  1. Bradley DA, Wong CS, Ng KH
    Appl Radiat Isot, 2000 9 26;53(4-5):691-7.
    PMID: 11003508
    For broad-beam soft X-ray sources, assessment of the quality of image produced by such units is made complex by the low penetration capabilities of the radiation. In the present study we have tested the utility of several types of test tool, some of which have been fabricated by us, as part of an effort to evaluate several key image defining parameters. These include the film characteristic, focal-spot size, image resolution and detail detectability. The two sources of X-rays used in present studies were the University of Malaya flash X-ray device (UMFX1) and a more conventional soft X-ray tube (Softex, Tokyo), the latter operating at peak accelerating potentials of 20 kVp. We have established, for thin objects, that both systems produce images of comparable quality and, in particular, objects can be resolved down to better than 45 microm.
    Matched MeSH terms: Radiographic Image Enhancement/methods*
  2. Gangeh MJ, Hanmandlu M, Bister M
    Biomed Sci Instrum, 2002;38:369-74.
    PMID: 12085634
    The specific texture on B-scan images is believed to be related to both ultrasound machine characteristics and tissue properties, i.e., the pathological states of the soft tissue. Therefore, for classification, features can be extracted with the use of image texture analysis techniques. In this paper a novel fuzzy approach for texture characterization is used for classification of normal liver and diffused liver diseases, here fatty liver, liver cirrhosis, and hepatitis are emphasized. The texture analysis techniques are diversified by the existence of several approaches. We propose fuzzy features for the analysis of the texture image. For this, a membership function is constructed to represent the effect of the neighboring pixels on the current pixel in a window. Using these membership function values, we find a feature by weighted average method for the current pixel. This is repeated for all pixels in the window treating each time one pixel as the current pixel. Using these fuzzy based features, we derive three descriptors: maximum, entropy, and energy as used in co-occurrence method, for each window.
    Matched MeSH terms: Image Enhancement/methods*
  3. Yap PT, Paramesran R
    IEEE Trans Pattern Anal Mach Intell, 2005 Dec;27(12):1996-2002.
    PMID: 16355666
    Legendre moments are continuous moments, hence, when applied to discrete-space images, numerical approximation is involved and error occurs. This paper proposes a method to compute the exact values of the moments by mathematically integrating the Legendre polynomials over the corresponding intervals of the image pixels. Experimental results show that the values obtained match those calculated theoretically, and the image reconstructed from these moments have lower error than that of the conventional methods for the same order. Although the same set of exact Legendre moments can be obtained indirectly from the set of geometric moments, the computation time taken is much longer than the proposed method.
    Matched MeSH terms: Image Enhancement/methods*
  4. Salih QA, Ramli AR, Mahmud R, Wirza R
    MedGenMed, 2005;7(2):1.
    PMID: 16369380
    Different approaches to gray and white matter measurements in magnetic resonance imaging (MRI) have been studied. For clinical use, the estimated values must be reliable and accurate when, unfortunately, many techniques fail on these criteria in an unrestricted clinical environment. A recent method for tissue clusterization in MRI analysis has the advantage of great simplicity, and it takes the account of partial volume effects. In this study, we will evaluate the intensity of MR sequences known as T1-weighted images in an axial sliced section. Intensity group clustering algorithms are proposed to achieve further diagnosis for brain MRI, which has been hardly studied. Subjective study has been suggested to evaluate the clustering group intensity in order to obtain the best diagnosis as well as better detection for the suspected cases. This technique makes use of image tissue biases of intensity value pixels to provide 2 regions of interest as techniques. Moreover, the original mathematic solution could still be used with a specific set of modern sequences. There are many advantages to generalize the solution, which give far more scope for application and greater accuracy.
    Matched MeSH terms: Image Enhancement/methods*
  5. Logeswaran R
    Med Biol Eng Comput, 2006 Aug;44(8):711-9.
