Displaying publications 21 - 40 of 50 in total

Abstract:
Sort:
  1. Lee JS, Ee ML, Chung KH, Othman Z
    Carbohydr Polym, 2013 Sep 12;97(2):614-7.
    PMID: 23911492 DOI: 10.1016/j.carbpol.2013.05.047
    The effect of gamma-irradiation on formation of resistant starch (RS) in corn starch with different amylose content was examined. Normal corn starch, waxy corn starch, and high amylose corn starch (Hylon V and Hylon VII) were irradiated at 5, 10, 25 and 50 kGy. Gamma-irradiation at 5 kGy increased the amylose-like molecules in starches and thus significantly enhanced the RS content (p<0.05). Highest RS content was produced by 50 kGy irradiated in all the starch samples (p<0.05). The irradiation-induced RS was more evident in waxy corn starch, followed by high amylose corn starch and normal corn starch.
    Matched MeSH terms: Dose-Response Relationship, Radiation
  2. Alajerami YS, Hashim S, Ramli AT, Saleh MA, Saripan MI, Alzimami K, et al.
    Appl Radiat Isot, 2013 Aug;78:21-5.
    PMID: 23644162 DOI: 10.1016/j.apradiso.2013.03.095
    New glasses Li2CO3-K2CO3-H3BO3 (LKB) co-doped with CuO and MgO, or with TiO2 and MgO, were synthesized by the chemical quenching technique. The thermoluminescence (TL) responses of LKB:Cu,Mg and LKB:Ti,Mg irradiated with 6 MV photons or 6 MeV electrons were compared in the dose range 0.5-4.0 Gy. The standard commercial dosimeter LiF:Mg,Ti (TLD-100) was used to calibrate the TL reader and as a reference in comparison of the TL properties of the new materials. The dependence of the responses of the new materials on (60)Co dose is linear in the range of 1-1000 Gy. The TL yields of both of the co-doped glasses and TLD-100 are greater for electron irradiation than for photon irradiation. The TL sensitivity of LKB:Ti,Mg is 1.3 times higher than the sensitivity of LKB:Cu,Mg and 12 times less than the sensitivity of TLD-100. The new TL dosimetric materials have low effective atomic numbers, good linearity of the dose responses, excellent signal reproducibility, and a simple glow curve structure. This combination of properties makes them suitable for radiation dosimetry.
    Matched MeSH terms: Dose-Response Relationship, Radiation
  3. Foo KY, Hameed BH
    Bioresour Technol, 2012 Sep;119:234-40.
    PMID: 22728787 DOI: 10.1016/j.biortech.2012.05.061
    Microwave heating was used in the regeneration of methylene blue-loaded activated carbons produced from fibers (PFAC), empty fruit bunches (EFBAC) and shell (PSAC) of oil palm. The dye-loaded carbons were treated in a modified conventional microwave oven operated at 2450 MHz and irradiation time of 2, 3 and 5 min. The virgin properties of the origin and regenerated activated carbons were characterized by pore structural analysis and nitrogen adsorption isotherm. The surface chemistry was examined by zeta potential measurement and determination of surface acidity/basicity, while the adsorptive property was quantified using methylene blue (MB). Microwave irradiation preserved the pore structure, original active sites and adsorption capacity of the regenerated activated carbons. The carbon yield and the monolayer adsorption capacities for MB were maintained at 68.35-82.84% and 154.65-195.22 mg/g, even after five adsorption-regeneration cycles. The findings revealed the potential of microwave heating for regeneration of spent activated carbons.
    Matched MeSH terms: Dose-Response Relationship, Radiation
  4. Lye HS, Alias KA, Rusul G, Liong MT
    Ultrason Sonochem, 2012 May;19(3):632-41.
