Displaying publications 21 - 40 of 675 in total

Abstract:
Sort:
  1. Sharifah NA, Hayati AR, Meah F, al-Rashid Z
    Malays J Pathol, 1993 Jun;15(1):53-8.
    PMID: 8277791
    Our experience with 1,094 consecutive fine needle aspirations (FNAs) of the breast in 918 cases is presented. Correlation between the FNA cytology and subsequent histology of the lesions was available in 211 cases. FNA had a sensitivity rate of 87.3%, a specificity rate of 99.3% and a positive predictive value of 98.2%. A false negative diagnosis rate of 5.1% occurred. The overall diagnostic accuracy rate was 95.7%.
    Matched MeSH terms: Biopsy, Needle*
  2. Chan PWK, Ramanujam TM, Goh AYT, Lum LCS, Debruyne JA, Chan L
    Med J Malaysia, 2003 Dec;58(5):636-40.
    PMID: 15190646
    An open lung biopsy was performed in 12 children with diffuse parenchymal lung disease. A definitive histopathological diagnosis was obtained from all procedures but determined treatment options in only 10 children (83%). Three (25%) children were ventilated for respiratory failure prior to the procedure. Four (44%) of the other 9 children required ventilatory support after the procedure. Three (25%) children developed post-op pneumothorax that resolved fully with chest tube drainage. There were no deaths as a direct result of the procedure. Open lung biopsy is useful in providing a definitive diagnosis in children with diffuse parenchymal lung disease and determining treatment in the majority of cases. The procedure was well-tolerated with minimal complications.
    Matched MeSH terms: Biopsy*
  3. Lim LY, Tan GH, Zainuddin ZM, Fam XI, Goh EH, Syaris OS, et al.
    Urol Ann, 2020 07 17;12(3):276-282.
    PMID: 33100755 DOI: 10.4103/UA.UA_98_19
    Purpose: There is mounting evidence to suggest that multiparametric magnetic resonance imaging (mpMRI)-guided biopsy is better than systematic biopsy for the diagnosis of prostate cancer (PCa). Cognitive fusion biopsy (CFB) involves targeted biopsies of areas of suspicious lesions noted on the mpMRI by transrectal ultrasound (TRUS) operator. This study was undertaken to determine the accuracy of mpMRI of the prostate with Prostate Imaging-Reporting and Data System (PI-RADS) version 2 in detecting PCa. We also compare the cancer detection rates between systematic 12-core TRUS biopsy and CFB.

    Materials and Methods: Sixty-nine men underwent mpMRI of the prostate followed by TRUS biopsy. In addition to 12-core biopsy, CFB was performed on abnormal lesions detected on MRI.

    Results: Abnormal lesions were identified in 98.6% of the patients, and 59.4% had the highest PI-RADS score of 3 or more. With the use of PI-RADS 3 as cutoff, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of MRI for the detection of PCa were 91.7%, 57.8%, 53.7%, and 92.8%, respectively. With the use of PI-RADS 4 as cutoff, the sensitivity, specificity, PPV, and NPV of mpMRI were 66.7%, 91.1%, 80%, and 83.7%, respectively. Systematic biopsy detected more PCa compared to CFB (29% vs. 26.1%), but CFB detected more significant (Gleason grade ≥7) PCa (17.4% vs. 14.5%) (P < 0.01). CFB cores have a higher PCa detection rate as compared to systematic cores (P < 0.01).

    Conclusions: mpMRI has a good predictive ability for PCa. CFB is superior to systematic biopsy in the detection of the significant PCa.

    Matched MeSH terms: Image-Guided Biopsy; Biopsy, Large-Core Needle
  4. Lee SA, Chiu CK, Chan CYW, Yaakup NA, Wong JHD, Kadir KAA, et al.
    Spine J, 2020 07;20(7):1114-1124.
    PMID: 32272253 DOI: 10.1016/j.spinee.2020.03.015
    BACKGROUND CONTEXT: Biopsy is important to obtain microbiological and histopathological diagnosis in spine infections and tumors. To date, there have been no prospective randomized trials comparing fluoroscopic guided and computed tomography (CT) transpedicular biopsy techniques. The goal of this study was to evaluate the accuracy, safety, and diagnostic outcome of these two diagnostic techniques.

    PURPOSE: To evaluate the accuracy, safety, and diagnostic outcome of fluoroscopic guided and CT transpedicular biopsy techniques.

    STUDY DESIGN: Prospective randomized trial.

