Displaying publications 1 - 20 of 235 in total

Abstract:
Sort:
  1. Ahmad Fuad Abdul Rahim, Mohd Jamil Yaacob, Muhamad Saiful Bahri Yusoff
    ASEAN Journal of Psychiatry, 2010;11(1):36-43.
    MyJurnal
    Objective: To determine the sensitivity, specificity and internal consistency of the Malay version GHQ-12 among medical student population. This study determined the appropriate GHQ-12 score to detect distressed medical students. Methods: The Malay version of GHQ-12 was derived based on two sources which were the original version GHQ-12 and the validated Malay version 30-items GHQ. The GHQ-12 and the Malay version Beck Depression Inventory-II (BDI-II) were administered to a total of 141 medical students. Distress diagnoses were made based on the Malay version BDI-II. ROC curve analysis was applied to determine the sensitivity and specificity of the GHQ-12 by testing against the BDI-II. Reliability analysis (Cronbach’s alpha and item total correlation) was applied to test internal consistency of the
    GHQ-12. The analysis was done using SPSS version 12.Results: The GHQ-12 sensitivity and specificity at cut-off point of 3/4 was 81.3% and 75.3% respectively with positive predictive value (PPV) of 62.9% as well as area under ROC curve more than 0.7. The Cronbach’s alpha value of the GHQ-12 was 0.85.Conclusion: This study showed the Malay version GHQ-12 is a valid and reliable screening tool in detecting distressed medical students. The
    GHQ-12 score equal to or more than 4 was considered as significant distress.
    Matched MeSH terms: ROC Curve
  2. Siti Raudzah Ghazali, Elklit, Ask, Rekaya Vincent Balang, Ameenudeen Sultan, M., Yoke, Yong Chen
    ASEAN Journal of Psychiatry, 2014;15(2):146-152.
    MyJurnal
    Objective: The objective of this study is to determine the optimal cut-off score for the Centre for Epidemiologic Studies Depression scale (CESD) according to Malaysian adolescent norms. Methods: This is a cross-sectional study. Nine hundred and thirty-one adolescents aged 13 to 17 years-old completed the CESD and Hopkins Symptom Checklist-depression scale (HSCL-depression). Results: Results from the receiver operating characteristic (ROC) curve, kappa coefficients and odds ratio analysis showed that CESD cut-off score of 27 was suitable to be used according to Malaysian norms, demonstrating a specificity of 93%. Conclusion: The findings suggest a cut-off score 27 should be used for screening of depression for Malaysian adolescents using the CESD. ASEAN Journal of Psychiatry, Vol. 15 (2): July - December 2014: 146-152.
    Matched MeSH terms: ROC Curve
  3. Ngah, U.K., Aziz, S.A., Aziz, M.E., Murad, M., Mahdi, N.M.N., Shakaff, A.Y.M., et al.
    ASM Science Journal, 2008;2(1):1-11.
    MyJurnal
    The incidences of breast cancer have been rising at an alarming rate. Mass breast screening programmes involving mammography and ultrasound in certain parts of the world have also proven their benefits in early detection. However, radiologists may be confronted with increased workload. An attempt has been made in this paper to rectify part of the problems faced in this area. Expert systems based on the interpretation of mammographic and ultrasound images for classifying patient cases could be utilized by doctors (expert and non-expert) in screening. These softwares consist of MAMMEX (for mammogram) and SOUNDEX (for breast ultrasound) could be used to deduce cases according to Breast Imaging Recording and Data System (BI-RADS), based on patients’ history, physical and clinical assessment, mammograms and breast ultrasound images. A total of 179 retrospective cases from the Radiology Department, hospital of the University of Science Malaysia, Kubang Kerian, Kelantan were used in this study. A receiver operating characteristic (ROC) curve analysis was implemented, based on the usage of a two-class forced choice of classifying suspicious and malignant findings as positive with normal, benign and probably benign classified as negative. Results yielded an area under the curve (AUC) of 0.997 with the least standard error value of 0.003 for MAMMEX while an AUC of 0.996 with the least standard error of 0.004 was accomplished for SOUNDEX. A system which very closely simulated radiologists was also successfully developed in this study. The ROC curve analysis indicated that the expert systems developed were of high performance and reliability.
    Matched MeSH terms: ROC Curve
  4. Trutnovsky G, Kamisan Atan I, Ulrich D, Martin A, Dietz HP
    Acta Obstet Gynecol Scand, 2016 Dec;95(12):1411-1417.
    PMID: 27622984 DOI: 10.1111/aogs.13018
    INTRODUCTION: The study aimed to analyze the relation between the degree of puborectalis muscle trauma and subjective symptoms and objective findings of pelvic organ prolapse (POP), comparing two continuous scoring systems with a discrete scoring system for translabial ultrasound imaging.

