Displaying publications 21 - 40 of 184 in total

Abstract:
Sort:
  1. Lam SK, Chua KB, Hooi PS, Rahimah MA, Kumari S, Tharmaratnam M, et al.
    PMID: 11944696
    Many countries neighboring Malaysia have reported human infections by chikungunya virus, a mosquito-borne togavirus belonging to the genus Alphavirus. However, although there is serological evidence of its presence in Malaysia, chikungunya virus has not been known to be associated with clinical illness in the country. An outbreak of chikungunya virus occurred in Klang, Malaysia, between December 1998 and February 1999. The majority of the cases were in adults and the clinical presentation was similar to classical chikungunya infections. Malaysia is heavily dependent on migrant workers from countries where chikungunya is endemic. It is speculated that the virus has been re-introduced into the country through the movement of these workers.
    Matched MeSH terms: Antibodies, Viral/blood
  2. Sil BK, Jamiruddin MR, Haq MA, Khondoker MU, Jahan N, Khandker SS, et al.
    Int J Nanomedicine, 2021;16:4739-4753.
    PMID: 34267520 DOI: 10.2147/IJN.S313140
    BACKGROUND: Serological tests detecting severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) are widely used in seroprevalence studies and evaluating the efficacy of the vaccination program. Some of the widely used serological testing techniques are enzyme-linked immune-sorbent assay (ELISA), chemiluminescence immunoassay (CLIA), and lateral flow immunoassay (LFIA). However, these tests are plagued with low sensitivity or specificity, time-consuming, labor-intensive, and expensive. We developed a serological test implementing flow-through dot-blot assay (FT-DBA) for SARS-CoV-2 specific IgG detection, which provides enhanced sensitivity and specificity while being quick to perform and easy to use.

    METHODS: SARS-CoV-2 antigens were immobilized on nitrocellulose membrane to capture human IgG, which was then detected with anti-human IgG conjugated gold nanoparticle (hIgG-AuNP). A total of 181 samples were analyzed in-house. Within which 35 were further evaluated in US FDA-approved CLIA Elecsys SARS-CoV-2 assay. The positive panel consisted of RT-qPCR positive samples from patients with both <14 days and >14 days from the onset of clinical symptoms. The negative panel contained samples collected from the pre-pandemic era dengue patients and healthy donors during the pandemic. Moreover, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of FT-DBA were evaluated against RT-qPCR positive sera. However, the overall efficacies were assessed with sera that seroconverted against either nucleocapsid (NCP) or receptor-binding domain (RBD).

    RESULTS: In-house ELISA selected a total of 81 true seropositive and 100 seronegative samples. The sensitivity of samples with <14 days using FT-DBA was 94.7%, increasing to 100% for samples >14 days. The overall detection sensitivity and specificity were 98.8% and 98%, respectively, whereas the overall PPV and NPV were 99.6% and 99%. Moreover, comparative analysis between in-house ELISA assays and FT-DBA revealed clinical agreement of Cohen's Kappa value of 0.944. The FT-DBA showed sensitivity and specificity of 100% when compared with commercial CLIA kits.

    CONCLUSION: The assay can confirm past SARS-CoV-2 infection with high accuracy within 2 minutes compared to commercial CLIA or in-house ELISA. It can help track SARS-CoV-2 disease progression, population screening, and vaccination response. The ease of use of the assay without requiring any instruments while being semi-quantitative provides the avenue of its implementation in remote areas around the globe, where conventional serodiagnosis is not feasible.

    Matched MeSH terms: Antibodies, Viral/blood
  3. Daodu OB, Adebiyi AI, Oluwayelu DO
    Trop Biomed, 2019 Dec 01;36(4):1054-1060.
