Displaying publications 1 - 20 of 31 in total

Abstract:
Sort:
  1. Zainal Abidin NA, Abdul Wahab AH, Abdul Rahim RA, Abdul Kadir MR, Ramlee MH
    Med Biol Eng Comput, 2021 Sep;59(9):1945-1960.
    PMID: 34392448 DOI: 10.1007/s11517-021-02419-6
    Complication rates of anterior cruciate ligament reconstruction (ACL-R) were reported to be around 15% although it is a common arthroscopic procedure with good outcomes. Breakage and migration of fixators are still possible even months after surgery. A fixator with optimum stability can minimise those two complications. Factors that affect the stability of a fixator are its configuration, material, and design. Thus, this paper aims to analyse the biomechanical effects of different types of fixators (cross-pin, interference screw, and cortical button) towards the stability of the knee joint after ACL-R. In this study, finite element modelling and analyses of a knee joint attached with double semitendinosus graft and fixators were carried out. Mimics and 3-Matic softwares were used in the development of the knee joint models. Meanwhile, the graft and fixators were designed by using SolidWorks software. Once the meshes of all models were finished in 3-Matic, simulation of the configurations was done using MSC Marc Mentat software. A 100-N anterior tibial load was applied onto the tibia to simulate the anterior drawer test. Based on the findings, cross-pin was found to have optimum stability in terms of stress and strain at the femoral fixation site for better treatment of ACL-R.
    Matched MeSH terms: Tibia/surgery
  2. Thong FY, Mansor A, Ramalingam S, Yusof N
    Cell Tissue Bank, 2020 Mar;21(1):107-117.
    PMID: 31894432 DOI: 10.1007/s10561-019-09804-4
    Bone allografts donated by other individuals offer a viable alternative to autograft. Risks of disease transmission are overcome by sterilizing the bone; unfortunately sterilization methods generally affect bone functional properties including osteogenic potential and biomechanical integrity. This study aimed to determine any enhancement effect when gamma sterilised allografts was impregnated with autologous bone marrow in improving the rate and quality of integration in metaphyseal-tibial defects of rabbits. Almost all subjects showed 50% of the defect being covered by new bones by the third week and smaller residual defect size in the treated group at the fifth week. Hounsfield units at the defect site showed increasing healing in all samples, with the treated group having an apparent advantage although insignificant (p > 0.05). In the histopathological score evaluating healing over cortical and cancellous bone at the fracture site showed only slight variations between the groups (p > 0.05). Therefore no enhanced healing by the autologous bone marrow was observed when added to the bone allografts in treating the unicortical defects.
    Matched MeSH terms: Tibia/surgery
  3. Sulaiman AR, Munajat I, Liau KM, Salehuddin AY, Shukrimi A
    Med J Malaysia, 2006 Dec;61 Suppl B:48-50.
    PMID: 17600992
    Distraction osteogeneis over intramedullary nail has a benefit of decreasing the time for external fixation thus reducing the rate of associated complications. However, risk of panosteomyelitis is still the major worry. We are reporting two patients who underwent the procedure. The first case was a 13-year-old girl requiring 6 cm of femoral lengthening and the second case was a 17-year-old girl who required 5 cm of tibial lengthening. The healing index was 19.5 days/cm and 14.8 days/cm respectively, compared favorably to 30 days/cm with traditional method of distraction osteogenesis. There were mild pin tract infections and joint stiffness which responded to non-operative treatment.
    Matched MeSH terms: Tibia/surgery*
  4. Sulaiman AR, Nordin S, Faisham WI, Zulmi W, Halim AS
    J Orthop Surg (Hong Kong), 2006 Apr;14(1):64-6.
    PMID: 16598090
    Resection and reconstruction using a vascularised fibular graft is a viable alternative treatment for congenital pseudarthrosis of the tibia, although distal junctional nonunion and residual deformity are known complications that are difficult to treat. We illustrate 2 cases in which bony union was achieved following a technique using fibular grafting and intramedullary nailing, without additional bone grafting. This technique was feasible because of hypertrophy of the fibular graft.
    Matched MeSH terms: Tibia/surgery*
  5. Saw A, Phang ZH, Alrasheed MK, Gunalan R, Albaker MZ, Shanmugam R
    J Orthop Surg (Hong Kong), 2019 9 19;27(3):2309499019873987.
    PMID: 31530084 DOI: 10.1177/2309499019873987
    PURPOSE: Management of Blount disease in adolescents and young adults is complex and associated with high risk of morbidities. Gradual correction with external fixator can minimize soft tissue injury and allow subsequent adjustment in degree of correction. This study investigates the surgical outcome and complication rate of gradual correction of neglected Blount disease through single-level extra-articular corticotomy.