    PMID: 16937213
    This paper proposes a detection scheme for identifying stones in the biliary tract of the body, which is examined using magnetic resonance cholangiopancreatography (MRCP), a sequence of magnetic resonance imaging targeted at the pancreatobiliary region of the abdomen. The scheme enhances the raw 2D thick slab MRCP images and extracts the biliary structure in the images using a segment-based region-growing approach. Detection of stones is scoped within this extracted structure, by highlighting possible stones. A trained feedforward artificial neural network uses selected features of size and average segment intensity as its input to detect possible stones in MRCP images and eliminate false stone-like objects. The proposed scheme achieved satisfactory results in tests of clinical MRCP thick slab images, indicating potential for implementation in computer-aided diagnosis systems for the liver.
    Matched MeSH terms: Radiographic Image Enhancement/methods
  6. Jamal N, Ng KH, Looi LM, McLean D, Zulfiqar A, Tan SP, et al.
    Phys Med Biol, 2006 Nov 21;51(22):5843-57.
    PMID: 17068368
    We describe a semi-automated technique for the quantitative assessment of breast density from digitized mammograms in comparison with patterns suggested by Tabar. It was developed using the MATLAB-based graphical user interface applications. It is based on an interactive thresholding method, after a short automated method that shows the fibroglandular tissue area, breast area and breast density each time new thresholds are placed on the image. The breast density is taken as a percentage of the fibroglandular tissue to the breast tissue areas. It was tested in four different ways, namely by examining: (i) correlation of the quantitative assessment results with subjective classification, (ii) classification performance using the quantitative assessment technique, (iii) interobserver agreement and (iv) intraobserver agreement. The results of the quantitative assessment correlated well (r2 = 0.92) with the subjective Tabar patterns classified by the radiologist (correctly classified 83% of digitized mammograms). The average kappa coefficient for the agreement between the readers was 0.63. This indicated moderate agreement between the three observers in classifying breast density using the quantitative assessment technique. The kappa coefficient of 0.75 for intraobserver agreement reflected good agreement between two sets of readings. The technique may be useful as a supplement to the radiologist's assessment in classifying mammograms into Tabar's pattern associated with breast cancer risk.
    Matched MeSH terms: Radiographic Image Enhancement/methods*
  7. Abdullah MZ, Yin W, Bilal M, Armitage DW, Mackin R, Peyton AJ
    Rev Sci Instrum, 2007 Aug;78(8):084703.
    PMID: 17764343
    This article addresses time-domain ultrawide band (UWB) electromagnetic tomography for reconstructing the unknown spatial characteristic of an object from observations of the arrivals of short electromagnetic (EM) pulses. Here, the determination of the first peak arrival of the EM traces constitutes the forward problem, and the inverse problem aims to reconstruct the EM property distribution of the media. In this article, the finite-difference time-domain method implementing a perfectly matched layer is used to solve the forward problem from which the system sensitivity maps are determined. Image reconstruction is based on the combination of a linearized update and regularized Landweber minimization algorithm. Experimental data from a laboratory UWB system using targets of different contrasts, sizes, and shapes in an aqueous media are presented. The results show that this technique can accurately detect and locate unknown targets in spite of the presence of significant levels of noise in the data.
    Matched MeSH terms: Image Enhancement/methods*
  8. Choong MK, Logeswaran R, Bister M
    Int J Med Inform, 2007 Sep;76(9):646-54.
    PMID: 16769242
    This paper concentrates on strategies for less costly handling of medical images. Aspects of digitization using conventional digital cameras, lossy compression with good diagnostic quality, and visualization through less costly monitors are discussed.
    Matched MeSH terms: Radiographic Image Enhancement/methods*
  9. Vattoth S, Cherian J, Pandey T
    Magn Reson Imaging, 2007 Oct;25(8):1227-31.
    PMID: 17442526
    Magnetic resonance angiographic evaluation of the intracranial vasculature has been predominantly carried out using conventional angiographic techniques such as time of flight and phase contrast sequences. These techniques have good spatial resolution but lack temporal resolution. Newer faster angiographic techniques have been developed to circumvent this limitation. Elliptical centric time-resolved imaging of contrast kinetics (EC-TRICKS) is one such technique which has combined the use of elliptical centric ordering of the k-space with multiphase 3D digital subtraction MR angiogram (MRA) to achieve excellent temporal resolution of the arterial and venous circulations. Its applications have been mainly in the peripheral vasculature. We report the use of this technique in a case of a high-flow, direct carotid-cavernous fistula to demonstrate its potential in intracranial MR angiography.
