Displaying publications 21 - 32 of 32 in total

Abstract:
Sort:
  1. Garweg C, Khelae SK, Steinwender C, Chan JYS, Ritter P, Johansen JB, et al.
    Heart Rhythm, 2020 12;17(12):2037-2045.
    PMID: 32717315 DOI: 10.1016/j.hrthm.2020.07.024
    BACKGROUND: The MARVEL (Micra Atrial TRacking Using a Ventricular AccELerometer) 2 study assessed the efficacy of atrioventricular (AV) synchronous pacing with a Micra leadless pacemaker. Average atrioventricular synchrony (AVS) was 89.2%. Previously, low amplitude of the Micra-sensed atrial signal (A4) was observed to be a factor of low AVS.

    OBJECTIVE: The purpose of this study was to identify predictors of A4 amplitude and high AVS.

    METHODS: We analyzed 64 patients enrolled in MARVEL 2 who had visible P waves on electrocardiogram for assessing A4 amplitude and 40 patients with third-degree AV block for assessing AVS at rest. High AVS was defined as >90% correct atrial-triggered ventricular pacing. The association between clinical factors and echocardiographic parameters with A4 amplitude was investigated using a multivariable model with lasso variable selection. Variables associated with A4 amplitude together with premature ventricular contraction burden, sinus rate, and sinus rate variability (standard deviation of successive differences of P-P intervals [SDSD]) were assessed for association with AVS.

    RESULTS: In univariate analysis, low A4 amplitude was inversely related to atrial function assessed by E/A ratio and e'/a' ratio, and was directly related to atrial contraction excursion (ACE) and atrial strain (Ɛa) on echocardiography (all P ≤.05). The multivariable lasso regression model found coronary artery bypass graft history, E/A ratio, ACE, and Ɛa were associated with low A4 amplitude. E/A ratio and SDSD were multivariable predictors of high AVS, with >90% probability if E/A <0.94 and SDSD <5 bpm.

    CONCLUSION: Clinical parameters and echocardiographic markers of atrial function are associated with A4 signal amplitude. High AVS can be predicted by E/A ratio <0.94 and low sinus rate variability at rest.

    Matched MeSH terms: Pacemaker, Artificial*
  2. Lloyd M, Reynolds D, Sheldon T, Stromberg K, Hudnall JH, Demmer WM, et al.
    Heart Rhythm, 2017 02;14(2):200-205.
    PMID: 27871854 DOI: 10.1016/j.hrthm.2016.11.016
    BACKGROUND: The Micra transcatheter pacemaker was designed to have similar functionality to conventional transvenous VVIR pacing systems. It provides rate adaptive pacing using a programmable 3-axis accelerometer designed to detect patient activity in the presence of cardiac motion.

    OBJECTIVE: The purpose of this study was to evaluate the system's performance during treadmill tests to maximum exertion in a subset of patients within the Micra Transcatheter Pacing Study.

    METHODS: Patients underwent treadmill testing at 3 or 6 months postimplant with algorithm programming at physician discretion. Normalized sensor rate (SenR) relative to the programmed upper sensor rate was modeled as a function of normalized workload in metabolic equivalents (METS) relative to maximum METS achieved during the test. A normalized METS and SenR were determined at the end of each 1-minute treadmill stage. The proportionality of SenR to workload was evaluated by comparing the slope from this relationship to the prospectively defined tolerance margin (0.65-1.35).

    RESULTS: A total of 69 treadmill tests were attempted by 42 patients at 3 and 6 months postimplant. Thirty tests from 20 patients who completed ≥4 stages with an average slope of 0.86 (90% confidence interval 0.77-0.96) confirmed proportionality to workload. On an individual test basis, 25 of 30 point estimates (83.3%) had a normalized slope within the defined tolerance range (range 0.46-1.08).

    CONCLUSION: Accelerometer-based rate adaptive pacing was proportional to workload, thus confirming rate adaptive pacing commensurate to workload is achievable with an entirely intracardiac pacing system.

