Displaying publications 21 - 40 of 1043 in total

Abstract:
Sort:
  1. Liu W, Wang YT, Tian DS, Yin ZC, Kwang J
    Dis Aquat Organ, 2002 Apr 24;49(1):11-8.
    PMID: 12093036
    The vp28 gene encoding an envelope protein (28 kDa) of white spot syndrome virus (WSSV) was amplified from WSSV-infected tiger shrimp that originated from Malaysia. Recombinant VP28 protein (r-28) was expressed in Escherichia coli and used as an antigen for preparation of monoclonal antibodies (MAbs). Three murine MAbs (6F6, 6H4 and 9C10) that were screened by r-28 antigen-based enzyme-linked immunosorbent assay (ELISA) were also able to recognize viral VP28 protein as well as r-28 on Western blot. Three non-overlapping epitopes of VP28 protein were determined using the MAbs in competitive ELISA; thus, an antigen-capture ELISA (Ac-ELISA) was developed by virtue of these MAbs. Ac-ELISA can differentiate WSSV-infected shrimp from uninfected shrimp and was further confirmed by a polymerase chain reaction (PCR) and Western blot. Approximately 400 pg of purified WSSV sample and 20 pg of r-28 could be detected by Ac-ELISA, which is comparable in sensitivity to PCR assay but more sensitive than Western blot in the detection of purified virus. Hemolymph and tissue homogenate samples collected from a shrimp farm in Malaysia during December 2000 and July 2001 were also detected by Ac-ELISA and PCR with corroborating results.
    Matched MeSH terms: Sensitivity and Specificity
  2. Newsome PN, Sasso M, Deeks JJ, Paredes A, Boursier J, Chan WK, et al.
    Lancet Gastroenterol Hepatol, 2020 04;5(4):362-373.
    PMID: 32027858 DOI: 10.1016/S2468-1253(19)30383-8
    BACKGROUND: The burden of non-alcoholic fatty liver disease (NAFLD) is increasing globally, and a major priority is to identify patients with non-alcoholic steatohepatitis (NASH) who are at greater risk of progression to cirrhosis, and who will be candidates for clinical trials and emerging new pharmacotherapies. We aimed to develop a score to identify patients with NASH, elevated NAFLD activity score (NAS≥4), and advanced fibrosis (stage 2 or higher [F≥2]).

    METHODS: This prospective study included a derivation cohort before validation in multiple international cohorts. The derivation cohort was a cross-sectional, multicentre study of patients aged 18 years or older, scheduled to have a liver biopsy for suspicion of NAFLD at seven tertiary care liver centres in England. This was a prespecified secondary outcome of a study for which the primary endpoints have already been reported. Liver stiffness measurement (LSM) by vibration-controlled transient elastography and controlled attenuation parameter (CAP) measured by FibroScan device were combined with aspartate aminotransferase (AST), alanine aminotransferase (ALT), or AST:ALT ratio. To identify those patients with NASH, an elevated NAS, and significant fibrosis, the best fitting multivariable logistic regression model was identified and internally validated using boot-strapping. Score calibration and discrimination performance were determined in both the derivation dataset in England, and seven independent international (France, USA, China, Malaysia, Turkey) histologically confirmed cohorts of patients with NAFLD (external validation cohorts). This study is registered with ClinicalTrials.gov, number NCT01985009.

    FINDINGS: Between March 20, 2014, and Jan 17, 2017, 350 patients with suspected NAFLD attending liver clinics in England were prospectively enrolled in the derivation cohort. The most predictive model combined LSM, CAP, and AST, and was designated FAST (FibroScan-AST). Performance was satisfactory in the derivation dataset (C-statistic 0·80, 95% CI 0·76-0·85) and was well calibrated. In external validation cohorts, calibration of the score was satisfactory and discrimination was good across the full range of validation cohorts (C-statistic range 0·74-0·95, 0·85; 95% CI 0·83-0·87 in the pooled external validation patients' cohort; n=1026). Cutoff was 0·35 for sensitivity of 0·90 or greater and 0·67 for specificity of 0·90 or greater in the derivation cohort, leading to a positive predictive value (PPV) of 0·83 (84/101) and a negative predictive value (NPV) of 0·85 (93/110). In the external validation cohorts, PPV ranged from 0·33 to 0·81 and NPV from 0·73 to 1·0.