    Matched MeSH terms: Image Enhancement/methods*
  10. Ahmad Fadzil MH, Izhar LI, Venkatachalam PA, Karunakar TV
    J Med Eng Technol, 2007 Nov-Dec;31(6):435-42.
    PMID: 17994417 DOI: 10.1080/03091900601111201
    Information about retinal vasculature morphology is used in grading the severity and progression of diabetic retinopathy. An image analysis system can help ophthalmologists make accurate and efficient diagnoses. This paper presents the development of an image processing algorithm for detecting and reconstructing retinal vasculature. The detection of the vascular structure is achieved by image enhancement using contrast limited adaptive histogram equalization followed by the extraction of the vessels using bottom-hat morphological transformation. For reconstruction of the complete retinal vasculature, a region growing technique based on first-order Gaussian derivative is developed. The technique incorporates both gradient magnitude change and average intensity as the homogeneity criteria that enable the process to adapt to intensity changes and intensity spread over the vasculature region. The reconstruction technique reduces the required number of seeds to near optimal for the region growing process. It also overcomes poor performance of current seed-based methods, especially with low and inconsistent contrast images as normally seen in vasculature regions of fundus images. Simulations of the algorithm on 20 test images from the DRIVE database show that it outperforms many other published methods and achieved an accuracy range (ability to detect both vessel and non-vessel pixels) of 0.91 - 0.95, a sensitivity range (ability to detect vessel pixels) of 0.91 - 0.95 and a specificity range (ability to detect non-vessel pixels) of 0.88 - 0.94.
    Matched MeSH terms: Image Enhancement/methods*
  11. Ihtatho D, Fadzil MH, Affandi AM, Hussein SH
    PMID: 18002738
    Psoriasis is a skin disorder which is caused by genetic fault. There is no cure for psoriasis, however, there are many treatment modalities to help control the disease. To evaluate treatment efficacy, PASI (Psoriasis Area and Severity Index) which is the current gold standard method is used to measure psoriasis severity by evaluating the area, erythema, scaliness and thickness of the plaques. However, the calculation of PASI can be tedious and subjective. In this work, we develop a computer vision method that determines one of the PASI parameter, the lesion area. The method isolates healthy (or healed) skin areas from lesion areas by analyzing the hue and chroma information in the CIE L*a*b* colour space. Centroids of healthy skin and psoriasis in the hue-chroma space are determined from selected sample. Euclidean distance of all pixels from each centroid is calculated. Each pixel is assigned to the class with minimum Euclidean distance. The study involves patients from three different ethnic origins having different skin tones. Results obtained show that the proposed method is comparable to the dermatologist visual approach.
    Matched MeSH terms: Image Enhancement/methods
  12. Nugroho H, Fadzil MH, Yap VV, Norashikin S, Suraiya HH
    PMID: 18002737
    In this paper, we describe an image processing scheme to analyze and determine areas of skin that have undergone repigmentation in particular, during the treatment of vitiligo. In vitiligo cases, areas of skin become pale or white due to the lack of skin pigment called melanin. Vitiligo treatment causes skin repigmentation resulting in a normal skin color. However, it is difficult to determine and quantify the amount of repigmentation visually during treatment because the repigmentation progress is slow and moreover changes in skin color can only be discerned over a longer time frame typically 6 months. Here, we develop a digital image analysis scheme that can identify and determine vitiligo skin areas and repigmentation progression on a shorter time period. The technique is based on principal component analysis and independent component analysis which converts the RGB skin image into a skin image that represent skin areas due to melanin and haemoglobin only, followed by segmentation process. Vitiligo skin lesions are identified as skin areas that lack melanin (non-melanin areas). In the initial studies of 4 patients, the method has been able to quantify repigmentation in vitiligo lesion. Hence it is now possible to determine repigmentation progression objectively and treatment efficacy on a shorter time cycle.
    Matched MeSH terms: Image Enhancement/methods
  13. Kamel NS, Sayeed S, Ellis GA
    IEEE Trans Pattern Anal Mach Intell, 2008 Jun;30(6):1109-13.