    Matched MeSH terms: Pacemaker, Artificial*
  3. Chan RS, Abdul Aziz YF, Chandran P, Ng EK
    Singapore Med J, 2011 Nov;52(11):e232-5.
    PMID: 22173263
    A 62 year-old woman who presented with an atraumatic acute abdomen was discovered to have haemoperitoneum with splenic rupture on urgent computed tomography and was immediately referred for life-saving emergency splenectomy. Histopathological examination revealed secondary splenic amyloidosis. The patient was later found to be suffering from infective endocarditis secondary to her permanent cardiac pacemaker. This report describes a patient who could have suffered from a long-standing infected vegetation on a permanent cardiac pacemaker, which led to splenic amyloidosis and spontaneous splenic rupture.
    Matched MeSH terms: Pacemaker, Artificial/adverse effects
  4. Chinitz L, Ritter P, Khelae SK, Iacopino S, Garweg C, Grazia-Bongiorni M, et al.
    Heart Rhythm, 2018 09;15(9):1363-1371.
    PMID: 29758405 DOI: 10.1016/j.hrthm.2018.05.004
    BACKGROUND: Micra is a leadless pacemaker that is implanted in the right ventricle and provides rate response via a 3-axis accelerometer (ACC). Custom software was developed to detect atrial contraction using the ACC enabling atrioventricular (AV) synchronous pacing.

    OBJECTIVE: The purpose of this study was to sense atrial contractions from the Micra ACC signal and provide AV synchronous pacing.

    METHODS: The Micra Accelerometer Sensor Sub-Study (MASS) and MASS2 early feasibility studies showed intracardiac accelerations related to atrial contraction can be measured via ACC in the Micra leadless pacemaker. The Micra Atrial TRacking Using A Ventricular AccELerometer (MARVEL) study was a prospective multicenter study designed to characterize the closed-loop performance of an AV synchronous algorithm downloaded into previously implanted Micra devices. Atrioventricular synchrony (AVS) was measured during 30 minutes of rest and during VVI pacing. AVS was defined as a P wave visible on surface ECG followed by a ventricular event <300 ms.

    RESULTS: A total of 64 patients completed the MARVEL study procedure at 12 centers in 9 countries. Patients were implanted with a Micra for a median of 6.0 months (range 0-41.4). High-degree AV block was present in 33 patients, whereas 31 had predominantly intrinsic conduction during the study. Average AVS during AV algorithm pacing was 87.0% (95% confidence interval 81.8%-90.9%), 80.0% in high-degree block patients and 94.4% in patients with intrinsic conduction. AVS was significantly greater (P

    Matched MeSH terms: Pacemaker, Artificial*
  5. Alkhorayef M, Sulieman A, Babikir E, Daar E, Alnaaimi M, Alduaij M, et al.
    Appl Radiat Isot, 2018 Aug;138:14-17.
    PMID: 28830729 DOI: 10.1016/j.apradiso.2017.08.010
    A pacemaker, which is used for heart resynchronization with electrical impulses, is used to manage many clinical conditions. Recently, the frequency of pacemaker implantation procedures has increased to more than 50% worldwide. During this procedure, patients can be exposed to excessive radiation exposure. Wide range of doses has been reported in previous studies, suggesting that optimization of this procedure has not been fulfilled yet. The current study evaluated patient radiation exposure during cardiac pacemaker procedures and quantified the patient effective dose. A total of 145 procedures were performed for five pacemaker procedures (VVI, VVIR, VVD, VVDR, and DDDR) at two hospitals. Patient doses were measured using the kerma-area product meter. Effective doses were estimated using software based on Monte Carlo simulation from the National Radiological Protection Board (NRPB, now The Health Protection Agency). The effective dose values were used to estimate cancer risk from the pacemaker procedure. Patient demographic data and exposure parameters for fluoroscopy and radiography were quantified. The mean patient doses ± SD per procedure (Gycm2) for VVI, VVIR, VVD, VVDR, and DDDR were 1.52 ± 0.13 (1.43-1.61), 3.28 ± 2.34 (0.29-8.73), 3.04 ± 1.67 (1.57-4.86), 6.04 ± 2.326 3.29-8.58), and 8.8 ± 3.6 (4.5-26.20), respectively. The overall patient effective dose was 1.1mSv per procedure. It is obvious that the DDDR procedure exposed patients to the highest radiation dose. Patient dose variation can be attributed to procedure type, exposure parameter settings, and fluoroscopy time. The results of this study showed that patient doses during different pacemaker procedures are lower compared to previous reported values. Patient risk from pacemaker procedure is low, compared to other cardiac interventional procedures. Patients' exposures were mainly influenced by the type of procedures and the clinical indication.
    Matched MeSH terms: Pacemaker, Artificial*
  6. Sadiq MA, Azman W, Abidin IZ
    J Invasive Cardiol, 2012 Jan;24(1):E13-5.
    PMID: 22210591
    Permanent complete heart block (CHB) secondary to the loss of first septal perforator after percutaneous coronary intervention (PCI) of the left descending artery (LAD) is an extremely rare complication. We describe a case report where a patient underwent PCI of proximal LAD, complicated by loss of first septal perforator, septal infarction, and bifasicular block, which progressed to symptomatic delayed CHB. One week later, the patient required implantation of a permanent pacemaker following failure to wean off the transvenous temporary pacing maker.
    Matched MeSH terms: Pacemaker, Artificial
  7. Siew KSW, Tan MP, Hilmi IN, Loch A
    BMC Cardiovasc Disord, 2019 08 07;19(1):191.
    PMID: 31391000 DOI: 10.1186/s12872-019-1174-4
    BACKGROUND: Swallow or deglutition syncope is an unusual type of neurally-mediated syncope associated with life-threatening bradyarrhythmia and hypotension. It is a difficult condition to diagnose with commonly delayed diagnosis and management. There is lack of review articles that elucidate the basic demographics, clinical characteristics and management of this rare condition. This publication systematically reviews the 101 case reports published since 1793 on swallow syncope.