    PMID: 21907608 DOI: 10.1016/j.ultsonch.2011.08.004
    This study aimed to evaluate the effect of ultrasound treatment on the cholesterol removing ability of lactobacilli. Viability of lactobacilli cells was significantly increased (P < 0.05) immediately after treatment, but higher intensity of 100 W and longer duration of 3 min was detrimental on cellular viability (P < 0.05). This was attributed to the disruption of membrane lipid bilayer, cell lysis and membrane lipid peroxidation upon ultrasound treatment at higher intensity and duration. Nevertheless, the effect of ultrasound on membrane properties was reversible, as the viability of ultrasound-treated lactobacilli was increased (P < 0.05) after fermentation at 37 °C for 20 h. The removal of cholesterol by ultrasound-treated lactobacilli via assimilation and incorporation of cholesterol into the cellular membrane also increased significantly (P < 0.05) upon treatment, as observed from the increased ratio of membrane C:P. Results from fluorescence anisotropies showed that most of the incorporated cholesterol was saturated in the regions of phospholipids tails, upper phospholipids, and polar heads of the membrane bilayer.
    Matched MeSH terms: Dose-Response Relationship, Radiation
  5. Shulman ST
    Pediatr Ann, 2008 Jun;37(6):368-9.
    PMID: 18616187
    Matched MeSH terms: Dose-Response Relationship, Radiation
  6. Chow MC, Ma AN
    PMID: 17645207
    Microwave heating was determined in this study to be suitable for the detachment and drying of palm fruits from whole bunches, cut bunches and spikelets. Microwave treatment of the palm fruits was able to attain the objectives of conventional fresh palm fruits sterilization processeses such as fruit softening, nut conditioning and halting of enzymatic lipolysis. Palm oil and kernel oil solvent extracted respectively from the microwave treated whole fruits and kernel were found to have a good quality of low free fatty acid content. This technology, together with the solvent extraction of the dehydrated fruits, may have the potential to be a continuous, dry and clean technology for palm oil milling.
    Matched MeSH terms: Dose-Response Relationship, Radiation
  7. Wahidin S, Idris A, Shaleh SR
    Bioresour Technol, 2013 Feb;129:7-11.
    PMID: 23232218 DOI: 10.1016/j.biortech.2012.11.032
    Illumination factors such as length of photoperiod and intensity can affect growth of microalgae and lipid content. In order to optimize microalgal growth in mass culture system and lipid content, the effects of light intensity and photoperiod cycle on the growth of the marine microalgae, Nannochloropsis sp. were studied in batch culture. Nannochloropsis sp. was grown aseptically for 9 days at three different light intensities (50, 100 and 200 μmol m(-2) s(-1)) and three different photoperiod cycles (24:0, 18:06 and 12:12 h light:dark) at 23 °C cultivation temperature. Under the light intensity of 100 μmol m(-2) s(-1) and photoperiod of 18 h light: 6 h dark cycle, Nannochloropsis sp. was found to grow favorably with a maximum cell concentration of 6.5×10(7) cells mL(-1), which corresponds to the growth rate of 0.339 d(-1) after 8 day cultivation and the lipid content was found to be 31.3%.
    Matched MeSH terms: Dose-Response Relationship, Radiation
  8. Iskandar SM, Elias S, Jumiah H, Asri MT, Masrianis A, Ab Rahman MZ, et al.
    Med J Malaysia, 2004 May;59 Suppl B:212-3.
    PMID: 15468893
    The radiation-response characteristics of polymetharylic acid gel dosimeter prepared with different concentrations of monomer and cross-linker is described in these studies. The dosimeters were prepared under the hypoxic condition in a glove box and were then irradiated with gamma-rays produced by Co-60 radionuclide that was generated at 1.25MeV energy. The irradiation took place at different doses ranged from 0Gy to 19Gy. Due to the radiation activities, chain-reaction polymerisation processes had taken place in the formation of polymethacrylic acid (PMAA) gel, which cause the dose response mechanism increased in the NMR relaxation rates of protons. It has been observed that for higher concentration of monomer and cross-linker, the polymerization rate was increased.
    Matched MeSH terms: Dose-Response Relationship, Radiation
  9. Mohd Asri MT, Elias S, Iskandar SM, Abd Halim S, Jumiah H, Zaki AR, et al.
    Med J Malaysia, 2004 May;59 Suppl B:139-40.
