AIM: Aging-associated CI can impair the ability of individuals to perform a VF test and compromise the reliability of the results. We evaluated the association between neurocognitive impairment and VF reliability indices in glaucoma patients.
METHODS: This prospective, cross-sectional study was conducted in the Ophthalmology Department, Hospital Kuala Pilah, Malaysia, and included 113 eyes of 60 glaucoma patients with no prior diagnosis of dementia. Patients were monitored with the Humphrey Visual Field Analyzer using a 30-2 SITA, standard protocol, and CI was assessed using the clock drawing test (CDT). The relationships between the CDT score, MD, pattern standard deviation, Visual Field Index (VFI), fixation loss (FL), false-positive values, and FN values were analyzed using the ordinal regression model.
RESULTS: Glaucoma patients older than 65 years had a higher prevalence of CI. There was a statistically significant correlation between CDT scores and glaucoma severity, FL, FN, and VFI values (rs=-0.20, P=0.03; rs=-0.20, P=0.04; rs=-0.28, P=0.003; rs=0.21, P=0.03, respectively). In a multivariate model adjusted for age and glaucoma severity, patients with lower FN were significantly less likely to have CI (odds ratio, 0.91; 95% confidence interval, 0.89-0.93) and patients with higher MD were more likely to have CI (odds ratio, 1.10; 95% confidence interval, 1.05-1.16); false positive, FL, pattern standard deviation, and VFI showed no significant correlation.
CONCLUSION: Cognitive decline is associated with reduced VF reliability, especially with higher FN rate and overestimated MD. Screening and monitoring of CI may be important in the assessment of VF progression in glaucoma patients.
METHODS: This prospective study included a derivation cohort before validation in multiple international cohorts. The derivation cohort was a cross-sectional, multicentre study of patients aged 18 years or older, scheduled to have a liver biopsy for suspicion of NAFLD at seven tertiary care liver centres in England. This was a prespecified secondary outcome of a study for which the primary endpoints have already been reported. Liver stiffness measurement (LSM) by vibration-controlled transient elastography and controlled attenuation parameter (CAP) measured by FibroScan device were combined with aspartate aminotransferase (AST), alanine aminotransferase (ALT), or AST:ALT ratio. To identify those patients with NASH, an elevated NAS, and significant fibrosis, the best fitting multivariable logistic regression model was identified and internally validated using boot-strapping. Score calibration and discrimination performance were determined in both the derivation dataset in England, and seven independent international (France, USA, China, Malaysia, Turkey) histologically confirmed cohorts of patients with NAFLD (external validation cohorts). This study is registered with ClinicalTrials.gov, number NCT01985009.
FINDINGS: Between March 20, 2014, and Jan 17, 2017, 350 patients with suspected NAFLD attending liver clinics in England were prospectively enrolled in the derivation cohort. The most predictive model combined LSM, CAP, and AST, and was designated FAST (FibroScan-AST). Performance was satisfactory in the derivation dataset (C-statistic 0·80, 95% CI 0·76-0·85) and was well calibrated. In external validation cohorts, calibration of the score was satisfactory and discrimination was good across the full range of validation cohorts (C-statistic range 0·74-0·95, 0·85; 95% CI 0·83-0·87 in the pooled external validation patients' cohort; n=1026). Cutoff was 0·35 for sensitivity of 0·90 or greater and 0·67 for specificity of 0·90 or greater in the derivation cohort, leading to a positive predictive value (PPV) of 0·83 (84/101) and a negative predictive value (NPV) of 0·85 (93/110). In the external validation cohorts, PPV ranged from 0·33 to 0·81 and NPV from 0·73 to 1·0.
INTERPRETATION: The FAST score provides an efficient way to non-invasively identify patients at risk of progressive NASH for clinical trials or treatments when they become available, and thereby reduce unnecessary liver biopsy in patients unlikely to have significant disease.
FUNDING: Echosens and UK National Institute for Health Research.
PATIENTS AND METHODS: Data of 2360 patients from APASL-ACLF Research Consortium (AARC) was analysed. Multivariate logistic regression model (PIRO score) was developed from a derivation cohort (n=1363) which was validated in another prospective multicentric cohort of acute on chronic liver failure patients (n=997).
RESULTS: Factors significant for P component were serum creatinine[(≥2 mg/dL)OR 4.52, 95% CI (3.67-5.30)], bilirubin [(<12 mg/dL,OR 1) vs (12-30 mg/dL,OR 1.45, 95% 1.1-2.63) vs (≥30 mg/dL,OR 2.6, 95% CI 1.3-5.2)], serum potassium [(<3 mmol/LOR-1) vs (3-4.9 mmol/L,OR 2.7, 95% CI 1.05-1.97) vs (≥5 mmol/L,OR 4.34, 95% CI 1.67-11.3)] and blood urea (OR 3.73, 95% CI 2.5-5.5); for I component nephrotoxic medications (OR-9.86, 95% CI 3.2-30.8); for R component,Systemic Inflammatory Response Syndrome,(OR-2.14, 95% CI 1.4-3.3); for O component, Circulatory failure (OR-3.5, 95% CI 2.2-5.5). The PIRO score predicted acute kidney injury with C-index of 0.95 and 0.96 in the derivation and validation cohort. The increasing PIRO score was also associated with mortality (P
METHODS: A retrospective analysis was performed on post-bariatric surgery patients who underwent laparoscopy for diagnosis and treatment of chronic abdominal pain at a single academic center. Only patients with both negative preoperative CT scan and upper endoscopy were included.