    PMID: 33597474
    Evidence of influenza A virus (IAV) infection in dogs, a major companion animal of humans, suggests the possibility that they may constitute a new source for transmission of novel influenza viruses to humans. The potential public health risk posed by this possibility of interspecies spread of IAV between dogs and humans necessitated surveillance for the virus in dogs and their human contacts. Sera from 239 asymptomatic pet and hunting dogs in Oyo state, Nigeria were screened for anti-IAV nucleoprotein antibodies using competitive enzyme-linked immunosorbent assay (ELISA) while haemagglutination inhibiting (HI) antibodies in the positive sera were detected using influenza virus H3 and H5 subtypespecific antigens. Suspensions prepared from 239 and 39 nasal swabs from dogs and human contacts, respectively were tested for presence of the highly conserved IAV matrix gene by reverse transcriptase-polymerase chain reaction (RT-PCR). Only 4 (1.7%) of the 239 sera tested were positive by the ELISA. The HI test confirmed the presence of H3 influenza virus subtype-specific antibodies in one (25.0%) of the 4 ELISA-positive sera with a titre of 1:128 while none was positive for H5 subtype-specific antibodies. All the nasal swabs assayed by RT-PCR were negative for IAV nucleic acid. The detection of IAV antibodies in pet and hunting dogs in this study, although at a low rate, suggests that these dogs could play a crucial role in the zoonotic transmission of influenza viruses especially considering the close interaction between them and their human contacts. Continuous surveillance for IAV among dog populations in Oyo State (and Nigeria) is therefore advocated to facilitate early detection of infection or emergence of novel influenza virus strains that could be potentially harmful to humans and or animals.
    Matched MeSH terms: Antibodies, Viral/blood
  4. Chong ZL, Soe HJ, Ismail AA, Mahboob T, Chandramathi S, Sekaran SD
    Biosensors (Basel), 2021 Apr 22;11(5).
    PMID: 33921935 DOI: 10.3390/bios11050129
    Dengue is a major threat to public health globally. While point-of-care diagnosis of acute/recent dengue is available to reduce its mortality, a lack of rapid and accurate testing for the detection of previous dengue remains a hurdle in expanding dengue seroepidemiological surveys to inform its prevention, especially vaccination, to reduce dengue morbidity. This study evaluated ViroTrack Dengue Serostate, a biosensors-based semi-quantitative anti-dengue IgG (immunoglobulin G) immuno-magnetic agglutination assay for the diagnosis of previous and recent dengue in a single test. Blood samples were obtained from 484 healthy participants recruited randomly from two communities in Petaling district, Selangor, Malaysia. The reference tests were Panbio Dengue IgG indirect and capture enzyme-linked immunosorbent assays, in-house hemagglutination inhibition assay, and focus reduction neutralization test. Dengue Serostate had a sensitivity and specificity of 91.1% (95%CI 87.8-93.8) and 91.1% (95%CI 83.8-95.8) for the diagnosis of previous dengue, and 90.2% (95%CI 76.9-97.3) and 93.2% (95%CI 90.5-95.4) for the diagnosis of recent dengue, respectively. Its positive predictive value of 97.5% (95%CI 95.3-98.8) would prevent most dengue-naïve individuals from being vaccinated. ViroTrack Dengue Serostate's good point-of-care diagnostic accuracy can ease the conduct of dengue serosurveys to inform dengue vaccination strategy and facilitate pre-vaccination screening to ensure safety.
    Matched MeSH terms: Antibodies, Viral/blood
  5. Beh CC, Zulkufli NS, Loh LM, Cheng KW, Choo LM, Cheah MW, et al.
    Trop Biomed, 2021 Dec 01;38(4):552-560.
    PMID: 35001921 DOI: 10.47665/tb.38.4.098
    Understanding of antibody kinetics against SARS-CoV-2 and its vaccines is rapidly evolving. This study aims to (1) determine post-vaccination seroprevalence; (2) compare antibody levels between vaccine types and various clinical/demographic determinants; and (3) determine post-vaccination antibody concentrations against time. This is a retrospective cross-sectional study involving 148 healthcare employees all over Malaysia. IgG Spike (RBD), IgM Spike and IgG Nucleocapsid concentration medians were compared using Mann-Whitney U or Kruskal-Wallis tests. Chi Square and Spearman correlation coefficient tests were performed to identify variables associated with antibody titers. A scatter plot of IgG Spike (RBD) against time from last vaccine dose was also plotted. At 1-month post-vaccination, all employees successfully seroconverted regardless of vaccine type, health status and COVID- 19 history. Comirnaty, convalescent, female or Malay vaccinees had significantly higher IgG Spike (RBD) titers compared to their respective counterparts. No correlation was found between age and IgG Spike (RBD) levels. Concentration of all three antibodies waned with time post-vaccination, with IgM Spike and IgG Nucleocapsid waning faster than IgG Spike (RBD).
    Matched MeSH terms: Antibodies, Viral/blood*
  6. Tan LH, Lum LC, Omar SF, Kan FK
    J Clin Virol, 2012 Sep;55(1):79-82.
