  1. Tan SL, Rahmat K, Rozalli FI, Mohd-Shah MN, Aziz YF, Yip CH, et al.
    Clin Radiol, 2014 Jan;69(1):63-71.
    PMID: 24156797 DOI: 10.1016/j.crad.2013.08.007
    To investigate the capability and diagnostic accuracy of diffusion-weighted imaging (DWI) in differentiating benign from malignant breast lesions using 3 T magnetic resonance imaging (MRI).
    Matched MeSH terms: Ultrasonography, Mammary
  2. Goh SC, Ho EL, Goh KL
    Hepatol Int, 2013 Jun;7(2):548-54.
    PMID: 26201786 DOI: 10.1007/s12072-012-9359-2
    BACKGROUND: The prevalence of non-alcoholic fatty liver disease (NAFLD) in the Malaysian population is not known. Malaysia has a multiracial Asian population with three major Asian races: Malay, Chinese, and Indian living together. The aim of the study is to determine the prevalence and risk factors in a suburban Malaysian population.

    METHODS: Consecutive subjects who came for a health checkup at a suburban medical facility were recruited for the study. All individuals had clinical assessments, anthropometric measurements, blood tests, and ultrasonography of the liver performed. Those with significant alcohol consumption and history of chronic liver disease were excluded.

    RESULTS: Of the 1,621 "health screened" individuals analyzed, 368 (22.7 %) were found to have NAFLD. They comprised Chinese 1,269 (78.3 %), Malay 197 (12.1 %), and Indian 155 (9.6 %). Males and "older" age group ≥45 years had high prevalence rates with the highest in Indian (68.2 %) and Malay (64.7 %) males. Chinese females <45 years had the lowest prevalence of 5.2 %. A significant increase in the prevalence of fatty liver between age <45 years and ≥45 years was seen in female of all three races but in male, this increase was seen only among the Indians. NAFLD was strongly associated with diabetes mellitus, glucose intolerance, body mass index ≥23, low high-density lipoprotein cholesterol, hypertriglyceridemia, and hypertension.

    CONCLUSION: NAFLD is common in suburban Malaysian population. Older Indian and Malay males have an inordinately high prevalence of the disease.

    Matched MeSH terms: Ultrasonography
  3. Sani FM, Sarji SA, Bilgen M
    J Ultrasound Med, 2011 Jul;30(7):883-94.
    PMID: 21705720
    OBJECTIVES: The purpose of this study was to test the hypothesis that quantitative ultrasound properties of the calcaneus in Southeast Asian children treated for thalassemia have different characteristics than those of their healthy counterparts and thereby can be used for assessing the risk of osteoporosis.

    METHODS: Broadband ultrasound attenuation and the speed of sound were measured from groups of thalassemic and healthy children and compared with bone mineral density (BMD) estimated from dual-energy X-ray absorptiometry to determine intergroup and intragroup dependencies of the measurements and variations with differences in sex and anthropometric characteristics.

    RESULTS: Broadband ultrasound attenuation and speed of sound measurements were found to be independent of sex but dependent on age in the thalassemic children. Consistently, broadband ultrasound attenuation had lower values and the speed of sound had higher values compared with those of the healthy children in each age group. Broadband ultrasound attenuation correlated well with the speed of sound and also with age, weight, and height, but the speed of sound did not show an association with these parameters. Broadband ultrasound attenuation correlated moderately with BMD in the lumbar spine and whole body, but the corresponding association was much weaker for the speed of sound. In the thalassemic children, both broadband ultrasound attenuation and BMD increased with age as they grew older but not fast enough compared with the healthy children, and the risk of osteoporosis was greater at older ages.

    CONCLUSIONS: Calcaneal quantitative ultrasound may be used as a diagnostic screening tool for assessing the bone status in thalassemic Southeast Asian children and for deciding whether further dual-energy X-ray absorptiometry is needed, particularly in those who are at a greater risk for osteoporosis as identified by low body weight and height.

