Displaying publications 61 - 80 of 104 in total

Abstract:
Sort:
  1. Hani AF, Kumar D, Malik AS, Walter N, Razak R, Kiflie A
    Acad Radiol, 2015 Jan;22(1):93-104.
    PMID: 25481518 DOI: 10.1016/j.acra.2014.08.008
    Quantitative assessment of knee articular cartilage (AC) morphology using magnetic resonance (MR) imaging requires an accurate segmentation and 3D reconstruction. However, automatic AC segmentation and 3D reconstruction from hydrogen-based MR images alone is challenging because of inhomogeneous intensities, shape irregularity, and low contrast existing in the cartilage region. Thus, the objective of this research was to provide an insight into morphologic assessment of AC using multilevel data processing of multinuclear ((23)Na and (1)H) MR knee images.
  2. Hayrapetyan A, Tumasyan A, Adam W, Andrejkovic JW, Bergauer T, Chatterjee S, et al.
    Phys Rev Lett, 2024 Mar 15;132(11):111901.
    PMID: 38563916 DOI: 10.1103/PhysRevLett.132.111901
    A search is reported for near-threshold structures in the J/ψJ/ψ invariant mass spectrum produced in proton-proton collisions at sqrt[s]=13  TeV from data collected by the CMS experiment, corresponding to an integrated luminosity of 135  fb^{-1}. Three structures are found, and a model with quantum interference among these structures provides a good description of the data. A new structure is observed with a local significance above 5 standard deviations at a mass of 6638_{-38}^{+43}(stat)_{-31}^{+16}(syst)  MeV. Another structure with even higher significance is found at a mass of 6847_{-28}^{+44}(stat)_{-20}^{+48}(syst)  MeV, which is consistent with the X(6900) resonance reported by the LHCb experiment and confirmed by the ATLAS experiment. Evidence for another new structure, with a local significance of 4.7 standard deviations, is found at a mass of 7134_{-25}^{+48}(stat)_{-15}^{+41}(syst)  MeV. Results are also reported for a model without interference, which does not fit the data as well and shows mass shifts up to 150 MeV relative to the model with interference.
  3. Kulkarni DD, Tosh C, Venkatesh G, Senthil Kumar D
    Indian J Virol, 2013 Dec;24(3):398-408.
    PMID: 24426305 DOI: 10.1007/s13337-013-0171-y
    The emergence of Nipah virus (NiV) infection into the pig population and subsequently into the human population is believed to be due to changes in ecological conditions. In Malaysia, A major NiV outbreak occurred in pigs and humans from September 1998 to April 1999 that resulted in infection of 265 and death of 105 persons. About 1.1 million pigs had to be destroyed to control the outbreak. The disease was recorded in the form of a major outbreak in India in 2001 and then a small incidence in 2007, both the outbreaks in West Bengal only in humans without any involvement of pigs. There were series of human Nipah incidences in Bangladesh from 2001 till 2013 almost every year with mortality exceeding 70 %. The disease transmission from pigs acting as an intermediate host during Malaysian and Singapore outbreaks has changed in NIV outbreaks in India and Bangladesh, transmitting the disease directly from bats to human followed by human to human. The drinking of raw date palm sap contaminated with fruit bat urine or saliva containing NiV is the only known cause of outbreak of the disease in Bangladesh outbreaks. The virus is now known to exist in various fruit bats of Pteropus as well as bats of other genera in a wider belt from Asia to Africa.
  4. Hani AF, Kumar D, Malik AS, Ahmad RM, Razak R, Kiflie A
    Rheumatol Int, 2015 Jan;35(1):1-16.
