Displaying publications 1 - 20 of 33 in total

Abstract:
Sort:
  1. Ogunfowokan O, Ogunfowokan BA, Nwajei AI
    Afr J Prim Health Care Fam Med, 2020 Jun 17;12(1):e1-e8.
    PMID: 32634015 DOI: 10.4102/phcfm.v12i1.2212
    BACKGROUND: Malaria diagnosis using microscopy is currently the gold standard. However, malaria rapid diagnostic tests (mRDTs) were developed to simplify the diagnosis in regions without access to functional microscopy.

    AIM: The objective of this study was to compare the diagnostic accuracy of mRDT CareStatTM with microscopy.

    SETTING: This study was conducted in the paediatric primary care clinic of the Federal Medical Centre, Asaba, Nigeria.

    METHODS: A cross-sectional study for diagnostic accuracy was conducted from May 2016 to October 2016. Ninety-eight participants were involved to obtain a precision of 5%, sensitivity of mRDT CareStatTM of 95% from published work and 95% level of confidence after adjusting for 20% non-response rate or missing data. Consecutive participants were tested using both microscopy and mRDT. The results were analysed using EPI Info Version 7.

    RESULTS: A total of 98 children aged 3-59 months were enrolled. Malaria prevalence was found to be 53% (95% confidence interval [CI] = 46% - 60%), whilst sensitivity and specificity were 29% (95% CI = 20% - 38%) and 89% (95% CI = 83% - 95%), respectively. The positive and negative predictive values were 75% (95% CI = 66.4% - 83.6%) and 53% (95% CI = 46% - 60%), respectively.

    CONCLUSION: Agreement between malaria parasitaemia using microscopy and mRDT positivity increased with increase in the parasite density. The mRDT might be negative when malaria parasite density using microscopy is low.

    Matched MeSH terms: Diagnostic Tests, Routine/methods*
  2. Mussa A, Talib M, Mohamed Z, Hajissa K
    BMC Res Notes, 2019 Jun 11;12(1):334.
    PMID: 31186056 DOI: 10.1186/s13104-019-4361-6
    OBJECTIVE: Rapid diagnostic tests (RDTs) play a crucial role in the management and control of malaria infection. The histidine-rich protein 2 (PfHRP-2) based RDTs are the most commonly used RDTs for malaria diagnosis in Sudan. Deletion of pfhrp2 in Plasmodium falciparum genome affect the accuracy of PfHRP-2 based RDT kits. This study aimed to identify molecular variation of pfhrp2 among suspected malaria patients from different clinics in Omdurman, Sudan.

    RESULTS: A noticeable variation between the RDT (Alltest Biotech, China) and nPCR results was observed, for RDT 78% (46/59) were P. falciparum positive, 6.8% (4/59) were co-infected with both P. falciparum and Plasmodium vivax, 15.3% (9/59) were negative by the RDT. However, when the nPCR was applied only 44.1% (26/59) and 55.9% (33/59) was P. falciparum positive and negative respectively. The pfhrp2 was further amplified form all nPCR positive samples. Only 17 DNA samples were positive from the 26 positive P. falciparum, interestingly, variation in band sizes was observed and further confirmed by DNA sequencing, and sequencing analysis revealed a high-level of genetic diversity of the pfhrp2 gene in the parasite population from the study area. However, despite extreme sequence variation, diversity of PfHRP2 does not appear to affect RDT performance.

