Displaying publications 21 - 30 of 30 in total

Abstract:
Sort:
  1. Constance LSL, Lansing MG, Khor FK, Muniandy RK
    BMJ Case Rep, 2017 Nov 23;2017.
    PMID: 29170175 DOI: 10.1136/bcr-2017-221659
    Administering anaesthesia for elderly patients with chronic schizophrenia has always been a great challenge to anaesthetists. These patients will usually be on multiple antipsychotic drugs for many years and may lead to delayed awakening, cardiovascular instability, arrhythmias and sudden cardiac death during general anaesthesia. This case report is about the perioperative anaesthetic management of an elderly schizophrenic patient undergoing removal of femur implant. This article will explore important drug interactions and available options for a successful anaesthesia.
    Matched MeSH terms: Device Removal/adverse effects; Device Removal/methods
  2. Afzal MR, Daoud EG, Cunnane R, Mulpuru SK, Koay A, Hussain A, et al.
    Heart Rhythm, 2018 06;15(6):841-846.
    PMID: 29427820 DOI: 10.1016/j.hrthm.2018.02.008
    BACKGROUND: Experience with retrieval of the Micra transcatheter pacing system (TPS) is limited because of its relatively newer technology. Although abandonment of the TPS at end of life is recommended, certain situations such as endovascular infection or device embolization warrant retrieval.

    OBJECTIVE: The purpose of this study was to report the worldwide experience with successful retrieval of the Micra TPS.

    METHODS: A list of all successful retrievals of the currently available leadless pacemakers (LPs) was obtained from the manufacturer of Micra TPS. Pertinent details of retrieval, such as indication, days postimplantation, equipment used, complications, and postretrieval management, were obtained from the database collected by the manufacturer. Other procedural details were obtained directly from the operators at each participating site.

    RESULTS: Data from the manufacturer consisted of 40 successful retrievals of the Micra TPS. Operators for 29 retrievals (73%) provided the consent and procedural details. Of the 29 retrievals, 11 patients underwent retrieval during the initial procedure (immediate retrieval); the other 18 patients underwent retrieval during a separate procedure (delayed retrieval). Median duration before delayed retrieval was 46 days (range 1-95 days). The most common reason for immediate retrieval was elevated pacing threshold after tether removal. The most common reasons for delayed retrieval included elevated pacing threshold at follow-up, endovascular infection, and need for transvenous device. Mean procedure duration was 63.11 ± 56 minutes. All retrievals involved snaring via a Micra TPS delivery catheter or steerable sheath. No serious complications occurred during the reported retrievals.

    CONCLUSION: Early retrieval of the Micra TPS is feasible and safe.

