Displaying publications 61 - 80 of 1043 in total

Abstract:
Sort:
  1. Chin KY
    Postgrad Med, 2017 Sep;129(7):734-746.
    PMID: 28695762 DOI: 10.1080/00325481.2017.1353394
    The prevalence of osteoporosis in Asian countries is growing. An effective screening method will enable patients at risk for osteoporosis to receive early diagnosis and treatment, and avoid overcrowding the limited dual-energy x-ray absorptiometry (DXA) machines available in Asian countries. Many simple osteoporosis screening algorithms have been developed but they are not validated for use in Asian populations. osteoporosis self-assessment tools for Asians (OSTA), established using a multinational Asian cohort, is the first screening algorithm that caters for the Asian populations. It considers only body weight and age in the algorithm. It shows consistently high performance and sensitivity in identifying postmenopausal women at risk for osteoporosis in many Asian countries. Its usage has been expanded for identifying osteoporosis in men, as well as determining fracture risk for both sexes. However, the performance of OSTA is influenced by age, sex, ethnicity and site of BMD measurement to define osteoporosis. Its usage is also limited in individuals without apparent risk factors. These limitations should be noted by physicians considering the use of OSTA in clinical setting. As a conclusion, OSTA is a cost-effective measure for osteoporosis screening in primary healthcare setting.
    Matched MeSH terms: Sensitivity and Specificity
  2. Michelle Wong Tzeling J, Yean Yean C
    Analyst, 2016 Feb 21;141(4):1246-9.
    PMID: 26783560 DOI: 10.1039/c5an01741f
    A shelf-stable loop-mediated isothermal amplification (LAMP) reagent for Burkholderia pseudomallei detection is described. The coupling of LAMP reagents with the indirect colorimetric indicator and consequently its lyophilization enable the simple evaluation of results without the need for any advance laboratory instruments. The reagents were found to have a stable shelf life of at least 30 days with well-maintained sensitivity and specificity.
    Matched MeSH terms: Sensitivity and Specificity
  3. Namazi H, Kulish VV, Hussaini J, Hussaini J, Delaviz A, Delaviz F, et al.
    Oncotarget, 2016 Jan 5;7(1):342-50.
    PMID: 26586477 DOI: 10.18632/oncotarget.6341
    One of the main areas of behavioural neuroscience is forecasting the human behaviour. Epilepsy is a central nervous system disorder in which nerve cell activity in the brain becomes disrupted, causing seizures or periods of unusual behaviour, sensations and sometimes loss of consciousness. An estimated 5% of the world population has epileptic seizure but there is not any method to cure it. More than 30% of people with epilepsy cannot control seizure. Epileptic seizure prediction, refers to forecasting the occurrence of epileptic seizures, is one of the most important but challenging problems in biomedical sciences, across the world. In this research we propose a new methodology which is based on studying the EEG signals using two measures, the Hurst exponent and fractal dimension. In order to validate the proposed method, it is applied to epileptic EEG signals of patients by computing the Hurst exponent and fractal dimension, and then the results are validated versus the reference data. The results of these analyses show that we are able to forecast the onset of a seizure on average of 25.76 seconds before the time of occurrence.
    Matched MeSH terms: Sensitivity and Specificity
  4. Stinear T, Davies JK, Jenkin GA, Portaels F, Ross BC, Oppedisano F, et al.
    J Clin Microbiol, 2000 Apr;38(4):1482-7.
    PMID: 10747130