    Matched MeSH terms: Diagnostic Tests, Routine/methods
  3. Moghadam ZK, Ghaffarifar F, Khalilpour A, Abdul Aziz F, Saadatnia G, Noordin R
    Clin Vaccine Immunol, 2013 Apr;20(4):501-5.
    PMID: 23365208 DOI: 10.1128/CVI.00019-13
    Hydatidosis is a public health problem in many parts of the world, and improvement in diagnosis of the disease is still being pursued. Protoscoleces of Echinococcus granulosus were isolated from hydatid cysts collected from naturally infected sheep slaughtered in abattoirs in Iran. Sonicated extract of protoscolex was subjected to two-dimensional gel electrophoresis and Western blot analysis. Primary antibodies were from serum samples from 130 hydatidosis patients, 38 individuals infected with other parasitic infections, and 30 healthy people, whereas peroxidase (HRP)-conjugated anti-human IgG and IgG4 were used as secondary antibodies. The recombinant form of the identified protein was produced and tested for its sensitivity and specificity for the detection of human hydatidosis. An antigenic band of ∼60 kDa was found to be sensitive (82%) and specific (100%) for the detection of hydatidosis when probed with anti-human IgG4-HRP, while the sensitivity and specificity were 33 and 100%, respectively, with anti-human IgG-HRP. By mass spectrometry, the band was identified as protoscolex tegument paramyosin. The sensitivity and specificity of full-length paramyosin-recombinant protein in IgG4 blots were found to be 86 and 98%, respectively. In conclusion, IgG4 detection of Echinococcus granulosus paramyosin was found to be useful for the diagnosis of human hydatidosis.
    Matched MeSH terms: Diagnostic Tests, Routine/methods*
  4. Liem LK, Choong LH, Woo KT
    Clin Biochem, 2002 May;35(3):181-7.
    PMID: 12074825
    OBJECTIVE: Dihydropyrimidine dehydrogenase (DPD) catalyzes the degradation of thymine, uracil, and the chemotherapeutic drug 5-Fluorouracil. In general reverse-phase high pressure liquid chromatography is the standard method for separating 5-[2-(14)C]Fluorouracil and 5-[2-(14)C]Fluoro-5,6-dihydrouracil. However, the use of 100% aqueous solution (as HPLC mobile phase) may collapse the C-18 bonded phase and result in a retention time shift. The aim of this study is to develop a rapid, reproducible, sensitive method for screening partial DPD deficiency in healthy volunteers.

    DESIGN AND METHODS: The activity of DPD was measured using 5-[2- (14)C]Fluorouracil (5-[2-(14)C]FUra) followed by separation of substrate and product 5-[2-(14)C]FUraH(2) with a 15 x 4.6 mm I.D., 5 microm particle size (d(p)) porous graphitic carbon (PGC) column (Hypercarb(R)) and HPLC with online detection of the radioactivity. This was standardized using the protein concentration of the cytosol (NanoOrange(R) Protein Quantitation).

    RESULTS: Complete baseline separation of 5-[2-(14)C]Fluorouracil (5-[2-(14)C]FUra) and 5-[2-(14)C]Fluoro-5,6-dihydrouracil (5-[2-(14)C]FUraH(2)) was achieved using a porous graphitic carbon (PGC) column. The detection limit for 5-[2-(14)C]FUraH(2) was 0.4 pmol.

    CONCLUSIONS: By using linear gradient separation (0.1% Trifluoroacetic acid [TFA] in water to 100% Methanol) protocols in concert with PGC columns (Hypercarb(R)), we have demonstrated that a PGC column has a distinct advantage over C-18 reverse phase columns in terms of column stability (pH 1-14). This method provides an improvement on the specific assay for DPD enzyme activity. It is rapid, reproducible and sensitive and can be used for routine screening for healthy and cancer patients for partial and profound DPD deficiency before treatment with 5- FUra.

    Matched MeSH terms: Diagnostic Tests, Routine/methods*
  5. Vola A, Tamarozzi F, Noordin R, Yunus MH, Khanbabaie S, De Silvestri A, et al.
    Diagn Microbiol Infect Dis, 2018 Sep;92(1):31-33.
    PMID: 29776711 DOI: 10.1016/j.diagmicrobio.2018.04.007
    Rapid diagnostic tests for cystic echinococcosis (CE) are convenient to support ultrasound diagnosis in uncertain cases, especially in resource-limited settings. We found comparable diagnostic performances of the experimental Hyd Rapid Test and the commercial VIRapid HYDATIDOSIS Test, used in our diagnostic laboratory, using samples from well-characterized hepatic CE cases.
    Matched MeSH terms: Diagnostic Tests, Routine/methods*
  6. Wong WCW, Lo YR, Jiang S, Peng M, Zhu S, Kidd MR, et al.
    Fam Pract, 2018 12 12;35(6):731-737.
    PMID: 29741661 DOI: 10.1093/fampra/cmy032
    Objective: The study aimed to decentralize hepatitis testing and management services to primary care in China.

    Methods: A nationwide representative provider survey amongst community health centres (CHCs) using randomized stratified sampling methods was conducted between September and December 2015. One hundred and eighty CHCs and frontline primary care practitioners from 20 cities across three administrative regions of Western, Central and Eastern China were invited to participate.