    PMID: 24879325 DOI: 10.1007/s00296-014-3052-9
    Early detection of knee osteoarthritis (OA) is of great interest to orthopaedic surgeons, rheumatologists, radiologists, and researchers because it would allow physicians to provide patients with treatments and advice to slow the onset or progression of the disease. Early detection can be achieved by identifying early changes in selected features of degenerative articular cartilage (AC) using non-invasive imaging modalities. Magnetic resonance imaging (MRI) is becoming the standard for assessment of OA. The aim of this paper was to review the influence of MRI on the selection, detection, and measurement of AC features associated with early OA. Our review of the literature indicates that the changes associated with early OA are in cartilage thickness, cartilage volume, cartilage water content, and proteoglycan content that can be accurately, consistently, and non-invasively measured using MRI. Choosing an MR pulse sequence that provides the capability to assess cartilage physiology and morphology in a single acquisition and advanced multi-nuclei MRI is desirable. The results of the review indicate that using an ultra-high magnetic strength, MR imager does not affect early OA detection. In conclusion, MRI is currently the most suitable modality for early detection of knee OA, and future research should focus on the quantitative evaluation of early OA features using advances in MR hardware, software, and data processing with sophisticated image/pattern recognition techniques.
  5. Awasthi A, Kumar B, Gulati M, Vishwas S, Corrie L, Kaur J, et al.
    Pharm Res, 2022 Nov;39(11):2817-2829.
    PMID: 36195824 DOI: 10.1007/s11095-022-03401-z
    PURPOSE: The aim of current study is to formulate, optimize and characterize the developed formulation of Mesalamine-Curcumin Nanostructured Lipid Carriers (Mes-Cur NLCs).

    METHODS: It was formulated using high pressure homogenization followed by probe sonication and formulation variables were optimized using Central Composite Design. The particle size (PS), zeta potential (ZP), entrapment efficiency (EE), drug release, cytotoxicity on NIH 3T3 fibroblasts cells and HaCaT keratinocytes cells and efficacy on RAW264.7 cells for optimized formulation was determined.

    RESULTS: The PS, ZP and EE were found to be 85.26 nm, -23.7 ± 7.45 mV, 99.2 ± 2.62 % (Mes) and 84 ± 1.51 % (Cur), respectively. The good correlation between predicted and obtained value indicated suitability and reproducibility of experimental design. NLCs showed spherical shape as confirmed by TEM. In vitro drug release profile of prepared formulation showed that Mes exhibited 100 % release at 48 h, whereas Cur exhibited 82.23 ± 2.97% release at 120 h. Both the drugs exhibited sustained release upon incorporation into the NLCs. The absence of any significant cell death during MTT assay performed on NIH 3T3 fibroblasts cells and HaCaT keratinocytes cells indicated that NLCs' were safe for use. Furthermore, significant reduction in nitric oxide level during anti-inflammatory evaluation of formulation on RAW264.7 cells showed excellent potential for the formulation to treat inflammation. The formulation was found stable as no significant difference between the PS, ZP and EE of the fresh and aged NLCs was observed.

    CONCLUSION: The outcomes of study deciphered successful formulation of Mes-Cur NLCs.

  6. Sirunyan AM, Tumasyan A, Adam W, Bergauer T, Dragicevic M, Erö J, et al.
    Phys Rev Lett, 2021 Sep 17;127(12):122001.
    PMID: 34597080 DOI: 10.1103/PhysRevLett.127.122001
    The first measurement of the dependence of γγ→μ^{+}μ^{-} production on the multiplicity of neutrons emitted very close to the beam direction in ultraperipheral heavy ion collisions is reported. Data for lead-lead interactions at sqrt[s_{NN}]=5.02  TeV, with an integrated luminosity of approximately 1.5  nb^{-1}, are collected using the CMS detector at the LHC. The azimuthal correlations between the two muons in the invariant mass region 88.3. The back-to-back correlation structure from leading-order photon-photon scattering is found to be significantly broader for events with a larger number of emitted neutrons from each nucleus, corresponding to interactions with a smaller impact parameter. This observation provides a data-driven demonstration that the average transverse momentum of photons emitted from relativistic heavy ions has an impact parameter dependence. These results provide new constraints on models of photon-induced interactions in ultraperipheral collisions. They also provide a baseline to search for possible final-state effects on lepton pairs caused by traversing a quark-gluon plasma produced in hadronic heavy ion collisions.
  7. Tumasyan A, Adam W, Andrejkovic JW, Bergauer T, Chatterjee S, Damanakis K, et al.
    Phys Rev Lett, 2023 Sep 01;131(9):091803.
