greater if two or more vesicles were swabbed. The combination of throat plus vesicle swabs enabled the identification of virus for 224 (67%) of the 333 patients with vesicles; for this patient group, just 27 (8%) extra patients were diagnosed when rectal and ulcer swabs were added. Of 259 patients without vesicles, use of the combination of throat plus rectal swab identified virus for 138 (53%). For 60 patients, virus was isolated from both vesicle and rectal swabs, but for 12 (20%) of these, the isolates differed. Such discordance occurred for just 11 (10%) of 112 patients with virus isolated from vesicle and throat swabs. During large HFMD outbreaks, we suggest collecting swabs from the throat plus one other site: vesicles, if these are present (at least two should be swabbed), or the rectum if there are no vesicles. Vesicle swabs give a high diagnostic yield, with the added advantage of being from a sterile site.
    Matched MeSH terms: Specimen Handling/methods
  10. Chik Z, Johnston A, Tucker AT, Burn RT, Perrett D
    Biomed Chromatogr, 2007 Aug;21(8):775-9.
    PMID: 17497758
    A fast and simple capillary zone electrophoresis method was developed and validated for the determination of lidocaine in skin using tape samples. Separation was performed in a 350 mm (265 mm to window) x 50 microm i.d. fused silica capillary using a background electrolyte of phosphoric acid-Tris pH 2.5. The extraction of lidocaine from tape samples was achieved using methanol, which was diluted to 50% with water before injection. Procaine was the internal standard. The migration times for procaine and lidocaine were 2.9 and 3.2 min, respectively. The limit of quantification for lidocaine was 50 microg, with signal to noise ratio greater than 10. The calibration curve was linear from 50 to 1000 microg with r(2) greater than 0.99. The CV for both within- and between-assay imprecision and the percentage of inaccuracy for the quality control samples including lower and upper limits of quantitation were 97%. The accuracy and selectivity of this method allowed the measurement of lidocaine in tape samples obtained from a skin tape stripping study of local anesthetics in healthy subjects.
    Matched MeSH terms: Specimen Handling/methods*
  11. Bahyah MK, Murad ZA, Ghazali I, Roszaman R, Noraziana AW, Mokhtar A, et al.
    Med J Malaysia, 2010 Mar;65(1):23-6.
    PMID: 21265243 MyJurnal
    A one year study was carried out to determine the outcome of the seminal fluid parameters collected via masturbation and coitus interruptus in 151 patients who were undergoing intrauterine insemination (IUI) and patients who came for seminal analysis. There were no statistically significant differences in terms of volume, concentration, progressive motility and normal morphology from specimens collected via coitus interruptus compared to specimens collected via masturbation. Pregnancy outcomes were also comparable.
    Matched MeSH terms: Specimen Handling/methods*
  12. Chua AL, Elina HT, Lim BH, Yean CY, Ravichandran M, Lalitha P
    J Med Microbiol, 2011 Apr;60(Pt 4):481-485.
    PMID: 21183596 DOI: 10.1099/jmm.0.027433-0
    Vibrio cholerae has caused severe outbreaks of cholera worldwide with thousands of recorded deaths annually. Molecular diagnosis for cholera has become increasingly important for rapid detection of cholera as the conventional methods are time-consuming and labour intensive. However, traditional PCR tests still require cold-chain transportation and storage as well as trained personnel to perform, which makes them user-unfriendly. The aim of this study was to develop a thermostabilized triplex PCR test for cholera which is in a ready-to-use form and requires no cold chain. The PCR test specifically detects both toxigenic and non-toxigenic strains of V. cholerae based on the cholera toxin A (ctxA) and outer-membrane lipoprotein (lolB) genes. The thermostabilized triplex PCR also incorporates an internal amplification control that helps to check for PCR inhibitors in samples. PCR reagents and the specific primers were lyophilized into a pellet form in the presence of trehalose, which acts as an enzyme stabilizer. The triplex PCR was validated with 174 bacteria-spiked stool specimens and was found to be 100 % sensitive and specific. The stability of the thermostabilized PCR was evaluated using the Q10 method and it was found to be stable for approximately 7 months at 24 °C. The limit of detection of the thermostabilized triplex PCR assay was 2×10(4) c.f.u. at the bacterial cell level and 100 pg DNA at the genomic DNA level, comparable to conventional PCR methods. In conclusion, a rapid thermostabilized triplex PCR assay was developed for detecting toxigenic and non-toxigenic V. cholerae which requires minimal pipetting steps and is cold chain-free.