    MATERIAL AND METHODS: In this retrospective observational study the records of patients attending a tertiary urogynecological unit between January 2012 and December 2014 were analyzed. POP assessment included a standardized interview, clinical examination using Pelvic Organ Prolapse Quantification and four-dimensional translabial ultrasound. Puborectalis muscle trauma was assessed with tomographic ultrasound imaging using two continuous scoring systems and a previously established discrete system. Receiver operating characteristics and adjusted odds ratios were used for comparison of scoring systems in predicting symptoms and signs of POP.

    RESULTS: Of 1258 women analyzed, 52.6% complained of prolapse symptoms. On ultrasound imaging, 65.7% of women had sonographically significant POP. Complete avulsion was diagnosed in 25.3% of women, being unilateral in 13.9% and bilateral in 11.4%. A maximum score in the 6-point and the 12-point tomographic ultrasound imaging scale increased the odds for a diagnosis of any significant POP on ultrasound by 4.4 and 4.8 times, respectively, compared with 4.6 times for the discrete diagnosis of bilateral avulsion. For all avulsion scoring systems the relation was strongest for cystocele and uterine prolapse.

    CONCLUSIONS: A continuous avulsion scoring system based on tomographic findings does not provide superior performance for the prediction of subjective symptoms and objective findings of prolapse compared with a discrete diagnostic system of unilateral or bilateral avulsion.

    Matched MeSH terms: ROC Curve
  5. Lim L, Ng TP, Ong AP, Tan MP, Cenina AR, Gao Q, et al.
    Alzheimers Res Ther, 2018 01 22;10(1):6.
    PMID: 29370825 DOI: 10.1186/s13195-017-0333-z
    BACKGROUND: Cognitive screeners are imperative for early diagnosis of dementia. The Visual Cognitive Assessment Test (VCAT) is a language-neutral, visual-based test which has proven useful for a multilingual population in a single-center study. However, its performance utility is unknown in a wider and more diverse Southeast Asian cohort.

    METHODS: We recruited 164 healthy controls (HC) and 120 cognitively impaired (CI) subjects- 47 mild cognitive impairment (MCI) and 73 mild Alzheimer's disease (AD) dementia participants, from four countries between January 2015 and August 2016 to determine the usefulness of a single version of the VCAT, without translation or adaptation, in a multinational, multilingual population. The VCAT was administered along with established cognitive evaluation.

    RESULTS: The VCAT, without local translation or adaptation, was effective in discriminating between HC and CI subjects (MCI and mild AD dementia). Mean (SD) VCAT scores for HC and CI subjects were 22.48 (3.50) and 14.17 (5.05) respectively. Areas under the curve for Montreal Cognitive Assessment (0.916, 95% CI 0.884-0.948) and the VCAT (0.905, 95% CI 0.870-0.940) in discriminating between HCs and CIs were comparable. The multiple languages used to administer VCAT in four countries did not significantly influence test scores.