    PMID: 22789140 DOI: 10.1016/j.jcv.2012.06.005
    Hemophagocytic syndrome is a potentially fatal disorder. It is being increasingly reported but remained under-recognized in dengue. Most reported cases were in association with plasma leakage and shock but multi-organ impairment was also observed. We describe the time-lines of 6 cases of confirmed dengue with varying severities of hemophagocytosis. All had persistent fever, cytopenia and elevated transaminases with markedly elevated ferritin levels during and beyond the plasma leakage phase. Acute renal failure and central nervous system manifestation were observed in two patients. Morphological hemophagocytosis was demonstrated in three patients. All survivors showed clinical and biochemical resolution of hemophagocytosis indicating its transient nature. Persistence of fever and cytopenia together with multi-organ dysfunction, out of proportion to and beyond the plasma leakage phase should prompt clinicians to consider this phenomenon.
    Matched MeSH terms: Antibodies, Viral/blood
  7. Dups J, Middleton D, Long F, Arkinstall R, Marsh GA, Wang LF
    Virol J, 2014;11:102.
    PMID: 24890603 DOI: 10.1186/1743-422X-11-102
    Nipah virus and Hendra virus are closely related and following natural or experimental exposure induce similar clinical disease. In humans, encephalitis is the most serious outcome of infection and, hitherto, research into the pathogenesis of henipavirus encephalitis has been limited by the lack of a suitable model. Recently we reported a wild-type mouse model of Hendra virus (HeV) encephalitis that should facilitate detailed investigations of its neuropathogenesis, including mechanisms of disease recrudescence. In this study we investigated the possibility of developing a similar model of Nipah virus encephalitis.
    Matched MeSH terms: Antibodies, Viral/blood
  8. Kolomytsev AA, Kurinnov VV, Mikolaĭchuk SV, Zakutskiĭ NI
    Vopr. Virusol., 2008 Mar-Apr;53(2):10-3.
    PMID: 18450103
    Nipah encephalitis is a particular dangerous disease that affects animals and man. Fatal cases of the disease have been identified in the persons looking after pigs in the villages of Malaysia. The causative agent is presumably referred to as morbilliviruses of the Paramixoviridae family. Two hundred persons died among the ill patients with the signs of encephalitis. The principal hosts of the virus were fox-bats (Megaschiroptera) inhabiting in the surrounding forests. The present paper descries the epidemiological features of the disease, its clinical manifestations, abnormal anatomic changes, diagnosis, and implemented controlling measures.
    Matched MeSH terms: Antibodies, Viral/blood
  9. Yamamoto K, Matumoto K, Lim CK, Moi ML, Kotaki A, Takasaki T
    Intern. Med., 2010;49(5):501-5.
    PMID: 20190493
    An adult Malaysian woman returned to Japan from Kuala Lumpur and had onset of dengue fever-like symptoms including high fever, malaise and arthritis in early January 2009. Serum obtained on the following day was tested at the National Institute of Infectious Diseases in Tokyo, where it was determined to be positive for chikungunya virus (CHIKV) RNA. IgM antibody against CHIKV was negative on January 6 and sero-converted to be positive on January 14, confirming a recent CHIKV infection. Except for arthralgia, all her symptoms resolved uneventfully within 10 days.
    Matched MeSH terms: Antibodies, Viral/blood
  10. Ahmed SA, Al-Joudi FS, Zaidah AW, Roshan TM, Rapiaah M, Abdullah YM, et al.
    PMID: 17124989
    Human cytomegalovirus (HCMV) is a species-specific DNA virus of the Herpetoviridae family. After a primary infection, HCMV persists in a latent form most probably in bone marrow progenitor cells or in peripheral blood monocytes. The virus can reactivate to result in shedding of the virus leading to virus dissemination and new infections. Immunocompromized patients are the ones most vulnerable to serious diseases occasionally acquired in blood transfusions. In a human population, HCMV seropositivity increases steadily with age to become approximately 100% in adults. This study was performed to detect seropositivity among regular blood donors in The Hospital of the Universiti Sains Malaysia, in the state of Kelantan. Using an enzyme immunoassay, it was found that 97.6% of blood donors were HCMV-positive. HCMV is highly prevalent and may be endemic in Kelantan. Hence, long-term strategies are required for the reduction of disease dissemination, and to prevent the exposure of immunocompromized patients to the virus.
    Matched MeSH terms: Antibodies, Viral/blood*
  11. Cheah WL, Chang MS, Wang YC
    Trop Biomed, 2006 Jun;23(1):85-96.
