There has been much progress made in the management of peripheral arterial disease (PAD) in the past two decades. Progress in the understanding of the endothelial-platelet interaction during health and disease state have resulted in better antiplatelet drugs that can prevent platelet aggregation, activation and thrombosis during angioplasty and stenting. Collaborative effort by different international societies has resulted in a consensus guideline that recommends the modality of intervention in certain disease states. Progress in perioperative care has reduced the morbidity and mortality associated with peripheral vascular reconstruction surgery. Nevertheless, the advances in percutaneous peripheral intervention (PPI) have made a paradigm shift in the current management of patients. The procedure is safe and effective and is emerging as the first choice revascularization procedure.
Conventional open repair for Thoracoabdominal aortic aneurysm (TAA) is associated with high morbidity and mortality. Spinal cord ischemia (SCI), renal failure, bowel ischemia and mortality are established complications following this procedure. With the advent of endovascular stent technology, various novel approaches have been described to reduce these complications, namely fenestrated stent graft and hybrid procedure. We present a case of hybrid procedure in a pseudoaneurysm of descending thoracic aorta done in Kuala Lumpur Hospital.
Good suspension lessens the pistoning (vertical displacement) of the residual limb inside the prosthetic socket. Several methods are used for measuring the pistoning.
The effect of the duration of ischaemic myocardial time to left ventricular ejection fraction (LVEF) after valve replacement surgery has been attributed. This study aims to look at the correlation between myocardial ischaemic time and changes LVEF post valve replacement surgery up to 6 months period.
Tumour surgery for locally extensive malignant neoplasms of the extremity will sometimes result in extensive composite soft tissue defect. Local flaps are usually inadequate to cover these large defects. More than one tissue flap might be required to cover any exposed neurovascular structures, bone or prosthesis. We present two cases where two composite flaps were simultaneously used to cover extensive surgical defects after ablative tumour resections in the extremity. These resulted in uncomplicated wound healing and limb salvage.
Papillary fibroelastoma is a rare primary tumor of the heart valves. This lesion can occur on any of the valves or endothelial surface of the heart and has been detected by echocardiography, by cardiac catheterization, during open heart operations for other conditions, and at autopsy. Because of the potential for comorbidities, this tumor should be removed. We present the case of an elderly man with a diagnosis of severe mitral valve regurgitation and moderate tricuspid valve regurgitation who was suspected to have a tricuspid valve vegetation. Mitral valve replacement, tricuspid valve repair, and excision of the lesion were performed successfully. A histologic examination of the vegetation confirmed it to be a papillary fibroelastoma. We present this case to emphasize the rarity of this tumor and the importance of a correct diagnosis to avoid delaying its prompt and definitive management.
A 68 year old man with significant cardiorespiratory risks factors presented with a ruptured thoracic aortic aneurysm (TAA). This was treated by emergency thoracic endovascular aneurysm repair (TEVAR) under general anaesthesia (GA). An incidental abdominal aortic aneurysm (AAA) was not treated. Eight months later, he presented with ruptured AAA. Due to the patient's compromised respiratory system, he underwent endovascular aneurysm repair (EVAR) under local anaesthesia (LA). He had a smoother post-operation recovery compared to the first repair under GA.
This is our initial report on the first 4 cases of infra-renal abdominal aortic aneurysms undergoing Endovascular Aneurysm Repair (EVAR) with local anaesthesia, controlled sedation and monitoring by an anaesthetist. All 4 patients were males with a mean age of 66.7 years. Only one (1) required ICU stay of 2 days for cardiac monitoring due to bradycardia and transient hypotension post procedure. No mortality or major post operative morbidity was recorded and the mean hospital stay post procedure was 3.5 days (range 2-5 days).
This is our initial report on the first 4 cases of infra-renal abdominal aortic aneurysm undergoing Endovascular Aneurysm Repair (EVAR) with local anaesthesia, controlled sedation and monitoring by an anaesthetist. All four patients were males with a mean age of 66.7 years. Only one required ICU stay of two days for cardiac monitoring due to bradycardia and transient hypotension post procedure. No mortality or major post operative morbidity was recorded and the mean hospital stay post procedure was 3.5 days (range 2-5 days).
The incidence of infection following TEVAR is low. To the best of our knowledge, this is the first case report of post thoracic endovascular aortic repair (TEVAR) with Streptococcus viridans graft infection. A 54-year-old male underwent TEVAR for dissecting thoracic aneurysm with spinal ischaemia. He had an eventful recovery with prolonged period of stay in intensive care unit. Three months later, he presented with persistent chest discomfort and fever. Computed tomography (CT) of the thorax revealed evidence of graft infection and the blood culture grew Streptococcus viridans. The rarity of TEVAR graft infection due to Streptococcus viridans and its management are being discussed.