    PMID: 15468857
    The aim of this work was to study radiation and the effects of temperature on conductivity properties of polyvinyl alcohol (PVA)-based potassium hydroxide (KOH) and propylene carbonate (PC), where the ionic conduction preferentially occurs in the amorphous phase by free radicals ions through gamma-irradiation. Alkaline composite polymer electrolyte (ACPE) consisting of PVA, KOH and PC of different concentration ratios were prepared by solvent-casting technique. The ACPE were irradiated with different doses from 5 kGy up to 200 kGy. The conductivity properties of the electrolyte films were measured at different frequencies in the range 20 Hz to 1 MHz using LCR meter. The results showed that the conductivity properties were dependent on the radiation dose, temperature and the concentration of the polymer blends.
    Matched MeSH terms: Dose-Response Relationship, Radiation
  10. Al-jarrah AM, Abdul Rahman A, Shahrim I, Razak NN, Ababneh B, Tousi ET
    Phys Med, 2016 Jan;32(1):36-41.
    PMID: 26494156 DOI: 10.1016/j.ejmp.2015.09.003
    Genipin gel dosimeters are hydrogels infused with a radiation-sensitive material which yield dosimetric information in three dimensions (3D). The effect of inorganic salts and glucose on the visible absorption dose-response, melting points and mass density of genipin gel dosimeters has been experimentally evaluated using 6-MV LINAC photons. As a result, the addition of glucose with optimum concentration of 10% (w/w) was found to improve the thermal stability of the genipin gel and increase its melting point (Tm) by 6 °C accompanied by a slight decrease of dose-response. Furthermore, glucose helps to adjust the gel mass density to obtain the desired tissue-equivalent properties. A drop of Tm was observed when salts were used as additives. As the salt concentration increased, gel Tm decreased. The mass density and melting point of the genipin gel could be adjusted using different amounts of glucose that improved the genipin gel suitability for 3D dose measurements without introducing additional toxicity to the final gel.
    Matched MeSH terms: Dose-Response Relationship, Radiation
  11. Ibahim MJ, Crosbie JC, Paiva P, Yang Y, Zaitseva M, Rogers PA
    Radiat Environ Biophys, 2016 May;55(2):185-94.
    PMID: 26994995 DOI: 10.1007/s00411-016-0641-x
    The xCELLigence real-time cell impedance system uses a non-invasive and label-free method to create a cell index that is a composite measure of cell proliferation. The aim of this study was to evaluate xCELLigence against clonogenic assay (gold standard) for measuring radiobiological effects and radiation-induced bystander effects (RIBE). A radiobiological study was conducted by irradiating EMT6.5, 4T1.2 and NMUMG cell lines with different radiation doses, while a RIBE study was done using transfer of conditioned media (CM) harvested from donor to the same type of recipient cell (EMT6.5, 4T1.2, NMUMG, HACAT and SW48). CM was harvested using two protocols which differed in the dose chosen and the exposure to the recipient cells. Results showed that xCELLigence measured a radiobiological effect which correlated with the clonogenic assay. For the RIBE study, no statistically significant differences were observed between xCELLigence or clonogenic survival in control or recipient cells incubated with CM in protocol one. However, there was a significant increase in cell index slope using CM from EMT-6.5 cells irradiated at 7.5 Gy compared with the control group under the second protocol. No other evidence of RIBE was detected by either xCELLigence or clonogenic assay. In conclusion, xCELLigence methods can measure radiobiological effects and the results correlate with clonogenic assay. We observed a lack of RIBE in all tested cell lines with the clonogenic assay; however, we observed a RIBE effect in EMT6.5 cells under one particular protocol that showed RIBE is cell type dependent, is not universally observed and can be detected in different assays.
    Matched MeSH terms: Dose-Response Relationship, Radiation
  12. Safari MJ, Wong JH, Ng KH, Jong WL, Cutajar DL, Rosenfeld AB
    Med Phys, 2015 May;42(5):2550-8.
    PMID: 25979047 DOI: 10.1118/1.4918576
    The MOSkin is a MOSFET detector designed especially for skin dose measurements. This detector has been characterized for various factors affecting its response for megavoltage photon beams and has been used for patient dose measurements during radiotherapy procedures. However, the characteristics of this detector in kilovoltage photon beams and low dose ranges have not been studied. The purpose of this study was to characterize the MOSkin detector to determine its suitability for in vivo entrance skin dose measurements during interventional radiology procedures.
    Matched MeSH terms: Dose-Response Relationship, Radiation
  13. Farayola MF, Shafie S, Mohd Siam F, Khan I
    Comput Methods Programs Biomed, 2020 Apr;187:105202.