    PMID: 17041556 MyJurnal
    The objective of this study was to elucidate the association of various risk factors with dengue cases reported in Lundu district, Sarawak, by analyzing the interaction between environmental, entomological, socio-demographic factors. Besides conventional entomological, serological and house surveys, this study also used GIS technology to generate geographic and environmental data on Aedes albopictus and dengue transmission. Seven villages were chosen based on the high number of dengue cases reported. A total of 551 households were surveyed. An overall description of the socio-demographic background and basic facilities was presented together with entomological and geographical profiles. For serological and ovitrap studies, systematic random sampling was used. Serological tests indicated that 23.7% of the 215 samples had a history of dengue, either recent or previous infections. Two samples (0.9%) were confirmed by IgM ELISA and 49 samples (22.8%) had IgG responses. A total of 32,838 Aedes albopictus eggs were collected in 56 days of trapping. Cluster sampling was also done to determine whether any of the risk factors (entomological or geographical) were influenced by geographical location. These clusters were defined as border villages with East Kalimantan and roadside villages along Lundu/Biawas trunk road. The data collected were analyzed using SPSS version 10.01. Descriptive analysis using frequency, means, and median were used. To determine the association between variables and dengue cases reported, and to describe the differences between the two clusters of villages, two-sample t-test, and Pearson's Chi-Square were used. Accurate maps were produced with overlay and density function, which facilitates the map visualization and report generating phases. This study also highlights the use of differential Global Positioning System in mapping sites of 1m accuracy. Analysis of the data revealed there are significant differences in clusters of villages attributable to container density, house density, distance of the house from the main road, and number of Ae. albopictus eggs from ovitraps set indoor, outdoor and in dumping sites (Person's Chi-Square = 6.111, df = 1, p < 0.01). Further analysis using t-test showed that house density, container density, indoor mosquitoes egg count, outdoor mosquitoes egg count, and dumping sites mosquitoes egg count were higher at the roadside villages compared to border villages. A number of potential risk factors including those generated from GIS were investigated. None of the factors investigated in this study were associated with the dengue cases reported.
    Matched MeSH terms: Antibodies, Viral/blood
  12. Hafner C, Koellner K, Vogt T, Landthaler M, Szeimies RM
    Hautarzt, 2006 Aug;57(8):705-7.
    PMID: 16283129
    A 39-year-old patient developed a disseminated rash with scattered petechiae, fever, malaise and arthralgia after a trip to Malaysia. The patient displayed increasing dengue IgG titers and borderline dengue IgM titers. Dengue fever with a hemorrhagic course is a rare condition in adult patients. Patients who have previously had dengue fever and retained non-neutralizing heterotypic antibodies are more likely to develop this complication via the phenomenon of antibody-dependent enhancement.
    Matched MeSH terms: Antibodies, Viral/blood
  13. Sohayati AR, Hassan L, Sharifah SH, Lazarus K, Zaini CM, Epstein JH, et al.
    Epidemiol Infect, 2011 Oct;139(10):1570-9.
    PMID: 21524339 DOI: 10.1017/S0950268811000550
    This study aimed to describe the transmission dynamics, the serological and virus excretion patterns of Nipah virus (NiV) in Pteropus vampyrus bats. Bats in captivity were sampled every 7-21 days over a 1-year period. The data revealed five NiV serological patterns categorized as high and low positives, waning, decreasing and increasing, and negative in these individuals. The findings strongly suggest that NiV circulates in wild bat populations and that antibody could be maintained for long periods. The study also found that pup and juvenile bats from seropositive dams tested seropositive, indicating that maternal antibodies against NiV are transmitted passively, and in this study population may last up to 14 months. NiV was isolated from the urine of one bat, and within a few weeks, two other seronegative bats seroconverted. Based on the temporal cluster of seroconversion, we strongly believe that the NiV isolated was recrudesced and then transmitted horizontally between bats during the study period.
    Matched MeSH terms: Antibodies, Viral/blood*
  14. Kumarasamy V, Zuridah H, Hani AW, Mariam M, Chua KB
    Med J Malaysia, 2007 Mar;62(1):85-6.