Contemporary experience with mitral valve (MV) repair in the rheumatic population is limited. We aimed to examine the long-term outcomes of rheumatic MV repair, to identify the predictors of durability and to compare the repair for rheumatic and degenerative MVs.
Osteo-odontokeratoprosthesis (OOKP) surgery is a technique used to replace damaged cornea in blind patients for whom cadaveric transplantation is not feasible. OOKP surgery is a complex procedure requiring lifetime follow-up. The preservation of the osteo-odontolamina is the vital feature in maintaining the stability of the OOKP. Early detection of lamina resorption enables early prophylactic measures to be taken and prevent resorption-related complications. This case illustrates the radiological findings of the first OOKP surgery in Malaysia and the role of multidetector computed tomography (MDCT) in postoperative management of OOKP surgery.
Patients who lost their eyes as results of accidents or diseases (e.g. retinoblastoma) usually underwent enucleation or evisceration. They were then fi tted with ocular prosthesis to prevent collapse of the globe and also for cosmetic effects. Custom made ocular prosthesis is almost unheard of in this country for most hospitals supply ready-made (stock) prosthesis. The cosmetic results of stock prosthesis are often unsatisfactory. Besides being uncomfortable, stock prosthesis may also induce allergic reaction that may lead to papillary conjunctivitis. The Optometry Clinic at UKM started its custom made prosthetic service in 2010. We described here two cases of patients who complained of discomfort with their old stock prosthesis and re-fitted with custom made prosthesis. We also highlight the importance of proper hygiene and maintenance so that ocular prosthesis can be used for as long as possible. This article aims to create awareness among eye care practitioners and showcase the cosmetic benefi ts of custom made ocular prosthesis.
Study site: Optometry clinic, Universiti Kebangsaan Malaysia, Kuala Lumpur, Malaysia
Today a number of prosthetic suspension systems are available for transtibial amputees. Consideration of an appropriate suspension system can ensure that amputee's functional needs are satisfied. The higher the insight to suspension systems, the easier would be the selection for prosthetists. This review attempted to find scientific evidence pertaining to various transtibial suspension systems to provide selection criteria for clinicians.
Mid-facial defect is one of the most disfiguring and impairing defects. A design of prosthesis that is aesthetic and stable can be precious to a patient who has lost part of his face due to surgical excision. Prosthesis can restore the patients' self-esteem and confidence, which affects the patients and their life style. The aim of this case report is to describe a technique of mid-facial silicone prosthesis fabrication.
Biodegradable metals such as magnesium, iron and their alloys have been known as potential materials for temporary medical implants. However, most of the studies on biodegradable metals have been focusing on optimizing their mechanical properties and degradation behavior with no emphasis on improving their bioactivity behavior. We therefore investigated the possibility of improving iron biodegradation rate and bioactivity by incorporating various bioactive bioceramics. The iron-based bioceramic (hydroxyapatite, tricalcium phosphate and biphasic calcium phosphate) composites were prepared by mechanical mixing and sintering process. Degradation studies indicated that the addition of bioceramics lowered the corrosion potential of the composites and slightly increased their corrosion rate compared to that of pure iron. In vitro cytotoxicity results showed an increase of cellular activity when rat smooth muscle cells interacted with the degrading composites compared to pure iron. X-ray radiogram analysis showed a consistent degradation progress with that found in vivo and positive tissue response up to 70 days implantation in sheep animal model. Therefore, the iron-based bioceramic composites have the potential to be used for biodegradable bone implant applications.
One of the considerable challenges for screw-retained multi-unit implant prosthesis is achieving a passive fit of the prosthesis' superstructure to the implants. This passive fit is supposed to be one of the most vital requirements for the maintenance of the osseointegration. On the other hand, the misfit of the implant supported superstructure may lead to unfavourable complications, which can be mechanical or biological in nature. The manifestations of these complications may range from fracture of various components in the implant system, pain, marginal bone loss, and even loss of osseointegration. Thus, minimizing the misfit and optimizing the passive fit should be a prerequisite for implant survival and success. The purpose of this article is to present and summarize some aspects of the passive fit achieving and improving methods. The literature review was performed through Science Direct, Pubmed, and Google database. They were searched in English using the following combinations of keywords: passive fit, implant misfit and framework misfit. Articles were selected on the basis of whether they had sufficient information related to framework misfit's related factors, passive fit and its achievement techniques, marginal bone changes relation with the misfit, implant impression techniques and splinting concept. The related references were selected in order to emphasize the importance of the passive fit achievement and the misfit minimizing. Despite the fact that the literature presents considerable information regarding the framework's misfit, there was not consistency in literature on a specified number or even a range to be the acceptable level of misfit. On the other hand, a review of the literature revealed that the complete passive fit still remains a tricky goal to be achieved by the prosthodontist.