    Two high-copy-number insertion sequences, IS2404 and IS2606, were recently identified in Mycobacterium ulcerans and were shown by Southern hybridization to possess restriction fragment length polymorphism between strains from different geographic origins. We have designed a simple genotyping method that captures these differences by PCR amplification of the region between adjacent copies of IS2404 and IS2606. We have called this system 2426 PCR. The method is rapid, reproducible, sensitive, and specific for M. ulcerans, and it has confirmed previous studies suggesting a clonal population structure of M. ulcerans within a geographic region. M. ulcerans isolates from Australia, Papua New Guinea, Malaysia, Surinam, Mexico, Japan, China, and several countries in Africa were easily differentiated based on an array of 4 to 14 PCR products ranging in size from 200 to 900 bp. Numerical analysis of the banding patterns suggested a close evolutionary link between M. ulcerans isolates from Africa and southeast Asia. The application of 2426 PCR to total DNA, extracted directly from M. ulcerans-infected tissue specimens without culture, demonstrated the sensitivity and specificity of this method and confirmed for the first time that both animal and human isolates from areas of endemicity in southeast Australia have the same genotype.
    Matched MeSH terms: Sensitivity and Specificity
  5. Wan Nor Amilah WA, Noor Izani NJ, Ng WK, Ashraful Haq J
    Trop Biomed, 2012 Dec;29(4):588-97.
    PMID: 23202604
    Clinical utilization of carbapenems remains under threat with the emergence of acquired carbapenemase-producing bacteria, particularly metallo-β-lactamases (MBL). Rapid detection of MBL-producing Gram-negative bacilli is essential to prevent their widespread dissemination. However, no standardized detection method is available for routine laboratory use. The purpose of the study was to evaluate a chelating-agent based double disk synergic test and disk potentiation test for MBL-producing strain detection and to determine the isolation rate of MBL-producing Pseudomonas aeruginosa and Acinetobacter from clinical samples in our tertiary teaching hospital. A total of 22 and 66 imipenem-resistant P. aeruginosa and Acinetobacter isolates respectively were tested with ceftazidime (CAZ) disk by modified double disk synergic test and disk potentiation test using ethylenediaminetetraacetic acid (EDTA) and 2-mercaptopropionic acid (as chelating agents) to detect MBL production. The tests were compared with EDTA-phenanthroline-imipenem (EPI) microdilution MIC test as gold standard. MBL positive strains were detected in 17 (77.3%) P. aeruginosa and 2 (3.5%) Acinetobacter isolates. The disk potentiation test with 2-mercaptopropionic acid (2-MPA) dilution of 1:12 provided the most acceptable sensitivities and specificities (88.2% sensitivity and 100% specificity in P. aeruginosa; 100% sensitivity and specificity in Acinetobacter) compared to other screening methods used in this study. This study provided useful information on the local prevalence of MBL-producing P. aeruginosa and Acinetobacter in our hospital. Disc potentiation test with CAZ/2-MPA disc appears to be reliable and convenient MBL detection method in the routine clinical laboratory.
    Matched MeSH terms: Sensitivity and Specificity
  6. Banjade DP, Shrestha SL, Shukri A, Tajuddin AA, Bhat M
    Australas Phys Eng Sci Med, 2002 Sep;25(3):110-8.
    PMID: 12416587
    This is a study using LiF:Mg;Ti thermoluminescent dosimeter (TLD) rods in phantoms to investigate the effect of lack of backscatter on exit dose. Comparing the measured dose with anticipated dose calculated using tissue maximum ratio (TMR) or percentage depth dose (PDD) gives rise to a correction factor. This correction factor may be applied to in-vivo dosimetry results to derive true dose to a point within the patient. Measurements in a specially designed humanoid breast phantom as well as patients undergoing radiotherapy treatment were also been done. TLDs with reproducibility of within +/- 3% (1 SD) are irradiated in a series of measurements for 6 and 10 MV photon beams from a medical linear accelerator. The measured exit doses for the different phantom thickness for 6 MV beams are found to be lowered by 10.9 to 14.0% compared to the dose derived from theoretical estimation (normalized dose at dmax). The same measurements for 10 MV beams are lowered by 9.0 to 13.5%. The variations of measured exit dose for different field sizes are found to be within 2.5%. The exit doses with added backscatter material from 2 mm up to 15 cm, shows gradual increase and the saturated values agreed within 1.5% with the expected results for both beams. The measured exit doses in humanoid breast phantom as well as in the clinical trial on patients undergoing radiotherapy also agreed with the predicted results based on phantom measurements. The authors' viewpoint is that this technique provides sufficient information to design exit surface bolus to restore build down effect in cases where part of the exit surface is being considered as a target volume. It indicates that the technique could be translated for in vivo dose measurements, which may be a conspicuous step of quality assurance in clinical practice.
    Matched MeSH terms: Sensitivity and Specificity
  7. Rashid NR, Ali ME, Hamid SB, Rahman MM, Razzak MA, Asing, et al.
    PMID: 25906074 DOI: 10.1080/19440049.2015.1039073
    Being the third-largest primate population has not made macaque (Macaca fascicularis sp.) monkeys less exposed to threats and dangers. Despite wildlife protection, they have been widely hunted and consumed in several countries because of their purported nutritional values. In addition to trading as pure bush meats in several places, monkey meat has been sold in meatball and soup products in Indonesia. Thus the possibility of macaque meat trafficking under the label of common meats is quite high. This paper reports the development of a polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP) assay with the shortest amplicon length for the confirmed detection of monkey meat under compromised states which are known to degrade DNA. We amplified a 120-bp region of d-loop gene using a pair of macaque-specific primers and confirmed their specificity for the target species through cross-challenging against 17 different species using a 141-bp site of an 18 S rRNA gene as an endogenous control for eukaryotes. This eliminated the possibilities of any false-negative detection with complex matrices or degraded specimens. The detection limit was 0.00001 ng DNA in a pure state and 0.1% of meat in mixed matrices and commercial meatball products. RFLP analysis further authenticated the originality of the PCR product and distinctive restriction patterns were found upon AluI and CViKI-1 digestion. A micro-fluidic lab-on-a-chip automated electrophoretic system separated the fragments with high resolution. The assay was validated for screening commercial meatball products with sufficient internal control.
    Matched MeSH terms: Sensitivity and Specificity
  8. Ali ME, Asing, Hamid SB, Razzak MA, Rashid NR, Al Amin M, et al.
    PMID: 26062948 DOI: 10.1080/19440049.2015.1058535
    Malayan box turtle (Cuora amboinensis) has been a wildlife-protected vulnerable turtle species in Malaysia since 2005. However, because of its purported usage in traditional medicine, tonic foods and feeds, clandestine black market trade is rampant. Several polymerase chain reaction (PCR) assays for the taxonomic detection and classification of turtle species have been proposed. These assays are based on long-length target amplicons which are assumed to break down under compromised states and, hence, might not be suitable for the forensic tracing and tracking of turtle trafficking. For the first time this paper develops a very short-amplicon-length PCR assay (120 bp) for the detection of Malayan box turtle meat in raw, processed and mixed matrices, and experimental evidence is produced that such an assay is not only more stable and reliable but also more sensitive than those previously published. We checked the assay specificity against 20 different species and no cross-species detection was observed. The possibility of any false-negative detection was eliminated by a universal endogenous control for