    METHODS: Patients treated for Blount disease using external fixator from 2002 to 2016 were recruited for the study. We used Ilizarov and Taylor Spatial Frame (TSF) external fixator to perform simultaneous correction of all the metaphyseal deformities without elevating the tibia plateau. Surgical outcome was evaluated using mechanical axis deviation (MAD), tibial femoral angle (TFA), and femoral condyle tibial shaft angle (FCTSA).

    RESULTS: A total of 22 patients with 32 tibias have been recruited for the study. The mean MAD improved from 95 ± 51.4 mm to 9.0 ± 37.7 mm (medial to midpoint of the knee), mean TFA improved from 31 ± 15° varus to 2 ± 14° valgus, and mean FCTSA improved from 53 ± 14° to 86 ± 14°. Mean duration of frame application is 9.4 months. Two patients developed pathological fractures over the distracted bones, one developed delayed consolidation and other developed overcorrection.

    CONCLUSIONS: Correction of Blount disease can be achieved by gradual correction using Ilizarov or TSF external fixator with low risk of soft tissue complication. Longer duration of frame application should be considered to reduce the risk of pathological fracture or subsequent deformation of the corrected bone.

    Matched MeSH terms: Tibia/surgery
  6. Saravanan S, Vivek AS
    Med J Malaysia, 2007 Dec;62(5):418-9.
    PMID: 18705481 MyJurnal
    This is to report on the use of growing endoprosthesis, also known as lengthening prosthesis in the management of four patients in the paedriatic age group in the Orthopaedic Oncolgy Unit at University Malaya Medical Centre. These are custom made prosthesis, designed and made in India based on measured roentrograms. The ages of these patients vary from 6 to 13 years old. These are cases of Osteosarcoma and Ewing's sarcoma around the knee. This is the first time these custom made prosthesis have ever been used in Malaysia. We feel that this is a feasible option for limb salvage in the treatment of primary bone tumours in growing children.
    Matched MeSH terms: Tibia/surgery*
  7. Ramlee MH, Sulong MA, Garcia-Nieto E, Penaranda DA, Felip AR, Kadir MRA
    Med Biol Eng Comput, 2018 Oct;56(10):1925-1938.
    PMID: 29679256 DOI: 10.1007/s11517-018-1830-3
    Pilon fractures can be caused by high-energy vertical forces which may result in long-term patient immobilization. Many experts in orthopedic surgery recommend the use of a Delta external fixator for type III Pilon fracture treatment. This device can promote immediate healing of fractured bone, minimizing the rate of complications as well as allowing early mobilization. The characteristics of different types of the Delta frame have not been demonstrated yet. By using the finite element method, this study was conducted to determine the biomechanical characteristics of six different configurations (Model 1 until Model 6). CT images from the lower limb of a healthy human were used to reconstruct three-dimensional models of foot and ankle bones. All bones were assigned with isotropic material properties and the cartilages were assigned to exhibit hyperelasticity. A linear link was used to simulate 37 ligaments at the ankle joint. Axial loads of 70 and 350 N were applied at the proximal tibia to simulate the stance and swing phase. The metatarsals and calcaneus were fixed distally in order to prevent rigid body motion. A synthetic ankle bone was used to validate the finite element model. The simulated results showed that Delta3 produced the highest relative micromovement (0.09 mm, 7 μm) during the stance and swing phase, respectively. The highest equivalent von Mises stress was found at the calcaneus pin of the Delta4 (423.2 MPa) as compared to others. In conclusion, Delta1 external fixator was the most favorable option for type III Pilon fracture treatment. Graphical abstract ᅟ.
    Matched MeSH terms: Tibia/surgery
  8. Ramlee MH, Kadir MR, Murali MR, Kamarul T
    Med Eng Phys, 2014 Oct;36(10):1322-30.
    PMID: 25127377 DOI: 10.1016/j.medengphy.2014.05.015
    Pilon fractures are commonly caused by high energy trauma and can result in long-term immobilization of patients. The use of an external fixator i.e. the (1) Delta, (2) Mitkovic or (3) Unilateral frame for treating type III pilon fractures is generally recommended by many experts owing to the stability provided by these constructs. This allows this type of fracture to heal quickly whilst permitting early mobilization. However, the stability of one fixator over the other has not been previously demonstrated. This study was conducted to determine the biomechanical stability of these external fixators in type III pilon fractures using finite element modelling. Three-dimensional models of the tibia, fibula, talus, calcaneus, navicular, cuboid, three cuneiforms and five metatarsal bones were reconstructed from previously obtained CT datasets. Bones were assigned with isotropic material properties, while the cartilage was assigned as hyperelastic springs with Mooney-Rivlin properties. Axial loads of 350 N and 70 N were applied at the tibia to simulate the stance and the swing phase of a gait cycle. To prevent rigid body motion, the calcaneus and metatarsals were fixed distally in all degrees of freedom. The results indicate that the model with the Delta frame produced the lowest relative micromovement (0.03 mm) compared to the Mitkovic (0.05 mm) and Unilateral (0.42 mm) fixators during the stance phase. The highest stress concentrations were found at the pin of the Unilateral external fixator (509.2 MPa) compared to the Mitkovic (286.0 MPa) and the Delta (266.7 MPa) frames. In conclusion, the Delta external fixator was found to be the most stable external fixator for treating type III pilon fractures.
    Matched MeSH terms: Tibia/surgery
  9. Pan KL, Mourougayah V, Jayamalar T
    Med J Malaysia, 2003 Dec;58(5):783-5.
    PMID: 15190672
    We present an elderly patient with a squamous cell carcinoma over the subcutaneous aspect of the leg involving the tibia. En bloc resection of the tumour together with a 10 centimetre segment of the tibia was done. The resected bone was autoclaved, replaced in its original position and stabilized with bone cement and a locked nail. This allowed early ambulation with minimal cost.
    Matched MeSH terms: Tibia/surgery*
  10. Ng CK, Chen JY, Yeh JZY, Ho JPY, Merican AM, Yeo SJ
    J Arthroplasty, 2018 06;33(6):1936-1944.
    PMID: 29395720 DOI: 10.1016/j.arth.2017.12.025
    BACKGROUND: We hypothesized that there is a correlation between the distal femoral rotation and proximal tibial joint line obliquity in nonarthritic knees. This has significance for kinematic knee arthroplasty, in which the target knee alignment desired approximates the knee before disease.