    INTERPRETATION: The FAST score provides an efficient way to non-invasively identify patients at risk of progressive NASH for clinical trials or treatments when they become available, and thereby reduce unnecessary liver biopsy in patients unlikely to have significant disease.

    FUNDING: Echosens and UK National Institute for Health Research.

    Matched MeSH terms: Sensitivity and Specificity
  3. Peh SC, Kim LH, Poppema S
    Pathology, 2002 Oct;34(5):446-50.
    PMID: 12408344
    AIMS: Epstein-Barr virus (EBV) is associated with many human malignancies. It is implicated in a pathogenetic role in some of these tumours. Two subtypes, type A and B have been identified on the basis of DNA sequence divergence in the nuclear protein genes (EBNA) 2, 3, 4 and 6. They differ in their transforming efficiency and prevalence pattern in different geographical locations. We aimed to identify the virus subtype infection pattern in our EBV-associated diseases.

    METHODS: Paraffin-embedded tissue from 38 lymphomas (17 Hodgkin's, 14 Burkitt's, four T cell and 3 B cell non-Hodgkin's lymphomas) and 14 nasopharyngeal carcinomas (NPC) were studied, with 12 reactive lymph nodes and tonsils as normal control. EBER in situ hybridisation was performed to confirm EBV association in the tumour cells. A nested polymerase chain reaction (PCR) protocol was employed using two pairs of consensus primers which flanked a 105-bp deletion in the type A virus. U2 region encoding for EBNA-2 was chosen as the target of amplification, with cell lines B95.8 and AG876 serving as positive controls for types A and B virus, respectively.

    RESULTS: All cases showed presence of type A virus, consistently detected with nested PCR protocol but not with single step PCR. There was no type B virus or mix infections detected.

    CONCLUSIONS: Nested PCR technique has successfully increased the sensitivity of EBV subtype detection, and type A virus is the prevalent strain associated with human diseases in Malaysia.