    Results: One hundred and forty-nine clinicians-in-charge (79%), 1734 doctors and 1846 nurses participated (86%). Majority of CHCs (80%, 95% CI: 74-87) offered hepatitis B testing, but just over half (55%, 95% CI: 46-65) offered hepatitis C testing. The majority of doctors (87%) and nurses (85%) felt that there were benefits for providing hepatitis testing at CHCs. The major barriers for not offering hepatitis testing were lack of training (54%) and financial support (23%). Multivariate analysis showed that the major determinants for CHCs to offer hepatitis B and C testing were the number of nurses (AOR 1.1) and written policies for hepatitis B diagnosis (AOR 12.7-27.1), and for hepatitis B the availability of reproductive health service.

    Conclusions: Primary care providers in China could play a pivotal role in screening, diagnosing and treating millions of people with chronic hepatitis B and C in China.

    Matched MeSH terms: Diagnostic Tests, Routine/methods*
  7. Tan AF, Sakam SSB, Rajahram GS, William T, Abd Rachman Isnadi MF, Daim S, et al.
    Front Cell Infect Microbiol, 2022;12:1023219.
    PMID: 36325471 DOI: 10.3389/fcimb.2022.1023219
    BACKGROUND: Plasmodium knowlesi causes zoonotic malaria across Southeast Asia. First-line diagnostic microscopy cannot reliably differentiate P. knowlesi from other human malaria species. Rapid diagnostic tests (RDTs) designed for P. falciparum and P. vivax are used routinely in P. knowlesi co-endemic areas despite potential cross-reactivity for species-specific antibody targets.

    METHODS: Ten RDTs were evaluated: nine to detect clinical P. knowlesi infections from Malaysia, and nine assessing limit of detection (LoD) for P. knowlesi (PkA1-H.1) and P. falciparum (Pf3D7) cultures. Targets included Plasmodium-genus parasite lactate dehydrogenase (pan-pLDH) and P. vivax (Pv)-pLDH.

    RESULTS: Samples were collected prior to antimalarial treatment from 127 patients with microscopy-positive PCR-confirmed P. knowlesi mono-infections. Median parasitaemia was 788/µL (IQR 247-5,565/µL). Pan-pLDH sensitivities ranged from 50.6% (95% CI 39.6-61.5) (SD BIOLINE) to 87.0% (95% CI 75.1-94.6) (First Response® and CareStart™ PAN) compared to reference PCR. Pv-pLDH RDTs detected P. knowlesi with up to 92.0% (95% CI 84.3-96.7%) sensitivity (Biocredit™). For parasite counts ≥200/µL, pan-pLDH (Standard Q) and Pv-pLDH RDTs exceeded 95% sensitivity. Specificity of RDTs against 26 PCR-confirmed negative controls was 100%. Sensitivity of six highest performing RDTs were not significantly different when comparing samples taken before and after (median 3 hours) antimalarial treatment. Parasite ring stages were present in 30% of pre-treatment samples, with ring stage proportions (mean 1.9%) demonstrating inverse correlation with test positivity of Biocredit™ and two CareStart™ RDTs.For cultured P. knowlesi, CareStart™ PAN demonstrated the lowest LoD at 25 parasites/µL; LoDs of other pan-pLDH ranged from 98 to >2000 parasites/µL. Pv-pLDH LoD for P. knowlesi was 49 parasites/µL. No false-positive results were observed in either P. falciparum-pLDH or histidine-rich-protein-2 channels.

    CONCLUSION: Selected RDTs demonstrate sufficient performance for detection of major human malaria species including P. knowlesi in co-endemic areas where microscopy is not available, particularly for higher parasite counts, although cannot reliably differentiate among non-falciparum malaria.