    Matched MeSH terms: Ultrasonography
  4. Mazlan SA, bin Mohamed Said MS, Hussein H, binti Shamsuddin K, Shah SA, Basri H
    Acta Medica (Hradec Kralove), 2009;52(3):107-16.
    PMID: 20073422 DOI: 10.14712/18059694.2016.114
    INTRODUCTION: Psoriatic Arthritis (PsA) is an inflammatory arthritis associated with Psoriasis. Its recognition as an inflammatory disease distinct from Rheumatoid Arthritis has put forward for consideration several questions regarding its specific CVS mortality and morbidity (9, 11, 16, 26). Carotid intima media thickness is a useful surrogate and sensitive marker to determine atherosclerosis even in its subclinical stages (6, 14, 22, 27, 32).

    OBJECTIVE: Prevalence of carotid intima media thickness in patients with Psoriatic arthritis is unknown in Asian population. We aim to identify the presence of subclinical atherosclerosis in patients with psoriatic arthritis and disease activity association and its predictors in a series of patients with PsA attended to the rheumatology clinic, tertiary hospitals.

    METHODS: A total of 63 patients with PsA who fulfilled the CASPAR criteria were recruited from UKM Medical Centre and Hospital Putrajaya. Common carotid intima media thickness (IMT) was measured in both right and left carotid artery by using high resolution B-mode ultrasound. This was a cross sectional study first done in Malaysia for PsA patients.

    RESULTS: The positive IMT (IMT > 1.00 mm) among PsA was observed in 10 out of 63 patients (15.9 %) regardless of background cardiovascular risk. The mean +/- SD of IMT was 0.725 +/-0.260 mm for this study. Variables significantly associated with positive IMT (p < 0.05) included age at the time of study (p = 0.005), waist circumference (p = 0.001), Hypertension (p = 0.007), Diabetes (p = 0.002) and Metabolic syndrome (p = 0.001) and not associated with gender, ethnicity, duration of PsA disease, pattern of PsA, disease activity and severity. Above all, only age had positive IMT independent predictor (p = 0.032), with OR 1.116; 95 % CI (1.010-1.234).

    CONCLUSIONS: There was a significant association between CVS risk and positive Intima Media Thickness in Psoriatic Arthritis patients. Otherwise, there was no association in disease activity, disease severity and DMARDS therapy with positive Intima Media Thickness in Psoriatic Arthritis patients. The study was approved by Research and Ethics Committee of the faculty of medicine, Universiti Kebangsaan Malaysia with project code FF-114-2008 and by Community Research Center (CRC) of National Institutes of Health (NIH) for the case study in Hospital Putrajaya with the project code NMRR-08-970-2125.
    Matched MeSH terms: Ultrasonography
  5. Tan PC, Vallikkannu N, Suguna S, Quek KF, Hassan J
    Clin Exp Obstet Gynecol, 2009;36(1):35-9.
    PMID: 19400416
    OBJECTIVE: To evaluate the predictive value for successful labor induction of transvaginal ultrasound (TVS) of cervical length according to parity.

    METHOD: TVS of the cervix was performed before term labor induction. Induction was considered successful if vaginal delivery was achieved within 24 hours; 231 women were available for final analysis.

    RESULTS: Analysis of the receiver operator characteristics curve showed an optimal cut-off for cervical length of < or = 20 mm for successful induction. Following multivariate logistic regression analysis, a sonographic short cervix (AOR 5.6; p < 0.001) was an independent predictor of successful induction but not a favorable Bishop score (p = 0.47). Among multiparas with a short cervix, positive and negative predictive values for successful induction were 98% (95% CI 90-100%) and 21% (95% CI 13%-32%) and among nulliparas, predictive values were 69% (95% CI 53%-82%) and 77% (95% CI 64%-87%) respectively.

    CONCLUSION: In nulliparas, cervical length can usefully predict labor induction outcome.