    CONCLUSIONS: The VCAT without the need for language translation or cultural adaptation showed satisfactory discriminative ability and was effective in a multinational, multilingual Southeast Asian population.

    Matched MeSH terms: ROC Curve
  6. Hamizan AW, Rimmer J, Alvarado R, Sewell WA, Tatersall J, Barham HP, et al.
    Am J Rhinol Allergy, 2019 Mar;33(2):178-183.
    PMID: 30656948 DOI: 10.1177/1945892418825224
    BACKGROUND: Specific immunoglobulin E (sIgE) within the nasal airway is likely to be the most ideal marker of allergic status, but little is known of the normative values in asymptomatic patients and those with rhinitis.

    OBJECTIVE: The aim of this study was to assess the diagnostic characteristics of inferior turbinate tissue biopsy sIgE in asymptomatic and rhinitic patients.

    METHODS: A diagnostic cross-sectional study was undertaken, involving patients who underwent inferior turbinate surgery with or without other surgical interventions. Inferior turbinate tissue biopsy was performed during surgery and was assessed for allergen sIgE (dust mite, grass [temperate or subtropical], and animal epithelium) using an automated immunoassay. Tissue sIgE was assessed among asymptomatic patients and those with nasal symptoms. Data were presented as median (interquartile range). A receiver operating curve was used to predict the diagnostic utility of turbinate tissue sIgE in determining allergic rhinitis.

    RESULTS: A total of 160 patients (41.89 ± 14.65 years, 36.9% females) were included. The median tissue sIgE concentration among the asymptomatic nonatopic group of patients was 0.09 (0.08-0.10) kUA/L and tissue sIgE > 0.10 kUA/L was determined as a positive threshold. Inferior turbinate tissue sIgE was shown to be a predictive test for allergic rhinitis (area under curve: 0.87, 95% confidence interval: 0.84-0.90) with 90% sensitivity and 89% negative predictive value.

    CONCLUSION: Inferior turbinate tissue biopsy sIgE is a sensitive tool to predict allergic rhinitis. The threshold value of 0.1 kUA/L corresponded well with the asymptomatic nonatopic group of patients. This method detects sIgE in the nasal mucosa and may be a useful test for allergic rhinitis in future research.

    Matched MeSH terms: ROC Curve
  7. Moutaouakkil Y, Adouani B, Cherrah Y, Lamsaouri J, Bousliman Y
    Ann Indian Acad Neurol, 2019 10 25;22(4):377-383.
    PMID: 31736555 DOI: 10.4103/aian.AIAN_492_18
    Background: Despite many studies suggesting an association between human leukocyte antigen (HLA)-B*15:02 and carbamazepine (CBZ)-induced severe cutaneous adverse drug reactions essentially toxic epidermal necrolysis (TEN) and Stevens-Johnson syndrome (SJS), the evidence of association in different populations and the degree of association remain uncertain.

    Materials and Methods: The primary analysis was based on population control studies. Data were pooled by means of a random-effects model, and sensitivity, specificity, positive and negative likelihood ratios (LR+ and LR-), diagnostic odds ratios (DOR), and areas under the summary receiver operating characteristic curve (AUC) were calculated.

    Results: In 23 population control studies, HLA-B*15:02 was measured in 373 patients with CBZ-induced TEN/SJS and 3452 patients without CBZ-induced TEN/SJS. The pooled sensitivity, specificity, LR+, LR-, DOR, and AUC were 0.67 (95% confidence interval [CI] = 0.63-0.72), 0.98 (95% CI = 0.98-0.99), 19.73 (95% CI = 10.54-36.92), 0.34 (95% CI = 0.23-0.49), 71.38 (95% CI = 34.89-146.05), and 0.96 (95% CI = 0.92-0.98), respectively. Subgroup analyses for Han Chinese, Thai, and Malaysian populations yielded similar findings. Specifically, racial/ethnic subgroup analyses revealed similar findings with respect to DOR for Han Chinese (99.28; 95% CI = 22.20-443.88), Thai (61.01; 95% CI = 23.05-161.44), and Malaysian (30; 95% CI = 7.08-126.68) populations, which are similar to the pooled DOR for the relationship between the HLA-B*15:02 allele and CBZ-induced TEN/SJS across all populations (71.38; 95% CI = 34.89-146.05).