eukaryotes. The assay detection limit was 0.0001 ng of box turtle DNA from pure meat and 0.01% turtle meat in binary and ternary admixtures and commercial meatballs. Superior target stability and sensitivity under extreme treatments of boiling, autoclaving and microwave cooking suggested that this newly developed assay would be suitable for any forensic and/or archaeological identification of Malayan box turtle species, even in severely degraded specimens. Further, in silico studies indicated that the assay has the potential to be used as a universal probe for the detection of nine Cuora species, all of which are critically endangered.
    Matched MeSH terms: Sensitivity and Specificity
  9. Goh KH, Goh ML, Thean ET, Khalid BA
    Med J Malaysia, 1992 Dec;47(4):248-60.
    PMID: 1303476
    A supersensitive ELISA was developed for measurement of thyroid-stimulating hormone (TSH) concentrations in serum using in-house rabbit polyclonal antisera and a commercial monoclonal antibody. The assay was optimised and validated by recovery, linearity and cross-reactivity experiments and further compared to other available assays and EQAS samples. Good precision was obtained with a working assay range of 0.2 to 100 mIU/L with < 10% coefficient of variation (CV) for both intra and interassay. The assay is highly sensitive and specific with a minimum detectable limit of 0.07 mIU/L and negligible cross-reactivities against LH, FSH, HCG and other pituitary peptides. Good correlations were obtained when compared to Abbott hTSH EIA (r = 0.993; p < 0.001; n = 85) and NETRIA IRMA (r + 0.995; p < 0.001; n = 76). The normal reference range established was 0.4 to 4.0 mIU/L (n = 76). TSH levels in serum of thyrotoxic patients (n = 83) were significantly lower (0.07 to 0.20 mIU/L, p < 0.0001) and completely distinct from normal values thereby obviating the requirement of a TRH-stimulation test. Stability studies showed that coated wells can be stored at 4 degrees C for at least 2 months. This highly sensitive in-house hTSH ELISA which is cheap, stable and readily available is useful for diagnosis and management of patients with various thyroid disorders.
    Matched MeSH terms: Sensitivity and Specificity
  10. Al-Qdah M, Ramli AR, Mahmud R
    Comput Biol Med, 2005 Dec;35(10):905-14.
    PMID: 16310014
    This paper uses wavelets in the detection comparison of breast cancer among the three main races in Malaysia: Chinese, Malays, and Indians followed by a system that evaluates the radiologist's findings over a period of time to gauge the radiologist's skills in confirming breast cancer cases. The db4 wavelet has been utilized to detect microcalcifications in mammogram-digitized images obtained from Malaysian women sample. The wavelet filter's detection evaluation was done by visual inspection by an expert radiologist to confirm the detection results of those pixels that corresponded to microcalcifications. Detection was counted if the wavelet-detected pixels corresponded to the radiologist's identified microcalcification pixels. After the radiologist's detection confirmation a new client-server radiologist recording and evaluation system is designed to evaluate the findings of the radiologist over some period of cancer detection working time. It is a system that records the findings of the Malaysian radiologist for the presence of breast cancer in Malaysian patients and provides a way of registering the progress of detecting breast cancer of the radiologist by tracking certain metric values such as the sensitivity, specificity, and receiver operator curve (ROC). The initial findings suggest that no single race mammograms are easier for wavelets' detections of microcalcifications and for the radiologist confirmation even though for this study the Chinese race samples detection average were a few percentages less than the other two races, namely the Malay and Indian races.
    Matched MeSH terms: Sensitivity and Specificity
  11. Rassiah P, Ng KH, DeWerd LA, Kunugi K