    Matched MeSH terms: Device Removal/methods*
  3. Nurul Ain Mohamed Yusof, Mohd Salman Masri, Erni Noor
    Compendium of Oral Science, 2018;5(1):46-53.
    MyJurnal
    Introduction: High survival rates of dental implants were commonly reported even after 10 years of follow up. Nevertheless, complications and failure may occur and the implant would need to be removed. In recent years, the use of autogenous blood products in dental surgery has increased due to its ability to aid the healing of the soft and hard tissues. Clinical case: The case demonstrated the utilisation of concentrated growth factor (CGF) from the patient’s blood for healing following conservative removal of a failed dental implant. Subsequently, the patient showed satisfactory recovery without any infections and clinical complaints. Conclusion: This explantation procedure, together with the use of CGF, may prevent the normal bone resorption and accelerate soft tissue healing. As it is biological in nature having originated from the patient’s blood, it is more readily accepted by the tissues and the risk of infection is low.
    Matched MeSH terms: Device Removal
  4. Chendran P, Seng Fai T, Wan Abdul Halim WH, Md Din N
    J Glaucoma, 2019 10;28(10):e162-e164.
    PMID: 31368915 DOI: 10.1097/IJG.0000000000001334
    Ocular pyogenic granuloma is a benign tumor seen after ocular insult secondary to ocular surgeries, trauma or infection. Although benign, intervention is sometimes necessary. Previous authors have reported pyogenic granuloma formation following oculoplastic surgeries. We report a pyogenic granuloma after an Ahmed glaucoma valve implantation. A 65-year-old gentleman presented with right eye redness associated with pain and swelling ~2 months after Ahmed glaucoma valve implantation. Examination found a sessile growth on the tube extruding puss with signs of endophthalmitis. The glaucoma drainage device was explanted and culture results grew Staphylococcus aureus. This article discusses the formation of pyogenic granuloma on a glaucoma drainage device and its management.
    Matched MeSH terms: Device Removal
  5. Ho YL, Jamaluddin MF, Krishinan S, Salleh A, Khamis AY, Abdul Kareem BA
    Asian Cardiovasc Thorac Ann, 2020 Mar;28(3):152-157.
    PMID: 32122151 DOI: 10.1177/0218492320910932
    Matched MeSH terms: Device Removal
  6. Xiao Hong C, Abd Wahab S, Azman M
    BMJ Case Rep, 2020 Oct 27;13(10).
    PMID: 33109696 DOI: 10.1136/bcr-2020-236484
    Penetrating foreign body in the head and neck can be catastrophic from injury to the constellation of vascular and neural structures in the neck. Early recognition and prompt surgical intervention is imperative to save lives. Herein, we present an unusual case of iatrogenic foreign body-a coiled guidewire embedded in the deep neck space. The complications, radiological investigation and multidisciplinary surgical management are further discussed.
    Matched MeSH terms: Device Removal/methods
  7. Rickard CM, Marsh NM, Larsen EN, McGrail MR, Graves N, Runnegar N, et al.
    Lancet, 2021 04 17;397(10283):1447-1458.
    PMID: 33865494 DOI: 10.1016/S0140-6736(21)00351-2
    BACKGROUND: The optimal duration of infusion set use to prevent life-threatening catheter-related bloodstream infection (CRBSI) is unclear. We aimed to compare the effectiveness and costs of 7-day (intervention) versus 4-day (control) infusion set replacement to prevent CRBSI in patients with central venous access devices (tunnelled cuffed, non-tunnelled, peripherally inserted, and totally implanted) and peripheral arterial catheters.

    METHODS: We did a randomised, controlled, assessor-masked trial at ten Australian hospitals. Our hypothesis was CRBSI equivalence for central venous access devices and non-inferiority for peripheral arterial catheters (both 2% margin). Adults and children with expected greater than 24 h central venous access device-peripheral arterial catheter use were randomly assigned (1:1; stratified by hospital, catheter type, and intensive care unit or ward) by a centralised, web-based service (concealed before allocation) to infusion set replacement every 7 days, or 4 days. This included crystalloids, non-lipid parenteral nutrition, and medication infusions. Patients and clinicians were not masked, but the primary outcome (CRBSI) was adjudicated by masked infectious diseases physicians. The analysis was modified intention to treat (mITT). This study is registered with the Australian New Zealand Clinical Trials Registry ACTRN12610000505000 and is complete.

    FINDINGS: Between May 30, 2011, and Dec, 9, 2016, from 6007 patients assessed, we assigned 2944 patients to 7-day (n=1463) or 4-day (n=1481) infusion set replacement, with 2941 in the mITT analysis. For central venous access devices, 20 (1·78%) of 1124 patients (7-day group) and 16 (1·46%) of 1097 patients (4-day group) had CRBSI (absolute risk difference [ARD] 0·32%, 95% CI -0·73 to 1·37). For peripheral arterial catheters, one (0·28%) of 357 patients in the 7-day group and none of 363 patients in the 4-day group had CRBSI (ARD 0·28%, -0·27% to 0·83%). There were no treatment-related adverse events.

    INTERPRETATION: Infusion set use can be safely extended to 7 days with resultant cost and workload reductions.