    Matched MeSH terms: Sensitivity and Specificity
  4. Wong KK, Ch'ng ES, Loo SK, Husin A, Muruzabal MA, Møller MB, et al.
    Exp Mol Pathol, 2015 Dec;99(3):537-45.
    PMID: 26341140 DOI: 10.1016/j.yexmp.2015.08.019
    Huntingtin-interacting protein 1-related (HIP1R) is an endocytic protein involved in receptor trafficking, including regulating cell surface expression of receptor tyrosine kinases. We have previously shown that low HIP1R protein expression was associated with poorer survival in diffuse large B-cell lymphoma (DLBCL) patients from Denmark treated with R-CHOP (rituximab, cyclophosphamide, doxorubicin, vincristine, prednisone). In this multicenter study, we extend these findings and validate the prognostic and subtyping utility of HIP1R expression at both transcript and protein level. Using data mining on three independent transcriptomic datasets of DLBCL, HIP1R transcript was preferentially expressed in germinal center B-cell (GCB)-like DLBCL subtype (P<0.01 in all three datasets), and lower expression was correlated with worse overall survival (OS; P<0.01) and progression-free survival (PFS; P<0.05) in a microarray-profiled DLBCL dataset. At the protein level examined by immunohistochemistry, HIP1R expression at 30% cut-off was associated with GCB-DLBCL molecular subtype (P=0.0004; n=42), and predictive of OS (P=0.0006) and PFS (P=0.0230) in de novo DLBCL patients treated with R-CHOP (n=73). Cases with high FOXP1 and low HIP1R expression frequency (FOXP1(hi)/HIP1R(lo) phenotype) exhibited poorer OS (P=0.0038) and PFS (P=0.0134). Multivariate analysis showed that HIP1R<30% or FOXP1(hi)/HIP1R(lo) subgroup of patients exhibited inferior OS and PFS (P<0.05) independently of the International Prognostic Index. We conclude that HIP1R expression is strongly indicative of survival when utilized on its own or in combination with FOXP1, and the molecule is potentially applicable for subtyping of DLBCL cases.
    Matched MeSH terms: Sensitivity and Specificity
  5. Al-Marzooq F, Imad MA, How SH, Kuan YC
    Trop Biomed, 2011 Dec;28(3):545-56.
    PMID: 22433883 MyJurnal
    Establishing a microbial diagnosis for patients with community-acquired pneumonia (CAP) is still challenging and is often achieved in only 30-50% of cases. Polymerase chain reaction (PCR) has been shown to be more sensitive than conventional microbiological methods and it could help to increase the microbial yield for CAP patients. This study was designed to develop, optimize and evaluate multiplex real-time PCR as a method for rapid differential detection of five bacterial causes of CAP namely Streptococcus pneumoniae, Burkholderia pseudomallei and atypical bacterial pathogens, Mycoplasma pneumoniae, Chlamydophila pneumoniae and Legionella pneumophila. Duplex and triplex real-time PCR assays were developed using five sets of primers and probes that were designed based on an appropriate specific gene for each of the above CAP pathogens. The performance of primers for each organism was tested using SYBR Green melt curve analysis following monoplex realtime PCR amplification. Monoplex real-time PCR assays were also used to optimize each primers-probe set before combining them in multiplex assays. Two multiplex real-time PCR assays were then optimized; duplex assay for the differential detection of S. pneumoniae and B. pseudomallei, and triplex assay for the atypical bacterial pathogens. Both duplex and triplex real-time PCR assays were tested for specificity by using DNA extracted from 26 related microorganisms and sensitivity by running serial dilutions of positive control DNAs. The developed multiplex real-time PCR assays shall be used later for directly identifying CAP causative agents in clinical samples.
    Matched MeSH terms: Sensitivity and Specificity
  6. Thiruvengadam G, Init I, Fong MY, Lau YL
    Trop Biomed, 2011 Dec;28(3):506-13.
    PMID: 22433878 MyJurnal
    Surface antigens are the most abundant proteins found on the surface of the parasite Toxoplasma gondii. Surface antigen 1 (SAG1) and Surface antigen 2 (SAG2) remain the most important and extensively studied surface proteins. These antigens have been identified to play a role in host cell invasion, immune modulation, virulence attenuation. Recombinant SAG1/2 was cloned and expressed in yeast Pichia pastoris. We describe here optimization of critical parameters involved in high yield expression of the recombinant SAG1/2. Our results suggest that recombinant SAG1/2 were best expressed at 30ºC, pH 6 and 1% methanol as the carbon source by X33 Pichia cells. Additional optimizations included the downstream process such as ammonium sulphate precipitation and dialysis. The fusion protein was purified using Ni-NTA purification system with 80% recovery. The purified protein was 100% specific and sensitive in detection of toxoplasmosis.
    Matched MeSH terms: Sensitivity and Specificity
  7. Ramli NM, Sidek S, Rahman FA, Peyman M, Zahari M, Rahmat K, et al.
    Graefes Arch Clin Exp Ophthalmol, 2014 Jun;252(6):995-1000.
    PMID: 24770532 DOI: 10.1007/s00417-014-2622-6
    PURPOSE: To measure optic nerve (ON) volume using 3 T magnetic resonance imaging (MRI), to correlate ON volume with retinal nerve fiber layer (RNFL) thickness, and to determine the viability of MRI as an objective tool in distinguishing glaucoma severity.

    METHODS: In this cross-sectional study, 30 severe glaucoma patients, 30 mild glaucoma patients and 30 age-matched controls were recruited. All subjects underwent standard automated perimetry, RNFL analysis and 3 T MRI examinations. Glaucoma patients were classified according to the Hodapp-Anderson-Parish classification. Pearson's correlation coefficient was used to correlate ON volume with RNFL, and receiver operating curve (ROC) analysis was performed to determine the sensitivity and specificity of ON volume in detecting glaucoma severity.

    RESULTS: Optic nerve volume was significantly lower in both the left and right eyes of the severe glaucoma group (168.70 ± 46.28 mm(3); 167.40 ± 45.36 mm(3)) than in the mild glaucoma group (264.03 ± 78.53 mm(3); 264.76 ± 78.88 mm(3)) and the control group (297.80 ± 71.45 mm(3); 296.56 ± 71.02 mm(3)). Moderate correlation was observed between: RNFL thickness and ON volume (r = 0.51, p <0.001), and in mean deviation of visual field and optic nerve volume (r = 0.60, p 

    Matched MeSH terms: Sensitivity and Specificity
  8. Leecyous B, Bakhtiar F, Tang MM, Yadzir ZHM, Abdullah N
    Allergol Immunopathol (Madr), 2020 06 09;48(6):626-632.
    PMID: 32532468 DOI: 10.1016/j.aller.2020.01.006
    INTRODUCTION: Basophil activation test (BAT) and immunoassays are the most widely used in vitro tests to diagnose IgE-mediated allergic reactions to penicillin. However, studies to determine if one test is interdependent from another are limited.