    Conclusions: The present study reveals that CBZ is the leading cause of TEN/SJS in many countries. Screening of HLA-B*15:02 may help patients to prevent the occurrence of CBZ-induced TEN/SJS, especially in populations with a higher (≥5%) risk allele frequency.

    Matched MeSH terms: ROC Curve
  8. Wong RS, Ismail NA, Tan CC
    Ann Acad Med Singap, 2015 Apr;44(4):127-32.
    PMID: 26041636
    INTRODUCTION: Intensive care unit (ICU) prognostic models are predominantly used in more developed nations such as the United States, Europe and Australia. These are not that popular in Southeast Asian countries due to costs and technology considerations. The purpose of this study is to evaluate the suitability of the acute physiology and chronic health evaluation (APACHE) IV model in a single centre Malaysian ICU.

    MATERIALS AND METHODS: A prospective study was conducted at the single centre ICU in Hospital Sultanah Aminah (HSA) Malaysia. External validation of APACHE IV involved a cohort of 916 patients who were admitted in 2009. Model performance was assessed through its calibration and discrimination abilities. A first-level customisation using logistic regression approach was also applied to improve model calibration.

    RESULTS: APACHE IV exhibited good discrimination, with an area under receiver operating characteristic (ROC) curve of 0.78. However, the model's overall fit was observed to be poor, as indicated by the Hosmer-Lemeshow goodness-of-fit test (Ĉ = 113, P <0.001). Predicted in-ICU mortality rate (28.1%) was significantly higher than the actual in-ICU mortality rate (18.8%). Model calibration was improved after applying first-level customisation (Ĉ = 6.39, P = 0.78) although discrimination was not affected.

    CONCLUSION: APACHE IV is not suitable for application in HSA ICU, without further customisation. The model's lack of fit in the Malaysian study is attributed to differences in the baseline characteristics between HSA ICU and APACHE IV datasets. Other possible factors could be due to differences in clinical practice, quality and services of health care systems between Malaysia and the United States.

    Matched MeSH terms: ROC Curve
  9. Low SK, Khoo JK, Tavintharan S, Lim SC, Sum CF
    Ann Acad Med Singap, 2016 Jan;45(1):1-5.
    PMID: 27118222
    Matched MeSH terms: ROC Curve
  10. Zabidi A, Khuan LY, Mansor W
    PMID: 23366136 DOI: 10.1109/EMBC.2012.6346175
    Infant asphyxia is a condition due to insufficient oxygen intake suffered by newborn babies. A 4 to 9 million occurrences of infant asphyxia are reported each year by WHO. Early diagnosis of asphyxia is important to avoid complications such as damage to the brain, organ and tissue that could lead to fatality. This is possible with the automation of screening of infant asphyxia. Here, a non-invasive Asphyxia Screening Kit is developed. It is a Graphical User Interface that automatically detects asphyxia in infants from early birth to 6 months from their cries and displays the outcome of analysis. It is built with Matlab GUI underlied with signal processing algorithms, capable of achieving a classification accuracy of 96.03%. Successful implementation of ASK will assist to screen infant asphyxia for reference to clinicians for early diagnosis. In addition, ASK also provides an interface to enter patient information and images to be integrated with existing Hospital Information Management System.
    Matched MeSH terms: ROC Curve
  11. Subramaniam S, Chan CY, Soelaiman IN, Mohamed N, Muhammad N, Ahmad F, et al.
    Arch Osteoporos, 2019 11 28;14(1):117.
    PMID: 31781876 DOI: 10.1007/s11657-019-0666-2
    The concordance between osteoporosis self-assessment tool for Asians (OSTA) and dual-energy X-ray absorptiometry (DXA) was fair in the study. Modification of OSTA cutoff values improved its sensitivity to identify subjects at risk for suboptimal bone health (osteopenia/osteoporosis) and osteoporosis.