    PMID: 37721845 DOI: 10.1103/PhysRevLett.131.091803
    The first observation of the production of W^{±}W^{±} bosons from double parton scattering processes using same-sign electron-muon and dimuon events in proton-proton collisions is reported. The data sample corresponds to an integrated luminosity of 138  fb^{-1} recorded at a center-of-mass energy of 13 TeV using the CMS detector at the CERN LHC. Multivariate discriminants are used to distinguish the signal process from the main backgrounds. A binned maximum likelihood fit is performed to extract the signal cross section. The measured cross section for production of same-sign W bosons decaying leptonically is 80.7±11.2(stat) _{-8.6}^{+9.5}(syst)±12.1(model)  fb, whereas the measured fiducial cross section is 6.28±0.81(stat)±0.69(syst)±0.37(model)  fb. The observed significance of the signal is 6.2 standard deviations above the background-only hypothesis.
  8. Hayrapetyan A, Tumasyan A, Adam W, Andrejkovic JW, Bergauer T, Chatterjee S, et al.
    Phys Rev Lett, 2024 Mar 22;132(12):121901.
    PMID: 38579207 DOI: 10.1103/PhysRevLett.132.121901
    The observation of WWγ production in proton-proton collisions at a center-of-mass energy of 13 TeV with an integrated luminosity of 138  fb^{-1} is presented. The observed (expected) significance is 5.6 (5.1) standard deviations. Events are selected by requiring exactly two leptons (one electron and one muon) of opposite charge, moderate missing transverse momentum, and a photon. The measured fiducial cross section for WWγ is 5.9±0.8(stat)±0.8(syst)±0.7(modeling)  fb, in agreement with the next-to-leading order quantum chromodynamics prediction. The analysis is extended with a search for the associated production of the Higgs boson and a photon, which is generated by a coupling of the Higgs boson to light quarks. The result is used to constrain the Higgs boson couplings to light quarks.
  9. Sirunyan AM, Tumasyan A, Adam W, Andrejkovic JW, Bergauer T, Chatterjee S, et al.
    Phys Rev Lett, 2021 Jun 25;126(25):252003.
    PMID: 34241504 DOI: 10.1103/PhysRevLett.126.252003
    The Ξ_{b}^{-}π^{+}π^{-} invariant mass spectrum is investigated with an event sample of proton-proton collisions at sqrt[s]=13  TeV, collected by the CMS experiment at the LHC in 2016-2018 and corresponding to an integrated luminosity of 140  fb^{-1}. The ground state Ξ_{b}^{-} is reconstructed via its decays to J/ψΞ^{-} and J/ψΛK^{-}. A narrow resonance, labeled Ξ_{b}(6100)^{-}, is observed at a Ξ_{b}^{-}π^{+}π^{-} invariant mass of 6100.3±0.2(stat)±0.1(syst)±0.6(Ξ_{b}^{-})  MeV, where the last uncertainty reflects the precision of the Ξ_{b}^{-} baryon mass. The upper limit on the Ξ_{b}(6100)^{-} natural width is determined to be 1.9  MeV at 95% confidence level. The low Ξ_{b}(6100)^{-} signal yield observed in data does not allow a measurement of the quantum numbers of the new state. However, following analogies with the established excited Ξ_{c} baryon states, the new Ξ_{b}(6100)^{-} resonance and its decay sequence are consistent with the orbitally excited Ξ_{b}^{-} baryon, with spin and parity quantum numbers J^{P}=3/2^{-}.
  10. Sirunyan AM, Tumasyan A, Adam W, Ambrogi F, Bergauer T, Dragicevic M, et al.
    Phys Rev Lett, 2020 Oct 09;125(15):152001.
