Displaying publications 1 - 20 of 28 in total

Abstract:
Sort:
  1. Zaman ZK, Ung NM, Malik RA, Ho GF, Phua VC, Jamalludin Z, et al.
    Phys Med, 2014 Dec;30(8):980-4.
    PMID: 25086486 DOI: 10.1016/j.ejmp.2014.07.002
    Cobalt-60 (Co-60) is a relatively new source for the application of high-dose rate (HDR) brachytherapy. Radiation dose to the rectum is often a limiting factor in achieving the full prescribed dose to the target during brachytherapy of cervical cancer. The aim of this study was to measure radiation doses to the rectum in-vivo during HDR Co-60 brachytherapy. A total of eleven HDR brachytherapy treatments of cervical cancer were recruited in this study. A series of diodes incorporated in a rectal probe was inserted into the patient's rectum during each brachytherapy procedure. Real-time measured rectal doses were compared to calculated doses by the treatment planning system (TPS). The differences between calculated and measured dose ranged from 8.5% to 41.2%. This corresponds to absolute dose differences ranging from 0.3 Gy to 1.5 Gy. A linear relationship was observed between calculated and measured doses with linear regression R(2) value of 0.88, indicating close association between the measured and calculated doses. In general, absorbed doses for the rectum as calculated by TPS were observed to be higher than the doses measured using the diode probe. In-vivo dosimetry is an important quality assurance method for HDR brachytherapy of cervical cancer. It provides information that can contribute to the reduction of errors and discrepancies in dose delivery. Our study has shown that in-vivo dosimetry is feasible and can be performed to estimate the dose to the rectum during HDR brachytherapy using Co-60.
    Matched MeSH terms: Radiotherapy Planning, Computer-Assisted/methods
  2. Yu L, Tang TLS, Cassim N, Livingstone A, Cassidy D, Kairn T, et al.
    J Appl Clin Med Phys, 2019 Nov;20(11):189-198.
    PMID: 31613053 DOI: 10.1002/acm2.12726
    PURPOSE: Gamma evaluation is the most commonly used technique for comparison of dose distributions for patient-specific pretreatment quality assurance in radiation therapy. Alternative dose comparison techniques have been developed but not widely implemented. This study aimed to compare and evaluate the performance of several previously published alternatives to the gamma evaluation technique, by systematically evaluating a large number of patient-specific quality assurance results.

    METHODS: The agreement indices (or pass rates) for global and local gamma evaluation, maximum allowed dose difference (MADD) and divide and conquer (D&C) techniques were calculated using a selection of acceptance criteria for 429 patient-specific pretreatment quality assurance measurements. Regression analysis was used to quantify the similarity of behavior of each technique, to determine whether possible variations in sensitivity might be present.

    RESULTS: The results demonstrated that the behavior of D&C gamma analysis and MADD box analysis differs from any other dose comparison techniques, whereas MADD gamma analysis exhibits similar performance to the standard global gamma analysis. Local gamma analysis had the least variation in behavior with criteria selection. Agreement indices calculated for 2%/2 mm and 2%/3 mm, and 3%/2 mm and 3%/3 mm were correlated for most comparison techniques.

    CONCLUSION: Radiation oncology treatment centers looking to compare between different dose comparison techniques, criteria or lower dose thresholds may apply the results of this study to estimate the expected change in calculated agreement indices and possible variation in sensitivity to delivery dose errors.