    PATIENT SAMPLE: Sixty consecutive patients with clinical symptoms and radiological features suggestive of spinal infection or malignancy were recruited and randomized into fluoroscopic or CT guided spinal biopsy groups. Both groups were similar in terms of patient demographics, distribution of spinal infections and malignancy cases, and the level of biopsies.

    OUTCOME MEASURES: The primary outcome measure was diagnostic accuracy of both methods, determined based on true positive, true negative, false positive, and false negative biopsy findings. Secondary outcome measures included radiation exposure to patients and doctors, complications, and postbiopsy pain score.

    METHODS: A transpedicular approach was performed with an 8G core biopsy needle. Specimens were sent for histopathological and microbiological examinations. Diagnosis was made based on biopsy results, clinical criteria and monitoring of disease progression during a 6-month follow up duration. Clinical criteria included presence of risk factors, level of inflammatory markers and magnetic resonance imaging findings. Radiation exposure to patients and doctors was measured with dosimeters.

    RESULTS: There was no significant difference between the diagnostic accuracy of fluoroscopic and CT guided spinal biopsy (p=0.67) or between the diagnostic accuracy of spinal infection and spinal tumor in both groups (p=0.402 for fluoroscopy group and p=0.223 for CT group). Radiation exposure to patients was approximately 26 times higher in the CT group. Radiation exposure to doctors in the CT group was approximately 2 times higher compared to the fluoroscopic group if a lead shield was not used. Lead shields significantly reduced radiation exposure to doctors anywhere from 2 to 8 times. No complications were observed for either group and the differences in postbiopsy pain scores were not significant.

    CONCLUSIONS: The accuracy, procedure time, complication rate and pain score for both groups were similar. However, radiation exposure to patients and doctors were significantly higher in the CT group without lead protection. With lead protection, radiation to doctors reduced significantly.

    Matched MeSH terms: Biopsy; Biopsy, Large-Core Needle
  5. Sallehuddin, A., Saw, A., George, J., Sengupta, S.
    Malays Orthop J, 2008;2(1):12-16.
    MyJurnal
    Purpose: To evaluate the usefulness of ultrasound guidance in percutaneous needle biopsy for musculoskeletal tumours.
    Methods: Forty-five consecutive patients underwent ultrasound-guided needle biopsy. An additional group of 50 patients who underwent needle biopsy without ultrasound guidance was retrospectively selected as historical control. The sample was considered adequate when a diagnosis can be made, and diagnostic when the diagnosis is similar to the final report based on the excised tumour.
    Results: Adequacy of the biopsy samples was 84% in ultrasound-guided group as compared 76% in the group with no ultrasound guidance. Diagnostic accuracy was 64% in the ultrasound-guided group and 52% in the group without ultrasound guidance. Both of these differences were not statistically significant.
    Conclusions: Ultrasound guidance did not provide a significant advantage in the biopsy of musculoskeletal tumours. Diagnostic accuracy seems to improve with the use of larger 14 gauge biopsy needle but further evaluation is necessary.
    Matched MeSH terms: Biopsy, Needle; Image-Guided Biopsy
  6. Canivet CM, Zheng MH, Qadri S, Vonghia L, Chuah KH, Costentin C, et al.
    Clin Gastroenterol Hepatol, 2023 Nov;21(12):3097-3106.e10.
    PMID: 37031715 DOI: 10.1016/j.cgh.2023.03.032
    BACKGROUND & AIMS: Drug development in nonalcoholic steatohepatitis (NASH) is hampered by a high screening failure rate that reaches 60% to 80% in therapeutic trials, mainly because of the absence of fibrotic NASH on baseline liver histology. MACK-3, a blood test including 3 biomarkers (aspartate aminotransferase, homeostasis model assessment, and cytokeratin 18), recently was developed for the noninvasive diagnosis of fibrotic NASH. We aimed to validate the diagnostic accuracy of this noninvasive test in an international multicenter study.

    METHODS: A total of 1924 patients with biopsy-proven nonalcoholic fatty liver disease from 10 centers in Asia, Australia, and Europe were included. The blood test MACK-3 was calculated for all patients. FibroScan-aspartate aminotransferase score (FAST), an elastography-based test for fibrotic NASH, also was available in a subset of 655 patients. Fibrotic NASH was defined as the presence of NASH on liver biopsy with a Nonalcoholic Fatty Liver Disease Activity Score of 4 or higher and fibrosis stage of F2 or higher according to the NASH Clinical Research Network scoring system.

