Displaying all 9 publications

Abstract:
Sort:
  1. Lai MY, Ooi CH, Lau YL
    Am J Trop Med Hyg, 2018 03;98(3):700-703.
    PMID: 29260656 DOI: 10.4269/ajtmh.17-0738
    The aim of this study was to develop a recombinase polymerase amplification (RPA) combined with a lateral flow (LF) strip method for specific diagnosis of Plasmodium knowlesi. With incubation at 37°C, the 18S rRNA gene of P. knowlesi was successfully amplified within 12 minutes. By adding a specifically designed probe to the reaction solution, the amplified RPA product can be visualized on a LF strip. The RPA assay exhibited high sensitivity with limits of detection down to 10 parasites/μL of P. knowlesi. Nonetheless, it was demonstrated that all P. knowlesi (N = 41) and other Plasmodium sp. (N = 25) were positive while negative samples (N = 8) were negative. Therefore, a combination of RPA and LF strip detection is a highly promising approach with the potential to be suitable for use in resource-limited settings.
    Matched MeSH terms: Recombinases/genetics*
  2. Lau YL, Ismail IB, Mustapa NIB, Lai MY, Tuan Soh TS, Haji Hassan A, et al.
    PLoS One, 2021;16(1):e0245164.
    PMID: 33406112 DOI: 10.1371/journal.pone.0245164
    Rapid diagnosis is an important intervention in managing the Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) outbreak. Real time reverse transcription polymerase chain reaction (RT-qPCR) remains the primary means for diagnosing the new virus strain but it is time consuming and costly. Recombinase polymerase amplification (RPA) is an isothermal amplification assay that does not require a PCR machine. It is an affordable, rapid, and simple assay. In this study, we developed and optimized a sensitive reverse transcription (RT)-RPA assay for the rapid detection of SARS-CoV-2 using SYBR Green I and/or lateral flow (LF) strip. The analytical sensitivity and specificity of the RT-RPA assay were tested by using 10-fold serial diluted synthetic RNA and genomic RNA of similar viruses, respectively. Clinical sensitivity and specificity of the RT-RPA assay were carried out using 78 positive and 35 negative nasopharyngeal samples. The detection limit of both RPA and RT-qPCR assays was 7.659 and 5 copies/μL RNA, respectively with no cross reactivity with other viruses. The clinical sensitivity and specificity of RT-RPA were 98% and 100%, respectively. Our study showed that RT-RPA represents a viable alternative to RT-qPCR for the detection of SARS-CoV-2, especially in areas with limited infrastructure.
    Matched MeSH terms: Recombinases/genetics; Recombinases/metabolism
  3. Nuryastuti T, Henny C, Henk JB, Roel K, Abu TA, Bastiaan PK
    Med J Malaysia, 2008 Jul;63 Suppl A:97.
    PMID: 19025002
    Phenotypic variation in biofilm formation is common in clinical isolates of S. epidermidis. In the current study, nearly 5% of all clinical isolates analysed showed phenotypic variation in biofilm forming ability and electrophoretic mobility (EM). This is the first report of S. epidermidis strains irreversibly switching from biofilm-positive to biofilm-negative phenotype by spontaneous deletion of icaADBC genes which represents a new, possibly common mechanism of phenotypic variation.
    Matched MeSH terms: Rec A Recombinases/genetics*; Rec A Recombinases/metabolism*; Rec A Recombinases/chemistry
  4. Tan KK, Azizan NS, Yaacob CN, Che Mat Seri NAA, Samsudin NI, Teoh BT, et al.
    BMC Infect Dis, 2018 04 11;18(1):169.
    PMID: 29642856 DOI: 10.1186/s12879-018-3065-1
    BACKGROUND: A method for rapid detection of dengue virus using the reverse-transcription recombinase polymerase amplification (RT-RPA) was recently developed, evaluated and made ready for deployment. However, reliance solely on the evaluation performed by experienced researchers in a well-structured and well-equipped reference laboratory may overlook the potential intrinsic problems that may arise during deployment of the assay into new application sites, especially for users unfamiliar with the test. Appropriate assessment of this newly developed assay by users who are unfamiliar with the assay is, therefore, vital.