    OBJECTIVE: The present study aimed to measure the agreement between BAT and immunoassay in diagnosis of penicillin allergy.

    METHOD: BAT was performed using penicillin G (Pen G), penicillin V (Pen V), penicilloyl-polylysine (PPL), minor determinant mix (MDM), amoxicillin (Amx) and ampicillin (Amp) in 25 patients. Immunoassay of total IgE (tIgE) and specific IgE (sIgE) antibodies to Pen G, Pen V, Amx and Amp were quantified. Skin prick test (SPT) using PPL-MDM, Amx, Amp and Clavulanic acid were also performed.

    RESULTS: Minimal agreement was observed between BAT and immunoassay (k=0.25). Of two BAT-positive patients, one patient is positive to Amx (59.27%, SI=59) and Amp (82.32%, SI=82) but sIgE-negative to all drug tested. This patient is also SPT-positive to both drugs. Another patient is BAT-positive to Pen G (10.18%, SI=40), Pen V (25.07%, SI=100) and Amp (19.52%, SI=79). In sIgE immunoassay, four patients were sIgE-positive to at least one of the drugs tested. The sIgE level of three patients was between low and moderate and they were BAT-negative. One BAT-positive patient had a high level of sIgE antibodies (3.50-17.5kU/L) along with relatively high specific to total IgE ratio ≥0.002 (0.004-0.007).

    CONCLUSIONS: The agreement between BAT and immunoassay is minimal. Performing both tests provides little increase in the sensitivity of allergy diagnosis work-up for immediate reactions to penicillin.