    Matched MeSH terms: Radiotherapy Planning, Computer-Assisted/methods*
  3. Yap LM, Jamalludin Z, Ng AH, Ung NM
    Phys Eng Sci Med, 2023 Sep;46(3):1331-1340.
    PMID: 37470929 DOI: 10.1007/s13246-023-01303-x
    The survey is to assess the current state of adaptive radiation therapy (ART) for head and neck (H&N) cases among radiotherapy centers in Malaysia and to identify any implementation limitations. An online questionnaire was sent to all radiotherapy centers in Malaysia. The 24-question questionnaire consists of general information about the center, ART practices, and limitations faced in implementing ART. 28 out of 36 radiotherapy centers responded, resulting in an overall response rate of 78%. About 52% of the responding centers rescanned and replanned less than 5% of their H&N patients. The majority (88.9%) of the respondents reported the use Cone Beam Computed Tomography alone or in combination with other modalities to trigger the ART process. The main reasons cited for adopting ART were weight loss, changes in the immobilization fitting, and anatomical variation. The adaptation process typically occurred during week 3 or week 4 of treatment. More than half of the respondents require three days or more from re-simulation to starting a new treatment plan. Both target and organ at risk delineation on new planning CT relied heavily on manual delineation by physicians and physicists, respectively. All centers perform patient-specific quality assurance for their new adaptive plans. Two main limitations in implementing ART are "limited financial resources or equipment" and "limitation on technical knowledge". There is a need for a common consensus to standardize the practice of ART and address these limitations to improve the implementation of ART in Malaysia.
    Matched MeSH terms: Radiotherapy Planning, Computer-Assisted/methods
  4. Yahya N, Ebert MA, Bulsara M, Haworth A, Kearvell R, Foo K, et al.
    Radiat Oncol, 2014;9:282.
    PMID: 25498565 DOI: 10.1186/s13014-014-0282-7
    To assess the impact of incremental modifications of treatment planning and delivery technique, as well as patient anatomical factors, on late gastrointestinal toxicity using data from the TROG 03.04 RADAR prostate radiotherapy trial.
    Matched MeSH terms: Radiotherapy Planning, Computer-Assisted/methods*
  5. Yahya N, Ebert MA, Bulsara M, Kennedy A, Joseph DJ, Denham JW
    Radiother Oncol, 2016 08;120(2):339-45.
    PMID: 27370204 DOI: 10.1016/j.radonc.2016.05.010
    BACKGROUND AND PURPOSE: Most predictive models are not sufficiently validated for prospective use. We performed independent external validation of published predictive models for urinary dysfunctions following radiotherapy of the prostate.

    MATERIALS/METHODS: Multivariable models developed to predict atomised and generalised urinary symptoms, both acute and late, were considered for validation using a dataset representing 754 participants from the TROG 03.04-RADAR trial. Endpoints and features were harmonised to match the predictive models. The overall performance, calibration and discrimination were assessed.

    RESULTS: 14 models from four publications were validated. The discrimination of the predictive models in an independent external validation cohort, measured using the area under the receiver operating characteristic (ROC) curve, ranged from 0.473 to 0.695, generally lower than in internal validation. 4 models had ROC >0.6. Shrinkage was required for all predictive models' coefficients ranging from -0.309 (prediction probability was inverse to observed proportion) to 0.823. Predictive models which include baseline symptoms as a feature produced the highest discrimination. Two models produced a predicted probability of 0 and 1 for all patients.

    CONCLUSIONS: Predictive models vary in performance and transferability illustrating the need for improvements in model development and reporting. Several models showed reasonable potential but efforts should be increased to improve performance. Baseline symptoms should always be considered as potential features for predictive models.

    Matched MeSH terms: Radiotherapy Planning, Computer-Assisted/methods*
  6. Yahya N, Ebert MA, House MJ, Kennedy A, Matthews J, Joseph DJ, et al.
    Int J Radiat Oncol Biol Phys, 2017 02 01;97(2):420-426.
    PMID: 28068247 DOI: 10.1016/j.ijrobp.2016.10.024
    PURPOSE: We assessed the association of the spatial distribution of dose to the bladder surface, described using dose-surface maps, with the risk of urinary dysfunction.

