OBJECTIVES:: The aim was to investigate their dynamic characteristics and create a relationship between these dynamic data and the prescription of foot.
STUDY DESIGN:: Experimental Assessment.
METHODS:: This article presents the modal analysis results of the full range of Össur Flex-Run™ running feet that are commercially available (1LO-9LO) using experimental modal analysis technique under a constant mass at 53 kg and boundary condition.
RESULTS:: It was shown that both the undamped natural frequency and stiffness increase linearly from the lowest to the highest stiffness category of foot which allows for a more informed prescription of foot when tuning to a matched natural frequency. The low damping characteristics determined experimentally that ranged between 1.5% and 2.0% indicates that the feet require less input energy to maintain the steady-state cyclic motion before take-off from the ground. An analysis of the mode shapes also showed a unique design feature of these feet that is hypothesised to enhance their performance.
CONCLUSION:: A better understanding of dynamic characteristics of the feet can help tune the feet to the user's requirements in promoting a better gait performance.
CLINICAL RELEVANCE: The dynamic data determined from this study are needed to better inform the amputees in predicting the natural frequency of the foot prescribed. The amputees can intuitively tune the cyclic body rhythm during walking or running to match with the natural frequency. This could eventually promote a better gait performance.
BACKGROUND: Prosthesis should be donned and doffed few times during the day and night; thus, it is important to measure ease of donning and doffing.
STUDY DESIGN: A cross-sectional study.
METHODS: The questionnaire was designed and evaluated by a group of experts. The final questionnaire was administered to 50 individuals with trans-tibial amputation. A test-retest study was also conducted on 20 amputees to assess the repeatability of questionnaire items.
RESULTS: The prosthesis donning and doffing questionnaire was developed and tested through a pilot study. Based on Kappa index, the questionnaire items showed correlation coefficients greater than 0.7, which indicate good reliability and repeatability. The majority of the participants had good hand dexterity (80%) and could perform all types of grasps. The mean satisfaction scores with donning and doffing were 69.9 and 81.4, respectively. Most of the respondents needed to don and doff the prosthesis 3.44 times per day. Based on a 7-point score, the total scores ranged between 3 and 7.
CONCLUSION: The prosthesis donning and doffing questionnaire items showed good psychometric properties. A scoring method was suggested based on the pilot sample, which requires further evaluation to be able to differentiate between more suspension types. A larger international multicenter evaluation is required in the future to measure the responsiveness of the scales. This questionnaire will be useful in the evaluation of the ability of amputees to don and doff a trans-tibial limb prosthesis. Clinical relevance Donning and doffing of prostheses are challenging tasks for many lower limb amputees. The prosthesis donning and doffing questionnaire, on its own or combined with other prosthetic evaluation questionnaires, has the potential to help manufacturers, clinicians, and researchers gain knowledge and improve the donning and doffing qualities of prostheses.
Material and Methods: A case-control study of patients who had undergone TTA from 2015 to 2018 was conducted in Raja Isteri Pengiran Anak Saleha Hospital (RIPAS). Complete data was available for 30 subjects and it was compared with 30 diabetic, non-amputee patients matched for age and gender. QoL was assessed using the RAND 36-Item Health Survey (SF-36) and the functional outcome of prosthesis-fitted transtibial amputees was assessed using the Houghton Scale.
Results: Almost all cases of TTA were a result of vascular problems related to diabetes and chronic renal disease (n=29; 97%). Eighteen (60%) participants were fitted with prosthesis and 15 (50%) reported having phantom pain. QoL of participants was found to be significantly lower than that of age and sex-matched diabetic non-amputees with regards to physical functioning, role limitation due to physical health, emotional well-being, social functioning, and bodily pain. The mean Houghton Score for participants fitted with prosthesis was 4.89 (SD= 2.83) suggesting low functional outcome.
Conclusion: TTA has a negative impact on the QoL of patients, especially in terms of functionality. The availability of prosthesis does not significantly improve the quality of life except in the physical functioning domain. Emotional well-being should be emphasised more in the rehabilitation process as this study found poor emotional well-being among participants.