    RESULTS: The area under the receiver operating characteristic of MACK-3 for fibrotic NASH was 0.791 (95% CI 0.768-0.814). Sensitivity at the previously published MACK-3 threshold of less than 0.135 was 91% and specificity at a greater than 0.549 threshold was 85%. The MACK-3 area under the receiver operating characteristic was not affected by age, sex, diabetes, or body mass index. MACK-3 and FAST results were well correlated (Spearman correlation coefficient, 0.781; P < .001). Except for an 8% higher rate of patients included in the grey zone, MACK-3 provided similar accuracy to that of FAST. Both tests included 27% of patients in their rule-in zone, with 85% specificity and 35% false positives (screen failure rate).

    CONCLUSIONS: The blood test MACK-3 is an accurate tool to improve patient selection in NASH therapeutic trials.

    Matched MeSH terms: Biopsy/methods
  7. Hashim E, Hong J, Woo YL, Hamdan M, Tan PC
    Obstet Gynecol, 2024 Jul 01;144(1):53-59.
    PMID: 38703361 DOI: 10.1097/AOG.0000000000005597
    OBJECTIVE: To compare insertion failure rates for Pipelle endometrial sampling with a full bladder compared with the standard process (not taking into account bladder status) without cervical manipulation.

    METHODS: A single-masked randomized trial was conducted in a single tertiary care center from July 2021 to January 2022. Two hundred fourteen participants aged 18 years or older who were scheduled for outpatient Pipelle endometrial sampling were randomized: 107 each to having a full bladder (by oral water intake) or standard process (without delayed sampling and bladder status not taken into account). Women with known cervical stenosis, gynecologic malignancy, uterine anomalies, leiomyoma distorting the uterine cavity, acute cervicitis, urge bladder dysfunction, intense anxiety, need for anesthesia or analgesic before the procedure, positive pregnancy test, or previous failed office endometrial sampling were excluded. The primary outcome was the insertion failure rate of endometrial sampling at first attempt. Secondary outcomes were pain during procedure, satisfaction score, analgesia use, procedure duration, and need for cervical manipulation. Factoring in a baseline insertion failure rate of 30.0%, relative risk of 0.45, α of 0.05, 80.0% power, and a dropout rate of 10.0%, we needed 107 participants in each arm.

    RESULTS: The insertion failure rate was significantly lower in the full bladder group compared with standard process: 25 of 107 (23.4%) compared with 45 of 107 (42.1%) (relative risk 0.56, 95% CI, 0.37-0.84; number needed to treat to benefit 6.0, 95% CI, 3.20-15.70). Pain score (median) during the procedure (interquartile range) was 4 (3-6) compared with 5 (3-8) ( P =.004); patient satisfaction score was 8 (7-9) compared with 7 (4-8) ( P