    Matched MeSH terms: Specimen Handling/methods
  13. Othman N, Othman NH
    Malays J Pathol, 2012 Dec;34(2):115-21.
    PMID: 23424773 MyJurnal
    The aim of this study was to examine cells (split-sample) that were retained on sampling devices used to collect conventional Pap smears (primary smears) in order to evaluate specimen adequacy and cytological diagnosis of scrapings that are routinely discarded.
    Matched MeSH terms: Specimen Handling/methods*
  14. Looi ML, Zakaria H, Osman J, Jamal R
    Clin. Lab., 2012;58(3-4):307-12.
    PMID: 22582505
    Saliva has been suggested as an attractive resource for evaluating physiological and pathological conditions in humans. This study aims to evaluate saliva sampling as an alternative to blood sampling for molecular testing.
    Matched MeSH terms: Specimen Handling/methods*
  15. Kavitha R, Tan TC, Lee HL, Nazni WA, Sofian AM
    Trop Biomed, 2013 Jun;30(2):211-9.
    PMID: 23959486 MyJurnal
    DNA identification of blow fly species can be a very useful tool in forensic entomology. One of the potential benefits that mitochondrial DNA (mtDNA) has offered in the field of forensic entomology is species determination. Conventional identification methods have limitations for sibling and closely related species of blow fly and stage and quality of the specimen used. This could be overcome by DNA-based identification methods using mitochondrial DNA which does not demand intact or undamaged specimens. Mitochondrial DNA is usually isolated from whole blow fly and legs. Alternate sources for mitochondrial DNA isolation namely, egg, larva, puparium and empty puparium were explored in this study. The sequence of DNA obtained for each sample for every life cycle stage was 100% identical for a particular species, indicating that the egg, 1st instar, 2nd instar, 3rd instar, pupa, empty puparium and adult from the same species and obtained from same generation will exhibit similar DNA sequences. The present study also highlighted the usefulness of collecting all life cycle stages of blow fly during crime scene investigation with proper preservation and subsequent molecular analysis. Molecular identification provides a strong basis for species identification and will prove an invaluable contribution to forensic entomology as an investigative tool in Malaysia.
    Matched MeSH terms: Specimen Handling/methods
  16. Shafie IN, Anderson TJ, Penderis J, Eckersall PD, McLaughlin M
    Vet J, 2013 Sep;197(3):836-41.
    PMID: 23820135 DOI: 10.1016/j.tvjl.2013.05.039
    Cerebrospinal fluid (CSF) is a potential source for disease-specific biomarkers that may assist in the staging and determining the prognosis of neurodegenerative conditions in animals. However, the validity of such putative biomarkers may be influenced by pre-analytical variables, including the procedures adopted to collect and store the CSF. This study assessed the effect of three handling practices on the stability of a panel of CSF proteins: clusterin (also known as apolipoprotein J), haptoglobin, cystatin C, and transthyretin (TTR). The three handling procedures for canine CSF were mimicked in the laboratory as follows: (1) storage in a refrigerator overnight (4 °C for 18 h); (2) carrying a sample in the pocket of a clinician (37 °C for 4h); and (3) mailing a sample to a remote laboratory for analysis (room temp for 48 h). The impact of these three scenarios on the concentrations of the selected proteins was assessed using Western blotting and compared to an aliquot of CSF that had been kept frozen. The level of clusterin was significantly reduced following 48 h at room temperature (P<0.05), while the concentration of the dimeric form of TTR increased following this handling procedure and also when held at 37 °C for 4h. A reducing agent prevented this increase at 37 °C. In conclusion, exposing CSF samples to various environmental conditions can significantly alter their protein content, a factor that must be considered in studies assessing potential biomarkers in canine CSF.
    Matched MeSH terms: Specimen Handling/methods
  17. Salleh FM, Moktar N, Yasin AM, Al-Mekhlafi HM, Anuar TS
    J Microbiol Methods, 2014 Nov;106:143-145.