    Matched MeSH terms: Ultrasonography
  6. Roethlisberger M, Wuerstlein R, Majores M, Müller-Stöver I, Seitz HM, Rhiem K, et al.
    Breast care (Basel, Switzerland), 2012 Dec;7(6):487-9.
    PMID: 24715832 DOI: 10.1159/000345471
    BACKGROUND: The term filariasis comprises a group of parasitic infections caused by helminths belonging to different genera in the superfamily Filaroidea. The human parasites occur mainly in tropical and subtropical regions, but filariae are also found in temperate climates, where they can infect wild and domestic animals. Humans are rarely infected by these zoonotic parasites.

    PATIENTS AND METHODS: A 55-year-old patient presented with a new-onset, subcutaneous, non-tender palpable mass in the right axilla. Ultrasonography showed a 1.3-cm, solid, singular encapsulated node. Sonography of the breast on both sides, axilla and lymphatic drainage on the left side, lymphatic drainage on the right side, and mammography on both sides were without pathological findings. The node was excised under local anesthesia as the patient refused minimal invasive biopsy.

    RESULTS: On histopathological examination, the tail of a parasite of the group of filariae was found. The patient revealed that she had stayed in Africa and Malaysia for professional reasons. 6 months before the time of diagnosis, she had also suffered from a fever and poor general condition after a trip abroad. The patient was referred for further treatment to the Institute for Tropical Medicine at the University of Dusseldorf, where a treatment with ivermectin was conducted on the basis of positive staining with antibodies against filariae.

    CONCLUSION: Our case demonstrates the importance of interdisciplinary collaboration between breast center, pathology, and other specialties such as microbiology and tropical medicine.

    Matched MeSH terms: Ultrasonography
  7. Robert Peter J, Ho JJ, Valliapan J, Sivasangari S
    PMID: 26346107 DOI: 10.1002/14651858.CD008136.pub3
    BACKGROUND: Symphysis fundal height (SFH) measurement is commonly practiced primarily to detect fetal intrauterine growth restriction (IUGR). Undiagnosed IUGR may lead to fetal death as well as increase perinatal mortality and morbidity.

    OBJECTIVES: The objective of this review is to compare SFH measurement with serial ultrasound measurement of fetal parameters or clinical palpation to detect abnormal fetal growth (IUGR and large-for-gestational age), and improving perinatal outcome.

    SEARCH METHODS: We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (14 July 2015) and reference lists of retrieved articles.

    SELECTION CRITERIA: Randomised controlled trials including quasi-randomised and cluster-randomised trials involving pregnant women with singleton fetuses at 20 weeks' gestation and above comparing tape measurement of SFH with serial ultrasound measurement of fetal parameters or clinical palpation using anatomical landmarks.

    DATA COLLECTION AND ANALYSIS: Two review authors independently assessed trials for inclusion and risk of bias, extracted data and checked them for accuracy.

    MAIN RESULTS: One trial involving 1639 women was included. It compared SFH measurement with clinical abdominal palpation.There was no difference in the two reported primary outcomes of incidence of small-for-gestational age (risk ratio (RR) 1.32; 95% confidence interval (CI) 0.92 to 1.90, low quality evidence) or perinatal death.(RR 1.25, 95% CI 0.38 to 4.07; participants = 1639, low quality evidence). There were no data on the neonatal detection of large-for-gestational age (variously defined by authors). There was no difference in the reported secondary outcomes of neonatal hypoglycaemia, admission to neonatal nursery, admission to the neonatal nursery for IUGR (low quality evidence), induction of labour and caesarean section (very low quality evidence). The trial did not address the other outcomes specified in the 'Summary of findings' table (intrauterine death; neurodevelopmental outcome in childhood). GRADEpro software was used to assess the quality of evidence, downgrading of evidence was based on including a small single study with unclear risk of bias and a wide confidence interval crossing the line of no effect.