    PMID: 33095627 DOI: 10.1103/PhysRevLett.125.152001
    Using a data sample of proton-proton collisions at sqrt[s]=13  TeV, corresponding to an integrated luminosity of 140  fb^{-1} collected by the CMS experiment in 2016-2018, the B_{s}^{0}→X(3872)ϕ decay is observed. Decays into J/ψπ^{+}π^{-} and K^{+}K^{-} are used to reconstruct, respectively, the X(3872) and ϕ. The ratio of the product of branching fractions B[B_{s}^{0}→X(3872)ϕ]B[X(3872)→J/ψπ^{+}π^{-}] to the product B[B_{s}^{0}→ψ(2S)ϕ]B[ψ(2S)→J/ψπ^{+}π^{-}] is measured to be [2.21±0.29(stat)±0.17(syst)]%. The ratio B[B_{s}^{0}→X(3872)ϕ]/B[B^{0}→X(3872)K^{0}] is found to be consistent with one, while the ratio B[B_{s}^{0}→X(3872)ϕ]/B[B^{+}→X(3872)K^{+}] is two times smaller. This suggests a difference in the production dynamics of the X(3872) in B^{0} and B_{s}^{0} meson decays compared to B^{+}. The reported observation may shed new light on the nature of the X(3872) particle.
  11. Sirunyan AM, Tumasyan A, Adam W, Ambrogi F, Bergauer T, Dragicevic M, et al.
    Phys Rev Lett, 2020 Oct 09;125(15):151802.
    PMID: 33095594 DOI: 10.1103/PhysRevLett.125.151802
    The first observation is reported of the combined production of three massive gauge bosons (VVV with V=W, Z) in proton-proton collisions at a center-of-mass energy of 13 TeV. The analysis is based on a data sample recorded by the CMS experiment at the CERN LHC corresponding to an integrated luminosity of 137  fb^{-1}. The searches for individual WWW, WWZ, WZZ, and ZZZ production are performed in final states with three, four, five, and six leptons (electrons or muons), or with two same-sign leptons plus one or two jets. The observed (expected) significance of the combined VVV production signal is 5.7 (5.9) standard deviations and the corresponding measured cross section relative to the standard model prediction is 1.02_{-0.23}^{+0.26}. The significances of the individual WWW and WWZ production are 3.3 and 3.4 standard deviations, respectively. Measured production cross sections for the individual triboson processes are also reported.
  12. Hayrapetyan A, Tumasyan A, Adam W, Andrejkovic JW, Bergauer T, Chatterjee S, et al.
    Phys Rev Lett, 2023 Sep 01;131(9):091903.
    PMID: 37721839 DOI: 10.1103/PhysRevLett.131.091903
    A search for the rare η→μ^{+}μ^{-}μ^{+}μ^{-} double-Dalitz decay is performed using a sample of proton-proton collisions, collected by the CMS experiment at the CERN LHC with high-rate muon triggers during 2017 and 2018 and corresponding to an integrated luminosity of 101  fb^{-1}. A signal having a statistical significance well in excess of 5 standard deviations is observed. Using the η→μ^{+}μ^{-} decay as normalization, the branching fraction B(η→μ^{+}μ^{-}μ^{+}μ^{-})=[5.0±0.8(stat)±0.7(syst)±0.7(B_{2μ})]×10^{-9} is measured, where the last term is the uncertainty in the normalization channel branching fraction. This work achieves an improved precision of over 5 orders of magnitude compared to previous results, leading to the first measurement of this branching fraction, which is found to agree with theoretical predictions.
  13. Tumasyan A, Adam W, Andrejkovic JW, Bergauer T, Chatterjee S, Damanakis K, et al.
    Phys Rev Lett, 2023 Oct 13;131(15):151803.
    PMID: 37897747 DOI: 10.1103/PhysRevLett.131.151803
    We present an observation of photon-photon production of τ lepton pairs in ultraperipheral lead-lead collisions. The measurement is based on a data sample with an integrated luminosity of 404  μb^{-1} collected by the CMS experiment at a center-of-mass energy per nucleon pair of sqrt[s_{NN}]=5.02  TeV. The γγ→τ^{+}τ^{-} process is observed for τ^{+}τ^{-} events with a muon and three charged hadrons in the final state. The measured fiducial cross section is σ(γγ→τ^{+}τ^{-})=4.8±0.6(stat)±0.5(syst)  μb, where the second (third) term corresponds to the statistical (systematic) uncertainty in σ(γγ→τ^{+}τ^{-}) in agreement with leading-order QED predictions. Using σ(γγ→τ^{+}τ^{-}), we estimate a model-dependent value of the anomalous magnetic moment of the τ lepton of a_{τ}=0.001_{-0.089}^{+0.055}.