    Matched MeSH terms: Sensitivity and Specificity
  9. Nordin N, Yusof NA, Abdullah J, Radu S, Hushiarian R
    Biosens Bioelectron, 2016 Dec 15;86:398-405.
    PMID: 27414245 DOI: 10.1016/j.bios.2016.06.077
    A simple but promising electrochemical DNA nanosensor was designed, constructed and applied to differentiate a few food-borne pathogens. The DNA probe was initially designed to have a complementary region in Vibrio parahaemolyticus (VP) genome and to make different hybridization patterns with other selected pathogens. The sensor was based on a screen printed carbon electrode (SPCE) modified with polylactide-stabilized gold nanoparticles (PLA-AuNPs) and methylene blue (MB) was employed as the redox indicator binding better to single-stranded DNA. The immobilization and hybridization events were assessed using differential pulse voltammetry (DPV). The fabricated biosensor was able to specifically distinguish complementary, non-complementary and mismatched oligonucleotides. DNA was measured in the range of 2.0×10(-9)-2.0×10(-13)M with a detection limit of 5.3×10(-12)M. The relative standard deviation for 6 replications of DPV measurement of 0.2µM complementary DNA was 4.88%. The fabricated DNA biosensor was considered stable and portable as indicated by a recovery of more than 80% after a storage period of 6 months at 4-45°C. Cross-reactivity studies against various food-borne pathogens showed a reliably sensitive detection of VP.
    Matched MeSH terms: Sensitivity and Specificity
  10. Javaid A, Ahmad N, Afridi AK, Basit A, Khan AH, Ahmad I, et al.
    Am J Trop Med Hyg, 2018 06;98(6):1629-1636.
    PMID: 29611497 DOI: 10.4269/ajtmh.17-0936
    To evaluate the predictive value of time to sputum culture conversion (SCC) in predicting cure and factors associated with time to SCC and cure in multidrug-resistant tuberculosis (MDR-TB) patients, a retrospective study was conducted at programmatic management unit of drug resistant tuberculosis (TB), Peshawar. A total of 428 pulmonary MDR-TB patients enrolled at the study site from January 1, 2012 to August 31, 2014 were followed until treatment outcome was recorded. Survival analysis using Cox proportional hazards model and multivariate binary logistic regression were, respectively, used to identify factors associated with time to SCC and cure. A P value < 0.05 was considered statistically significant. Overall, 90.9% patients achieved SCC, and 76.9% were cured. Previous use of second-line drugs (SLDs) (hazard ratio [HR] = 0.637; 95% confidence interval [CI] = 0.429-0.947), ofloxacin resistance (HR = 0.656; 95% CI = 0.522-0.825) and lung cavitation (HR = 0.744; 95% CI = 0.595-0.931) were significantly associated with time to SCC. In predicting cure, sensitivities of SCC at 2, 4, and 6 months were 64.1% (95% CI = 58.69-69.32), 93.0% (95% CI = 89.69-95.52), and 97.6% (95% CI = 95.27-98.94), respectively, whereas specificities were 67.7% (95% CI = 57.53-76.73), 51.5% (95% CI = 41.25-61.68), and 44.4% (95% CI = 34.45-54.78), respectively. Furthermore, patients' age of 41-60 (odds ratio [OR] = 0.202; 95% CI = 0.067-0.605) and > 60 years (OR = 0.051; 95% CI = 0.011-0.224), body weight > 40 kg (OR = 2.950; 95% CI = 1.462-5.952), previous SLD use (OR = 0.277; 95% CI = 0.097-0.789), lung cavitation (OR = 0.196; 95% CI = 0.103-0.371) and ofloxacin resistance (OR = 0.386; 95% CI = 0.198-0.749) were significantly associated with cure. Association of SCC with cure was substantially stronger at 6 months (OR = 32.10; 95% CI = 14.34-71.85) than at 4 months (OR = 14.13; 95% CI = 7.92-25.21). However in predicting treatment outcomes, the combined sensitivity and specificity of SCC at 4 months was comparable to SCC at 6 months. Patients with risk factors for delayed SCC were also at high risk of unsuccessful outcomes.
    Matched MeSH terms: Sensitivity and Specificity
  11. Tay TKY, Lim KL, Hilmy MH, Thike AA, Goh ST, Song LH, et al.
    Malays J Pathol, 2017 Dec;39(3):257-265.
    PMID: 29279588
    INTRODUCTION: Human papillomavirus (HPV) testing is used as a means of triaging cervico-vaginal smears with low grade squamous abnormalities or as part of co-testing with cytology. While HPV testing has a high sensitivity, it has a low specificity in detecting cervical intraepithelial neoplasia grade 2 and above (CIN 2+) leading to unnecessary colposcopy referrals. We investigate the accuracy of the p16/Ki-67 dual immunocytochemical stain in determining the presence of CIN 2+ lesions on histology and its potential as a superior biomarker for triage.

    METHODS: Liquid based cervico-vaginal cytology specimens with squamous abnormalities and corresponding histology from 97 women with subsequent colposcopy and biopsy were included. The specimens were then subjected to the dual stain and Roche Cobas 4800 multiplex real time PCR HPV DNA testing. The sensitivity and specificity of the dual stain and HPV testing were calculated using CIN 2+ on histology as a reference standard.

    RESULTS: The sensitivity and specificity of the dual stain in detecting histology proven CIN 2+ was 93.7% and 76.5% while HPV testing was 85.7% and 14.7% respectively. Of the 44 women with ASCUS or LSIL on cytology, the dual stain also reduced the number of unnecessary colposcopy referrals from 27 to 7 when used as a triage marker compared to HPV testing.

    CONCLUSION: p16/Ki-67 dual stain was more sensitive and specific than HPV testing in determining the presence of CIN 2+ on histology. It could triage low grade cervico-vaginal specimens more effectively and potentially help women avoid unnecessary colposcopies. Future studies are needed to further evaluate its role in cervical cancer screening programmes.