    CASE PRESENTATION: A 59-year-old man presented with the complaint of recurrent dizziness associated with meals. A 24-h ambulatory ECG recording confirmed an episode of p-wave asystole at the time of food intake. Oesophagogastroduodenoscopy with balloon inflation in the mid to lower oesophagus resulted in a 5.6 s sinus pause. The patient's symptoms resolved completely following insertion of a permanent dual chamber pacemaker.

    CONCLUSIONS: Swallow syncope is extremely rare, but still needs to be considered during diagnostic workup. It is commonly associated with gastro-intestinal disease. Permanent pacemaker implantation is the first line treatment.

    Matched MeSH terms: Pacemaker, Artificial
  8. Flaherty G, De Freitas S
    Ir Med J, 2016 Dec 12;109(10):486.
    PMID: 28644591
    Cardiovascular disease is the leading cause of death in adult international travellers. Patients living with heart disease should receive specific, individualised pre-travel health advice. The purpose of this article is to provide evidence-based advice to physicians who are consulted by travellers with cardiovascular disease. Fitness-to-travel evaluation will often be conducted by the general practitioner but other medical specialists may also be consulted for advice. Patients with chronic medical conditions should purchase travel health insurance. The general pre-travel health consultation addresses food and water safety, insect and animal bite avoidance, malaria chemoprophylaxis, and travel vaccinations. Patients with devices such as cardiac pacemakers should be familiar with how these may be affected by travel. Cardiac medications may cause adverse effects in cold or hot environments, and specific precautions must be followed by anticoagulated travellers. The physician should be aware of how to access medical care abroad, and of the potential for imported tropical diseases in returned travellers.
    Matched MeSH terms: Pacemaker, Artificial
  9. Wong TS, Abu Bakar J, Chee KH, Hasan MS, Chung WH, Chiu CK, et al.
    Spine (Phila Pa 1976), 2019 02 15;44(4):E252-E257.
    PMID: 30086081 DOI: 10.1097/BRS.0000000000002828
    STUDY DESIGN: Case report.

    OBJECTIVE: To describe the technical difficulties on performing posterior spinal fusion (PSF) on a pacemaker-dependent patient with complete congenital heart block and right thoracic scoliosis.

    SUMMARY OF BACKGROUND DATA: Congenital complete heart block requires pacemaker implantation at birth through thoracotomy, which can result in scoliosis. Corrective surgery in this patient was challenging. Height gain after corrective surgery may potentially cause lead dislodgement. The usage of monopolar electrocautery may interfere with the function of the implanted cardiac device.