RESULTS: Total of 35 post-bariatric surgery patients met the inclusion criteria, and all had history of Roux-en-Y gastric bypass. Twenty out of 35 patients (57%) had positive findings on diagnostic laparoscopy including presence of adhesions (n = 12), chronic cholecystitis (n = 4), mesenteric defect (n = 2), internal hernia (n = 1), and necrotic omentum (n = 1). Two patients developed post-operative complications including a pelvic abscess and an abdominal wall abscess. Overall, 15 patients (43%) had symptomatic improvement after laparoscopy; 14 of these patients had positive laparoscopic findings requiring intervention (70% of the patients with positive laparoscopy). Conversely, 20 (57%) patients required long-term medical treatment for management of chronic abdominal pain.
CONCLUSION: Diagnostic laparoscopy, which is a safe procedure, can detect pathological findings in more than half of post-bariatric surgery patients with chronic abdominal pain of unknown etiology. About 40% of patients who undergo diagnostic laparoscopy and 70% of patients with positive findings on laparoscopy experience significant symptom improvement. Patients should be informed that diagnostic laparoscopy is associated with no symptom improvement in about half of cases.
BACKGROUND: The current generation of bioresorbable scaffolds has several limitations, such as thick square struts with large footprints that preclude their deep embedment into the vessel wall, resulting in protrusion into the lumen with microdisturbance of flow. The Mirage sirolimus-eluting bioresorbable microfiber scaffold is designed to address these concerns.
METHODS: In this prospective, single-blind trial, 60 patients were randomly allocated in a 1:1 ratio to treatment with a Mirage sirolimus-eluting bioresorbable microfiber scaffold or an Absorb bioresorbable vascular scaffold. The clinical endpoints were assessed at 30 days and at 6 and 12 months. In-device angiographic late loss at 12 months was quantified. Secondary optical coherence tomographic endpoints were assessed post-scaffold implantation at 6 and 12 months.
RESULTS: Median angiographic post-procedural in-scaffold minimal luminal diameters of the Mirage and Absorb devices were 2.38 mm (interquartile range [IQR]: 2.06 to 2.62 mm) and 2.55 mm (IQR: 2.26 to 2.71 mm), respectively; the effect size (d) was -0.29. At 12 months, median angiographic in-scaffold minimal luminal diameters of the Mirage and Absorb devices were not statistically different (1.90 mm [IQR: 1.57 to 2.31 mm] vs. 2.29 mm [IQR: 1.74 to 2.51 mm], d = -0.36). At 12-month follow-up, median in-scaffold late luminal loss with the Mirage and Absorb devices was 0.37 mm (IQR: 0.08 to 0.72 mm) and 0.23 mm (IQR: 0.15 to 0.37 mm), respectively (d = 0.20). On optical coherence tomography, post-procedural diameter stenosis with the Mirage was 11.2 ± 7.1%, which increased to 27.4 ± 12.4% at 6 months and remained stable (31.8 ± 12.9%) at 1 year, whereas the post-procedural optical coherence tomographic diameter stenosis with the Absorb was 8.4 ± 6.6%, which increased to 16.6 ± 8.9% and remained stable (21.2 ± 9.9%) at 1-year follow-up (Mirage vs. Absorb: dpost-procedure = 0.41, d6 months = 1.00, d12 months = 0.92). Angiographic median in-scaffold diameter stenosis was significantly different between study groups at 12 months (28.6% [IQR: 21.0% to 40.7%] for the Mirage, 18.2% [IQR: 13.1% to 31.6%] for the Absorb, d = 0.39). Device- and patient-oriented composite endpoints were comparable between the 2 study groups.
CONCLUSIONS: At 12 months, angiographic in-scaffold late loss was not statistically different between the Mirage and Absorb devices, although diameter stenosis on angiography and on optical coherence tomography was significantly higher with the Mirage than with the Absorb. The technique of implantation was suboptimal for both devices, and future trials should incorporate optical coherence tomographic guidance to allow optimal implantation and appropriate assessment of the new technology, considering the novel mechanical properties of the Mirage.
METHODS: A total of 509 patients with MetS were recruited. All were diagnosed by clinicians with ultrasonography-confirmed whether they were patients with NAFLD. Patients were randomly divided into derivation (n=400) and validation (n=109) cohort. To develop the risk score, clinical risk indicators measured at the time of recruitment were built by logistic regression. Regression coefficients were transformed into item scores and added up to a total score. A risk scoring scheme was developed from clinical predictors: BMI ≥25, AST/ALT ≥1, ALT ≥40, type 2 diabetes mellitus and central obesity. The scoring scheme was applied in validation cohort to test the performance.
RESULTS: The scheme explained, by area under the receiver operating characteristic curve (AuROC), 76.8% of being NAFLD with good calibration (Hosmer-Lemeshow χ2 =4.35; P=.629). The positive likelihood ratio of NAFLD in patients with low risk (scores below 3) and high risk (scores 5 and over) were 2.32 (95% CI: 1.90-2.82) and 7.77 (95% CI: 2.47-24.47) respectively. When applied in validation cohort, the score showed good performance with AuROC 76.7%, and illustrated 84%, and 100% certainty in low- and high-risk groups respectively.
CONCLUSIONS: A simple and non-invasive scoring scheme of five predictors provides good prediction indices for NAFLD in MetS patients. This scheme may help clinicians in order to take further appropriate action.
CONCLUSION: An 8-week duration of treatment with LDV/SOF is highly effective in properly selected patients; greater use of this regimen is recommended. (Hepatology 2017;65:1094-1103).