  14. Singh I, Kumar S, R Koloor SS, Kumar D, Yahya MY, Mago J
    Polymers (Basel), 2022 Nov 24;14(23).
    PMID: 36501501 DOI: 10.3390/polym14235098
    This work reports the comparison of heat-treated and non-heat-treated laminated object-manufactured (LOM) 3D-printed specimens from mechanical and morphological viewpoints. The study suggests that heat treatment of the FDM-printed specimen may have a significant impact on the material characteristics of the polymer. The work has been performed at two stages for the characterization of (a) non-heat-treated samples and (b) heat-treated samples. The results for stage 1 (non-heat-treated samples) suggest that the infill density: 70%, infill pattern: honeycomb, and six number of discs in a single LOM-manufactured sample is the optimized condition with a compression strength of 42.47 MPa. The heat treatment analysis at stage 2 suggests that a high temperature: 65 °C, low time interval: 10 min, works equally well as the low temperature: 55 °C, high time interval: 30 min. The post-heat treatment near Tg (65 °C) for a time interval of 10 min improved the compressive strength by 105.42%.
  15. Sikdar S, Kumar D, Basu S, Mohanty V, Naik J, Banerjee S
    Med J Malaysia, 2012 Feb;67(1):129-30.
    PMID: 22582568
  16. Hani AF, Kumar D, Malik AS, Razak R
    Magn Reson Imaging, 2013 Sep;31(7):1059-67.
    PMID: 23731535 DOI: 10.1016/j.mri.2013.01.007
    Osteoarthritis is a common joint disorder that is most prevalent in the knee joint. Knee osteoarthritis (OA) can be characterized by the gradual loss of articular cartilage (AC). Formation of lesion, fissures and cracks on the cartilage surface has been associated with degenerative AC and can be measured by morphological assessment. In addition, loss of proteoglycan from extracellular matrix of the AC can be measured at early stage of cartilage degradation by physiological assessment. In this case, a biochemical phenomenon of cartilage is used to assess the changes at early degeneration of AC. In this paper, a method to measure local sodium concentration in AC due to proteoglycan has been investigated. A clinical 1.5-T magnetic resonance imaging (MRI) with multinuclear spectroscopic facility is used to acquire sodium images and quantify local sodium content of AC. An optimised 3D gradient-echo sequence with low echo time has been used for MR scan. The estimated sodium concentration in AC region from four different data sets is found to be ~225±19mmol/l, which matches the values that has been reported for the normal AC. This study shows that sodium images acquired at clinical 1.5-T MRI system can generate an adequate quantitative data that enable the estimation of sodium concentration in AC. We conclude that this method is potentially suitable for non-invasive physiological (sodium content) measurement of articular cartilage.
  17. Balkrishna A, Kumar A, Arya V, Rohela A, Verma R, Nepovimova E, et al.
    Oxid Med Cell Longev, 2021;2021:3155962.
    PMID: 34737844 DOI: 10.1155/2021/3155962
    Nanotechnology is gaining significant attention, with numerous biomedical applications. Silver in wound dressings, copper oxide and silver in antibacterial preparations, and zinc oxide nanoparticles as a food and cosmetic ingredient are common examples. However, adverse effects of nanoparticles in humans and the environment from extended exposure at varied concentrations have yet to be established. One of the drawbacks of employing nanoparticles is their tendency to cause oxidative stress, a significant public health concern with life-threatening consequences. Cardiovascular, renal, and respiratory problems and diabetes are among the oxidative stress-related disorders. In this context, phytoantioxidant functionalized nanoparticles could be a novel and effective alternative. In addition to performing their intended function, they can protect against oxidative damage. This review was designed by searching through various websites, books, and articles found in PubMed, Science Direct, and Google Scholar. To begin with, oxidative stress, its related diseases, and the mechanistic basis of oxidative damage caused by nanoparticles are discussed. One of the main mechanisms of action of nanoparticles was unearthed to be oxidative stress, which limits their use in humans. Secondly, the role of phytoantioxidant functionalized nanoparticles in oxidative damage prevention is critically discussed. The parameters for the characterization of nanoparticles were also discussed. The majority of silver, gold, iron, zinc oxide, and copper nanoparticles produced utilizing various plant extracts were active free radical scavengers. This potential is linked to several surface fabricated phytoconstituents, such as flavonoids and phenols. These phytoantioxidant functionalized nanoparticles could be a better alternative to nanoparticles prepared by other existing approaches.
