Displaying publications 61 - 80 of 95 in total

Abstract:
Sort:
  1. Raizulnasuha Ab Rashid, Nurul Afifah Aziz, Ili Zawani Khairuddin, Wan Nordiana Wan Abdul Rahman, Norhayati Dollah
    MyJurnal
    Radiobiological model such as linear quadratic (LQ) is widely used in radiotherapy to predict the biophysical response of the tumour cell to the radiation. In clinical radiotherapy, LQ model is widely employed to plan treatment delivery and fractionation. Nevertheless, LQ model might not provide accurate prediction for high dose rate treatment. This study investigates the radiation cell survival responses using LQ model and alternative Multi-Target (MT) model. The experimental works were conducted in-vitro using HeLa cells that were irradiated using photon and electron beams of different energy. Cells irradiation were performed in full scatter condition and exposed to radiation doses ranges from 1 to 10 Gy. Clonogenic assay is used as an endpoint to obtain the cell survival curves which later be fitted with LQ and MT model. The results demonstrate that MT model produce the fitting curves that are closed to the experimental data compare to LQ model especially at high doses. Parameter analysis from both models indicates more biological damage inflicted by high energy electron beam. Correlation between the experimental cell survival data and radiobiological model analysis suggesting that alternative radiobiological model such as MT model could be applied in analysing cells’ radiation survival and damage in clinical radiotherapy.
  2. Mohd Fahmi Mohd Yusof, Puteri Nor Khatijah Abd Hamid, Abdul Aziz Tajuddin, Rokiah Hashim, Norriza Mohd Isa
    MyJurnal
    The mass attenuation coefficients of solid water phantoms, Perspex® phantoms and Rhizophora spp. particleboards were determined by using Compton scattering technique measured using Ludlum configuration. The gamma energy of 137Cs sealed source were measured at 30°, 45°, 60° and 75° angles providing scattered gamma energies between 337.72 and 564.09 keV. The mass attenuation coefficients of solid water and fabricated Rhizophora spp. particleboards were the nearest to XCOM values of water with average percentage of discrepancies of 6.8% and 5.9%, respectively. The results indicated similar attenuation properties of solid water and fabricated Rhizophora spp. particleboards and the suitability of the Ludlum configuration to determine the mass attenuation coefficient of materials using Compton scatter technique.
  3. Zal U’yun Wan Mahmood, Norfaizal Mohamed, Nita Salina Abu Bakar, Nur Hidaya Dmuliany Mohd Sidek
    MyJurnal
    Laboratory radiotracer experiment was performed to study the bioaccumulation of 109Cd and 134Cs in the Malaysian common fish White seabass (Lates calcarifer). The aim of this study was to compare the biokinetics of uptake these two contrasting radionuclides by White seabass in laboratory condition scale. Experiments were designed to determine the processes controlling uptake of both radionuclides following exposure via seawater. In this study, the curve shapes of the uptake kinetic of 109Cd and 134Cs in White seabass were slightly linear and gradually increased with increasing of exposure time but were not reach equilibrium in the period of the study of 21 days. This phenomenon can be concluded that radioelement concentrations of 109Cd and 134Cs; and exposure duration of this experiment may not adequately to reach steady-state condition for uptake kinetic of those radioelements in White seabass. Furthermore, this was indicated that the uptake rate of 109Cd was 1.79 times faster than 134Cs due to some factors may probably influenced the output of this experiment such as different element accumulation strategies, physiological, behavior of radioelements, etc.
  4. Zal U'yun Wan Mahmood, Norfaizal Mohamad, Nur Nazirah Johari
    MyJurnal
    Accumulation kinetic trends of cesium and cadmium in the Penaeus monodon were studied using Cs-134 and Cd-109 as a tracer. The objective of this study was to quantify the uptake and loss/depuration kinetic of these two radionuclides in the Penaeus monodon. Uptake and loss/depuration kinetic of these two radionuclides in the Penaeus monodon were varied widely, displayed a simple double kinetic model of linear and exponential trend with time unless modified by moulting at the stage in the mount cycle. Therefore, the variation of Cs-134 and Cd-109 bio-concentration factor could be concluded considerably influence by moulting cycle, environmental and biological condition as well as physico-chemical that direct effects on their uptake and loss/depuration kinetic.