    AUTHORS' CONCLUSIONS: There is insufficient evidence to determine whether SFH measurement is effective in detecting IUGR. We cannot therefore recommended any change of current practice. Further trials are needed.

    Matched MeSH terms: Ultrasonography, Prenatal
  8. Khalid S, Aris MS
    BMJ Case Rep, 2016 Mar 30;2016.
    PMID: 27030452 DOI: 10.1136/bcr-2015-213165
    A 25-year-old gravida 2 para 1 with 12-week amenorrhoea presented a second time for recurrent vomiting in pregnancy. She was diagnosed to have a missed miscarriage following absent fetal heart seen in an early scan. She opted for conservative management. However, on the third presentation, her vomiting continued. Repeated transvaginal ultrasound scan showed a fetus with a crown rump length of 19 mm, which is equivalent to 8 weeks and 4 days, with absence of fetal heart pulsation. Thyroid function tests and β human chorionic gonadotropin were then requested. Results showed that the patient's serum β human chorionic gonadotropin level was markedly raised to 147,000. A molar pregnancy was suspected. Her thyroid function tests came back normal. Suction curettage was performed and histopathology confirmed a partial molar pregnancy. On follow-up, the β human chorionic gonadotropin level was normal by 7 weeks after the curettage.
    Matched MeSH terms: Ultrasonography, Prenatal
  9. Chin KY, Wan Ngah WZ, Ima-Nirwana S
    PMID: 27231930 DOI: 10.3390/ijerph13060531
    Male osteoporosis in Malaysia is a largely neglected problem. Therefore, a bone health study in men using quantitative ultrasonometry was launched as part of the Malaysian Aging Men Study in 2009-2012. This review aimed to summarize the findings of the aforementioned bone health study. The study examined the bone health of Chinese and Malaysian men aged 20 years and above living in Kuala Lumpur using a quantitative ultrasound device. Participants answered a questionnaire on their demographic details and physical activity status. Body anthropometry of the participants was measured and their blood collected for biochemical analysis. Results showed that a significant proportion of the Malaysian Chinese and Malay men had suboptimal bone health indicated by calcaneal speed of sound and vitamin D status. Age-related decline of the calcaneal speed of sound in these men was gradual and biphasic without ethnic difference. Body anthropometry such as height, weight, body mass index, and body fat percentage contributed to the variation of the calcaneal speed of sound in Malaysian men. Age-related changes in testosterone, insulin-like growth factor 1, and thyroid stimulating hormone also influenced the calcaneal speed of sound in these men. This study serves as a reminder that male osteoporosis in Malaysia should be an issue of concern. It is also a basis for a more comprehensive study on bone health in men in the future.
    Matched MeSH terms: Ultrasonography
  10. Chen CK, Teo SC, Phui VE, Saman MA
    Agri, 2015;27(4):210-4.
    PMID: 26860495 DOI: 10.5505/agri.2015.66487
    The application of ultrasound-guided transversus abdominis plane (TAP) block in paediatric population is gaining popularity among anaesthetists. We present a case series of ultrasound-guided TAP block in ten neonate and infants undergoing colostomy and reversal of stoma. Classical TAP as described by Hebbard was carried out and a maximum dosage of 1ml/kg of 0.25% levobupivacaine was injected. Pain score was assessed using Neonatal Infant Pain Scale for 24 hours. In all patients, the block was successful with minimal hemodynamic changes intraoperatively and no additional systemic analgesia was needed intraoperative and immediate postoperatively. Ultrasound-guided TAP block has an important role in providing safe and effective analgesia for colostomy creation and reversal of stoma surgeries in paediatric population.
    Matched MeSH terms: Ultrasonography
  11. Razali SNO, Arumugam T, Yuki N, Rozalli FI, Goh KJ, Shahrizaila N
    Clin Neurophysiol, 2016 Feb;127(2):1652-1656.
    PMID: 26228791 DOI: 10.1016/j.clinph.2015.06.030
    OBJECTIVE: To assess the longitudinal changes of nerve ultrasound in Guillain-Barré syndrome (GBS) patients.