    METHODS: Fifty computed tomography scans of nonarthritic knees were evaluated using three-dimensional image processing software. Four distal femoral rotational axes were determined in the axial plane: the transepicondylar axis (TEA), transcondylar axis (TCA), posterior condylar axis (PCA), and a line perpendicular to Whiteside's anterior-posterior axis. Then, angles were measured relative to the TEA. Tibial joint line obliquity was measured as the angle between the proximal tibial plane and a line perpendicular to the axis of the tibia.

    RESULTS: There was a strong positive correlation between PCA-TEA and tibial joint line obliquity (r = 0.68, P < .001) as well as TCA-TEA and tibial joint line obliquity (r = 0.69, P < .001). In addition, the tibial joint line obliquity and TCA-TEA angles were similar, 3.7° ± 2.2° (mean ± standard deviation) and 3.5° ± 1.7°, respectively (mean difference, 0.2° ± 0.2°; P = .369).

    CONCLUSION: Both PCA-TEA and TCA-TEA strongly correlated with proximal tibial joint line obliquity indicating a relationship between distal femoral rotational geometry and proximal tibial inclination. These findings could imply that the native knee in flexion attempts to balance the collateral ligaments toward a rectangular flexion space. A higher tibial varus inclination is matched with a more internally rotated distal femur relative to the TEA.