    Matched MeSH terms: Sensitivity and Specificity
  12. Low GKK, Gan SC, Zainal N, Naidu KD, Amin-Nordin S, Khoo CS, et al.
    Pathog Glob Health, 2018 09;112(6):334-341.
    PMID: 30246621 DOI: 10.1080/20477724.2018.1516417
    This study aimed to evaluate vascular endothelial growth factor (VEGF) and pentraxin 3 (PTX-3) as predictive and diagnostic markers in differentiating severe dengue from non-severe dengue. The study was conducted in Ampang Health Clinic, Ampang Hospital and Serdang Hospital. The plasma levels of VEGF and PTX-3 were compared between severe dengue and non-severe dengue by ELISA from the day of presentation until discharged. Multiple logistic regression was used to develop predictive and diagnostic models by incorporating other clinical parameters. The receiver operating characteristics (ROC) analysis was used to assess the accuracy of the biomarkers and the developed models. Eighty-two patients were recruited, 29 with severe dengue and four died. The Area Under the Curve (AUC) was statistically significant in VEGF as diagnostic marker at Day 2 and 3 of illness with sensitivity of 80.00%-100.00% and specificity of 76.47%-80.00%. The predictive model with AUC of 0.84 (p 
    Matched MeSH terms: Sensitivity and Specificity
  13. Munkongdee T, Tongsima S, Ngamphiw C, Wangkumhang P, Peerapittayamongkol C, Hashim HB, et al.
    Sci Rep, 2021 05 14;11(1):10352.
    PMID: 33990643 DOI: 10.1038/s41598-021-89641-2
    β-Thalassemia/HbE disease has a wide spectrum of clinical phenotypes ranging from asymptomatic to dependent on regular blood transfusions. Ability to predict disease severity is helpful for clinical management and treatment decision making. A thalassemia severity score has been developed from Mediterranean β-thalassemia patients. However, different ethnic groups may have different allele frequency and linkage disequilibrium structures. Here, Thai β0-thalassemia/HbE disease genome-wild association studies (GWAS) data of 487 patients were analyzed by SNP interaction prioritization algorithm, interacting Loci (iLoci), to find predictive SNPs for disease severity. Three SNPs from two SNP interaction pairs associated with disease severity were identifies. The three-SNP disease severity risk score composed of rs766432 in BCL11A, rs9399137 in HBS1L-MYB and rs72872548 in HBE1 showed more than 85% specificity and 75% accuracy. The three-SNP predictive score was then validated in two independent cohorts of Thai and Malaysian β0-thalassemia/HbE patients with comparable specificity and accuracy. The SNP risk score could be used for prediction of clinical severity for Southeast Asia β0-thalassemia/HbE population.
    Matched MeSH terms: Sensitivity and Specificity
  14. Lee CE, Sri Ponnampalavanar S, Syed Omar SF, Mahadeva S, Ong LY, Kamarulzaman A
    Ann Acad Med Singap, 2011 Oct;40(10):448-53.
    PMID: 22206053 DOI: 10.47102/annals-acadmedsg.V40N10p448
    INTRODUCTION: Dried blood spot (DBS) collection is an appealing alternative to whole blood or plasma sampling, as it has technical and economic advantages over the latter.

    MATERIALS AND METHODS: A prospective cross-sectional study was conducted at a Malaysian tertiary referral hospital from November 2009 to March 2010. One hundred and fifty paired specimens of DBS and plasma were analysed by the standard assays for HIV Ag/Ab, HBsAg, anti-HBS and anti-HCV, separately (total 600 paired specimens). DBS sample titres were then compared to the results of plasma testing, which was used as the gold standard.

    RESULTS: For the HIV Ag/Ab assay with a cut-off point of 0.35 Relative Light Units (RLUs), the sensitivity and specificity were both 100%. For the HBsAg assay, the sensitivity was 96.5% and the specificity was 97.8%, with a cut-off point of 1.72 RLUs. Sensitivity for the anti-HBs test was 74.2% and the specificity was 86.9%, using a cut-off point of 0.635 RLUs. For the anti-HCV assay, the sensitivity was 97.3% and the specificity was 100%, with a cut-off point of 0.10 RLUs.