    PMID: 31835107 DOI: 10.1016/j.cmpb.2019.105202
    Background This paper presents a numerical simulation of normal and cancer cells' population dynamics during radiotherapy. The model used for the simulation was the improved cancer treatment model with radiotherapy. The model simulated the population changes during a fractionated cancer treatment process. The results gave the final populations of the cells, which provided the final volumes of the tumor and normal cells. Method The improved model was obtained by integrating the previous cancer treatment model with the Caputo fractional derivative. In addition, the cells' population decay due to radiation was accounted for by coupling the linear-quadratic model into the improved model. The simulation of the treatment process was done with numerical variables, numerical parameters, and radiation parameters. The numerical variables include the populations of the cells and the time of treatment. The numerical parameters were the model factors which included the proliferation rates of cells, competition coefficients of cells, and perturbation constant for normal cells. The radiation parameters were clinical data based on the treatment procedure. The numerical parameters were obtained from the previous literature while the numerical variables and radiation parameters, which were clinical data, were obtained from reported data of four cancer patients treated with radiotherapy. The four cancer patients had tumor volumes of 28.4 cm3, 18.8 cm3, 30.6 cm3, and 12.6 cm3 and were treated with different treatment plans and a fractionated dose of 1.8 Gy each. The initial populations of cells were obtained by using the tumor volumes. The computer simulations were done with MATLAB. Results The final volumes of the tumors, from the results of the simulations, were 5.67 cm3, 4.36 cm3, 5.74 cm3, and 6.15 cm3 while the normal cells' volumes were 28.17 cm3, 18.68 cm3, 30.34 cm3, and 12.54 cm3. The powers of the derivatives were 0.16774, 0.16557, 0.16835, and 0.16. A variance-based sensitivity analysis was done to corroborate the model with the clinical data. The result showed that the most sensitive factors were the power of the derivative and the cancer cells' proliferation rate. Conclusion The model provided information concerning the status of treatments and can also predict outcomes of other treatment plans.
    Matched MeSH terms: Dose-Response Relationship, Radiation
  14. Mohd S, Ghazali MI, Yusof N, Sulaiman S, Ramalingam S, Kamarul T, et al.
    Cell Tissue Bank, 2018 Dec;19(4):613-622.
    PMID: 30056604 DOI: 10.1007/s10561-018-9711-4
    Air-dried and sterilized amnion has been widely used as a dressing to treat burn and partial thickness wounds. Sterilisation at the standard dose of 25 kGy was reported to cause changes in the morphological structure as observed under the scanning electron microscope. This study aimed to quantify the changes in the ultrastructure of the air-dried amnion after gamma-irradiated at several doses by using atomic force microscope. Human placentae were retrieved from mothers who had undergone cesarean elective surgery. Amnion separated from chorion was processed and air-dried for 16 h. It was cut into 10 × 10 mm, individually packed and exposed to gamma irradiation at 5, 15, 25 and 35 kGy. Changes in the ultrastructural images of the amnion were quantified in term of diameter of the epithelial cells, size of the intercellular gap and membrane surface roughness. The longest diameter of the amnion cells reduced significantly after radiation (p dose dependent. No significant changes in the shortest diameter after radiation, except at 35 kGy which decreased significantly when compared to 5 kGy (p 
    Matched MeSH terms: Dose-Response Relationship, Radiation
  15. Sabarudin A, Siong TW, Chin AW, Hoong NK, Karim MKA
    Sci Rep, 2019 03 13;9(1):4374.
    PMID: 30867480 DOI: 10.1038/s41598-019-40758-5
    In this report we have evaluated radiation effective dose received by patients during ECG-gated CCTA examinations based on gender, heart rate, tube voltage protocol and body mass index (BMI). A total of 1,824 patients were retrospectively recruited (1,139 men and 685 women) and they were divided into Group 1 (CCTA with calcium scoring), Group 2 (CCTA without calcium scoring) and Group 3 (only calcium scoring), where the association between gender, heart rate, tube voltage protocol and body mass index (BMI) were analysed. Examinations were performed using a retrospective ECG-gated CCTA protocol and the effective doses were calculated from the dose length product with a conversion coefficient of 0.026 mSv.mGy-1cm-1. No significant differences were observed in the mean effective dose between gender in all groups. The mean estimated dose was significantly higher when the heart rate was lower in Group 1 (p dose in tube voltage protocol and BMI among the three groups. The mean effective dose was positively correlated with BMI (p dose exposure.