    PMID: 17682584 MyJurnal
    The performance of a commercial rapid immunochromatographic dengue IgG/IgM assay device was evaluated against an in-place dengue IgM-capture ELISA in the National Public Health laboratory. Of the 239 serum samples from patients with clinical diagnosis of acute dengue illness, 140 and 99 samples were tested positive and negative respectively for anti-dengue IgM by the in-placed ELISA. Comparatively, 72 and 76 samples were tested positive and negative respectively, and 91 samples gave equivocal results by the rapid dengue test device. The rapid immunochromatographic assay device gave a relative sensitivity of 49.3% and a relative specificity of 62.6%. Though the rapid immunochromatographic assay device has the advantages of rapid testing which simultaneously detects both IgG and IgM and can also be performed with whole blood, serum or plasma, the user has to exercise extreme caution with the interpretation of the test result.
    Matched MeSH terms: Antibodies, Viral/blood
  15. Hunsperger EA, Yoksan S, Buchy P, Nguyen VC, Sekaran SD, Enria DA, et al.
    PLoS Negl Trop Dis, 2014 Oct;8(10):e3171.
    PMID: 25330157 DOI: 10.1371/journal.pntd.0003171
    Commercially available diagnostic test kits for detection of dengue virus (DENV) non-structural protein 1 (NS1) and anti-DENV IgM were evaluated for their sensitivity and specificity and other performance characteristics by a diagnostic laboratory network developed by World Health Organization (WHO), the UNICEF/UNDP/World Bank/WHO Special Programme for Research and Training in Tropical Diseases (TDR) and the Pediatric Dengue Vaccine Initiative (PDVI). Each network laboratory contributed characterized serum specimens for the panels used in the evaluation. Microplate enzyme-linked immunosorbent assay (ELISA) and rapid diagnostic test (RDT formats) were represented by the kits. Each ELISA was evaluated by 2 laboratories and RDTs were evaluated by at least 3 laboratories. The reference tests for IgM anti-DENV were laboratory developed assays produced by the Armed Forces Research Institute for Medical Science (AFRIMS) and the Centers for Disease Control and Prevention (CDC), and the NS1 reference test was reverse transcriptase polymerase chain reaction (RT-PCR). Results were analyzed to determine sensitivity, specificity, inter-laboratory and inter-reader agreement, lot-to-lot variation and ease-of-use. NS1 ELISA sensitivity was 60-75% and specificity 71-80%; NS1 RDT sensitivity was 38-71% and specificity 76-80%; the IgM anti-DENV RDTs sensitivity was 30-96%, with a specificity of 86-92%, and IgM anti-DENV ELISA sensitivity was 96-98% and specificity 78-91%. NS1 tests were generally more sensitive in specimens from the acute phase of dengue and in primary DENV infection, whereas IgM anti-DENV tests were less sensitive in secondary DENV infections. The reproducibility of the NS1 RDTs ranged from 92-99% and the IgM anti-DENV RDTs from 88-94%.
    Matched MeSH terms: Antibodies, Viral/blood*
  16. Thiha A, Ibrahim F
    Sensors (Basel), 2015;15(5):11431-41.
    PMID: 25993517 DOI: 10.3390/s150511431
    The enzyme-linked Immunosorbent Assay (ELISA) is the gold standard clinical diagnostic tool for the detection and quantification of protein biomarkers. However, conventional ELISA tests have drawbacks in their requirement of time, expensive equipment and expertise for operation. Hence, for the purpose of rapid, high throughput screening and point-of-care diagnosis, researchers are miniaturizing sandwich ELISA procedures on Lab-on-a-Chip and Lab-on-Compact Disc (LOCD) platforms. This paper presents a novel integrated device to detect and interpret the ELISA test results on a LOCD platform. The system applies absorption spectrophotometry to measure the absorbance (optical density) of the sample using a monochromatic light source and optical sensor. The device performs automated analysis of the results and presents absorbance values and diagnostic test results via a graphical display or via Bluetooth to a smartphone platform which also acts as controller of the device. The efficacy of the device was evaluated by performing dengue antibody IgG ELISA on 64 hospitalized patients suspected of dengue. The results demonstrate high accuracy of the device, with 95% sensitivity and 100% specificity in detection when compared with gold standard commercial ELISA microplate readers. This sensor platform represents a significant step towards establishing ELISA as a rapid, inexpensive and automatic testing method for the purpose of point-of-care-testing (POCT) in resource-limited settings.
    Matched MeSH terms: Antibodies, Viral/blood
  17. Jahanshahi P, Sekaran SD, Adikan FR
    Med Biol Eng Comput, 2015 Aug;53(8):679-87.