    Matched MeSH terms: Tibia/surgery*
  11. Najafpour HD, Suzina AH, Nizam A, Samsudin AR
    Med J Malaysia, 2004 May;59 Suppl B:121-2.
    PMID: 15468848
    There was a significant increased in Absolute Contact Length measurements of endosteal bone growth along the Nickel-Titanium (NiTi) implant coated with the natural coral powder and Hydroxyapatite (HA) compared to the non-calcium coated implants. This study demonstrated that coated implants seemed to show earlier and higher osseointergration phenomena compared to non coated ones. Furthermore, there was significantly greater bone-to-implant contact at the apical 1/3rd of the coated implants.
    Matched MeSH terms: Tibia/surgery
  12. Muhammad Abdul Jamil MK, Abdul Rashid AH, Ibrahim S
    J Pediatr Orthop B, 2013 May;22(3):207-12.
    PMID: 22182834 DOI: 10.1097/BPB.0b013e32834ecc01
    This preliminary report is on two patients with congenital pseudoarthrosis of the tibia who had a persistent nonunion following intramedullary rodding and bone grafting. We do not advocate repeated surgery to achieve union. When limb length discrepancy becomes greater than 5 cm, we proceeded with an Ilizarov procedure with the primary aim of equalizing limb length rather than achieving union. Healing of the pseudoarthrosis occurred in both patients after lengthening over the intramedullary rod without compression of the nonunion site. We believe that union occurs because of hyperaemia during the lengthening. This approach minimizes the repeated surgeries that are usually needed and thus ensures a more normal childhood without frequent hospitalizations.
    Matched MeSH terms: Tibia/surgery*
  13. Lee YS, Howell SM, Won YY, Lee OS, Lee SH, Vahedi H, et al.
    Knee Surg Sports Traumatol Arthrosc, 2017 Nov;25(11):3467-3479.
    PMID: 28439636 DOI: 10.1007/s00167-017-4558-y
    PURPOSE: A systematic review was conducted to answer the following questions: (1) Does kinematically aligned (KA) total knee arthroplasty (TKA) achieve clinical outcomes comparable to those of mechanically aligned (MA) TKA? (2) How do the limb, knee, and component alignments differ between KA and MA TKA? (3) How is joint line orientation angle (JLOA) changed from the native knee in KA TKA compared to that in MA TKA?

    METHODS: Nine full-text articles in English that reported the clinical and radiological outcomes of KA TKA were included. Five studies had a control group of patients who underwent MA TKA. Data on patient demographics, clinical scores, and radiological results were extracted. There were two level I, one level II, three level III, and three level IV studies. Six of the nine studies used patient-specific instrumentation, one study used computer navigation, and two studies used manual instrumentation.

    RESULTS: The clinical outcomes of KA TKA were comparable or superior to those of MA TKA with a minimum 2-year follow-up. Limb and knee alignment in KA TKA was similar to those in MA TKA, and component alignment showed slightly more varus in the tibial component and slightly more valgus in the femoral component. The JLOA in KA TKA was relatively parallel to the floor compared to that in the native knee and not oblique (medial side up and lateral side down) compared to that in MA TKA. The implant survivorship and complication rate of the KA TKA were similar to those of the MA TKA.

    CONCLUSION: Similar or better clinical outcomes were produced by using a KA TKA at early-term follow-up and the component alignment differed from that of MA TKA. KA TKA seemed to restore function without catastrophic failure regardless of the alignment category up to midterm follow-up. The JLOA in KA TKA was relatively parallel to the floor similar to the native knee compared to that in MA TKA. The present review of nine published studies suggests that relatively new kinematic alignment is an acceptable and alternative alignment to mechanical alignment, which is better understood. Further validation of these findings requires more randomized clinical trials with longer follow-up.

    LEVEL OF EVIDENCE: Level II.

    Matched MeSH terms: Tibia/surgery
  14. Lee SH, Lee OS, Teo SH, Lee YS
    Gait Posture, 2017 09;57:57-68.
    PMID: 28577508 DOI: 10.1016/j.gaitpost.2017.05.023
    We conducted a meta-analysis to analyze how high tibial osteotomy (HTO) changes gait and focused on the following questions: (1) How does HTO change basic gait variables? (2) How does HTO change the gait variables in the knee joint? Twelve articles were included in the final analysis. A total of 383 knees was evaluated. There were 237 open wedge (OW) and 143 closed wedge (CW) HTOs. There were 4 level II studies and 8 level III studies. All studies included gait analysis and compared pre- and postoperative values. One study compared CWHTO and unicompartmental knee arthroplasty (UKA), and another study compared CWHTO and OWHTO. Five studies compared gait variables with those of healthy controls. One study compared operated limb gait variables with those in the non-operated limb. Gait speed, stride length, knee adduction moment, and lateral thrust were major variables assessed in 2 or more studies. Walking speed increased and stride length was increased or similar after HTO compared to the preoperative value in basic gait variables. Knee adduction moment and lateral thrust were decreased after HTO compared to the preoperative knee joint gait variables. Change in co-contraction of the medial side muscle after surgery differed depending on the degree of frontal plane alignment. The relationship between change in knee adduction moment and change in mechanical axis angle was controversial. Based on our systematic review and meta-analysis, walking speed and stride length increased after HTO. Knee adduction moment and lateral thrust decreased after HTO compared to the preoperative values of gait variables in the knee joint.
    Matched MeSH terms: Tibia/surgery*
  15. Lee OS, Ahn S, Ahn JH, Teo SH, Lee YS
    Arch Orthop Trauma Surg, 2018 Feb;138(2):227-236.
    PMID: 29143167 DOI: 10.1007/s00402-017-2826-4
    INTRODUCTION: The purpose of this systematic review and meta-analysis was to evaluate the efficacy of concurrent cartilage procedures during high tibial osteotomy (HTO) for medial compartment osteoarthritis (OA) by comparing the outcomes of studies that directly compared the use of HTO plus concurrent cartilage procedures versus HTO alone.