    Australas Phys Eng Sci Med, 2004 Mar;27(1):25-9.
    PMID: 15156705
    A thermoluminescent dosimetry (TLD) postal dose inter-comparison was carried out amongst radiotherapy centres in Malaysia. The aim of this TLD inter-comparison was to compare the uniformity involved in the measurement of absorbed dose among the participating centres. A set of 5 TLD chips placed within acrylic trays were mailed to all participating centres for irradiation to an absorbed dose to water of 2 Gy. Measurements were made for 6 MV and 60Co photon beams. Results show an agreement of +/- 5% for all but three radiotherapy centres. The ratios of the TLD readings to that of the reference centre are comparable with other national/regional dose inter-comparisons. The importance of a proper ongoing quality assurance program is essential in maintaining the consistency and uniformity of doses delivered.
    Matched MeSH terms: Sensitivity and Specificity
  12. Jirjees F, Soliman K, Wang Y, Sonawane R, Sheshala R, Jones D, et al.
    J Pharm Biomed Anal, 2019 Sep 10;174:145-150.
    PMID: 31167158 DOI: 10.1016/j.jpba.2019.05.038
    Bevacizumab is a full-length human monoclonal antibody used to treat various neovascular diseases such as wet age-related macular degeneration (AMD), diabetic eye disease and other problems of the retina. Monthly intravitreal injections of bevacizumab (Avastin®) are effective in the treatment of wet AMD. However, there is a growing demand in the development of sustained release ophthalmic formulations. Therefore, this study aims, for the first time, to develop a rapid, simple, and sensitive method using size exclusion chromatography coupled with fluorescence detection for routine quantification of bevacizumab in ophthalmic formulations and during in vitro release studies. The selected chromatographic conditions included an aqueous mobile phase composed of 35 mM sodium phosphate buffer and 300 mM sodium chloride (pH 6.8), a flow rate of 0.5 mL/min, and the fluorescence detector was operated at excitation and emission wavelengths of 280 and 340 nm, respectively. The peak area-concentration relationship maintained its linearity over concentration range of 0.1-20 μg/mL (R2 = 0.9993), and the quantitation limit was 100 ng/mL. The method was validated for specificity, accuracy, precision, and robustness. The developed method had a run time of 6 min at temperature 25 °C, making it a unique validated method for rapid and cost-effective quantification of bevacizumab.
    Matched MeSH terms: Sensitivity and Specificity
  13. Kan CH, Lee SK, Low CS, Velusamy SS, Cheong I
    Int J Clin Pract, 2000 Dec;54(10):645-6.
    PMID: 11221275
    A cross-sectional study was conducted on 160 Malaysian patients to validate the usefulness of the Siriraj Stroke Score (SSS) for differentiating intracerebral haemorrhage and infarction following acute strokes. Our results indicate that the score lacks sensitivity and specificity. It should thus not be used in epidemiological studies to determine stroke types in a community. More importantly, in the absence of information from neuroimaging of the brain, it cannot be used safely by physicians to assess the need or otherwise of thrombolytic and/or anticoagulant therapy after an acute stroke.
    Matched MeSH terms: Sensitivity and Specificity
  14. Othman S, Lee PY, Lam JY, Philip N, Azhari NN, Affendy NB, et al.
    PeerJ, 2022;10:e12850.
    PMID: 35291487 DOI: 10.7717/peerj.12850
    BACKGROUND: Leptospirosis is a zoonotic disease caused by bacteria of the genus Leptospira that affects both humans and animals worldwide. Early detection of the pathogen in humans is crucial for early intervention and control of the progression of the disease to a severe state. It is also vitally important to be able to detect the presence of the pathogen in carrier animals to control the spread of the disease from the environment. Here we developed a simple and rapid loop-mediated isothermal amplification (LAMP) assay targeting the leptospiral secY gene.