    PURPOSE: Osteoporosis self-assessment tool for Asians (OSTA) is a convenient screening algorithm used widely to identify patients at risk of osteoporosis. Currently, the number of studies validating OSTA in Malaysian population is limited. This study aimed to validate the performance of OSTA in identifying subjects with osteoporosis determined with DXA.

    METHODS: This cross-sectional study recruited 786 Malaysians in Klang Valley, Malaysia. Their bone health status was assessed by DXA and OSTA. The association and agreement between OSTA and bone mineral density assessment by DXA were determined by Pearson's correlation and Cohen's kappa, respectively. Receiver operating characteristics (ROC) curves were used to determine the sensitivity, specificity, and area under the curve (AUC) for OSTA.

    RESULTS: OSTA and DXA showed a fair association in the study (r = 0.382, κ = 0.159, p 

    Matched MeSH terms: ROC Curve
  12. Lai EL, Huang WN, Chen HH, Chen JP, Chen DY, Hsieh TY, et al.
    Arch Osteoporos, 2020 03 27;15(1):54.
    PMID: 32221755 DOI: 10.1007/s11657-020-00726-3
    PURPOSE: Recently, trabecular bone score (TBS) has emerged as an important supplementary assessment tool in osteoporosis diagnosis and management. The high incidence of fragility fracture within the non-osteoporotic range of bone mineral density (BMD), among systemic lupus erythematosus (SLE) patients, highlights the crucial role of bone microarchitecture in osteoporosis. This study aimed to evaluate whether TBS identified existing vertebral fractures (VF) more accurately than BMD in SLE patients.

    METHODS: This study enrolled 147 SLE patients from the Asia Pacific Lupus Collaboration (APLC) cohort, who had BMD and TBS assessed from January 2018 until December 2018. Twenty-eight patients sustaining VF and risk factors associated with increased fracture occurrence were evaluated. Independent risk factors and diagnostic accuracy of VF were analyzed by logistic regression and ROC curve, respectively.

    RESULT: The prevalence of vertebral fracture among SLE patients was 19%. BMD, T-score, TBS, and TBS T-score were significantly lower in the vertebral fracture group. TBS exhibited higher positive predictive value and negative predictive value than L spine and left femur BMD for vertebral fractures. Moreover, TBS had a higher diagnostic accuracy than densitometric measurements (area under curve, 0.811 vs. 0.737 and 0.605).

    CONCLUSION: Degraded microarchitecture by TBS was associated with prevalent vertebral fractures in SLE patients. Our result suggests that TBS can be a complementary tool for assessing vertebral fracture prevalence in this population.

    Matched MeSH terms: ROC Curve
  13. Mumtaz W, Saad MNBM, Kamel N, Ali SSA, Malik AS
    Artif Intell Med, 2018 01;84:79-89.
    PMID: 29169647 DOI: 10.1016/j.artmed.2017.11.002
    BACKGROUND: The abnormal alcohol consumption could cause toxicity and could alter the human brain's structure and function, termed as alcohol used disorder (AUD). Unfortunately, the conventional screening methods for AUD patients are subjective and manual. Hence, to perform automatic screening of AUD patients, objective methods are needed. The electroencephalographic (EEG) data have been utilized to study the differences of brain signals between alcoholics and healthy controls that could further developed as an automatic screening tool for alcoholics.