    MATERIALS AND METHODS: Results that are possible to be compared in more than two articles were presented as forest plots. A 95% confidence interval was calculated for each effect size, and we calculated the I 2 statistic, which presents the percentage of total variation attributable to the heterogeneity among studies. The random effects model was used to calculate the effect size.

    RESULTS: Seven articles were included to the final analysis. Case groups were composed of HTO without concurrent procedures and control groups were composed of HTO with concurrent procedures such as marrow stimulation procedure, mesenchymal stem cell transplantation, and injection. The case group showed a higher hospital for special surgery score and mean difference was 4.10 [I 2 80.8%, 95% confidence interval (CI) - 9.02 to 4.82]. Mean difference of the mechanical femorotibial angle in five studies was 0.08° (I 2 0%, 95% CI - 0.26 to 0.43). However, improved arthroscopic, histologic, and MRI results were reported in the control group.

    CONCLUSION: Our analysis support that concurrent procedures during HTO for medial compartment OA have little beneficial effect regarding clinical and radiological outcomes. However, they might have some beneficial effects in terms of arthroscopic, histologic, and MRI findings even though the quality of healed cartilage is not good as that of original cartilage. Therefore, until now, concurrent procedures for medial compartment OA have been considered optional. Nevertheless, no conclusions can be drawn for younger patients with focal cartilage defects and concomitant varus deformity. This question needs to be addressed separately.

    Matched MeSH terms: Tibia/surgery*
  16. Kwan MK, Penafort R, Saw A
    Med J Malaysia, 2004 Dec;59 Suppl F:39-41.
    PMID: 15941159
    Joint stiffness is one of the complications of limb procedure. It developes as a result of failure of knee flexors to lengthen in tandem with the bone, especially when there is inadequate physical therapy to provide active and passive mobilization of the affected joint. We are reporting four patients who developed fixed flexion contracture of their knees during bone lengthening procedure for the tibia with Ilizarov external fixator. Three of them were treated for congenital pseudoarthrosis and one was for fibular hemimelia. None of them were able to visit the physiotherapist even on a weekly basis. A splint was constructed from components of Ilizarov external fixator and applied on to the existing frame to passively extend the affected knee. Patients and their family members were taught to perform this exercise regularly and eventually near complete correction were achieved. With this result, we would like to recommend the use of this "Passive Knee Extension Splint" to avoid knee flexion Contracture during limb lengthening procedures with Ilizarov external fixators.
    Matched MeSH terms: Tibia/surgery*
  17. Kow RY, Yuen JC, Ahmad Alwi AA, Abas MF, Low CL
    JBJS Case Connect, 2019 6 25;9(2):e0163.
    PMID: 31233428 DOI: 10.2106/JBJS.CC.18.00163
    CASE: A 17-year-old male sustained an open fracture of the right medial malleolus (MM) with significant bone and soft tissue loss following a motor-vehicle accident. Following serial wound debridement, his ankle was effectively reconstructed with MM antiglide plate stabilization, iliac autogenous bone graft, and a free radial forearm soft tissue flap.

    CONCLUSIONS: Open MM fracture with bone and soft tissue loss is rare. It is feasible to treat this injury with a novel surgical reconstruction technique involving autogenous bicortical iliac bone graft and radial forearm free flap.