    Matched MeSH terms: Biopsy/methods
  8. Chan K, Ghani DAM, Teoh J, Brodie A, Gan C, Foley C, et al.
    Urol Oncol, 2024 Dec;42(12):421-428.
    PMID: 39299895 DOI: 10.1016/j.urolonc.2024.08.019
    Conventionally, transrectal ultrasound guided prostate biopsy (TRUS-Bx) was the main technique used for the diagnosis of prostate cancer since it was first described in 1989 [1]. However, the PROMIS trial showed that this random, nontargeted approach could miss up to 18% of clinically significant cancer (csPCa) [2]. Furthermore, risk of sepsis post TRUS-Bx can be as high as 2.4% [3]. Understanding the demerits of TR-biopsy have led to the introduction of transperineal prostate biopsy (TP-Bx). The incorporation of mpMRI revolutionized prostate cancer diagnostics, allowing visualization of areas likely to harbor csPCa whilst permitting some men to avoid an immediate biopsy. Furthermore, the advent of prostate specific membrane antigen-positron emission tomography (PSMA-PET) is highly promising, because of its role in primary diagnosis of prostate cancer and its higher diagnostic accuracy over conventional imaging in detecting nodal and metastatic lesions. Our narrative review provides an overview on prostate biopsy techniques and an update on prostate imaging, with particular focus on PSMA-PET.
    Matched MeSH terms: Image-Guided Biopsy/methods
  9. Tham TM, Iyengar KR, Taib NA, Yip CH
    Asian Pac J Cancer Prev, 2009 Jan-Mar;10(1):155-8.
    PMID: 19469645
    BACKGROUND: The ideal method for diagnosis of breast cancer is debatable.
    METHODS: The methods of diagnosis of 436 new cases of breast adenocarcinoma presenting from Jan 2005 till Dec 2006 at the University Malaya Medical Centre (UMMC) were examined in this study.
    RESULTS: A total of 388 cases presented to the breast unit in UMMC primarily and 48 cases were diagnosed in non-breast units in other hospitals and referred for management. Fine needle aspiration cytology (FNAC) was the commonest mode of initial diagnosis in 278 cases followed by core needle biopsy and surgical excision. In UMMC, FNAC was the commonest initial method (68.3%) compared to cases diagnosed outside UMMC, where 37.5% of cases were diagnosed by excision. Tumours less than 2cm were more likely to be diagnosed by excision biopsy.
    CONCLUSION: The biopsy method used to confirm the diagnosis is influenced by where the patient first presents, and by the size of the tumour.
    Matched MeSH terms: Biopsy/methods*; Biopsy, Needle; Biopsy, Fine-Needle
  10. Mariappan P, Chong WL, Sundram M, Mohamed SR
    BJU Int, 2004 Aug;94(3):307-10.
    PMID: 15291857
    To determine if a volume-adjusted increase in the number of biopsy cores could detect more prostate cancers than the standard sextant biopsy alone, without increasing morbidity, and to determine its applicability in Malaysian patients, as a standard sextant biopsy misses 20-25% of prostate malignancies.
    Matched MeSH terms: Biopsy, Needle/adverse effects; Biopsy, Needle/methods; Biopsy, Needle/standards
  11. Xu S, Kang Y, Soeharno H, Yeo N
    Malays Orthop J, 2020 Nov;14(3):194-197.
    PMID: 33403086 DOI: 10.5704/MOJ.2011.033
    Marjolin's ulcer is a rare and often overlooked diagnosis which can be encountered by a variety of specialities. Majority of the literatures describe long latency period of 11 to 75 years. The authors present two unusual cases of rapid progression to Marjolin's ulcer in patients with previously negative biopsy 8- and 10-month prior. This highlights the importance for clinicians to have a high degree of suspicion when encountered with any non-healing wound, especially one who's symptomatology and morphological features have undergone an acute change. Even with previous negative biopsy, patients should still be followed-up closely and clinicians should not hesitate to perform re-biopsy if the suspicion arises.
    Matched MeSH terms: Biopsy
  12. Ge N, Brugge WR, Saxena P, Sahai A, Adler DG, Giovannini M, et al.
    Endosc Ultrasound, 2019 9 26;8(6):418-427.
    PMID: 31552915 DOI: 10.4103/eus.eus_61_19
    Background and Objectives: Currently, pancreatic cystic lesions (PCLs) are recognized with increasing frequency and have become a more common finding in clinical practice. EUS is challenging in the diagnosis of PCLs and evidence-based decisions are lacking in its application. This study aimed to develop strong recommendations for the use of EUS in the diagnosis of PCLs, based on the experience of experts in the field.

    Methods: A survey regarding the practice of EUS in the evaluation of PCLs was drafted by the committee member of the International Society of EUS Task Force (ISEUS-TF). It was disseminated to experts of EUS who were also members of the ISEUS-TF. In some cases, percentage agreement with some statements was calculated; in others, the options with the greatest numbers of responses were summarized.

    Results: Fifteen questions were extracted and disseminated among 60 experts for the survey. Fifty-three experts completed the survey within the specified time frame. The average volume of EUS cases at the experts' institutions is 988.5 cases per year.

    Conclusion: Despite the limitations of EUS alone in the morphologic diagnosis of PCLs, the results of the survey indicate that EUS-guided fine-needle aspiration is widely expected to become a more valuable method.