    METHOD: In this work, resting-state EEG-derived features were utilized as input data to the proposed feature selection and classification method. The aim was to perform automatic classification of AUD patients and healthy controls. The validation of the proposed method involved real-EEG data acquired from 30 AUD patients and 30 age-matched healthy controls. The resting-state EEG-derived features such as synchronization likelihood (SL) were computed involving 19 scalp locations resulted into 513 features. Furthermore, the features were rank-ordered to select the most discriminant features involving a rank-based feature selection method according to a criterion, i.e., receiver operating characteristics (ROC). Consequently, a reduced set of most discriminant features was identified and utilized further during classification of AUD patients and healthy controls. In this study, three different classification models such as Support Vector Machine (SVM), Naïve Bayesian (NB), and Logistic Regression (LR) were used.

    RESULTS: The study resulted into SVM classification accuracy=98%, sensitivity=99.9%, specificity=95%, and f-measure=0.97; LR classification accuracy=91.7%, sensitivity=86.66%, specificity=96.6%, and f-measure=0.90; NB classification accuracy=93.6%, sensitivity=100%, specificity=87.9%, and f-measure=0.95.

    CONCLUSION: The SL features could be utilized as objective markers to screen the AUD patients and healthy controls.

    Matched MeSH terms: ROC Curve
  14. Mohd Zaher ZM, Zambari R, Chan SP, Muruga V, Ng B, Appannah G, et al.
    Asia Pac J Clin Nutr, 2009;18(2):209-16.
    PMID: 19713180
    Many studies in Asia have demonstrated that Asian populations may require lower cut-off levels for body mass index (BMI) and waist circumference to define obesity and abdominal obesity respectively, compared to western populations. Optimal cut-off levels for body mass index and waist circumference were determined to assess the relationship between the two anthropometric- and cardiovascular indices. Receiver operating characteristics analysis was used to determine the optimal cut-off levels. The study sample included 1833 subjects (mean age of 44+/-14 years) from 93 primary care clinics in Malaysia. Eight hundred and seventy two of the subjects were men and 960 were women. The optimal body mass index cut-off values predicting dyslipidaemia, hypertension, diabetes mellitus, or at least one cardiovascular risk factor varied from 23.5 to 25.5 kg/m2 in men and 24.9 to 27.4 kg/m2 in women. As for waist circumference, the optimal cut-off values varied from 83 to 92 cm in men and from 83 to 88 cm in women. The optimal cut-off values from our study showed that body mass index of 23.5 kg/m2 in men and 24.9 kg/m2 in women and waist circumference of 83 cm in men and women may be more suitable for defining the criteria for overweight or obesity among adults in Malaysia. Waist circumference may be a better indicator for the prediction of obesity-related cardiovascular risk factors in men and women compared to BMI. Further investigation using a bigger sample size in Asia needs to be done to confirm our findings.
    Study site: 93 primary care clinics (klinik kesihatan and general practice clinics) in Malaysia
    Matched MeSH terms: ROC Curve
  15. Harvinder GS, Swee WC, Karupaiah T, Sahathevan S, Chinna K, Ahmad G, et al.
    Asia Pac J Clin Nutr, 2016;25(1):26-33.
    PMID: 26965758 DOI: 10.6133/apjcn.2016.25.1.01
    Malnutrition is highly prevalent in Malaysian dialysis patients and there is a need for a valid screening tool for early identification and management. This cross-sectional study aims to examine the sensitivity of the Dialysis Malnutrition Score (DMS) and Malnutrition Inflammation Score (MIS) tools in predicting protein-energy wasting (PEW) among Malaysian dialysis patients.
    Matched MeSH terms: ROC Curve
  16. Ting SL, Lim LT, Ooi CY, Rahman MM
    Asia Pac J Ophthalmol (Phila), 2019;8(3):229-232.
    PMID: 31165604 DOI: 10.22608/APO.2018433
    PURPOSE: To compare the measurement of intraocular pressure (IOP) of Icare rebound tonometer and Perkins applanation tonometer (PAT) during community eye screening and to assess the agreement between these 2 instruments.

    DESIGN: A cross-sectional, non-interventional study.