    Matched MeSH terms: Diagnostic Tests, Routine/methods
  8. Cho SJ, Lee J, Lee HJ, Jo HY, Sinniah M, Kim HY, et al.
    Int J Biol Sci, 2016;12(7):824-35.
    PMID: 27313496 DOI: 10.7150/ijbs.14408
    Rapid diagnostic tests (RDTs) can detect anti-malaria antibodies in human blood. As they can detect parasite infection at the low parasite density, they are useful in endemic areas where light infection and/or re-infection of parasites are common. Thus, malaria antibody tests can be used for screening bloods in blood banks to prevent transfusion-transmitted malaria (TTM), an emerging problem in malaria endemic areas. However, only a few malaria antibody tests are available in the microwell-based assay format and these are not suitable for field application. A novel malaria antibody (Ab)-based RDT using a differential diagnostic marker for falciparum and vivax malaria was developed as a suitable high-throughput assay that is sensitive and practical for blood screening. The marker, merozoite surface protein 1 (MSP1) was discovered by generation of a Plasmodium-specific network and the hierarchical organization of modularity in the network. Clinical evaluation revealed that the novel Malaria Pf/Pv Ab RDT shows improved sensitivity (98%) and specificity (99.7%) compared with the performance of a commercial kit, SD BioLine Malaria P.f/P.v (95.1% sensitivity and 99.1% specificity). The novel Malaria Pf/Pv Ab RDT has potential for use as a cost-effective blood-screening tool for malaria and in turn, reduces TTM risk in endemic areas.
    Matched MeSH terms: Diagnostic Tests, Routine/methods*
  9. Ong TYY, Khan NA, Siddiqui R
    J Clin Microbiol, 2017 07;55(7):1989-1997.
    PMID: 28404683 DOI: 10.1128/JCM.02300-16
    Acanthamoeba spp. and Balamuthia mandrillaris are causative agents of granulomatous amoebic encephalitis (GAE), while Naegleria fowleri causes primary amoebic meningoencephalitis (PAM). PAM is an acute infection that lasts a few days, while GAE is a chronic to subacute infection that can last up to several months. Here, we present a literature review of 86 case reports from 1968 to 2016, in order to explore the affinity of these amoebae for particular sites of the brain, diagnostic modalities, treatment options, and disease outcomes in a comparative manner.
    Matched MeSH terms: Diagnostic Tests, Routine/methods
  10. Barber BE, William T, Grigg MJ, Piera K, Yeo TW, Anstey NM
    J Clin Microbiol, 2013 Apr;51(4):1118-23.
    PMID: 23345297 DOI: 10.1128/JCM.03285-12
    Plasmodium knowlesi can cause severe and fatal human malaria in Southeast Asia. Rapid diagnosis of all Plasmodium species is essential for initiation of effective treatment. Rapid diagnostic tests (RDTs) are sensitive for detection of uncomplicated and severe falciparum malaria but have not been systematically evaluated in knowlesi malaria. At a tertiary referral hospital in Sabah, Malaysia, we prospectively evaluated the sensitivity of two combination RDTs for the diagnosis of uncomplicated and severe malaria from all three potentially fatal Plasmodium species, using a pan-Plasmodium lactate dehydrogenase (pLDH)-P. falciparum histidine-rich protein 2 (PfHRP2) RDT (First Response) and a pan-Plasmodium aldolase-PfHRP2 RDT (ParaHIT). Among 293 hospitalized adults with PCR-confirmed Plasmodium monoinfection, the sensitivity of the pLDH component of the pLDH-PfHRP2 RDT was 74% (95/129; 95% confidence interval [CI], 65 to 80%), 91% (110/121; 95% CI, 84 to 95%), and 95% (41/43; 95% CI, 85 to 99%) for PCR-confirmed P. knowlesi, P. falciparum, and P. vivax infections, respectively, and 88% (30/34; 95% CI, 73 to 95%), 90% (38/42; 95% CI, 78 to 96%), and 100% (12/12; 95% CI, 76 to 100%) among patients tested before antimalarial treatment was begun. Sensitivity in severe malaria was 95% (36/38; 95% CI, 83 to 99), 100% (13/13; 95% CI, 77 to 100), and 100% (7/7; 95% CI, 65 to 100%), respectively. The aldolase component of the aldolase-PfHRP2 RDT performed poorly in all Plasmodium species. The pLDH-based RDT was highly sensitive for the diagnosis of severe malaria from all species; however, neither the pLDH- nor aldolase-based RDT demonstrated sufficiently high overall sensitivity for P. knowlesi. More sensitive RDTs are needed in regions of P. knowlesi endemicity.
    Matched MeSH terms: Diagnostic Tests, Routine/methods*
  11. Alia SN, Joseph N, Philip N, Azhari NN, Garba B, Masri SN, et al.
    J Infect Public Health, 2018 11 27;12(2):263-269.
    PMID: 30502041 DOI: 10.1016/j.jiph.2018.10.137
    BACKGROUND: Leptospirosis is often misdiagnosed with several other tropical febrile illnesses in Malaysia due to similarities in clinical manifestations. Although treatment regimens could be started based on clinical judgments, early diagnosis has become paramount as a guide to chemotherapeutic interventions. Confirmed laboratory diagnosis through MAT or PCR is time consuming and usually available only in reference laboratories and not practical in healthcare settings. Rapid and easy to perform diagnostic tests are widely used in these settings as the point of care diagnosis. The present study was undertaken to compare the diagnostic performance of two IgM based immunodiagnostic assay kits for acute leptospirosis.