  5. Mohd Amirul Syafiq Mohd Yunos, Zainal Abidin Talib, Wan Mahmood Mat Yunus, Liew, Josephine Ying Chyi, Paulus, Wilfred Sylvester
    MyJurnal
    Semiconductor thin films Copper Tin Selenide, Cu2SnSe3, a potential compound for solar cell applications or semiconductor radiation detector were prepared by thermal evaporation method onto well-cleaned glass substrates. The as-deposited films were annealed in flowing purified nitrogen N2, for 2 hours in a temperature range from 100˚C to 500˚C. The structure of as-deposited and annealed films has been studied by X-ray diffraction technique. The semi-quantitative analysis indicated from Reitveld refinement show that the samples composed of Cu2SnSe3 and SnSe. These studies revealed that the films were structured in mixed phase between cubic space group F-43m (no. 216) and orthorhombic space group P n m a (no. 62). The crystallite size and lattice strain were determined from Scherrer calculation method. The results show that increasing in annealing temperature resulted in direct increase in crystallite size and decrease in lattice strain.
  6. Sakinah Ariffin, Azhar Mohamad, Ratnam, Wickneswari
    Jurnal Sains Nuklear Malaysia, 2012;24(1):91-101.
    MyJurnal
    Colour is one of the most important traits in orchids and has created great interest in breeding programmes. Gamma irradiation is an alternative way for generation of somaclonal variation for new flower colours. Phenotypic changes are usually observed during screening and selection of mutants. Understanding of targeted gene expression level and evaluation of the changes facilitate in the development of functional markers for selection of desired flower colour mutants. Four Dendrobium orchid sequences (NCBI accessions: AM490639, AY41319, FM209429 and DQ462460) were selected to design gene specific primers based on information for chalcone synthase (CHS) from NCBI database. Quantitative real-time PCR (qPCR) was used to understand flower colour expression quantitatively derived from the CHS gene activities in different flower tissues (petal and sepal) from control Dendrobium Sonia (red purple), mutant DS 35-1/M (purple pink) and mutant DS 35-WhiteA. It was found that expression of CHS gene was highest in sepals of white flowers and lowest in both sepals and petals of purple pink flowers. Genomic DNA was amplified and PCR products were sequenced, aligned and compared. Sequence variations of CHS partial gene in Dendrobium Sonia mutants with different flower colour showed that two protein positions have been changed as compared to the control. These non-synonymous mutations may have contributed to the colour alterations in the white and purple pink mutants. This paper describes important procedures to quantify gene expression such as RNA isolation (quantity and quality), cDNA synthesis and primer design steps for CHS genes.
  7. M. Fahmi M. Yusof, Nornashriah A. Rashid, Reduan Abdullah
    MyJurnal
    The glow curve in TLD-100 was compared by applying long preheat time, short preheat time
    techniques and without preheat technique before the TLD readout. Fading effect of the TLD signal
    upon certain storage time with long preheat time (100°C, 10 minutes using the oven) and short
    preheat time techniques (100°C, 10 seconds using the reader) were also studied. 15 TLD-100 chips
    were used with 3 of the TLD chips were used for measuring background radiation. 12 TLD chips
    were annealed, irradiated, preheated long and short preheat time techniques) and analyzed. The TL
    signals output from TLD chips of without preheated were used as the control. Two sets of data were
    taken using TLD chips irradiated with 6 MV and 10 MV photon beams. TL signal output was
    recorded the highest for short preheat time, followed by long preheat time and no preheating. The
    TL signal loss upon certain storage time was also reduced when short preheat time technique was
    applied. By applying long preheat time technique the low temperature peak in the glow curve was
    completely removed for both energies. Whereas, TLD chips exposed to 6 MV and with short preheat
    time technique the low temperature peak did not disappear completely but decreased in intensity as
    compared to the control data by 19.80%, 37.69%, 48.19% and 100% at 24, 48, 72 and 96 hours
    after exposure prior to readout, respectively. Meanwhile, for 10 MV photon beam with short
    preheat time, the small peak intensity was reduced by 19.58% for readout at 24 hours after
    irradiation and 100% for 48,72 and 96 hours delayed time prior to readout. It was observed that
    the TLD-100 was highly dependent on preheat heating time before readout. Short preheat time
    technique was able to reduce post irradiation fading of TLD-100 dosimeters
  8. Mohd Fahmi Mohd Yusof, Nur Amirah Nabila Ramli, Mohd Fahrizuan Md Yusop, Reduan Abdullah
    MyJurnal
    This study evaluates the ImageJ software as dosimetric tools for analyzing the film dosimeter in high energy photons and electrons. The percentage depth dose of photons of 6 and 10 MV and electrons of 6 and 9 MeV were measured using the Gafchromic EBT2 film dosimeter. The films were scanned and analyzed using the Verisoft software and ImageJ. The beam profiles at nominal photon and electron beam parameters were also evaluated using the two methods. The PDD measured in ImageJ at high energy photons were in good agreement within 1% percentage of discrepancy at all depths in comparison to the Verisoft software. The PDD measured in ImageJ at high energy electrons also showed good agreement to Verisoft software within 8% percentage of discrepancy at all depths. The measured flatness of beam profiles at Dmax, R50, R80 and R90 in ImageJ were also in good agreement to Verisoft software with flatness value between 4 and 8%. The results indicated the suitability of ImageJ software as dosimetric tool for analyzing EBT2 film dosimeter at high energy photon and electrons.