    CONCLUSION: DBS is an ideal choice to be used as a screening tool for the detection of HIV, Hepatitis B and Hepatitis C virus infections. However, different cut-off values need to be used for the validation of test positivity in DBS samples because the small amount of blood in the DBS specimens leads to lower assay titres.
    Matched MeSH terms: Sensitivity and Specificity
  15. Darwish NT, Sekaran SD, Alias Y, Khor SM
    J Pharm Biomed Anal, 2018 Feb 05;149:591-602.
    PMID: 29197806 DOI: 10.1016/j.jpba.2017.11.064
    The sharp increase in incidence of dengue infection has necessitated the development of methods for the rapid diagnosis of this deadly disease. Here we report the design and development of a reliable, sensitive, and specific optical immunosensor for the detection of the dengue nonstructural protein 1 (NS1) biomarker in clinical samples obtained during early stages of infection. The present optical NS1 immunosensor comprises a biosensing surface consisting of specific monoclonal NS1 antibody for immunofluorescence-based NS1 antigen determination using fluorescein isothiocyanate (FITC) conjugated to IgG antibody. The linear range of the optical immunosensor was from 15-500ngmL-1, with coefficient of determination (R2) of 0.92, high reproducibility (the relative standard deviation obtained was 2%), good stability for 21days at 4°C, and low detection limit (LOD) at 15ngmL-1. Furthermore, the optical immunosensor was capable of detecting NS1 analytes in plasma specimens from patients infected with the dengue virus, with low cross-reaction with plasma specimens containing the Japanese encephalitis virus (JEV) and Zika virus. No studies have been performed on the reproducibility and cross-reactivity regarding NS1 specificity, which is thus a limitation for optical NS1 immunosensors. In contrast, the present study addressed these limitations carefully where these two important experiments were conducted to showcase the robustness of our newly developed optical-based fluorescence immunosensor, which can be practically used for direct NS1 determination in any untreated clinical sample.
    Matched MeSH terms: Sensitivity and Specificity
  16. Fadilah N, Hanafiah A, Razlan H, Wong ZQ, Mohamed Rose I, Rahman MM
    Br J Biomed Sci, 2016 Oct;73(4):180-187.
    PMID: 27922429
    BACKGROUND: No gold standard has yet been established for the diagnosis of H. pylori infection. A multiplex polymerase chain reaction (mPCR) was developed in this study for rapid, sensitive and specific detection of H. pylori from gastric biopsies.

    METHODS: H. pylori infections were determined by in-house rapid urease test (iRUT), culture, histology and multiplex PCR.

    RESULTS: A total of 140 (60.9%) from 230 patients were positive for H. pylori infection. H. pylori were detected in 9.6% (22/230), 17% (39/230), 12.6% (29/230) and 60% (138/230) of biopsy specimens by culture, iRUT, histology and mPCR, respectively. mPCR identified H. pylori infection in 100% of biopsies with positive histology and culture. All biopsies with positive iRUT yielded positive PCR except two cases. mPCR also detected H. pylori in additional 116, 101 and 109 biopsies that were negative by culture, iRUT and histology, respectively. Positive samples by mPCR showed lower average in H. pylori density, activity and inflammation scores. The Indians showed the highest prevalence of H. pylori infection compared to the Chinese and the Malays. In addition, Chinese patients with older age were significantly infected compared to other ethnicities.

    CONCLUSION: PCR was able to detect the highest numbers of positive cases although the lowest average scores were recorded in the activity, inflammatory and H. pylori density.