    PMID: 18421114 DOI: 10.1109/TPAMI.2008.32
    Utilizing the multiple degrees of freedom offered by the data glove for each finger and the hand, a novel on-line signature verification system using the Singular Value Decomposition (SVD) numerical tool for signature classification and verification is presented. The proposed technique is based on the Singular Value Decomposition in finding r singular vectors sensing the maximal energy of glove data matrix A, called principal subspace, so the effective dimensionality of A can be reduced. Having modeled the data glove signature through its r-principal subspace, signature authentication is performed by finding the angles between the different subspaces. A demonstration of the data glove is presented as an effective high-bandwidth data entry device for signature verification. This SVD-based signature verification technique is tested and its performance is shown to be able to recognize forgery signatures with a false acceptance rate of less than 1.2%.
    Matched MeSH terms: Image Enhancement/methods
  14. Al-Azzawi N, Sakim HA, Abdullah AK, Ibrahim H
    PMID: 19965249 DOI: 10.1109/IEMBS.2009.5335180
    We present an efficient method for the fusion of medical captured images using different modalities that enhances the original images and combines the complementary information of the various modalities. The contourlet transform has mainly been employed as a fusion technique for images obtained from equal or different modalities. The limitation of directional information of dual-tree complex wavelet (DT-CWT) is rectified in dual-tree complex contourlet transform (DT-CCT) by incorporating directional filter banks (DFB) into the DT-CWT. The DT-CCT produces images with improved contours and textures, while the property of shift invariance is retained. To improve the fused image quality, we propose a new method for fusion rules based on principle component analysis (PCA) which depend on frequency component of DT-CCT coefficients (contourlet domain). For low frequency components, PCA method is adopted and for high frequency components, the salient features are picked up based on local energy. The final fusion image is obtained by directly applying inverse dual tree complex contourlet transform (IDT-CCT) to the fused low and high frequency components. The experimental results showed that the proposed method produces fixed image with extensive features on multimodality.
    Matched MeSH terms: Image Enhancement/methods*
  15. Meselhy Eltoukhy M, Faye I, Belhaouari Samir B
    Comput Biol Med, 2010 Apr;40(4):384-91.
    PMID: 20163793 DOI: 10.1016/j.compbiomed.2010.02.002
    This paper presents a comparative study between wavelet and curvelet transform for breast cancer diagnosis in digital mammogram. Using multiresolution analysis, mammogram images are decomposed into different resolution levels, which are sensitive to different frequency bands. A set of the biggest coefficients from each decomposition level is extracted. Then a supervised classifier system based on Euclidian distance is constructed. The performance of the classifier is evaluated using a 2 x 5-fold cross validation followed by a statistical analysis. The experimental results suggest that curvelet transform outperforms wavelet transform and the difference is statistically significant.
    Matched MeSH terms: Image Enhancement/methods*
  16. Eltoukhy MM, Faye I, Samir BB
    Comput Med Imaging Graph, 2010 Jun;34(4):269-76.
    PMID: 20004076 DOI: 10.1016/j.compmedimag.2009.11.002
    This paper presents an approach for breast cancer diagnosis in digital mammogram using curvelet transform. After decomposing the mammogram images in curvelet basis, a special set of the biggest coefficients is extracted as feature vector. The Euclidean distance is then used to construct a supervised classifier. The experimental results gave a 98.59% classification accuracy rate, which indicate that curvelet transformation is a promising tool for analysis and classification of digital mammograms.
    Matched MeSH terms: Radiographic Image Enhancement/methods*
  17. Aminah M, Ng KH, Abdullah BJ, Jamal N
    Australas Phys Eng Sci Med, 2010 Dec;33(4):329-34.