    Matched MeSH terms: Tibia/surgery*
  18. Kim JE, Won S, Jaffar MSA, Lee JI, Kim TW, Lee YS
    Knee, 2020 Jun;27(3):940-948.
    PMID: 32331827 DOI: 10.1016/j.knee.2020.04.008
    BACKGROUND: Open-wedge high tibial osteotomy (OWHTO) produces three- dimensional (3D) geometric changes. Among them, increased posterior tibial slope (PTS), and altered coronal inclination that induces unintended tibial translation may affect anterior cruciate ligament (ACL) status. The purpose of current study was to evaluate the geometric changes following OWHTO, such as increasing PTS and decreasing tibial subluxation, which may affect the status of ACL.

    METHODS: From April 2014 to December 2015, a total of 72 knees in 64 patients that underwent OWHTO, second-look arthroscopy, and magnetic resonance imaging (MRI) assessment, were enrolled. Preoperative and postoperative coronal and sagittal translation, joint line orientation angle, the distance between medial femoral notch marginal line and medial tibial spine, and PTS were evaluated. ACL status was arthroscopically graded from grade 1 (best) to 4 (worst). The MRI signal of the graft in three portions (proximal, middle, and distal) was graded from grade 1 (best) to 4 (worst).

    RESULTS: High grade (3: partial, and 4: complete rupture) was noted in 28 cases (38.9%) at the second-look arthroscopy compared with 10 cases (13.9%) at index arthroscopy. The MRI signal grade significantly increased at follow up MRI compared with preoperative MRI (P<0.01). An increased signal was commonly noted in the middle and distal portions of the graft.

    CONCLUSIONS: Geometric changes after OWHTO were related to ACL deterioration. The ACL was commonly affected at the middle and distal portions and rarely at the proximal portion. There is a possibility of impingement because of the geometric changes.

    LEVEL OF EVIDENCE: Level IV.

    Matched MeSH terms: Tibia/surgery
  19. Khadijah K, Mashita M, Saidu MF, Fazilah F, Khalid KA
    Med J Malaysia, 2004 May;59 Suppl B:123-4.
    PMID: 15468849
    This study is to qualitatively evaluate a locally produced hydroxyapatite (HA), made by AMREC-SIRIM in an experimental animal bone defect using New Zealand White (NZW) rabbits. HA cylindrical blocks measuring 2.5 mm (D) x 1.0 mm (H) were implanted in the rabbits' left tibia. The tibias were harvested within one to three weeks post-implantation. The implantion site was cut into thin undecalcified sections of about 30 microm to 60 microm and stained with Toluidine Blue and Goldner's Masson Trichrome. Microscopic examinations using standard light microscopy of these slides were performed.
    Matched MeSH terms: Tibia/surgery
  20. Katchy AU, Agu AU, Ikele IT, Esom E, Nto NJ
    Niger J Clin Pract, 2019 Oct;22(10):1423-1429.
    PMID: 31607734 DOI: 10.4103/njcp.njcp_93_19
    Background: The morphological parameters of the proximal tibia play a major role in total knee replacement and there are ethnic and gender variations to these parameters.

    Aim: To evaluate parameters of the proximal tibia geometry amongst the Igbos of South Eastern Nigeria and discuss the clinical implications in total knee replacement.

    Methods: The proximal tibia parameters of 558 adult tibiae bones, 300 right-sided and 258 left-sided, collected from the osteological unit of the department of anatomy University of Nigeria Enugu campus were measured using a Venier calipers.

    Results: The values of the determined parameters are as follows: anterior posterior dimension (APD): 5.50 cm, medial lateral dimension (MLD):7.53 ± 5.56 cm, proximal length (PL): 7.32 ± 0.67 cm, proximal width (PW) CM: 4.10 ± 0.30 cm, medial tibia posterior slope (MTPS):11.36 ± 4.15° and lateral tibia posterior slope (LTPS):5.65 ± 2.72°. The correlation test between these parameters of the proximal tibia shows a strong significant correlation between LPTS and MPTS (r =0.814, P < .001). The comparison of the means of the MPTS of both sides using independent samples t test shows a mean difference that is not significant (p =0.628). A comparison of the values with other populations shows significant mean difference for MLD with that of Chinese and American populations (p < .05). The mean difference between the APD of this study and the Chinese is significant (p =0.007). A comparison of MPTS and LPTS for Malaysian, Chinese, and white Americans shows a significance difference for all the three populations (p tibia surface coverage in total knee replacement amongst the Igbo population.

    Matched MeSH terms: Tibia/surgery
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links