    METHODS: A total of 50 serum samples were collected from patients clinically suspected for acute leptospirosis on admission in the Hospital Serdang, from June 2016 to June 2017. All the samples were subjected to MAT, lipL32 PCR and the two rapid tests (Leptocheck-WB and ImmuneMed Leptospira IgM Duo Rapid test).

    RESULTS: Out of the 50 clinically suspected patients sampled, 19 were confirmed positive for leptospirosis. Six (12%) were confirmed by MAT and 13 (26%) by PCR. Similarly, of the 50 clinically suspected cases, 17 (34%) showed positivity for Leptocheck-WB and 7 (14%) for ImmuneMed Leptospira IgM Duo Rapid test. The overall sensitivity and specificity was 47.37% and 80.65% for Leptocheck-WB, and 21.05% and 90.32% for ImmuneMed Leptospira IgM Duo Rapid test. In another set of previously confirmed MAT positive samples (1:400-1:3600) obtained from a reference laboratory, Leptocheck-WB showed higher sensitivity (90.72%) than ImmuneMed Leptospira IgM Duo Rapid test (40.21%), and comparable specificity for ImmuneMed Leptospira IgM Duo Rapid test (88.89%) and Leptocheck-WB (82.86%).

    CONCLUSION: The sensitivity was higher for Leptocheck-WB and had a comparable specificity with ImmuneMed Leptospira IgM Duo Rapid test. Therefore, based on the present study, Leptocheck-WB is found to be a more sensitive rapid immunodiagnostic test for acute leptospirosis screening in hospital settings.

    Matched MeSH terms: Diagnostic Tests, Routine/methods*
  12. Sivanandy P, Zi Xien F, Woon Kit L, Tze Wei Y, Hui En K, Chia Lynn L
    J Infect Public Health, 2018 09 10;12(2):153-158.
    PMID: 30213468 DOI: 10.1016/j.jiph.2018.08.005
    The H7N9 subtype of avian influenza is an enzootic and airborne virus which caused an influenza outbreak in China. Infected individuals mostly worked with poultry, suggesting H7N9 virus-infected poultry as the primary source of human infection. Significantly increased levels of proinflammatory mediators (chemokines, cytokines) during virus infection could hamper the immune system and aggravate the infection. Severe cases are marked by fulminant pneumonia, acute respiratory distress syndrome (ARDS) and encephalopathy. Left untreated, the condition may rapidly progress to multi-organ failure and death. Reverse transcription polymerase chain reaction (rRT-PCR) is the gold standard diagnostic test for H7N9 avian influenza. Use of neurominidase inhibitor antivirals remain the main treatment. New antivirals are developed to counteract neurominidase inhibitor resistance H7N9 viral strains. Corticosteroid use in viral pneumonia may provoke mortality and longer viral shedding time. Subjects at high risk of contracting avian influenza H7N9 infection are recommended to receive annual seasonal influenza vaccination.
    Matched MeSH terms: Diagnostic Tests, Routine/methods*
  13. Wong PF, Wong LP, AbuBakar S
    J Infect Public Health, 2020 Feb;13(2):193-198.
    PMID: 31405788 DOI: 10.1016/j.jiph.2019.07.012
    BACKGROUND: Delayed diagnosis of dengue cases with increased risk for severe disease could lead to poor disease outcome. To date there is no specific laboratory diagnostic test for severe dengue. This qualitative study explored expert views regarding current issues in diagnosing severe dengue, rationale for severe dengue-specific diagnostics, future prospects and features of potential diagnostics for severe dengue.