    METHODS AND MATERIALS: The bladder dose-surface maps of 754 participants from the TROG 03.04-RADAR trial were generated from the volumetric data by virtually cutting the bladder at the sagittal slice, intersecting the bladder center-of-mass through to the bladder posterior and projecting the dose information on a 2-dimensional plane. Pixelwise dose comparisons were performed between patients with and without symptoms (dysuria, hematuria, incontinence, and an International Prostate Symptom Score increase of ≥10 [ΔIPSS10]). The results with and without permutation-based multiple-comparison adjustments are reported. The pixelwise multivariate analysis findings (peak-event model for dysuria, hematuria, and ΔIPSS10; event-count model for incontinence), with adjustments for clinical factors, are also reported.

    RESULTS: The associations of the spatially specific dose measures to urinary dysfunction were dependent on the presence of specific symptoms. The doses received by the anteroinferior and, to lesser extent, posterosuperior surface of the bladder had the strongest relationship with the incidence of dysuria, hematuria, and ΔIPSS10, both with and without adjustment for clinical factors. For the doses to the posteroinferior region corresponding to the area of the trigone, the only symptom with significance was incontinence.

    CONCLUSIONS: A spatially variable response of the bladder surface to the dose was found for symptoms of urinary dysfunction. Limiting the dose extending anteriorly might help reduce the risk of urinary dysfunction.

    Matched MeSH terms: Radiotherapy Planning, Computer-Assisted
  7. Sim GS, Wong JH, Ng KH
    J Appl Clin Med Phys, 2013 Jul 08;14(4):4182.
    PMID: 23835383 DOI: 10.1120/jacmp.v14i4.4182
    Radiochromic and radiographic films are widely used for radiation dosimetry due to the advantage of high spatial resolution and two-dimensional dose measurement. Different types of scanners, including various models of flatbed scanners, have been used as part of the dosimetry readout procedure. This paper focuses on the characterization of the EBT2 film response in combination with a Microtek ScanMaker 9800XL scanner and the subsequent use in the dosimetric verification of a 3D conformal radiotherapy treatment. The film reproducibility and scanner uniformity of the Microtek ScanMaker 9800XL was studied. A three-field 3D conformal radiotherapy treatment was planned on an anthropomorphic phantom and EBT2 film measurements were carried out to verify the treatment. The interfilm reproducibility was found to be 0.25%. Over a period of three months, the films darkened by 1%. The scanner reproducibility was ± 2% and a nonuniformity was ±1.9% along the direction perpendicular to the scan direction. EBT2 measurements showed an underdose of 6.2% at high-dose region compared to TPS predicted dose. This may be due to the inability of the treatment planning system to predict the correct dose distribution in the presence of tissue inhomogeneities and the uncertainty of the scanner reproducibility and uniformity. The use of EBT2 film in conjunction with the axial CT image of the anthropomorphic phantom allows the evaluation of the anatomical location of dose discrepancies between the EBT2 measured dose distribution and TPS predicted dose distribution.
    Matched MeSH terms: Radiotherapy Planning, Computer-Assisted/standards*
  8. Samat SB, Evans CJ, Kadni T, Dolah MT
    Br J Radiol, 2000 Aug;73(872):867-77.
    PMID: 11026863
    A cylindrical gamma-ray 60Co source of activity alpha is predicted to produce an exposure rate X at a distance d in vacuum, given by X = gamma(T)(alpha/d2), where gamma(T) is the specific gamma-ray constant. It has been documented that this formula may be used to approximate X with an accuracy of 1% from a source of length l, provided that d/l > or = 5. It is shown that the formula is accurate to 0.1% under these conditions, provided that the distance is measured from the centre of the source. When absorption in the source and scattering in the collimator are considered, the position of the origin d = 0 can shift by a distance of the order of centimetres. Absorption in air between the source and the ionization chamber adds an exponential factor to the formula. It is shown that even when these modifications are included the discrepancy in the results, although generally less than 1%, is still large compared with the measurement errors. Some suggestions are made for the origin of this discrepancy.
    Matched MeSH terms: Radiotherapy Planning, Computer-Assisted/methods*
  9. Sabbaghizadeh R, Shamsudin R, Deyhimihaghighi N, Sedghi A
    PLoS One, 2017;12(1):e0168737.
    PMID: 28060829 DOI: 10.1371/journal.pone.0168737
    In the present study, the normoxic polyacrylamide gelatin and tetrakis hydroxy methyl phosphoniun chloride (PAGAT) polymer gel dosimeters were synthesized with and without the presence of silver (Ag) nanoparticles. The amount of Ag nanoparticles varied from 1 to 3 ml with concentration 3.14 g/l, thus forming two types of PAGAT polymer gel dosimeters before irradiating them with 6 to 25 Gy produced by 1.25-MeV 60Co gamma rays. In this range, the predominant gamma ray interaction with matter is by Compton scattering effect, as the photoelectric absorption effect diminishes. MRI was employed when evaluating the polymerization of the dosimeters and the gray scale of the MRI film was determined via an optical densitometer. Subsequent analyses of optical densities revealed that the extent of polymerization increased with the increase in the absorbed dose, while the increase of penetration depth within the dosimeters has a reverse effect. Moreover, a significant increase in the optical density-dose response (11.82%) was noted for dosimeters containing 2 ml Ag nanoparticles.
    Matched MeSH terms: Radiotherapy Planning, Computer-Assisted
  10. Rassiah P, Ng KH, DeWerd LA, Kunugi K
    Australas Phys Eng Sci Med, 2004 Mar;27(1):25-9.
    PMID: 15156705
    A thermoluminescent dosimetry (TLD) postal dose inter-comparison was carried out amongst radiotherapy centres in Malaysia. The aim of this TLD inter-comparison was to compare the uniformity involved in the measurement of absorbed dose among the participating centres. A set of 5 TLD chips placed within acrylic trays were mailed to all participating centres for irradiation to an absorbed dose to water of 2 Gy. Measurements were made for 6 MV and 60Co photon beams. Results show an agreement of +/- 5% for all but three radiotherapy centres. The ratios of the TLD readings to that of the reference centre are comparable with other national/regional dose inter-comparisons. The importance of a proper ongoing quality assurance program is essential in maintaining the consistency and uniformity of doses delivered.
    Matched MeSH terms: Radiotherapy Planning, Computer-Assisted/standards*
  11. Phua Chee Ee V, Tan BS, Tan AL, Eng KY, Ng BS, Ung NM
    Asian Pac J Cancer Prev, 2013;14(4):2243-8.
    PMID: 23725120
    BACKGROUND: To compare the dosimetric coverage of target volumes and organs at risk in the radical treatment of nasopharyngeal carcinoma (NPC) between intensity-modulated radiotherapy (IMRT) and three- dimensional conformal radiotherapy (3DCRT).