    Matched MeSH terms: Dose-Response Relationship, Radiation
  16. Parate D, Franco-Obregón A, Fröhlich J, Beyer C, Abbas AA, Kamarul T, et al.
    Sci Rep, 2017 08 25;7(1):9421.
    PMID: 28842627 DOI: 10.1038/s41598-017-09892-w
    Pulse electromagnetic fields (PEMFs) have been shown to recruit calcium-signaling cascades common to chondrogenesis. Here we document the effects of specified PEMF parameters over mesenchymal stem cells (MSC) chondrogenic differentiation. MSCs undergoing chondrogenesis are preferentially responsive to an electromagnetic efficacy window defined by field amplitude, duration and frequency of exposure. Contrary to conventional practice of administering prolonged and repetitive exposures to PEMFs, optimal chondrogenic outcome is achieved in response to brief (10 minutes), low intensity (2 mT) exposure to 6 ms bursts of magnetic pulses, at 15 Hz, administered only once at the onset of chondrogenic induction. By contrast, repeated exposures diminished chondrogenic outcome and could be attributed to calcium entry after the initial induction. Transient receptor potential (TRP) channels appear to mediate these aspects of PEMF stimulation, serving as a conduit for extracellular calcium. Preventing calcium entry during the repeated PEMF exposure with the co-administration of EGTA or TRP channel antagonists precluded the inhibition of differentiation. This study highlights the intricacies of calcium homeostasis during early chondrogenesis and the constraints that are placed on PEMF-based therapeutic strategies aimed at promoting MSC chondrogenesis. The demonstrated efficacy of our optimized PEMF regimens has clear clinical implications for future regenerative strategies for cartilage.
    Matched MeSH terms: Dose-Response Relationship, Radiation
  17. Alyahyawi A, Jupp T, Alkhorayef M, Bradley DA
    Appl Radiat Isot, 2018 Aug;138:45-49.
    PMID: 28780202 DOI: 10.1016/j.apradiso.2017.07.011
    In the modern clinical practice of diagnostic radiology there is a growing demand for radiation dosimetry, it also being recognized that with increasing use of X-ray examinations additional population dose will result, accompanied by an additional albeit low potential for genetic consequences. At the doses typical of diagnostic radiology there is also a low statistical risk for cancer induction; in adhering to best practice, to be also implied is a low but non-negligible potential for deterministic sensitive organ responses, including in regard to the skin and eyes. Risk reduction is important, in line with the principle of ALARP, both in regard to staff and patients alike; for the latter modern practice is usually guided by Dose Reference Levels (DRL) while for the former and members of the public, legislated controls (supported by safe working practices) pertain. As such, effective, reliable and accurate means of dosimetry are required in support of these actions. Recent studies have shown that Ge-doped-silica glass fibres offer several advantages over the well-established phosphor-based TL dosimeters (TLD), including excellent sensitivity at diagnostic doses as demonstrated herein, low fading, good reproducibility and re-usability, as well as representing a water impervious, robust dosimetric system. In addition, these silica-based fibres show good linearity over a wide dynamic range of dose and dose-rate and are directionally independent. In the present study, we investigate tailor made doped-silica glass thermoluminescence (TL) for applications in medical diagnostic imaging dosimetry. The aim is to develop a dosimeter of sensitivity greater than that of the commonly used LiF (Mg,Ti) phosphor. We examine the ability of such doped glass media to detect the typically low levels of radiation in diagnostic applications (from fractions of a mGy through to several mGy or more), including, mammography and dental radiology, use being made of x-ray tubes located at the Royal Surrey County Hospital. We further examine dose-linearity, energy response and fading.
    Matched MeSH terms: Dose-Response Relationship, Radiation
  18. Al Musawi MS, Jaafar MS, Al-Gailani B, Ahmed NM, Suhaimi FM
    Lasers Med Sci, 2017 Dec;32(9):2089-2095.