    METHODS: In-depth individual interviews with thematic saturation were conducted between May and July 2018. The data was analyzed using thematic analysis.

    RESULTS: Based on expert opinion, diagnosis of severe dengue is challenging as it depends on astute clinical interpretation of non-dengue-specific clinical and laboratory findings. A specific test that detects impending manifestation of severe dengue could 1) overcome failure in identifying severe disease for referral or admission, 2) facilitate timely and appropriate management of plasma leakage and bleeding, 3) overcome the lack of clinical expertise and laboratory diagnosis in rural health settings. The most important feature of any diagnostics for severe dengue is the point-of-care (POC) format where it can be performed at or near the bedside.

    CONCLUSION: The development of diagnostics to detect impending severe dengue is warranted to reduce the morbidity and mortality rates of dengue infection and it should be prioritized.

    Matched MeSH terms: Diagnostic Tests, Routine/methods
  14. Jackson AA, Lai PSM, Alias AM, Atiya N, Ramdzan SN, Abdul Malik TF, et al.
    J Infect Dev Ctries, 2019 03 31;13(3):219-226.
    PMID: 32040451 DOI: 10.3855/jidc.11089
    INTRODUCTION: Diagnosis and management of urinary tract infection (UTI) are complex, and do not always follow guidelines. The aim of this study was to determine adherence to the 2014 Malaysian Ministry of Health guidelines for managing suspected UTI in a Malaysian primary care setting.

    METHODOLOGY: We retrospectively reviewed computerized medical records of adults with suspected UTI between July-December 2016. Excluded were consultations misclassified by the search engine, duplicated records of the same patient, consultations for follow-up of suspected UTI, patients who were pregnant, catheterised, or who had a renal transplant. Records were reviewed by two primary care physicians and a clinical microbiologist.

    RESULTS: From 852 records, 366 consultations were a fresh episode of possible UTI. Most subjects were female (78.2%) with median age of 61.5 years. The major co-morbidities were hypertension (37.1%), prostatic enlargement in males (35.5%) and impaired renal function (31.1%). Symptoms were reported in 349 (95.4%) consultations. Antibiotics were prescribed in 307 (83.9%) consultations, which was appropriate in 227/307 (73.9%), where the subject had at least one symptom, and leucocytes were raised in urine full examination and microscopic examination (UFEME). In 73 (23.8%) consultations antibiotics were prescribed inappropriately, as the subjects were asymptomatic (14,4.6%), urine was clear (17,5.5%), or UFEME did not show raised leucocytes (42,13.7%). In 7 (2.3%) consultations appropriateness of antibiotics could not be determined as UFEME was not available.

    CONCLUSION: Several pitfalls contributed to suboptimal adherence to guidelines for diagnosis and management of suspected UTI. This illustrates the complexity of managing suspected UTI in older subjects with multiple co-morbidities.