    MATERIALS AND METHODS: Data from 10 consecutive patients treated with IMRT from June-October 2011 in Penang General Hospital were collected retrospectively for analysis. For each patient, dose volume histograms were generated for both the IMRT and 3DCRT plans using a total dose of 70Gy. Comparison of the plans was accomplished by comparing the target volume coverage (5 measures) and sparing of organs at risk (17 organs) for each patient using both IMRT and 3DCRT. The means of each comparison target volume coverage measures and organs at risk measures were obtained and tested for statistical significance using the paired Student t-test.

    RESULTS: All 5 measures for target volume coverage showed marked dosimetric superiority of IMRT over 3DCRT. V70 and V66.5 for PTV70 showed an absolute improvement of 39.3% and 24.1% respectively. V59.4 and V56.4 for PTV59.4 showed advantages of 18.4% and 16.4%. Moreover, the mean PTV70 dose revealed a 5.1 Gy higher dose with IMRT. Only 4 out of 17 organs at risk showed statistically significant difference in their means which were clinically meaningful between the IMRT and 3DCRT techniques. IMRT was superior in sparing the spinal cord (less 5.8Gy), V30 of right parotid (less 14.3%) and V30 of the left parotid (less 13.1%). The V55 of the left cochlea was lower with 3DCRT (less 44.3%).