    RESULTS: Several reaction conditions of the LAMP reaction were optimized to ensure efficient amplification of the target DNA. The sensitivity of the developed LAMP assay obtained using a pure Leptospira culture was 2 × 104 copies of genomic DNA per reaction (equivalent to 0.1 ng) for a 40-minute reaction time. No cross-reactions were observed in the LAMP reaction against a series of non-leptospiral bacteria, indicating a specific reaction. The applicability of the LAMP assay was demonstrated on human blood and urine specimens collected from suspected leptospirosis patients and rat kidney specimens collected from suspected leptospirosis outbreak areas and high-risk areas. The developed LAMP assay demonstrated a higher detection rate for leptospiral DNA compared with the polymerase chain reaction (PCR) assay, possibly due to the presence of inhibitory substances, especially in rat kidney specimens, to which the PCR method is more susceptible. The present findings also highlight the importance of urine sample collection from patients for routine monitoring of the disease.

    CONCLUSIONS: In short, the developed LAMP assay can serve as a feasible alternative tool for the diagnosis of leptospirosis and be used for epidemiological and environmental surveillance of the disease, considering its robustness, rapidity, sensitivity, and specificity, as demonstrated in this study.

    Matched MeSH terms: Sensitivity and Specificity
  15. Lai MY, Ponnampalavanar SSS, Omar SFS, Lau YL
    Acta Trop, 2024 Mar;251:107120.
    PMID: 38199452 DOI: 10.1016/j.actatropica.2024.107120
    Combining the advantages of PCR and LAMP, we described a new technique, namely PCR-LAMP, for malaria diagnosis. The whole process of DNA amplification can be completed in 35 min. This hybrid amplification technique markedly improved the sensitivity of detection compared to the classic single PCR or LAMP assay alone. PCR-LAMP assay had a detection limit of 1 copy/µL for P. knowlesi and P. ovale, 0.1 copy/µL for P. vivax, P. falciparum and P. malariae, respectively. To facilitate the endpoint detection, xylenol orange was added. Positive samples were indicated in orange while negative reactions were violet. The inclusion of xylenol orange into the LAMP reaction mix significantly reduces the post-amplification workload. Without relying on the use of specific instruments, the color changes of the amplicons could be visualized directly through the naked eye. In conclusion, PCR-LAMP poses the potential to be developed as a new malaria molecular diagnosis tool.
    Matched MeSH terms: Sensitivity and Specificity
  16. Ong TK, Chin SP, Liew CK, Chan WL, Seyfarth MT, Liew HB, et al.
    Am Heart J, 2006 Jun;151(6):1323.e1-6.
    PMID: 16781246
    The new 64-row multidetector computed tomography (CT)-assisted angiography can now detect coronary artery disease with shorter breath-hold time and at faster heart rates for symptomatic patients. We aim to determine if the 64-row scanner can also overcome limitations due to mild to moderate calcification.
    Matched MeSH terms: Sensitivity and Specificity
  17. Sharifah MI, Lee CL, Suraya A, Johan A, Syed AF, Tan SP
    Knee Surg Sports Traumatol Arthrosc, 2015 Mar;23(3):826-30.
    PMID: 24240983 DOI: 10.1007/s00167-013-2766-7
    PURPOSE: This study was conducted to evaluate the accuracy of magnetic resonance imaging (MRI) in diagnosing meniscal tears in patients with anterior cruciate ligament (ACL) tears and to determine the frequency of missed meniscal tears on MRI.

    METHODS: This prospective comparative study was conducted from 2009 to 2012. Patients with ACL injuries who underwent knee arthroscopy and MRI were included in the study. Two radiologists who were blinded to the clinical history and arthroscopic findings reviewed the pre-arthroscopic MR images. The presence and type of meniscal tears on MRI and arthroscopy were recorded. Arthroscopic findings were used as the reference standard. The accuracy, sensitivity, specificity, negative predictive value (NPV), and positive predictive value (PPV) of MRI in the evaluation of meniscal tears were calculated.

    RESULTS: A total of 65 patients (66 knees) were included. The sensitivity, specificity, accuracy, PPV, and NPV for the MRI diagnosis of lateral meniscal tears in our patients were 83, 97, 92, 96, and 90 %, respectively, whereas those for medial meniscus tears were 82, 92, 88, 82, and 88 %, respectively. There were five false-negative diagnoses of medial meniscus tears and four false-negative diagnoses of lateral meniscus tears. The majority of missed meniscus tears on MRI affected the peripheral posterior horns.

    CONCLUSION: The sensitivity for diagnosing a meniscal tear was significantly higher when the tear involved more than one-third of the meniscus or the anterior horn. The sensitivity was significantly lower for tears located in the posterior horn and for vertically oriented tears. Therefore, special attention should be given to the peripheral posterior horns of the meniscus, which are common sites of injury that could be easily missed on MRI. The high NPVs obtained in this study suggest that MRI is a valuable tool prior to arthroscopy.

    Matched MeSH terms: Sensitivity and Specificity
  18. Fauziah D, Anggoro R R
    Malays J Pathol, 2020 Dec;42(3):409-414.
    PMID: 33361722
    BACKGROUND: Ovarian tumours are a very heterogeneous group of tumours, consisted of non-neoplastic and neoplastic lesions. Preoperative diagnoses in most conditions are inconclusive due to similar clinical, radiological and laboratory findings. Intraoperative consultation is crucial because it can provide rapid diagnosis leading to a suitable surgical management for the patients.

    OBJECTIVE: To obtain profile, accuracy and concordance rates of ovarian intraoperative consultation in Dr. Soetomo Hospital Surabaya, a teaching hospital in Indonesia.

