MATERIALS & METHODS: This was a cross-sectional study involving 101 subjects recruited from the National Institute of Forensic Medicine (IPFN) Hospital Kuala Lumpur (HKL) over a period of 15 months, from December 2012 until April 2014. PMCT CS of the coronary arteries was calculated using Agatston-Janowitz score. Histological presence of calcification was observed and the degree of stenosis was calculated using an image analysis technique.
RESULTS: PMCT CS increased with increasing severity of stenosis (p<0.001). PMCT CS showed a positive correlation with the presence of calcification (r=-0.82, p<0.001).
CONCLUSION: Calcium score is strongly associated with coronary artery calcification and the degree of luminal stenosis in post mortem subjects. Thus, PMCT may be useful as a non-invasive tool in diagnosing CAD in the event that an autopsy is not possible.
METHODS: A total of 15 femora were examined with four parameters i.e. maximum length of femur (FeMl), diameter of femoral head (FeHd), transverse diameter of midshaft (FeMd) and condylar breadth (FeCb). Osteometric board and vernier calipers were employed for the conventional method, while CT reconstructed images and Osirix MD software was utilised for the virtual method.
RESULTS: Results exhibited that there were no significant differences in the measurements by conventional and virtual methods. There were also no significant differences in the measurements by the intra or inter-observer error analyses. The intraclass correlation coefficients (ICC) were more than 0.95 by both intra and inter-observer error analyses. Technical error of measurement had displayed values within the acceptable ranges (rTEM <0.08 for intra-observer, <2.25 for inter-observer), and coefficient of reliability (R) indicated small measurement errors (R > 0.95 for intra-observer, R > 0.92 for inter-observer). By parameters, FeMl showed the highest R value (0.99) with the least error in different methods and observers (rTEM = 0.02-0.41%). Bland and Altman plots revealed points scattered close to zero indicating perfect agreement by both virtual and conventional methods. The mean differences for FeMl, FeHd, FeMd and FeCb measurements were 0.01 cm, -0.01 cm, 0.02 cm and 0.01 cm, respectively.
CONCLUSION: This brought to suggest that bone measurement by virtual method was highly accurate and reliable as in the conventional method. It is recommended for implementation in the future anthropological studies especially in countries with limited skeletal collection.