    METHODS: A 17-year-old boy was referred to our institution for the treatment of right thoracic scoliosis of 70°. He had underlying complete congenital heart block secondary to maternal systemic lupus erythematosus. Pacemaker was implanted through thoracotomy since birth and later changed for four times. PSF was performed by two attending surgeons with a temporary pacing inserted before the surgery. The monopolar electrocautery device was used throughout the surgery.

    RESULTS: The PSF was successfully performed without any technical issues and complications. Postoperatively, his permanent pacemaker was functioning normally. Three days later, he was recovering well and was discharged home from hospital.

    CONCLUSION: This case indicates that PSF can be performed successfully with thoughtful anticipation of technical difficulties on a pacemaker-dependent patient with underlying congenital heart block.

    LEVEL OF EVIDENCE: 5.

    Matched MeSH terms: Pacemaker, Artificial
  10. Nor Hidayah ZA, Azerin O, Mohd Nazri A
    Med J Malaysia, 2018 10;73(5):323-325.
    PMID: 30350813 MyJurnal
    Acute Rheumatic fever (ARF) is commonly associated with ECG abnormalities particularly atrioventricular block. However, third degree atrioventricular block or complete heart block is a rare manifestation. Most cases occurred in children. We reported a 25 year old man who developed complete heart block during an acute episode of ARF. He presented to hospital with five days history of fever, malaise and migrating arthralgia, followed by pleuritic chest pain. One day after admission his electrocardiogram (ECG) revealed complete heart block. Transthoracic echocardiography showed good left ventricular function with thickened, mild mitral regurgitation with minimal pericardial effusion. ASOT titer was positive with elevated white blood count and acute phase reactant. A temporary pacemaker was inserted in view of symptomatic bradycardia. The complete heart block resolved after medical therapy. He was successfully treated with penicillin, steroid and aspirin. He was discharged well with oral penicillin. The rarity of this presentation is highlighted.
    Matched MeSH terms: Pacemaker, Artificial
  11. Yew KL, Anderson S, Farah R, Lim SH
    Asian Cardiovasc Thorac Ann, 2014 Oct;22(8):979-80.
    PMID: 24887840 DOI: 10.1177/0218492313491583
    Central vein stenosis is not uncommon in hemodialysis-dependent patients as a result of mechanical damage to the vessel walls from prior cannulation. It can cause ipsilateral upper limb swelling and pain, resulting in suboptimal hemodialysis. It is unfortunate for bilateral central vein stenosis to develop concomitantly, and rare in the setting of an in-situ pacemaker. This case illustrates the successful ligation of a nondependent left arteriovenous fistula and stenting of the right subclavian vein with functioning ipsilateral arteriovenous fistula, to overcome the problem of symptomatic bilateral upper limb swelling.
    Matched MeSH terms: Pacemaker, Artificial/adverse effects*
  12. Rai V, Shariffuddin II, Chan YK, Muniandy RK, Wong KK, Singh S
    BMC Anesthesiol, 2014;14:49.
    PMID: 25002831 DOI: 10.1186/1471-2253-14-49
    BACKGROUND: Complete heart block in pregnancy has serious implications particularly during the period of delivery. This is more so if the delivery is an operative one as the presence of heart block may produce haemodynamic instability in the intra operative period. We report a unique case of a pregnant mother with complete heart block undergoing hysterostomy, complicated by placenta accreta and intrauterine death.

    CASE PRESENTATION: A 37 year old Malaysian Chinese parturient was admitted at 25 weeks gestation following a scan which suggested intrauterine death and placenta accreta. She was diagnosed to have congenital complete heart block after her first delivery eight years previously but a pacemaker was never inserted. These medical conditions make her extremely likely to experience massive bleeding and haemodynamic instability. Among the measures taken to optimise her pre-operatively were the insertion of a temporary intravenous pacemaker and embolization of the uterine arteries to minimize peri-operative blood loss. She successfully underwent surgery under general anesthesia, which was relatively uneventful and was discharged well on the fourth post-operative day.

    CONCLUSION: Congenital heart block in pregnancies in the presence of potential massive bleeding is best managed by a team, with meticulous pre-operative optimization. Suggested strategies would include insertion of a temporary pacemaker and embolization of the uterine arteries to reduce the risk of the patient getting into life threatening situations.

    Matched MeSH terms: Pacemaker, Artificial