  9. Puteri Nor Khatijah Abd Hamid, Abdul Aziz Tajuddin, Mohd Fahmi Mohd Yusof, Rokiah Hashim
    MyJurnal
    The particleboards were fabricated using Rhizophora spp. wood particles with particles size less than 74 μm. The corn starch was used as a bio-adhesive in the fabrication of Rhizophora spp. particleboards. The corn starch bonded particleboards were fabricated at 5% and 10% corn starch based on dry mass of Rhizophora spp. wood particles. The measurement of mass attenuation coefficients of the particleboards were made at low and intermediate photon energies. The mass attenuation coefficient at low photon energy was measured using X-ray fluorescent (XRF) configuration based on attenuation of Kα1 X-ray energies between 16.59 and 25.26 keV given by niobium, molybdenum, palladium and tin metal plates. The calculated mass attenuation coefficients of samples were compared to the theoretical values mass attenuation coefficients of water calculated using the photon cross-section database (XCOM). The results showed that mass attenuation coefficients of 10% corn starch added Rhizophora spp. particleboards were in good agreement of water within 7.96 and 4.94% for 5% and 10% corn starch Rhizophora spp. Particleboards, respectively compared to 14.57 and 16.16% in binderless Rhizophora spp. particleboards and raw Rhizophora spp. wood, respectively.
  10. Rokiah Mohd Sabri, Abd Halim Baijan, Siti A’iasah Hashim, Mohd Rizal Md Chulan, Leo, Kwee Wah, Mukhlis Mokhtar, et al.
    MyJurnal
    A 3.375 kJ plasma focus is designed to operate at 13.5 kV for studying X-ray source in Argon discharge. X-rays are detected by a film from the mammography radiographic plate using radiography technique. The feasibility of plasma focus as a high intensity flash X-ray radiation for a good contrast in radiography image is presented.
  11. Nor Mariah Adam, Rosli Darmawan
    MyJurnal
    One of the most prevailing issues in the operation of Nuclear Reactor is the safety of the system. Worldwide publicity on a few nuclear accidents as well as the notorious Hiroshima and Nagasaki bombing have always brought about public fear on anything related to nuclear. Most findings on the nuclear reactor accidents are closely related to the reactor cooling system. Thus, the understanding of the behaviour of reactor cooling system is very important to ensure the development and improvement on safety can be continuously done. Throughout the development of nuclear reactor technology, investigation and analysis on reactor safety have gone through several phases. In the early days, analytical and experimental methods were employed. For the last three decades ID system level codes were widely used. The continuous development of nuclear reactor technology has brought about more complex system and processes of nuclear reactor operation. More detailed dimensional simulation codes are needed to assess these new reactors. This paper discusses the development of 3D CFD usage in nuclear reactor safety analysis worldwide. A brief review on the usage of CFD at Malaysia's Reactor TRIGA PUSPATI is also presented.
  12. Rosli Darmawan
    MyJurnal
    The study on the possibility of using DMU Kinematics module in CAE tools for dose exposure work planning was carried out. A case scenario was created using 3D CAD software and transferred to DMU Kinematics module in a CAE software. The work plan created using DMU Kinematics module was animated to simulate a real time scenario. Data on the phantom position against the radioactive source was collected by activating positioning sensors in the module. The data collected was used to calculate the estimated dose rate exposure for the phantom. The results can be used to plan the safest and optimum procedures in carrying out the radiation related task.