    METHODS: An operational utility test to elucidate the efficiency and effectiveness of the dengue RT-RPA assay was conducted among a group of researchers new to the assay. Nineteen volunteer researchers with different research experience were recruited. The participants performed the RT-RPA assay and interpreted the test results according to the protocol provided. Deviation from the protocol was identified and tabulated by trained facilitators. Post-test questionnaires were conducted to determine the user satisfaction and acceptability of the dengue RT-RPA assay.

    RESULTS: All the participants completed the test and successfully interpreted the results according to the provided instructions, regardless of their research experience. Of the 19 participants, three (15.8%) performed the assay with no deviations and 16 (84.2%) performed the assay with only 1 to 5 deviations. The number of deviations from protocol, however, was not correlated with the user laboratory experience. The accuracy of the results was also not affected by user laboratory experience. The concordance of the assay results against that of the expected was at 89.3%. The user satisfaction towards the RT-RPA protocol and interpretation of results was 90% and 100%, respectively.

    CONCLUSIONS: The dengue RT-RPA assay can be successfully performed by simply following the provided written instructions. Deviations from the written protocols did not adversely affect the outcome of the assay. These suggest that the RT-RPA assay is indeed a simple, robust and efficient laboratory method for detection of dengue virus. Furthermore, high new user acceptance of the RT-RPA assay suggests that this assay could be successfully deployed into new laboratories where RT-RPA was not previously performed.