    Matched MeSH terms: Diagnostic Tests, Routine/methods*
  15. Chong YM, Tan XH, Hooi PS, Lee LM, Sam IC, Chan YF
    J Med Virol, 2019 08;91(8):1562-1565.
    PMID: 31032971 DOI: 10.1002/jmv.25495
    Rapid diagnosis of influenza is important for early treatment and institution of control measures. In developing tropical countries such as Malaysia, influenza occurs all year round, but molecular assays and conventional techniques (such as immunofluorescence and culture) for diagnosis are not widely available. Rapid influenza diagnostic tests (RIDTs) may be useful in this setting. A total of 552 fresh respiratory specimens were assessed from patients with respiratory symptoms at a teaching hospital in Kuala Lumpur, Malaysia from November 2017 to March 2018. Two digital immunoassays (DIAs), STANDARD F Influenza A/B Fluorescence Immunoassay (STANDARD F) and Sofia Influenza A + B Fluorescence Immunoassay (Sofia) and one conventional RIDT (immunochromatographic assay), SD Bioline Influenza Ag A/B/A(H1N1) Pandemic rapid test kit (SD Bioline) were evaluated in comparison with a WHO-recommended reverse transcription quantitative PCR (RT-qPCR). Of the 552 samples, influenza A virus was detected in 47 (8.5%) and influenza B virus in 7 (1.3%). The digital immunoassays STANDARD F and Sofia had significantly higher overall sensitivity rates (71.7% and 70.6%, respectively) than the conventional RIDT SD Bioline and immunofluorescence/viral culture (55.8% and 52.8%, respectively). Sensitivity rates were higher for influenza A than influenza B, and specificity rates were uniformly high, ranging from 98% to 100%. Digital readout RIDTs can be used in tropical settings with year-round influenza if PCR is unavailable.
    Matched MeSH terms: Diagnostic Tests, Routine/methods*
  16. Mohd Amiruddin MN, Ang GY, Yu CY, Falero-Diaz G, Otero O, Reyes F, et al.
    J Microbiol Methods, 2020 09;176:106003.
    PMID: 32702386 DOI: 10.1016/j.mimet.2020.106003
    Mycobacterium tuberculosis (Mtb) is a pathogenic bacterium that causes tuberculosis (TB). This contagious disease remains a severe health problem in the world. The disease is transmitted via inhalation of airborne droplets carrying Mtb from TB patients. Early detection of the disease is vital to prevent transmission of the infection to people in close contact with the patients. To date, there is a need of a simple, rapid, sensitive and specific diagnostic test for TB. Previous studies showed the potential of Mtb 16 kDa antigen (Ag16) in TB diagnosis. In this study, lateral flow immunoassay, also called simple strip immunoassay or immunochromatographic test (ICT) for detection of Ag16 was developed (Mtb-strip) and assessed as a potential rapid TB diagnosis method. A monoclonal antibody against Ag16 was optimized as the capturing and detection antibody on the Mtb-strip. Parameters affecting the performance of the Mtb-strip were also optimized before a complete prototype was developed. Analytical sensitivity showed that Mtb-strip was capable to detect as low as 125 ng of purified Ag16. The analytical sensitivity of Mtb-strip suggests its potential usefulness in different clinical applications.
    Matched MeSH terms: Diagnostic Tests, Routine/methods*
  17. Foster D, Cox-Singh J, Mohamad DS, Krishna S, Chin PP, Singh B
    Malar J, 2014;13:60.
    PMID: 24548805 DOI: 10.1186/1475-2875-13-60
    Plasmodium knowlesi, a malaria parasite of Southeast Asian macaques, infects humans and can cause fatal malaria. It is difficult to diagnose by microscopy because of morphological similarity to Plasmodium malariae. Nested PCR assay is the most accurate method to distinguish P. knowlesi from other Plasmodium species but is not cost effective in resource-poor settings. Rapid diagnostic tests (RDTs) are recommended for settings where malaria is prevalent. In this study, the effectiveness of three RDTs in detecting P. knowlesi from fresh and frozen patient blood samples was evaluated.
    Matched MeSH terms: Diagnostic Tests, Routine/methods*
  18. Alareqi LM, Mahdy MA, Lau YL, Fong MY, Abdul-Ghani R, Ali AA, et al.
    Malar J, 2016 Jan 28;15:49.
    PMID: 26821911 DOI: 10.1186/s12936-016-1103-2
    Malaria is a public health threat in Yemen, with 149,451 cases being reported in 2013. Of these, Plasmodium falciparum represents 99%. Prompt diagnosis by light microscopy (LM) and rapid diagnostic tests (RTDs) is a key element in the national strategy of malaria control. The heterogeneous epidemiology of malaria in the country necessitates the field evaluation of the current diagnostic strategies, especially RDTs. Thus, the present study aimed to evaluate LM and an RDT, combining both P. falciparum histidine-rich protein-2 (PfHRP-2) and Plasmodium lactate dehydrogenase (pLDH), for falciparum malaria diagnosis and survey in a malaria-endemic area during the transmission season against nested polymerase chain reaction (PCR) as the reference method.
    Matched MeSH terms: Diagnostic Tests, Routine/methods*
  19. Selvarajah D, Naing C, Htet NH, Mak JW
    Malar J, 2020 Jun 19;19(1):211.
    PMID: 32560728 DOI: 10.1186/s12936-020-03283-9
    BACKGROUND: The global malaria decline has stalled and only a few countries are pushing towards pre-elimination. The aim of the malaria elimination phase is interruption of local transmission of a specified malaria parasite in a defined geographical area. New and improved screening tools and strategies are required for detection and management of very low-density parasitaemia in the field. The objective of this study was to synthesize evidence on the diagnostic accuracy of loop-mediated isothermal amplification (LAMP) test for the detection of malaria parasites among people living in endemic areas.