    PMID: 28967036 DOI: 10.1007/s10103-017-2340-5
    The study of the effects of low-level laser (LLL) radiation on blood is important for elucidating the mechanisms behind the interaction of LLL radiation and biologic tissues. Different therapy methods that involve blood irradiation have been developed and used for clinical purposes with beneficial effects. The aim of this study was to compare the effects of different irradiation protocols using a diode-pumped solid-state LLL (λ = 405 nm) on samples of human blood by measuring the erythrocyte sedimentation rate (ESR). Human blood samples were obtained through venipuncture into tubes containing EDTA as an anticoagulant. Every sample was divided into two equal aliquots to be used as an irradiated sample and a non-irradiated control sample. The irradiated aliquot was subjected to a laser beam with a wavelength of 405 nm and an energy density of 72 J/cm2. The radiation source had a fixed irradiance of 30 mW/cm2. The ESR change was observed for three different experimental protocols: irradiated whole blood, irradiated red blood cells (RBCs) samples re-suspended in non-irradiated blood plasma, and non-irradiated RBCs re-suspended in irradiated blood plasma. The ESR values were measured after laser irradiation and compared with the non-irradiated control samples. Irradiated blood plasma in which non-radiated RBCs were re-suspended was found to result in the largest ESR decrease for healthy human RBCs, 51%, when compared with RBCs re-suspended in non-irradiated blood plasma. The decrease in ESR induced by LLL irradiation of the plasma alone was likely related to changes in the plasma composition and an increase in the erythrocyte zeta potential upon re-suspension of the RBCs in the irradiated blood plasma.
    Matched MeSH terms: Dose-Response Relationship, Radiation
  19. Alsadig AA, Abbas S, Kandaiya S, Ashikin NARNN, Qaeed MA
    Appl Radiat Isot, 2017 Nov;129:130-134.
    PMID: 28843699 DOI: 10.1016/j.apradiso.2017.08.021
    Phantoms are devices that simulate human tissues including soft tissues, lungs, and bones in medical and health physics. The purpose of this work was to investigate the differential dose absorption in several commercially available low-cost materials as substitutes to human tissues using Gafchromic XR-QA2 film. The measurement of absorbed dose by different materials of various densities was made using the film to establish the relationship between the absorbed dose and the material density. Materials investigated included soft board materials, Perspex, chicken bone, Jeltrate, chalk, cow bone, marble, and aluminum, which have varying densities from 0.26 to 2.67gcm-3. The absorbed dose increased as the density and atomic number of the material increased. The absorbed dose to the density can be well represented by a polynomial function for the materials used.
    Matched MeSH terms: Dose-Response Relationship, Radiation
  20. Entezam A, Khandaker MU, Amin YM, Ung NM, Bradley DA, Maah J, et al.
    PLoS One, 2016;11(5):e0153913.
    PMID: 27149115 DOI: 10.1371/journal.pone.0153913
    Study has been made of the thermoluminescence (TL) response of silica-based Ge-doped cylindrical, flat and photonic crystal fibres (referred to herein as PCF-collapsed) to electron (6, 12 and 20 MeV) and photon (6, 10 MV) irradiation and 1.25 MeV γ-rays, for doses from 0.1 Gy to 100 Gy. The electron and photon irradiations were delivered through use of a Varian Model 2100C linear accelerator located at the University of Malaya Medical Centre and γ-rays delivered from a 60Co irradiator located at the Secondary Standard Dosimetry Laboratory (SSDL), Malaysian Nuclear Agency. Tailor-made to be of various dimensions and dopant concentrations (6-10% Ge), the fibres were observed to provide TL yield linear with radiation dose, reproducibility being within 1-5%, with insensitivity to energy and angular variation. The sensitivity dependency of both detectors with respect to field size follows the dependency of the output factors. For flat fibres exposed to 6 MV X-rays, the 6% Ge-doped fibre provided the greatest TL yield while PCF-collapsed showed a response 2.4 times greater than that of the 6% Ge-doped flat fibres. The response of cylindrical fibres increased with core size. The fibres offer uniform response, high spatial resolution and sensitivity, providing the basis of promising TL systems for radiotherapy applications.
    Matched MeSH terms: Dose-Response Relationship, Radiation