    CONCLUSIONS: IMRT is superior to 3DCRT due to its dosimetric advantage in target volume coverage while delivering acceptable doses to organs at risk. A total dose of 70Gy with IMRT should be considered as a standard of care for radical treatment of NPC.

    Matched MeSH terms: Radiotherapy Planning, Computer-Assisted*
  12. Phua CE, Ung NM, Tan BS, Tan AL, Eng KY, Ng BS
    Asian Pac J Cancer Prev, 2012;13(12):6133-7.
    PMID: 23464418
    PURPOSE: To study the effect of bolus versus no bolus in the coverage of the nodal tumour volume with intensity-modulated radiotherapy (IMRT) for the treatment of nasopharyngeal carcinoma (NPC).

    METHODS AND MATERIALS: This retrospective study used data from 5 consecutive patients with NPC who were treated with bolus for large neck nodes using IMRT from November 2011-January 2012 in our institute. All these patients were treated radically with IMRT according to our institution's protocol. Re-planning with IMRT without bolus for these patients with exactly the same target volumes were done for comparison. Comparison of the plans was done by comparing the V70 of PTV70-N, V66.5 of PTV70-N, V65.1 of PTV70-N and the surface dose of the PTV70-N.

    RESULTS: The mean size of the largest diameter of the enlarged lymph nodes for the 5 patients was 3.9 cm. The mean distance of the GTV-N to the skin surface was 0.6 cm. The mean V70 of PTV70-N for the 5 patients showed an absolute advantage of 10.8% (92.4% vs. 81.6%) for the plan with bolus while the V66.5 of PTV70-N had an advantage of 8.1% (97.0% vs. 88.9%). The mean V65.1 also had an advantage of 7.1% (97.6% vs. 90.5%). The mean surface dose for the PTV70-N was also much higher at 61.1 Gy for the plans with bolus compared to only 23.5 Gy for the plans without bolus.

    CONCLUSION: Neck node bolus technique should be strongly considered in the treatment of NPC with enlarged lymph nodes treated with IMRT. It yields a superior dosimetry compared to non-bolus plans with acceptable skin toxicity.

    Matched MeSH terms: Radiotherapy Planning, Computer-Assisted*
  13. Martin CJ, Kron T, Vassileva J, Wood TJ, Joyce C, Ung NM, et al.
    Phys Med, 2021 Oct;90:53-65.
    PMID: 34562809 DOI: 10.1016/j.ejmp.2021.09.004
    Improvements in delivery of radiation dose to target tissues in radiotherapy have increased the need for better image quality and led to a higher frequency of imaging patients. Imaging for treatment planning extends to function and motion assessment and devices are incorporated into medical linear accelerators (linacs) so that regions of tissue can be imaged at time of treatment delivery to ensure dose distributions are delivered as accurately as possible. A survey of imaging in 97 radiotherapy centres in nine countries on six continents has been undertaken with an on-line questionnaire administered through the International Commission on Radiological Protection mentorship programme to provide a snapshot of imaging practices. Responses show that all centres use CT for planning treatments and many utilise additional information from magnetic resonance imaging and positron emission tomography scans. Most centres have kV cone beam CT attached to at least some linacs and use this for the majority of treatment fractions. The imaging options available declined with the human development index (HDI) of the country, and the frequency of imaging during treatment depended more on country than treatment site with countries having lower HDIs imaging less frequently. The country with the lowest HDI had few kV imaging facilities and relied on MV planar imaging intermittently during treatment. Imaging protocols supplied by vendors are used in most centres and under half adapt exposure conditions to individual patients. Recording of patient doses, a knowledge of which is important in optimisation of imaging protocols, was limited primarily to European countries.
    Matched MeSH terms: Radiotherapy Planning, Computer-Assisted
  14. Leong CO, Lim E, Tan LK, Abdul Aziz YF, Sridhar GS, Socrates D, et al.
    Magn Reson Med, 2019 02;81(2):1385-1398.
    PMID: 30230606 DOI: 10.1002/mrm.27486
    PURPOSE: To evaluate a 2D-4D registration-cum-segmentation framework for the delineation of left ventricle (LV) in late gadolinium enhanced (LGE) MRI and for the localization of infarcts in patient-specific 3D LV models.