    PMID: 20938762 DOI: 10.1007/s13246-010-0035-3
    The performance of a digital mammography system (Siemens Mammomat Novation) using different target/filter combinations and tube voltage has been assessed. The objective of this study is to optimize beam quality selection based on contrast-to-noise ratio (CNR) and mean glandular dose (MGD). Three composition of breast were studied with composition of glandular/adipose of 30/70, 50/50, and 70/30. CNR was measured using 2, 4 and 6 cm-thick simulated breast phantoms with an aluminium sheet of 0.1 mm thickness placed on top of the phantom. Three target/filter combinations, namely molybdenum/molybdenum (Mo/Mo), molybdenum/rhodium (Mo/Rh) and tungsten/rhodium (W/Rh) with various tube voltage and mAs were tested. MGD was measured for each exposure. For 50/50 breast composition, Mo/Rh combination with tube voltage 26 kVp is optimal for 2 cm-thick breast. W/Rh combination with tube voltage 27 and 28 kVp are optimal for 4 and 6 cm-thick breast, respectively. For both 30/70 and 70/30 breast composition, W/Rh combination is optimal with tube voltage 25, 26 and 27 kVp, respectively. From our study it was shown that there are potential of dose reduction up to 11% for a set CNR of 3.0 by using beam quality other than that are determined by AEC selection. Under the constraint of lowest MGD, for a particular breast composition, calcification detection is optimized by using a softer X-ray beam for thin breast and harder X-ray beam for thick breast. These experimental results also indicate that for breast with high fibroglandular tissues (70/30), the use of higher beam quality does not always increase calcification detection due to additional structured noise caused by the fibroglandular tissues itself.
    Matched MeSH terms: Radiographic Image Enhancement/methods*
  18. Saleh MD, Eswaran C, Mueen A
    J Digit Imaging, 2011 Aug;24(4):564-72.
    PMID: 20524139 DOI: 10.1007/s10278-010-9302-9
    This paper focuses on the detection of retinal blood vessels which play a vital role in reducing the proliferative diabetic retinopathy and for preventing the loss of visual capability. The proposed algorithm which takes advantage of the powerful preprocessing techniques such as the contrast enhancement and thresholding offers an automated segmentation procedure for retinal blood vessels. To evaluate the performance of the new algorithm, experiments are conducted on 40 images collected from DRIVE database. The results show that the proposed algorithm performs better than the other known algorithms in terms of accuracy. Furthermore, the proposed algorithm being simple and easy to implement, is best suited for fast processing applications.
    Matched MeSH terms: Image Enhancement/methods*
  19. Riyadi S, Mustafa MM, Hussain A, Maskon O, Nor IF
    Adv Exp Med Biol, 2011;696:461-9.
    PMID: 21431586 DOI: 10.1007/978-1-4419-7046-6_46
    Left ventricular motion estimation is very important for diagnosing cardiac abnormality. One of the popular techniques, optical flow technique, promises useful results for motion quantification. However, optical flow technique often failed to provide smooth vector field due to the complexity of cardiac motion and the presence of speckle noise. This chapter proposed a new filtering technique, called quasi-Gaussian discrete cosine transform (QGDCT)-based filter, to enhance the optical flow field for myocardial motion estimation. Even though Gaussian filter and DCT concept have been implemented in other previous researches, this filter introduces a different approach of Gaussian filter model based on high frequency properties of cosine function. The QGDCT is a customized quasi discrete Gaussian filter in which its coefficients are derived from a selected two-dimensional DCT. This filter was implemented before and after the computation of optical flow to reduce the speckle noise and to improve the flow field smoothness, respectively. The algorithm was first validated on synthetic echocardiography image that simulates a contracting myocardium motion. Subsequently, this method was also implemented on clinical echocardiography images. To evaluate the performance of the technique, several quantitative measurements such as magnitude error, angular error, and standard error of measurement are computed and analyzed. The final motion estimation results were in good agreement with the physician manual interpretation.
    Matched MeSH terms: Image Enhancement/methods
  20. Pasha MF, Hong KS, Rajeswari M
    PMID: 22255503 DOI: 10.1109/IEMBS.2011.6091280
    Automating the detection of lesions in liver CT scans requires a high performance and robust solution. With CT-scan start to become the norm in emergency department, the need for a fast and efficient liver lesions detection method is arising. In this paper, we propose a fast and evolvable method to profile the features of pre-segmented healthy liver and use it to detect the presence of liver lesions in emergency scenario. Our preliminary experiment with the MICCAI 2007 grand challenge datasets shows promising results of a fast training time, ability to evolve the produced healthy liver profiles, and accurate detection of the liver lesions. Lastly, the future work directions are also presented.
    Matched MeSH terms: Radiographic Image Enhancement/methods