    FUNDING: Australian National Health and Medical Research Council.

    Matched MeSH terms: Device Removal/economics
  8. Ahmed T, Rahman NA, Alam MK
    Biomed Res Int, 2021;2021:6663683.
    PMID: 33959664 DOI: 10.1155/2021/6663683
    Objective: To compare the orthodontic bracket debonding force and assess the bracket failure pattern clinically between different teeth by a validated prototype debonding device. Materials and Method. Thirteen (13) patients at the end of comprehensive fixed orthodontic treatment, awaiting for bracket removal, were selected from the list. A total of 260 brackets from the central incisor to the second premolar in both jaws were debonded by a single clinician using a validated prototype debonding device equipped with a force sensitive resistor (FSR). Mean bracket debonding forces were specified to ten (10) groups of teeth. Following debonding, Intraoral microphotographs of the teeth were taken by the same clinician to assess the bracket failure pattern using a 4-point scale of adhesive remnant index (ARI). Statistical analysis included one-way ANOVA with post hoc Tukey HSD and independent sample t-test to compare in vivo bracket debonding force, Cohen's kappa (κ), and a nonparametric Kruskal-Wallis test for the reliability and the assessment of ARI scoring.

    Results: A significant difference (p < 0.001) of mean debonding force was found between different types of teeth in vivo. Clinically, ARI scores were not significantly different (p = 0.921) between different groups, but overall higher scores were predominant.

    Conclusion: Bracket debonding force should be measured on the same tooth from the same arch as the significant difference of mean debonding force exists between similar teeth of the upper and lower arches. The insignificant bracket failure pattern with higher ARI scores confirms less enamel damage irrespective of tooth types.

    Matched MeSH terms: Device Removal*
  9. Yii RSL, Chuah KH, Poh KS, Lau PC, Ng KL, Ho SH, et al.
    Dig Dis Sci, 2022 01;67(1):344-347.
    PMID: 33491164 DOI: 10.1007/s10620-021-06835-4
    Matched MeSH terms: Device Removal/methods*
  10. Tamin S, Shabrina F, Hutauruk SM, Rachmawati EZK, Fardizza F, Koento T, et al.
    Med J Malaysia, 2024 Mar;79(2):119-123.
    PMID: 38553913
    INTRODUCTION: Tracheostomy is a procedure commonly performed in neurocritical and mechanically ventilated patients in the intensive care unit. Dysphagia and impaired airway protection are the main causes for a delay in tracheostomy decannulation in patients with neurological disorders. Endoscopic evaluation is an objective examination of readiness for tracheostomy decannulation with flexible endoscopic evaluation of swallowing (FEES) as the most commonly used method, yet it requires special expertise and is heavily dependent on its operator in assessing the parameters. A relatively new method for assessing decannulation readiness in neurologic disorder, the Standardized Endoscopic Swallowing Evaluation for Tracheostomy Decannulation (SESETD) was introduced in 2013 by Warnecke, et al. This method includes stepwise evaluation of secretion management, spontaneous swallowing and laryngeal sensitivity. This study aims to find conformity between the SESETD and FEES in assessing readiness for tracheostomy decannulation in patients with neurologic disorders.

    MATERIALS AND METHODS: This study is a cross-sectional study conducted on 36 neurologic patients at Cipto Mangunkusumo General Hospital which was aimed to find the agreement between two modalities for tracheostomy decannulation readiness, FEES and SESETD based on parameters, standing secretion, spontaneous swallowing and laryngeal sensitivity.

    RESULT: A total of 36 subjects were examined and 22 of them underwent successful tracheostomy decannulation. The agreement between FEES and SESETD showed significant results with p-value <0.0001 and Kappa value = 0.47.

    CONCLUSION: There was conformity between FEES and SESETD in evaluating tracheostomy decannulation readiness based on three parameters: standing secretion, spontaneous swallowing and laryngeal sensitivity.

    Matched MeSH terms: Device Removal/methods