    METHODS: A 3-step framework was proposed, consisting of: (1) 3D LV model reconstruction from motion-corrected 4D cine-MRI; (2) Registration of 2D LGE-MRI with 4D cine-MRI; (3) LV contour extraction from the intersection of LGE slices with the LV model. The framework was evaluated against cardiac MRI data from 27 patients scanned within 6 months after acute myocardial infarction. We compared the use of local Pearson's correlation (LPC) and normalized mutual information (NMI) as similarity measures for the registration. The use of 2 and 6 long-axis (LA) cine-MRI scans was also compared. The accuracy of the framework was evaluated using manual segmentation, and the interobserver variability of the scar volume derived from the segmented LV was determined using Bland-Altman analysis.

    RESULTS: LPC outperformed NMI as a similarity measure for the proposed framework using 6 LA scans, with Hausdorrf distance (HD) of 1.19 ± 0.53 mm versus 1.51 ± 2.01 mm (endocardial) and 1.21 ± 0.48 mm versus 1.46 ± 1.78 mm (epicardial), respectively. Segmentation using 2 LA scans was comparable to 6 LA scans with a HD of 1.23 ± 0.70 mm (endocardial) and 1.25 ± 0.74 mm (epicardial). The framework yielded a lower interobserver variability in scar volumes compared with manual segmentation.

    CONCLUSION: The framework showed high accuracy and robustness in delineating LV in LGE-MRI and allowed for bidirectional mapping of information between LGE- and cine-MRI scans, crucial in personalized model studies for treatment planning.

    Matched MeSH terms: Radiotherapy Planning, Computer-Assisted
  15. Jong WL, Ung NM, Wong JH, Ng KH, Wan Ishak WZ, Abdul Malik R, et al.
    Phys Med, 2016 Nov;32(11):1466-1474.
    PMID: 27842982 DOI: 10.1016/j.ejmp.2016.10.022
    The purpose of this study is to measure patient skin dose in tangential breast radiotherapy. Treatment planning dose calculation algorithm such as Pencil Beam Convolution (PBC) and in vivo dosimetry techniques such as radiochromic film can be used to accurately monitor radiation doses at tissue depths, but they are inaccurate for skin dose measurement. A MOSFET-based (MOSkin) detector was used to measure skin dose in this study. Tangential breast radiotherapies ("bolus" and "no bolus") were simulated on an anthropomorphic phantom and the skin doses were measured. Skin doses were also measured in 13 patients undergoing each of the techniques. In the patient study, the EBT2 measurements and PBC calculation tended to over-estimate the skin dose compared with the MOSkin detector (p<0.05) in the "no bolus radiotherapy". No significant differences were observed in the "bolus radiotherapy" (p>0.05). The results from patients were similar to that of the phantom study. This shows that the EBT2 measurement and PBC calculation, while able to predict accurate doses at tissue depths, are inaccurate in predicting doses at build-up regions. The clinical application of the MOSkin detectors showed that the average total skin doses received by patients were 1662±129cGy (medial) and 1893±199cGy (lateral) during "no bolus radiotherapy". The average total skin doses were 4030±72cGy (medial) and 4004±91cGy (lateral) for "bolus radiotherapy". In some cases, patient skin doses were shown to exceed the dose toxicity level for skin erythema. Hence, a suitable device for in vivo dosimetry is necessary to accurately determine skin dose.
    Matched MeSH terms: Radiotherapy Planning, Computer-Assisted
  16. Jamalludin Z, Jong WL, Malik RA, Rosenfeld AB, Ung NM
    Phys Med, 2020 Jan;69:52-60.
    PMID: 31830631 DOI: 10.1016/j.ejmp.2019.11.025
    PURPOSE: Dose to the rectum during brachytherapy treatment may differ from an approved treatment plan which can be quantified with in vivo dosimetry (IVD). This study compares the planned with in vivo doses measured with MOSkin and PTW 9112 rectal probe in patients undergoing CT based HDR cervical brachytherapy with Co-60 source.