    METHODS: The IOP measurements by handheld Icare rebound tonometer (Finland) were first performed by a primary care physician. Then the IOP was measured using Perkins Mk3 applanation tonometer (Haag-Streit, UK) by an ophthalmologist who was masked to previous readings from the Icare rebound tonometer. The mean IOP measured by each tonometer was compared. Pearson correlation coefficient was used to explore the correlation between the IOP measurements of the 2 instruments. The level of agreement between them was assessed using the Bland and Altman method.

    RESULTS: A total of 420 left eyes were examined. The mean age of subjects was 38.6 ± 18.2 years. Approximately 67% of subjects were female. The mean IOP was 16.3 ± 4.0 mm Hg using Icare and 13.4 ± 2.3 mm Hg using PAT. Pearson correlation coefficient showed a moderate positive correlation between the 2 methods (r = +0.524, P < 0.001). Linear regression analysis revealed a slope of 0.28 with R² of 0.255. The mean difference between the 2 methods was 2.90 ± 3.5 mm Hg and the sample t-test revealed a statistically significant mean difference from 0 (P < 0.001). The 95% limits of agreement between the 2 methods were between -9.73 and 3.93 mm Hg.

    CONCLUSIONS: The handheld Icare rebound tonometer is a reasonably acceptable screening tool in community practices. However, Icare overestimated IOP with a mean of 2.90 mm Hg higher than the PAT. Thus, using Goldmann applanation tonometer as a confirmatory measurement tool of IOP is suggested.

    Matched MeSH terms: ROC Curve
  17. Guan NC, Isa SM, Hashim AH, Pillai SK, Harbajan Singh MK
    Asia Pac J Public Health, 2015 Mar;27(2):NP2210-9.
    PMID: 22652253 DOI: 10.1177/1010539512447808
    The use of the Internet has been increasing dramatically over the decade in Malaysia. Excessive usage of the Internet has lead to a phenomenon called Internet addiction. There is a need for a reliable, valid, and simple-to-use scale to measure Internet addiction in the Malaysian population for clinical practice and research purposes. The aim of this study was to validate the Malay version of the Internet Addiction Test, using a sample of 162 medical students. The instrument displayed good internal consistency (Cronbach's α = .91), parallel reliability (intraclass coefficient = .88, P < .001), and concurrent validity with the Compulsive Internet Use Scale (Pearson's correlation = .84, P < .001). Receiver operating characteristic analysis showed that 43 was the optimal cutoff score to discriminate students with and without Internet dependence. Principal component analysis with varimax rotation identified a 5-factor model. The Malay version of the Internet Addiction Test appeared to be a valid instrument for assessing Internet addiction in Malaysian university students.
    Matched MeSH terms: ROC Curve
  18. Moy FM, Atiya AS
    Asia Pac J Public Health, 2003;15(2):99-104.
    PMID: 15038683
    Body Mass Index (BMI) is the most established anthropometric indicator used for assessment of nutritional status. Other anthropometric indicators which are related closely to BMI are waist hip ratio (WHR) and waist circumference. In this paper, receiver operating characteristics (ROC) curves were constructed to assess the value of waist circumference and waist hip ratio as a screening measure for the need of weight management using BMI as the reference test. Sensitivity and specificity were calculated at several cut-offs. The areas under the ROC curve calculated by comparing waist circumference with BMI were high (0.70 - 0.86) while the areas calculated for WHR were low (0.46 - 0.67). Sensitivities of 0.745 and 0.800 were observed at cut-off points of waist circumference at 90cm and 80cm for males and females respectively, while the false positive rates were 0.233 for males and 0.250 for females. These cut-off points could be considered as a fair trade-off. Therefore it is concluded that waist circumference performed better than WHR as a screening test. It is indicative that waist circumference could be used as a tool in raising awareness of weight management in this population.
    Matched MeSH terms: ROC Curve
  19. Zulkarnain S, Yunus N, Kandasamy R, Zun AB, Mat Zin AA
    Asian Pac J Cancer Prev, 2020 Oct 01;21(10):3085-3091.
    PMID: 33112571 DOI: 10.31557/APJCP.2020.21.10.3085
    OBJECTIVE: Glioma is the commonest primary malignant brain tumour. Diagnosis is made based on cytology smear, frozen section and histopathological examination. Intraoperative pathological diagnosis using either cytology smear, frozen section or combination of both, plays a crucial role in patient's future management and prognosis. This study aims to determine the accuracy of cytology smear and frozen section in glioma, and to compare the difference between both techniques.