    Matched MeSH terms: Biopsy, Fine-Needle
  13. Bongso TA, Jainudeen MR, Zahrah AS
    Theriogenology, 1982 Nov;18(5):513-24.
    PMID: 16725772
    Scrotal circumference (SC) and body weight (BW) measurements were obtained from 122 crossbred (SaanenxLoca; JumnaparixLocal) bucks, ranging in age from 3 to 28 months. Spermatogenesis and semeniferous tubule diameters were studied from testicular biopsies in 24 bucks. The results showed that SC increased curvilinearly and was significantly correlated with age (P<0.05). Scrotal circumference correlated more significantly with BW (P<0.001). Spermatogenesis was completed at 6-7 months with a sudden increase in tubular diameter at the same time. Since SC is an indirect measurement of testicular size, a marked increase in testicular size indicated the onset of active spermatogenesis and, hence, the possibility of using bucks for breeding at an earlier age than normally recommended. Further, SC norms obtained in this study may become useful in the evaluation of bucks for breeding soundness.
    Matched MeSH terms: Biopsy
  14. Ng, W.M., Ong, T.C., Kwan, M.K., Cheok, C.Y.
    Malays Orthop J, 2008;2(1):49-51.
    MyJurnal
    We report here a rare presentation of an extra-nodal non-Hodgkin's lymphoma. Both clinical presentation radiological findings were suggestive of psoas abscess. Surgical debridement was performed and histopathological examination of the tissue sample revealed the diagnosis of non-Hodgkin's lymphoma. It is therefore important to note that non-Hodgkin's lymphoma can mimic psoas abscess and that psoas lesion with vertebral involvement does not necessarily indicate infection. It is always advisable to obtain needle biopsy to establish diagnosis before embarking on surgical intervention. The practice to send any suspicious tissue obtained intra-operatively for histopathological examination is also warranted.
    Matched MeSH terms: Biopsy, Needle
  15. Sathasivam H, Loh YM, Saw CL, Khalid N
    Gerodontology, 2017 Jun;34(2):276-279.
    PMID: 27384017 DOI: 10.1111/ger.12240
    OBJECTIVE: A case of oral metastatic follicular thyroid carcinoma is presented.

    BACKGROUND: Metastatic tumours are more frequent in older individuals and can be the only sign/symptom of an undiagnosed primary malignancy.

    CASE REPORT: A 69-year-old lady presented with an enlarging mandibular swelling. Incisional biopsy and imaging studies were suggestive of metastatic follicular thyroid carcinoma.

    CONCLUSION: Metastatic tumours should be considered in the differential diagnosis of mandibular swellings especially in older individuals.

    Matched MeSH terms: Biopsy
  16. Marjmin, O., Rohaizak, M., Naqiyah, I., Imtiaz, H., Hartinie, S.M.
    MyJurnal
    Primary thyroid lymphoma is a rare tumour of the thyroid gland, accounting for 1-2 % of all thyroid malignancies. Diagnosis by fine needle aspiration cytology occasionally inconclusive, needing bigger biopsy or even thyroidectomy. This study reviews our experience with primary thyroid lymphoma.
    Matched MeSH terms: Biopsy, Fine-Needle
  17. Norly, S., Razman, J.
    MyJurnal
    Hepatic adenomatosis is a rare, benign tumour of the liver. It was first described by Flejou et al as multiple adenomas in an otherwise normal liver parenchyma. Although benign, it can present as a diagnostic
    challenge because the lesions can be diffi cult to distinguish from other hepatic tumours. Patients can be
    asymptomatic and the diagnosis may only be made incidentally. We describe the case of 40-year-old Malay lady who was incidentally found to have hepatomegaly. Radiological examinations revealed a complex left ovarian cyst with multiple liver lesions. Biopsy of the liver lesion showed features of hepatic adenomatosis. Literature review was done and the dilemma in managing her was discussed.
    Matched MeSH terms: Biopsy
  18. Abdul Rahim, N.I.H., Ngah, N.A., Ramanathan, A., George, T., Ismail, S.M.
    Ann Dent, 2011;18(1):24-29.
    MyJurnal
    Osteosarcoma is a primary malignant neoplasm of the bone. Osteosarcoma of the jaws especially those of maxilla is rare. The diagnosis of osteosarcomas is difficult and challenging. In this case report we highlight a rare case of osteosarcoma of the maxilla in a 29 year old male patient which was highly aggressive and was initially diagnosed as rhabdomyosarcoma. This case highlights the difficulty in diagnosing osteosarcoma merely from incisional biopsy specimens which may not be representative of the whole tumour. Limited clinical information at incisional biopsy also adds to the difficulty in arriving at the definitive diagnosis. We further discuss the treatment modalities followed in this case.
    Matched MeSH terms: Biopsy
  19. Sharifah, M.I.A.
    MyJurnal
    Solid papillary breast carcinoma is a rare type of breast carcinoma. We present four cases which highlight the radiological and histological findings of solid papillary carcinoma. Mammogram supplemented with ultrasound played an important role in detecting solid papillary carcinomas which usually presents as intraductal lesions or intracystic mass with Doppler signal. Excision biopsy is a better option than core biopsy as the latter modality may not be representative and the diagnosis of solid papillary breast carcinoma may be missed.
    Matched MeSH terms: Biopsy, Large-Core Needle
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links