    METHODS: Dose measurement of a standard pear-shaped plan carried out in phantom to verify the MOSkin dose measurement accuracy. With MOSkin attached to the third diode, RP3 of the PTW 9112, both detectors were inserted into patients' rectum. The RP3 and MOSkin measured doses in 18 sessions as well as the maximum measured doses from PTW 9112, RPmax in 48 sessions were compared to the planned doses.

    RESULTS: Percentage dose differences ΔD (%) in phantom study for two MOSkin found to be 2.22 ± 0.07% and 2.5 ± 0.07%. IVD of 18 sessions resulted in ΔD(%) of -16.3% to 14.9% with MOSkin and ΔD(%) of -35.7% to -2.1% with RP3. In 48 sessions, RPmax recorded ΔD(%) of -37.1% to 11.0%. MOSkin_measured doses were higher in 44.4% (8/18) sessions, while RP3_measured were lower than planned doses in all sessions. RPmax_measured were lower in 87.5% of applications (42/47).

    CONCLUSIONS: The delivered doses proven to deviate from planned doses due to unavoidable shift between imaging and treatment as measured with MOSkin and PTW 9112 detectors. The integration of MOSkin on commercial PTW 9112 surface found to be feasible for rectal dose IVD during cervical HDR ICBT.

    Matched MeSH terms: Radiotherapy Planning, Computer-Assisted/methods
  17. Jafari SM, Jordan TJ, Distefano G, Bradley DA, Spyrou NM, Nisbet A, et al.
    Br J Radiol, 2015;88(1055):20140804.
    PMID: 26258442 DOI: 10.1259/bjr.20140804
    To investigate the feasibility of using glass beads as novel thermoluminescent dosemeters (TLDs) for radiotherapy treatment plan verification.
    Matched MeSH terms: Radiotherapy Planning, Computer-Assisted/methods*
  18. Hizam NDA, Ung NM, Jong WL, Zin HM, Rahman ATA, Loh JPY, et al.
    Phys Med, 2019 Nov;67:34-39.
    PMID: 31655398 DOI: 10.1016/j.ejmp.2019.10.023
    PURPOSE: Intensity Modulated Radiotherapy (IMRT) has changed the practice of radiotherapy since its implementation in the 1990s. The purpose of this study is to review current practice of IMRT in Malaysia.

    METHODS: A survey on medical physics aspects of IMRT is conducted on radiotherapy departments across Malaysia to assess the usage, experience and QA in IMRT, which is done for the first time in this country. A set of questionnaires was designed and sent to the physicist in charge for their responses. The questionnaire consisted of four sections; (i) Experience and qualification of medical physicists, (ii) CT simulation techniques (iii) Treatment planning and treatment unit, (iv) IMRT process, delivery and QA procedure.

    RESULTS: A total of 26 responses were collected, representing 26 departments out of 33 radiotherapy departments in operation across Malaysia (79% response rate). Results showed that the medical physics aspects of IMRT practice in Malaysia are homogenous, with some variations in certain areas of practices. Thirteen centres (52%) performed measurement-based QA using 2D array detector and analysed using gamma index criteria of 3%, 3 mm with variation confidence range. In relation to the IMRT delivery, 44% of Malaysia's physicist takes more than 8 h to plan a head and neck case compared to the UK study possibly due to the lack of professional training.

    CONCLUSIONS: This survey provides a picture of medical physics aspects of IMRT in Malaysia where the results/data can be used by radiotherapy departments to benchmark their local policies and practice.