  13. Yusof Abdullah, Mohd Reusmaazran Yusof, Nadira Kamarudin, Paulus, Wilfred Sylvester, Rusnah Mustaffa, Nurazila Mat Zali, et al.
    MyJurnal
    Al/B4C composites with 0 wt.%, 5 wt.% and 10 wt.% of B4C were prepared by powder metallurgy and their properties were characterised successfully. Investigation of the effect of milling times (4, 8, 12, 16 hours) on microstructure, phase identification, hardness and neutron attenuation coefficient of composites has been studied. The results showed that hardness increased with increased of milling time, with maximum hardness obtained at 16 hours milling time. The increment is slower as the composition of B4C increased. The hardness of Al/10%B4C, Al/5%B4C and Al/0%B4C were 81.7, 78.7 and 61.2 HRB respectively. Morphology of scanning electron microscopy (SEM) showed that microstructures play important role in controlling the hardness. Meanwhile, x-ray diffraction (XRD) analysis showed the phases and crystalline present in composites with an indication that crystalline of the grain increased as the milling time increased. Neutron absorption of Al/10%B4C composites showed that this composite has the highest attenuation coefficient, thus indicating that it is the best composites for neutron shielding.
  14. Pairu Ibrahim, Wan Manshol Wan Zain, Chai, Chee Keong, Sofian Ibrahim, Mohd Noorwadi Mat Lazim, Saadiah Sulaiman
    MyJurnal
    A safety evaluation test on human for latex films made from Radiation Prevulcanized Natural Rubber Latex (RVNRL) with sulfur-containing antioxidant was studied. Sulfur test has confirmed that there was sulfur compound presence in RVNRL derived from antioxidant used in this study. Two types of safety evaluation test were being adopted which are Patch Test and Modified Draize-95 test and this test proved that there is no clinical evidence on the presence of sulfur compound in RVNRL that may induce Type IV allergy in the unsensitized general user population. Both clinical test shows that the highest score value produced by test subjects is 1 and not exceed the allowable limit.
  15. Nazaratul Ashifa Abdullah Salim, Roslanzairi Mostapha, Zainon Othman, Nor Afiqah Harun, Mohd Suhaimi Hamzah, Shamsiah Abdul Rahman, et al.
    MyJurnal
    Stable isotope analysis has widely been used to trace the origin of organic materials in various fields, such as geochemistry, biochemistry, archeology and petroleum. In past a decade, it has also become an important tool for food traceability study. The globalisation of food markets and the relative ease which food commodities are transported through and between countries and continentsmeans that consumers are increasingly concerned about the origin of the foods they eat. The natural abundance of stable isotope variation such as carbon, nitrogen, hydrogen and oxygen are usedas geographic tracersor marker to determine the geographic origin of fruits, crop, vegetables and food products from animal. The isotopic compositions of plant materials reflect various factors such as isotopic compositions of source materials and their assimilation processes as well as growth environments. This paper will discuss on stable carbon and nitrogen isotopic compositions inricethat been determined by Isotope Ratio Mass Spectromety, advantages, limitations and potential of other analysis applicationsthat can be incorporated in food traceability system.
  16. Arwinder Singh, Lee Sing, Saw, Sor Heoh
    MyJurnal
    In this paper a study on the relationship between axial speed va, radial shock speed vs, piston speed
    vp and pinch temperature with the variation of pressure P0 was carried out. The Lee’s 5 phase
    model code was used in this study by configuring the India Bhabha Atomic Research Center
    (BARC) plasma focus machine to operate in the pressure (P0) range from 1 Torr to 14 Torr. The
    relationships between these parameters were obtained as follows:

    Va ≈ 9Po-0.37, Vs ≈ 45P0-0.48, Vp ≈ 30P0-0.47 and Tpinch(max) ≈ 11P0-1
  17. Aida Nazlyn Nazari, Azhar Mohamad, Shuhaimi Shamsudin
    MyJurnal
    Assessing performance and genetic diversity of the wild material of oil palm is important for
    under- standing genetic structure of natural oil palm populations towards improvement of the
    crops. This in-formation is important for oil palm breeding programs, and also for continued exsitu
    conservation of the germplasm and breeding program in Malaysia. Mutation induction is one
    of the approaches in creating variants for selection in the breeding program. In this study, the
    effect of irradiated pollen towards pollen viability, bunches formation and number of
    parthenocarpic fruits were evaluated. Elaies guineensis Jacq. pollens were exposed to series of
    acute gamma radiation at dose 0, 10, 20, 40, 50, 100, 200, 300, 500, 100 and 2000 Gy . Pollen
    viability and pollen tube formation were disrupted in which unable the pollen to reach the ovule.