    PMID: 25193442 DOI: 10.1016/j.mimet.2014.08.019
    To improve the stool concentration procedure, we modified different steps of the standard formalin-ether concentration technique and evaluated these modifications by examining stool samples collected in the field. Seven samples were found positive by the modified formalin-ether concentration technique (M-FECT). Therefore, the M-FECT procedure provides enhanced detection of Cryptosporidium oocysts.
    Matched MeSH terms: Specimen Handling/methods*
  18. Othman NH, Mohamad Zaki FH
    Asian Pac J Cancer Prev, 2014;15(20):8563-9.
    PMID: 25374168
    Sub-optimal participation is a major problem with cervical cancer screening in developing countries which have no organized national screening program. There are various notable factors such as 'embarrassment', 'discomfort' and 'no time' cited by women as they are often also the bread winners for the family. Implementation of self-sampling methods may increase their participation. The aim of this article was to provide a survey of various types of self-sampling tools which are commonly used in collection of cervical cells. We reviewed currently available self-sampling devices and collated the advantages and disadvantages of each in terms of its acceptance and its accuracy in giving desired results. In general, regardless of which device is used, self-sampling for cervical scrapings is highly acceptable to women in most of the studies cited.
    Matched MeSH terms: Specimen Handling/methods
  19. Jusman Y, Ng SC, Abu Osman NA
    ScientificWorldJournal, 2014;2014:289817.
    PMID: 25610902 DOI: 10.1155/2014/289817
    This paper investigated the effects of critical-point drying (CPD) and hexamethyldisilazane (HMDS) sample preparation techniques for cervical cells on field emission scanning electron microscopy and energy dispersive X-ray (FE-SEM/EDX). We investigated the visualization of cervical cell image and elemental distribution on the cervical cell for two techniques of sample preparation. Using FE-SEM/EDX, the cervical cell images are captured and the cell element compositions are extracted for both sample preparation techniques. Cervical cell image quality, elemental composition, and processing time are considered for comparison of performances. Qualitatively, FE-SEM image based on HMDS preparation technique has better image quality than CPD technique in terms of degree of spread cell on the specimen and morphologic signs of cell deteriorations (i.e., existence of plate and pellet drying artifacts and membrane blebs). Quantitatively, with mapping and line scanning EDX analysis, carbon and oxygen element compositions in HMDS technique were higher than the CPD technique in terms of weight percentages. The HMDS technique has shorter processing time than the CPD technique. The results indicate that FE-SEM imaging, elemental composition, and processing time for sample preparation with the HMDS technique were better than CPD technique for cervical cell preparation technique for developing computer-aided screening system.
    Matched MeSH terms: Specimen Handling/methods*
  20. Srijaya TC, Ramasamy TS, Kasim NH
    J Transl Med, 2014;12:243.
    PMID: 25182194 DOI: 10.1186/s12967-014-0243-9
    The inadequacy of existing therapeutic tools together with the paucity of organ donors have always led medical researchers to innovate the current treatment methods or to discover new ways to cure disease. Emergence of cell-based therapies has provided a new framework through which it has given the human world a new hope. Though relatively a new concept, the pace of advancement clearly reveals the significant role that stem cells will ultimately play in the near future. However, there are numerous uncertainties that are prevailing against the present setting of clinical trials related to stem cells: like the best route of cell administration, appropriate dosage, duration and several other applications. A better knowledge of these factors can substantially improve the effectiveness of disease cure or organ repair using this latest therapeutic tool. From a certain perspective, it could be argued that by considering certain proven clinical concepts and experience from synthetic drug system, we could improve the overall efficacy of cell-based therapies. In the past, studies on synthetic drug therapies and their clinical trials have shown that all the aforementioned factors have critical ascendancy over its therapeutic outcomes. Therefore, based on the knowledge gained from synthetic drug delivery systems, we hypothesize that by employing many of the clinical approaches from synthetic drug therapies to this new regenerative therapeutic tool, the efficacy of stem cell-based therapies can also be improved.
    Matched MeSH terms: Specimen Handling/methods
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links