    METHODS: This study adhered to the Preferred Reporting Items for Systematic Reviews and Meta-Analysis for Diagnostic Test Accuracy (PRISMA-DTA) guideline. Relevant studies in the health-related electronic databases were searched. According to the criteria set for this study, eligible studies were identified. The quality of included studies was evaluated with the use of a quality assessment checklist. A summary performance estimates such as pooled sensitivity and specificity were stratified by type of LAMP. Bivariate model for data analyses was applied. Summary receiver operating characteristics plots were created to display the results of individual studies in a receiver operating characteristics space. Meta-regression analysis was performed to investigate the sources of heterogeneity among individual studies.

    RESULTS: Twenty-seven studies across 17 endemic countries were identified. The vast majority of studies were with unclear risk of bias in the selection of index test. Overall, the pooled test performances were high for Pan LAMP (sensitivity: 0.95, 95% CI 0.91 to 0.97; specificity: 0.98, 95% CI 0.95 to 0.99), Plasmodium falciparum (Pf) LAMP (sensitivity: 0.96, 95% CI 0.94 to 0.98; specificity: 0.99, 95% CI 0.96 to 1.00) or for Plasmodium vivax (Pv) LAMP from 6 studies (sensitivity: 0.98, 95% CI 0.92 to 0.99; specificity: 0.99, 95% CI 0.72 to 1.00). The area under the curve for Pan LAMP (0.99, 95% CI 0.98-1.00), Pf LAMP (0.99, 95% CI 0.97-0.99) and Pv LAMP was (1.00, 95% CI 0.98-1.00) indicated that the diagnostic performance of these tests were within the excellent accuracy range. Meta-regression analysis showed that sample size had the greatest impact on test performance, among other factors.

    CONCLUSIONS: The current findings suggest that LAMP-based assays are appropriate for detecting low-level malaria parasite infections in the field and would become valuable tools for malaria control and elimination programmes. Future well-designed larger sample studies on LAMP assessment in passive and active malaria surveillances that use PCR as the reference standard and provide sufficient data to construct 2 × 2 diagnostic table are needed.

    Matched MeSH terms: Diagnostic Tests, Routine/methods*
  20. Naing C, Htet NH, Aye SN, Aung HH, Tanner M, Whittaker MA
    Malar J, 2022 Feb 16;21(1):50.
    PMID: 35172833 DOI: 10.1186/s12936-022-04082-0
    BACKGROUND: Achieving malaria elimination requires the targeting of the human reservoir of infection, including those patients with asymptomatic infection. The objective was to synthesise evidence on the accuracy of the rapid-onsite diagnostic tests (RDTs) and microscopy for the detection of asymptomatic malaria as part of the surveillance activities in Asian countries.

    METHODS: This was a meta-analysis of diagnostic test accuracy. Relevant studies that evaluated the diagnostic performance of RDTs and microscopy for detection of asymptomatic malaria were searched in health-related electronic databases. The methodological quality of the studies included was assessed using the QUADAS-2 tool.

    RESULTS: Ten studies assessing RDT and/or microscopy were identified. The diagnostic accuracies in all these studies were verified by PCR. Overall, the pooled sensitivities of RDT, as well as microscopy for detection of any malaria parasites in asymptomatic participants, were low, while their pooled specificities were almost ideal. For the detection of Plasmodium falciparum, pooled sensitivity by RDT (59%, 95%CI:16-91%) or microscopy (55%, 95%CI: 25-82%) were almost comparable. For detection of Plasmodium vivax, pooled sensitivity of RDT (51%, 95% CI:7-94%) had also the comparable accuracy of microscopy (54%, 95%CI,11-92%). Of note are the wide range of sensitivity and specificity.

    CONCLUSION: The findings of this meta-analysis suggest that RDTs and microscopy have limited sensitivity and are inappropriate for the detection of asymptomatic Plasmodium infections. Other methods including a combination of PCR-based strategies, Loop-Mediated Isothermal Amplification (LAMP) technique must be considered to target these infections, in order to achieve malaria elimination. However, more data is needed for the wide acceptance and feasibility of these approaches. Studies to explore the role of asymptomatic and sub-patent infections in the transmission of malaria are of critical importance and are recommended.

    Matched MeSH terms: Diagnostic Tests, Routine/methods