    Matched MeSH terms: Recombinases
  5. Lai MY, Lau YL
    Am J Trop Med Hyg, 2022 Oct 12;107(4):815-819.
    PMID: 35970289 DOI: 10.4269/ajtmh.22-0136
    We developed a combination of recombinase polymerase and loop-mediated isothermal amplification methods (RAMP) for rapid screening of five human Plasmodium spp. simultaneously. RAMP is a two-stage isothermal amplification method, which consists of a first-stage recombinase polymerase amplification and a second-stage loop-mediated isothermal amplification. Under these two isothermal conditions, five Plasmodium spp. were amplified in less than 40 minutes. We demonstrated RAMP assay with 10-fold better limit of detection than a single (loop-mediated isothermal amplification) LAMP. As compared with microscopy, RAMP assay showed 100% sensitivity (95% CI: 95.65-100.00%) and 100% specificity (95% CI: 69.15-100.00%). The end products were inspected by the color changes of neutral red. Positive reactions were indicated by pink while the negative reactions remained yellow. The combination assay established in this study can be used as a routine diagnostic method for malaria.
    Matched MeSH terms: Recombinases
  6. Lai MY, Abdul Hamid MH, Jelip J, Mudin RN, Lau YL
    Am J Trop Med Hyg, 2024 Apr 03;110(4):648-652.
    PMID: 38412548 DOI: 10.4269/ajtmh.23-0572
    Loop-mediated isothermal amplification (LAMP) is a nucleic acid amplification technique that can amplify specific nucleic acids at a constant temperature (63-65°C) within a short period (<1 hour). In this study, we report the utilization of recombinase-aided LAMP to specifically amplify the 18S sRNA of Plasmodium knowlesi. The method was built on a conventional LAMP assay by inclusion of an extra enzyme, namely recombinase, into the master mixture. With the addition of recombinase into the LAMP assay, the assay speed was executed within a time frame of less than 28 minutes at 65°C. We screened 55 P. knowlesi samples and 47 non-P. knowlesi samples. No cross-reactivity was observed for non-P. knowlesi samples, and the detection limit for recombinase-aided LAMP was one copy for P. knowlesi after LAMP amplification. It has been reported elsewhere that LAMP can be detected through fluorescent readout systems. Although such systems result in considerable limits of detection, the need for sophisticated equipment limits their use. Hence, we used here a colorimetric detection platform for the evaluation of the LAMP assay's performance. This malachite green-based recombinase-aided LAMP assay enabled visualization of results with the naked eye. Negative samples were observed by a change in color from green to colorless, whereas positive samples remained green. Our results demonstrate that the LAMP assay developed here is a convenient, sensitive, and useful diagnostic tool for the rapid detection of knowlesi malaria parasites. This method is suitable for implementation in remote healthcare settings, where centralized laboratory facilities, funds, and clinicians are in short supply.
    Matched MeSH terms: Recombinases
  7. Lai MY, Abdul Hamid M, Jelip J, Mudin RN, Lau YL
    Am J Trop Med Hyg, 2023 May 03;108(5):882-886.
    PMID: 36913921 DOI: 10.4269/ajtmh.22-0657
    This study highlights the development of two lateral flow recombinase polymerase amplification assays for the diagnosis of human malaria. The lateral flow cassettes contained test lines that captured biotin-, 6-carboxyfluorescein, digoxigenin-, cyanine 5-, and dinitrophenyl-labeled amplicons. The overall process can be completed in 30 minutes. Recombinase polymerase amplification coupled with lateral flow had a detection limit of 1 copy/µL for Plasmodium knowlesi, Plasmodium vivax, and Plasmodium falciparum. No cross-reactivity was observed among nonhuman malaria parasites such as Plasmodium coatneyi, Plasmodium cynomolgi, Plasmodium brasilanium, Plasmodium inui, Plasmodium fragile, Toxoplasma gondii, Sarcocystis spp., Brugia spp., and 20 healthy donors. It is rapid, highly sensitive, robust, and easy to use. The result can be read without the need for special equipment and thus has the potential to serve as an effective alternative to polymerase chain reaction methods for the diagnosis of malaria.
    Matched MeSH terms: Recombinases
  8. Louizi C, Khan MAA, Faisal K, Chowdhury R, Ghosh P, Hossain F, et al.
    Diagn Microbiol Infect Dis, 2023 Feb;105(2):115862.
    PMID: 36493571 DOI: 10.1016/j.diagmicrobio.2022.115862
    The spread of vector habitats along with increasing human mobility can introduce atypical Leishmania species and hence can challenge existing diagnostic practices for rapid detection of active infection with species outside the narrow target range. Here we assessed the pan-Leishmania detection ability of isothermal recombinase polymerase amplification (RPA) assays targeting 18S rRNA gene, cathepsin L-like cysteine proteinase B (Cpb) gene, and kinetoplast minicircle DNA (kDNA) regions. While the lowest limit of detection of the 18S rRNA-RPA and Cpb-RPA assays were estimated as 12 and 17 standard DNA molecules, respectively, both assays could amplify genomic DNA of 7 pathogenic Leishmania species. Evaluation of 18S rRNA-RPA and our previously developed kDNA-RPA assays on 70 real-time PCR-positive leishmaniasis samples of varying pathologies resulted in sensitivity rates of 35.71% and 88.57%, respectively, while the combined sensitivity was 98.57%. Combinatorial application of 18S rRNA-RPA and kDNA-RPA assays can be recommended for further diagnostic assessments.
    Matched MeSH terms: Recombinases/genetics
  9. Ho WY, Choo QC, Chew CH
    Microb Drug Resist, 2017 Mar;23(2):215-223.
    PMID: 27203527 DOI: 10.1089/mdr.2015.0250
    We investigated the epidemiology and clonality of 175 nonrepetitive methicillin-resistant Staphylococcus aureus (MRSA) isolates from clinical specimens collected between 2011 and 2012 in Kinta Valley in Malaysia. Molecular tools such as polymerase chain reaction, pulsed-field gel electrophoresis, and staphylococcal protein A (spa) typing were used. Our study revealed the predominance of three closely related ermA(+) SCCmec type III pulsotypes belonging to spa type t037 (Brazilian-Hungarian clone), which were deficient in the locus F, but positive for the ccrC gene in majority (65.7%) of the MRSA infections in this region. The first evidence of SCCmec type II MRSA in the country, belonging to spa type t2460, was also noted. Although the carriage of pvl gene was uncommon (8.6%) and mostly confined to either SCCmec type IV or SCCmec type V isolates, most of these isolates belonged to spa types t345 or t657, which are associated with the Bengal-Bay CA-MRSA clone. Interestingly, spa t304 and t690 SCCmec type IV pvl(+) were also detected among the MRSA isolates. Data from this study show the rise of uncommon clones among MRSA isolates in Malaysia.
    Matched MeSH terms: Recombinases/genetics*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links