    METHODS: We prospectively recruited 17 GBS patients and 17 age and gender-matched controls. Serial studies of their nerve conduction parameters and nerve ultrasound, documenting the cross-sectional areas (CSA), were performed at admission and repeated at several time points throughout disease course.

    RESULTS: Serial nerve ultrasound revealed significantly enlarged CSA in median, ulnar and sural nerves within the first 3 weeks of disease onset. Longitudinal evaluation revealed an improvement in the nerve CSA with time, reaching significance in the ulnar and sural nerves after 12 weeks. There was no significant difference between the demyelinating and axonal subtypes. There was also no significant correlation found between nerve CSA and neurophysiological parameters or changes in nerve CSA and muscle strength.

    CONCLUSION: In GBS, serial studies of peripheral nerve ultrasound CSA are helpful to detect a gradual improvement in the nerve size.

    SIGNIFICANCE: Serial nerve ultrasound studies could serve as a useful tool in demonstrating nerve recovery in GBS.

    Matched MeSH terms: Ultrasonography
  12. Foo LC, Zulfiqar A, Nafikudin M, Fadzil MT, Asmah AS
    Eur. J. Endocrinol., 1999 Jun;140(6):491-7.
    PMID: 10366404
    Iodine deficiency endemia is defined by the goitre prevalence and the median urinary iodine concentration in a population. Lack of local thyroid volume reference data may bring many health workers to use the European-based WHO/International Council for Control of Iodine Deficiency Disorders (ICCIDD)-recommended reference for the assessment of goitre prevalence in children in different developing countries. The present study was conducted in non-iodine-deficient areas in Malaysia to obtain local children's normative thyroid volume reference data, and to compare their usefulness with those of the WHO/ICCIDD-recommended reference for the assessment of iodine-deficiency disorders (IDD) in Malaysia.
    Matched MeSH terms: Ultrasonography
  13. Hess SY, Zimmermann MB
    Eur. J. Endocrinol., 2000 Jun;142(6):599-603.
    PMID: 10822222
    The determination of goiter prevalence in children by thyroid ultrasound is an important tool for assessing iodine deficiency disorders. The current World Health Organization/International Council for the Control of Iodine Deficiency Disorders (WHO/ICCIDD) normative values, based on thyroid volume in iodine-sufficient European children, have recently been questioned, as thyroid volumes in iodine-sufficient children from the USA and Malaysia are smaller than the WHO/ICCIDD reference data. Our objective was to describe ultrasonographic thyroid volumes in a representative national sample of iodine-sufficient Swiss school children, and to compare these with the current reference data for thyroid volume.
    Matched MeSH terms: Ultrasonography
  14. Hanna RM, Ashebu SD
    Australas Radiol, 2002 Sep;46(3):252-6.
    PMID: 12196231
    In a retrospective study of giant breast masses over a period of 20 years (1980-2000), we encountered 18 patients with fibroadenomas. Most of them were adolescents and young adults. The bimodal age incidence seen in Caucasians was not observed. The masses ranged from 6 to 15 cm in size and in the youngest patient, they were bilateral. All 18 patients were examined by mammography and 10 of them by ultrasonography (US) as well. The right breast was involved in 12 patients and the left in six. The diagnosis was confirmed pathologically in all patients, by excision biopsy in 17 patients and by fine needle aspiration cytology and excision biopsy in one patient. The radiological findings were the same as those previously described. All patients were treated by simple enuculation. There was only one recurrence over a follow-up period from 2 months to 3 years.
    Matched MeSH terms: Ultrasonography, Mammary
  15. Jeyamalar R, Chan SP
    Int J Cardiol, 1995 Nov 10;52(1):83-4.
    PMID: 8707441