  18. Bisht D, Kumar D, Kumar D, Dua K, Chellappan DK
    Arch Pharm Res, 2021 May;44(5):439-474.
    PMID: 33893998 DOI: 10.1007/s12272-021-01328-4
    Artemisia and its allied species have been employed for conventional medicine in the Northern temperate regions of North America, Europe, and Asia for the treatments of digestive problems, morning sickness, irregular menstrual cycle, typhoid, epilepsy, renal problems, bronchitis malaria, etc. The multidisciplinary use of artemisia species has various other health benefits that are related to its traditional and modern pharmaceutical perspectives. The main objective of this review is to evaluate the traditional, modern, biological as well as pharmacological use of the essential oil and herbal extracts of Artemisia nilagirica, Artemisia parviflora, and other allied species of Artemisia. It also discusses the botanical circulation and its phytochemical constituents viz disaccharides, polysaccharides, glycosides, saponins, terpenoids, flavonoids, and carotenoids. The plants have different biological importance like antiparasitic, antimalarial, antihyperlipidemic, antiasthmatic, antiepileptic, antitubercular, antihypertensive, antidiabetic, anxiolytic, antiemetic, antidepressant, anticancer, hepatoprotective, gastroprotective, insecticidal, antiviral activities, and also against COVID-19. Toxicological studies showed that the plants at a low dose and short duration are non or low-toxic. In contrast, a high dose at 3 g/kg and for a longer duration can cause toxicity like rapid respiration, neurotoxicity, reproductive toxicity, etc. However, further in-depth studies are needed to determine the medicinal uses, clinical efficacy and safety are crucial next steps.
  19. Chai TT, Ee KY, Kumar DT, Manan FA, Wong FC
    Protein Pept Lett, 2021;28(6):623-642.
    PMID: 33319654 DOI: 10.2174/0929866527999201211195936
    Large numbers of bioactive peptides with potential applications in protecting against human diseases have been identified from plant sources. In this review, we summarized recent progress in the research of plant-derived bioactive peptides, encompassing their production, biological effects, and mechanisms. This review focuses on antioxidant, antimicrobial, antidiabetic, and anticancer peptides, giving special attention to evidence derived from cellular and animal models. Studies investigating peptides with known sequences and well-characterized peptidic fractions or protein hydrolysates will be discussed. The use of molecular docking tools to elucidate inter-molecular interactions between bioactive peptides and target proteins is highlighted. In conclusion, the accumulating evidence from in silico, in vitro and in vivo studies to date supports the envisioned applications of plant peptides as natural antioxidants as well as health-promoting agents. Notwithstanding, much work is still required before the envisioned applications of plant peptides can be realized. To this end, future researches for addressing current gaps were proposed.
  20. Sirunyan AM, Tumasyan A, Adam W, Andrejkovic JW, Bergauer T, Chatterjee S, et al.
    Eur Phys J C Part Fields, 2021;81(9):800.
    PMID: 34781320 DOI: 10.1140/epjc/s10052-021-09538-2
    The measurement of the luminosity recorded by the CMS detector installed at LHC interaction point 5, using proton-proton collisions at s = 13 TeV in 2015 and 2016, is reported. The absolute luminosity scale is measured for individual bunch crossings using beam-separation scans (the van der Meer method), with a relative precision of 1.3 and 1.0% in 2015 and 2016, respectively. The dominant sources of uncertainty are related to residual differences between the measured beam positions and the ones provided by the operational settings of the LHC magnets, the factorizability of the proton bunch spatial density functions in the coordinates transverse to the beam direction, and the modeling of the effect of electromagnetic interactions among protons in the colliding bunches. When applying the van der Meer calibration to the entire run periods, the integrated luminosities when CMS was fully operational are 2.27 and 36.3 fb - 1 in 2015 and 2016, with a relative precision of 1.6 and 1.2%, respectively. These are among the most precise luminosity measurements at bunched-beam hadron colliders.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links