    Matched MeSH terms: Sensitivity and Specificity
  17. Tai YC, Peh SC
    Singapore Med J, 2003 May;44(5):250-5.
    PMID: 13677361
    T- and B-lymphocytes are involved in recognition of foreign antigen by the specificity of their surface T-cell receptor and immunoglobulin, generated by gene rearrangement. Each T- and B-lymphocyte carries unique rearranged TCR or immunoglobulin gene, which has been applied to detect clonal from non-clonal T- and B-cell proliferation.
    Matched MeSH terms: Sensitivity and Specificity
  18. Sekhar WY, Soo EH, Gopalakrishnan V, Devi S
    Singapore Med J, 2000 Aug;41(8):370-5.
    PMID: 11256343
    The aim of the study was to look into the epidemiology of serodiagnosed cases of leptospirosis at the University Hospital and compare two commercial ELISA Assays to the Microscopic Agglutination Test (MAT). Demographic data for all serodiagnosed cases for the years 1991-1997 were collected. From this data, 104 sera (n = 104) were selected as samples for comparative evaluation of the commercial ELISAs (INDX Dip-S-Ticks and PanBio ELISA) to the MAT test. Thirty two (n = 32) negative control sera were selected from serodiagnosed cases of other differential diagnosis of leptospira infection. The MAT test is a standard test that detects agglutination antibodies to leptospira biflexa, while the INDX Dip-S-Ticks is an ELISA dot test assaying for total anti-leptospira antibodies. The PanBio ELISA is a colorometric assay in test well strips to detect anti-leptospira IgM. The sensitivity, specificity, and efficiency of tests were calculated at a MAT cut-off value of 1:320. Demographic data showed that leptospirosis peaks during March-May and Aug-Nov coinciding with the inter-monsoon period with more men being infected than women and more adults than children. The sensitivity, specificity, and efficiency of test for the INDX Dip-S-Ticks were 83.3%, 93.8% and 87.5% while the values for the PanBio ELISA were 54.2%, 96.9% and 71.3%. The suboptimal PanBio result could be related to the blocking effect of high IgG titres or could be related to the diagnostic MAT cut-off values used in this study. The data hence reflects a pattern of transmission that is related to "wet" occupational risk factors. The commercial assays evaluated, are easier to perform but interpretation of results should be based on level of endemicity. The INDX Dip-S-Ticks allows this flexibility and is a practical alternative to the MAT test.
    Matched MeSH terms: Sensitivity and Specificity
  19. Al-Talib H, Latif B, Mohd-Zain Z
    J Clin Microbiol, 2014 Sep;52(9):3244-9.
    PMID: 24958797 DOI: 10.1128/JCM.00891-14
    Diarrheal diseases cause illness and death among children younger than 10 years in developing countries. Conventional testing for the detection of hemorrhagic bacteria takes 2 to 5 days to yield complete information on the organism and its antibiotic sensitivity pattern. Hence, in the present study, we developed a molecular-based diagnostic assay that identifies common hemorrhagic bacteria in stool samples. A set of specific primers were designed for the detection of Salmonella spp., Shigella spp., enterohemorrhagic Escherichia coli (EHEC), and Campylobacter spp., suitable for use in a one-tube PCR assay. The assay in the present study simultaneously detected five genes, namely, ompC for the Salmonella genus, virA for the Shigella genus, eaeA for EHEC, 16S rRNA for the Campylobacter genus, and hemA for an internal control. Specific primer pairs were successfully designed and simultaneously amplified the targeted genes. Validation with 20 Gram-negative and 17 Gram-positive strains yielded 100% specificity. The limit of detection of the multiplex PCR assay was 1 × 10(3) CFU at the bacterial cell level and 100 pg at the genomic DNA level. Further evaluation of the multiplex PCR with 223 bacterium-spiked stool specimens revealed 100% sensitivity and specificity. We conclude that the developed multiplex PCR assay was rapid, giving results within 4 h, which is essential for the identification of hemorrhagic bacteria, and it might be useful as an additional diagnostic tool whenever time is important in the diagnosis of hemorrhagic bacteria that cause diarrhea. In addition, the presence of an internal control in the multiplex PCR assay is important for excluding false-negative cases.
    Matched MeSH terms: Sensitivity and Specificity
  20. Pham MD, Haile BA, Azwa I, Kamarulzaman A, Raman N, Saeidi A, et al.
    J Clin Microbiol, 2019 04;57(4).
    PMID: 30700508 DOI: 10.1128/JCM.01683-18
    HIV viral load (VL) testing is the recommended method for monitoring the response of people living with HIV and receiving antiretroviral therapy (ART). The availability of standard plasma VL testing in low- and middle-income countries (LMICs), and access to this testing, are limited by the need to use fresh plasma. Good specimen collection methods for HIV VL testing that are applicable to resource-constrained settings are needed. We assessed the diagnostic performance of the filtered dried plasma spot (FDPS), created using the newly developed, instrument-free VLPlasma device, in identifying treatment failure at a VL threshold of 1,000 copies/ml in fresh plasma. Performance was compared with that of the conventional dried blood spot (DBS). Venous blood samples from 201 people living with HIV and attending an infectious disease clinic in Malaysia were collected, and HIV VL was quantified using fresh plasma (the reference standard), FDPS, and DBS specimens. VL testing was done using the Roche Cobas AmpliPrep/Cobas TaqMan v2.0 assay. At a threshold of 1,000 copies/ml, the diagnostic performance of the FDPS was superior (sensitivity, 100% [95% confidence interval {CI}, 89.1 to 100%]; specificity, 100% [95% CI, 97.8 to 100%]) to that of the DBS (sensitivity, 100% [95% CI, 89.4 to 100%]; specificity, 36.8% [95% CI, 29.4 to 44.7%]) (P 
    Matched MeSH terms: Sensitivity and Specificity
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links