    Matched MeSH terms: Radiotherapy Planning, Computer-Assisted
  19. Hizam DA, Jong WL, Zin HM, Ng KH, Ung NM
    Med Dosim, 2021 04 08;46(3):310-317.
    PMID: 33838998 DOI: 10.1016/j.meddos.2021.03.003
    Intensity-modulated radiotherapy (IMRT) treatment planning for head and neck cancer is challenging and complex due to many organs at risk (OAR) in this region. The experience and skills of planners may result in substantial variability of treatment plan quality. This study assessed the performance of IMRT planning in Malaysia and observed plan quality variation among participating centers. The computed tomography dataset containing contoured target volumes and OAR was provided to participating centers. This is to control variations in contouring the target volumes and OARs by oncologists. The planner at each center was instructed to complete the treatment plan based on clinical practice with a given prescription, and the plan was analyzed against the planning goals provided. The quality of completed treatment plans was analyzed using the plan quality index (PQI), in which a score of 0 indicated that all dose objectives and constraints were achieved. A total of 23 plans were received from all participating centers comprising 14 VMAT, 7 IMRT, and 2 tomotherapy plans. The PQI indexes of these plans ranged from 0 to 0.65, indicating a wide variation of plan quality nationwide. Results also reported 5 out of 21 plans achieved all dose objectives and constraints showing more professional training is needed for planners in Malaysia. Understanding of treatment planning system and computational physics could also help in improving the quality of treatment plans for IMRT delivery.
    Matched MeSH terms: Radiotherapy Planning, Computer-Assisted
  20. Hashikin NAA, Yeong CH, Guatelli S, Abdullah BJJ, Ng KH, Malaroda A, et al.
    Phys Med Biol, 2017 Aug 22;62(18):7342-7356.
    PMID: 28686171 DOI: 10.1088/1361-6560/aa7e5b
    We aimed to investigate the validity of the partition model (PM) in estimating the absorbed doses to liver tumour ([Formula: see text]), normal liver tissue ([Formula: see text]) and lungs ([Formula: see text]), when cross-fire irradiations between these compartments are being considered. MIRD-5 phantom incorporated with various treatment parameters, i.e. tumour involvement (TI), tumour-to-normal liver uptake ratio (T/N) and lung shunting (LS), were simulated using the Geant4 Monte Carlo (MC) toolkit. 108track histories were generated for each combination of the three parameters to obtain the absorbed dose per activity uptake in each compartment ([Formula: see text], [Formula: see text], and [Formula: see text]). The administered activities, A were estimated using PM, so as to achieve either limiting doses to normal liver, [Formula: see text] or lungs, [Formula: see text] (70 or 30 Gy, respectively). Using these administered activities, the activity uptake in each compartment ([Formula: see text], [Formula: see text], and [Formula: see text]) was estimated and multiplied with the absorbed dose per activity uptake attained using the MC simulations, to obtain the actual dose received by each compartment. PM overestimated [Formula: see text] by 11.7% in all cases, due to the escaped particles from the lungs. [Formula: see text] and [Formula: see text] by MC were largely affected by T/N, which were not considered by PM due to cross-fire exclusion at the tumour-normal liver boundary. These have resulted in the overestimation of [Formula: see text] by up to 8% and underestimation of [Formula: see text] by as high as  -78%, by PM. When [Formula: see text] was estimated via PM, the MC simulations showed significantly higher [Formula: see text] for cases with higher T/N, and LS  ⩽  10%. All [Formula: see text] and [Formula: see text] by MC were overestimated by PM, thus [Formula: see text] were never exceeded. PM leads to inaccurate dose estimations due to the exclusion of cross-fire irradiation, i.e. between the tumour and normal liver tissue. Caution should be taken for cases with higher TI and T/N, and lower LS, as they contribute to major underestimation of [Formula: see text]. For [Formula: see text], a different correction factor for dose calculation may be used for improved accuracy.
    Matched MeSH terms: Radiotherapy Planning, Computer-Assisted/methods*