    METHODS: A cross-sectional study was conducted involving 22 cases of glioma diagnosed intraoperatively from January 2013 until August 2019 in Hospital Universiti Sains Malaysia. The selected tissues were processed for cytology smear and frozen section. The remaining tissues were proceeded for paraffin section. The diagnosis was categorized as either low-grade or high-grade glioma based on cellularity, nuclear pleomorphism, mitotic count, microvascular proliferation and necrosis. The sensitivity and specificity of frozen section and cytology smears were determined based on paraffin section being as the gold standard. The accuracy of both techniques was compared using statistical analysis.

    RESULTS: The overall sensitivity and specificity of cytology smear were 100% and 76.9%, respectively. Meanwhile, the sensitivity and specificity of frozen section were 100% and 84.6%. There was no significant difference in diagnostic accuracy between cytology smear and frozen section in glioma (p>0.05).

    CONCLUSION: Cytology smears provides an alternative method for frozen section due to good cellularity and morphology on smear. Cytology smear is rapid, inexpensive, small amount of tissue requirement and less technical demand. This finding may benefit to the hospital or treatment centres where frozen section facility is unavailable.

    Matched MeSH terms: ROC Curve
  20. Jusoh AR, Mohan SV, Lu Ping T, Tengku Din TADAAB, Haron J, Romli RC, et al.
    Asian Pac J Cancer Prev, 2021 May 01;22(5):1375-1381.
    PMID: 34048164 DOI: 10.31557/APJCP.2021.22.5.1375
    OBJECTIVE: This study aimed to characterize the miRNA expression profiles from plasma samples of our local breast cancer patients in comparison to healthy control by using miRNA PCR Array.

    METHODS: In this study, plasma miRNA profiles from eight early-stage breast cancer patients and nine age-matched (± 2 years) healthy controls were characterized by miRNA array-based approach, followed by differential gene expression analysis, Independent T-test and construction of Receiver Operating Characteristic (ROC) curve to determine the capability of the assays to discriminate between breast cancer and the healthy control.

    RESULTS: Based on the 372-miRNAs microarray profiling, a set of 40 differential miRNAs was extracted regarding to the fold change value at 2 and above. We further sub grouped 40 miRNAs of breast cancer patients that were significantly expressed at 2-fold change and higher. In this set, we discovered that 24 miRNAs were significantly upregulated and 16 miRNAs were significantly downregulated in breast cancer patients, as compared to the miRNA expression of healthy subjects. ROC curve analysis revealed that seven miRNAs (miR-125b-5p, miR-142-3p, miR-145-5p, miR-193a-5p, miR-27b-3p, miR-22-5p and miR-423-5p) had area under curve (AUC) value > 0.7 (AUC p-value < 0.05). Overlapping findings from differential gene expression analysis, ROC analysis, and Independent T-Test resulted in three miRNAs (miR-27b-3p, miR-22-5p, miR-145-5p). Cohen's effect size for these three miRNAs was large with d value are more than 0.95.

    CONCLUSION: miR-27b-3p, miR-22-5p, miR-145-5p could be potential biomarkers to distinguish breast cancer patients from healthy controls. A validation study for these three miRNAs in an external set of samples is ongoing.
    .

    Matched MeSH terms: ROC Curve
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links