    Thyrotoxicosis gives rise to a high output cardiac failure. Rarely, it can cause a dilated cardiomyopathy with severe impairment of myocardial function which improves significantly following treatment.
    Matched MeSH terms: Ultrasonography
  16. Segasothy M, Abdul Samad S, Zulfiqar A, Shaariah W, Morad Z, Prasad Menon S
    Nephron, 1994;66(1):62-6.
    PMID: 8107955
    Computed tomography (CT) and ultrasonography (US) were performed in 40 patients who had consumed excessive quantities of analgesics (> 1 kg) to compare their value in the diagnosis of analgesic nephropathy (AN). The computed tomography and sonographic features were renal papillary calcifications. Renal papillary necrosis (RPN) was documented in 20 of 40 patients by US and in 14 of 40 patients by CT. In 11 patients, both US and CT were positive. In 9 patients, US was positive whilst CT was negative. In 3 patients, CT was positive whilst US was negative. Prevalence of RPN was 50% using US and 35% using CT. Using US as a gold standard, sensitivity of CT was 55%, specificity 85%, positive predictive value 78.6% and negative predictive value 34.6%. Percent agreement with CT and US was 70%. Cohen's kappa statistic adjusting for chance agreement was 40%. Based on these results, it is found that US yielded a higher percentage of positive cases of RPN.
    Matched MeSH terms: Ultrasonography
  17. Ding PH
    Med J Malaysia, 1995 Mar;50(1):118-9.
    PMID: 7752968
    Matched MeSH terms: Ultrasonography
  18. Haron A, Hisham AN, Samad SA
    Med J Malaysia, 1994 Mar;49(1):86-9.
    PMID: 8057997
    A case of symptomatic polycystic liver disease treated by fenestration and segmental liver resection is reported. The intraoperative use of ultrasound to define the plane of liver resection is emphasised. No significant post-operative complication was encountered. The clinical presentation, management and treatment are discussed.
    Matched MeSH terms: Ultrasonography, Interventional
  19. Raman S, Rachagan SP, Boopalan P, Jeyarani S
    Med J Malaysia, 1986 Dec;41(4):361-4.
    PMID: 3312976
    A case of infantile polycystic kidneys diagnosed prenatally by ultrasound is presented here. This condition was confirmed at post-mortem following delivery of the child. The clinical and pathological features of this inheritable disease is discussed.
    Matched MeSH terms: Ultrasonography
  20. Ismail M, Arshat H, Pulcrano J, Royston P, Spieler J
    Contraception, 1989 Jan;39(1):53-71.
    PMID: 2642781
    The BIOSELF 110 is a hand-held, non-invasive electronic instrument that measures basal body temperature and cycle length, and automatically identifies the fertile and infertile phases of the menstrual cycle with flashing red light and green light signals, respectively. The device was evaluated in 77 cycles from 33 ovulatory women in Kuala Lumpur, Malaysia. Ultrasound monitoring of maximum follicular diameter (MFD) and urinary LH measurements with Ovustick were used as reference methods to estimate the time of ovulation and the fertile period. Based on the MFD day, the BIOSELF correctly identified the entire fertile period, and at least four fertile days, in 89% and 94% of the cycles studied, respectively. The mean duration of the fertile period as determined by the number of flashing red light days was 11.0 days (SD 2.9). The device correctly identified the onset of the postovulatory infertile phase in 94% of cycles, with a mean duration of about 10 (green light) days. The results were similar using the LH peak day as the reference method. The mean interval from the onset of the fertile period (first flashing red light day) to the MFD day was 6.9 days (SD 2.6), and from the MFD day to the end of the fertile period, 3.1 days (SD 2.2). The BIOSELF 110 showed itself to be a reliable device for identifying the fertile and infertile phases of the menstrual cycle and, thus, should be a useful aid for couples seeking pregnancy. Prospective clinical trials are underway to assess the contraceptive effectiveness of the device.
    Matched MeSH terms: Ultrasonography