    At this stage, embryo was aborted towards formation of parthenocarpic fruits and rotten bunches.
    The study suggested that at low levels of irradiation i.e. < 200 Gy, generative nucleus partially
    damage and it is still maintaining capacity of fertilizing the egg cells for hybridization. It is
    important for breeders in understanding this finding towards novel variants of oil palm via
    mutation induction
  18. Rosnani Abdul Rashid, Azhar Mohamad, Mat Rasol Awang, Hassan Hamdani Mutaat, Shaiful Azuar Mohamad, Affrida Abu Hasan, et al.
    MyJurnal
    Mushroom can be used as a biological indicator in assessing radiological impact on the
    environment. Radiological effect would be reflected through morphological changes as well as
    those changes at molecular level. For this purpose, a preliminary work was conducted, which
    included DNA isolation, optimization of PCR parameters for Inter-Simple Sequence Repeat (ISSR)
    and primers screening on Pleurotus sajor caju mushroom strains from Nuclear Malaysia’s
    Sterifeed Mushrooms Collection Centre. In this work, DNA isolation technique from cap and stalk
    of fruit body were optimized and quantified. It was found that stalk produced highest amount of
    genomic DNA at 304.01ng/µl and cap at 149.00ng/µl. A total of 100 ISSR primers were tested and
    51 primers were successfully amplified. These primers will be used further for dose response
    evaluation and molecular profiling in mushroom species.
  19. Norhayati Abdullah, Ng, Kwan Hoong, Wong, Jeannie Hsiu Ding, Ngie Min Ung, Taiman Kadni, Siti Sara Deraman
    MyJurnal
    The objective of this study is to perform a thermoluminescent dosimetry (TLD) postal dose quality audit for megavoltage X-ray teletherapy units in Malaysia. This audit is essential to be carried out to ensure adequate precision in the dosimetry of clinical beams before being delivered to the patients. Through this work, participating centres were requested to irradiate three capsules of TLD-100 powder with an absorbed dose to water of 2 Gy for 6MV and10MV photon beams. The International Atomic Energy Agency (IAEA)’s Technical Report Series No. 398 is used as a reference standard for TLD irradiation. Atotal of 22photon beamsfrom ten radiotherapy centres comprising onegovernment hospital and nineprivate medical centres were evaluated. The percentage deviation of user’s measured absorbed dose relative to Secondary Standard Dosimetry Laboratory (SSDL) mean absorbed dose was calculated. The results showed that all photon beams are within the IAEA’s acceptance limit of ± 5% except six photon beams. These centres were followed up with a second round of TLD irradiation which resulted in a better compliance.As a conclusion, regular audits should be performed to ensure consistency of radiotherapy treatment unit performances thus maintaining the accuracy of dose delivered to patients inall radiotherapy centres in Malaysia.
  20. Norazlina Noordin, Rusli Ibrahim, Nur Hidayah Mohd Sajahan, Salmah Moosa, Sobri Hussein
    MyJurnal
    Stevia rebaudiana Bertoni is a perennial herb that belongs to the family of Asteraceae. It is a
    natural sweetener plant known as sweet leaf, which is estimated to be 300 times sweeter than cane
    sugar. In this study, micropropagation and in vitro mutagenesis of this natural herb was
    successfully conducted. It was found that shoot tips on MS medium supplemented with 1 mg/l
    Kinetin showed the highest shoot induction and multiplication after 3 weeks of culture
    (5.50±1.95a). Radiosensitivity test was conducted to identify the dose that killed 50% of the
    irradiated explants (LD50) for in vitro stevia shoots and to select effective doses to be used for the in
    vitro mutagenesis. Shoot tips were irradiated with acute and chronic gamma radiation at 0, 10, 20,
    30, 40, 60, and 80Gy. At 60 Gy and 80 Gy, all treated shoot tips were not survived. In this study,
    LD50 for the stevia was estimated at 29 Gy for acute irradiation and 45 Gy for chronic irradiation.
    The effective doses were selected at 10, 20, 30 and 40 Gy. These selected doses were applied for the
    in vitro mutagenesis of the stevia shoots
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links