    MATERIALS AND METHODS: Observational retrospective study, using data from archives of intraoperative consultation reports in Dr. Soetomo General Hospital Surabaya within 2012-2016 period. There were 734 cases of ovarian intraoperative consultations, all then proceed to permanent sections. Accuracy, sensitivity, and specificity rates were calculated.

    RESULTS: Overall accuracy was 89.5%. Sensitivity for benign, borderline and malignant cases were 98.49%, 71.19% and 84.01%, respectively. Specificity were 90.32%, 95.11% and 98.72%, respectively.

    CONCLUSION: Intraoperative consultation for ovarian tumours has a reliable diagnostic value in benign and malignant lesion, but lower value in borderline tumours.

    Matched MeSH terms: Sensitivity and Specificity
  19. Mohd Zaki F, Moineddin R, Grant R, Chavhan GB
    Pediatr Radiol, 2016 Nov;46(12):1684-1693.
    PMID: 27406610
    BACKGROUND: Safety concerns are increasingly raised regarding the use of gadolinium-based contrast media for MR imaging.

    OBJECTIVE: To determine the accuracy of pre-contrast abdominal MR imaging for lesion detection and characterization in pediatric oncology patients.

    MATERIALS AND METHODS: We included 120 children (37 boys and 83 girls; mean age 8.94 years) referred by oncology services. Twenty-five had MRI for the first time and 95 were follow-up scans. Two authors independently reviewed pre-contrast MR images to note the following information about the lesions: location, number, solid vs. cystic and likely nature. Pre- and post-contrast imaging reviewed together served as the reference standard.

    RESULTS: The overall sensitivity was 88% for the first reader and 90% for the second; specificity was 94% and 91%; positive predictive value was 96% and 94%; negative predictive value was 82% and 84%; accuracy of pre-contrast imaging for lesion detection as compared to the reference standard was 90% for both readers. The difference between mean number of lesions detected on pre-contrast imaging and reference standard was not significant for either reader (reader 1, P = 0.072; reader 2, P = 0.071). There was substantial agreement (kappa values of 0.76 and 0.72 for readers 1 and 2) between pre-contrast imaging and reference standard for determining solid vs. cystic lesion and likely nature of the lesion. The addition of post-contrast imaging increased confidence of both readers significantly (P 

    Matched MeSH terms: Sensitivity and Specificity
  20. Kanagasingam S, Hussaini HM, Soo I, Baharin S, Ashar A, Patel S
    Int Endod J, 2017 May;50(5):427-436.
    PMID: 27063356 DOI: 10.1111/iej.12651
    AIM: To compare the accuracy of film and digital periapical radiography (PR) in detecting apical periodontitis (AP) using histopathological findings as a reference standard.

    METHODOLOGY: Jaw sections containing 67 teeth (86 roots) were collected from nine fresh, unclaimed bodies that were due for cremation. Imaging was carried out to detect AP lesions using film and digital PR with a centred view (FP and DP groups); film and digital PR combining central with 10˚ mesially and distally angled (parallax) views (FPS and DPS groups). All specimens underwent histopathological examination to confirm the diagnosis of AP. Sensitivity, specificity and predictive values of PR were analysed using rater mean (n = 5). Receiver operating characteristics (ROC) analysis was carried out.

    RESULTS: Sensitivity was 0.16, 0.37, 0.27 and 0.38 for FP, FPS, DP and DPS, respectively. Both FP and FPS had specificity and positive predictive values of 1.0, whilst DP and DPS had specificity and positive predictive values of 0.99. Negative predictive value was 0.36, 0.43, 0.39 and 0.44 for FP, FPS, DP and DPS, respectively. Area under the curve (AUC) for the various imaging methods was 0.562 (FP), 0.629 (DP), 0.685 (FPS), 0.6880 (DPS).

    CONCLUSIONS: The diagnostic accuracy of single digital periapical radiography was significantly better than single film periapical radiography. The inclusion of two additional horizontal (parallax) angulated periapical radiograph images (mesial and distal horizontal angulations) significantly improved detection of apical periodontitis.

    Matched MeSH terms: Sensitivity and Specificity
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links