    PMID: 25791696 DOI: 10.1007/s11517-015-1262-2
    Evaluation of binding between analytes and its relevant ligands on surface plasmon resonance (SPR) biosensor is of considerable importance for accurate determination and screening of an interference in immunosensors. Dengue virus serotype 2 was used as a case study in this investigation. This research work compares and interprets the results obtained from analytical analysis with the experimental ones. Both the theoretical calculations and experimental results are verified with one sample from each category of dengue serotypes 2 (low, mid, and high positive), which have been examined in the database of established laboratorial diagnosis. In order to perform this investigation, the SPR angle variations are calculated, analyzed, and then validated via experimental SPR angle variations. Accordingly, the error ratios of 5.35, 6.54, and 3.72% were obtained for the low-, mid-, and high-positive-specific immune globulins of patient serums, respectively. In addition, the magnetic fields of the biosensor are numerically simulated to show the effect of different binding mediums.
    Matched MeSH terms: Antibodies, Viral/blood*
  18. Yoo SJ, Wang LL, Ning HC, Tao CM, Hirankarn N, Kuakarn S, et al.
    J Clin Virol, 2015 Mar;64:20-7.
    PMID: 25728074 DOI: 10.1016/j.jcv.2014.12.015
    Early diagnosis of hepatitis C virus (HCV) infection is essential to allow appropriate treatment and prevent transmission.
    Matched MeSH terms: Antibodies, Viral/blood*
  19. Saraswathy TS, Rozainanee MZ, Asshikin RN, Zainah S
    PMID: 24050074
    Rubella infection in pregnant women during the first trimester of pregnancy can lead to fetal anomalies, commonly known as congenital rubella syndrome (CRS). The objective of our study was to analyze the serological test results among infants suspected of having CRS aged < or = 12 months compared with their clinical status. Between January 2002 and December 2011, 3,279 serum samples from infants aged < or = 12 months from government hospitals in Malaysia were examined for rubella specific IgM and IgG antibodies using a Axsym, automated analyzer (Abbott Laboratories). Forty-eight samples were positive for rubella specific IgM antibodies and 494 samples were positive for rubella specific IgG antibodies. These were then age stratified and their clinical history reviewed for any CRS symptoms. Fifteen of 38 rubella IgM positive infants (39.5%) aged < 3 months, had a clinical appearance compatible with CRS. However, only 1 IgM positive infant aged 3 to 6 months and one infant aged 7 to 11 months had clinical appearance compatible with CRS. The most common abnormal findings in these cases were congenital heart defects and cataracts. Forty-eight point eight percent of IgM positive cases and 53.1% of IgG positive cases, had inadequate information in the chart to determine the presence of CRS. Clinical findings and timely laboratory diagnosis to determine the presence of CRS are important in infants born with congenital defects. Physicians should also be aware of the appropriate interpretation of these findings.
    Matched MeSH terms: Antibodies, Viral/blood*
  20. Kim JD, Lee AR, Moon DH, Chung YU, Hong SY, Cho HJ, et al.
    Emerg Microbes Infect, 2024 Dec;13(1):2343910.
    PMID: 38618740 DOI: 10.1080/22221751.2024.2343910
    Japanese encephalitis (JE), caused by the Japanese encephalitis virus (JEV), is a highly threatening disease with no specific treatment. Fortunately, the development of vaccines has enabled effective defense against JE. However, re-emerging genotype V (GV) JEV poses a challenge as current vaccines are genotype III (GIII)-based and provide suboptimal protection. Given the isolation of GV JEVs from Malaysia, China, and the Republic of Korea, there is a concern about the potential for a broader outbreak. Under the hypothesis that a GV-based vaccine is necessary for effective defense against GV JEV, we developed a pentameric recombinant antigen using cholera toxin B as a scaffold and mucosal adjuvant, which was conjugated with the E protein domain III of GV by genetic fusion. This GV-based vaccine antigen induced a more effective immune response in mice against GV JEV isolates compared to GIII-based antigen and efficiently protected animals from lethal challenges. Furthermore, a bivalent vaccine approach, inoculating simultaneously with GIII- and GV-based antigens, showed protective efficacy against both GIII and GV JEVs. This strategy presents a promising avenue for comprehensive protection in regions facing the threat of diverse JEV genotypes, including both prevalent GIII and GI as well as emerging GV strains.
    Matched MeSH terms: Antibodies, Viral/blood
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links