Displaying publications 61 - 80 of 94 in total

Abstract:
Sort:
  1. Sharip NS, Ariffin H, Yasim-Anuar TAT, Andou Y, Shirosaki Y, Jawaid M, et al.
    Polymers (Basel), 2021 Jan 27;13(3).
    PMID: 33513876 DOI: 10.3390/polym13030404
    The major hurdle in melt-processing of ultra-high molecular weight polyethylene (UHMWPE) nanocomposite lies on the high melt viscosity of the UHMWPE, which may contribute to poor dispersion and distribution of the nanofiller. In this study, UHMWPE/cellulose nanofiber (UHMWPE/CNF) bionanocomposites were prepared by two different blending methods: (i) melt blending at 150 °C in a triple screw kneading extruder, and (ii) non-melt blending by ethanol mixing at room temperature. Results showed that melt-processing of UHMWPE without CNF (MB-UHMWPE/0) exhibited an increment in yield strength and Young's modulus by 15% and 25%, respectively, compared to the Neat-UHMWPE. Tensile strength was however reduced by almost half. Ethanol mixed sample without CNF (EM-UHMWPE/0) on the other hand showed slight decrement in all mechanical properties tested. At 0.5% CNF inclusion, the mechanical properties of melt-blended bionanocomposites (MB-UHMWPE/0.5) were improved as compared to Neat-UHMWPE. It was also found that the yield strength, elongation at break, Young's modulus, toughness and crystallinity of MB-UHMWPE/0.5 were higher by 28%, 61%, 47%, 45% and 11%, respectively, as compared to the ethanol mixing sample (EM-UHMWPE/0.5). Despite the reduction in tensile strength of MB-UHMWPE/0.5, the value i.e., 28.4 ± 1.0 MPa surpassed the minimum requirement of standard specification for fabricated UHMWPE in surgical implant application. Overall, melt-blending processing is more suitable for the preparation of UHMWPE/CNF bionanocomposites as exhibited by their characteristics presented herein. A better mechanical interlocking between UHMWPE and CNF at high temperature mixing with kneading was evident through FE-SEM observation, explains the higher mechanical properties of MB-UHMWPE/0.5 as compared to EM-UHMWPE/0.5.
    Matched MeSH terms: Bone Screws
  2. Razak KAA, Ghani KHA, Musa AA
    Injury, 2021 Jan;52(1):90-94.
    PMID: 33168201 DOI: 10.1016/j.injury.2020.11.004
    BACKGROUND: Acetabular fractures in childhood are rare and the literature is scarce to describe a standard protocol in surgical management of these injuries. As the patient is still growing, it warrants a detailed assessment with a sound surgical plan if operative intervention is deemed necessary to prevent late complications. Throughout literature, most fixation rely on using pins, screws, plates or combination of the three which require large surgical exposure and risk of secondary physeal injury, hence we come up with a method of using the Titanium Elastic Nail System (TENS) to overcome this issue. We describe a novel technique in managing acetabular fractures in this group of patients using the TENS.

    METHOD: An 8 year old girl with a diagnosis of right anterior column posterior hemitransverse acetabular fracture was fixed with 3 TENS for supra-acetabular, anterior column and posterior column fragments. Surgery was performed in a minimally invasive manner. No drilling was performed during the surgery and implant insertion is done manually.

    RESULTS: Advantages of this procedure include minimally invasive surgery with smaller wounds, minimal intraoperative bleeding and theoretically reduces the risk of premature fusion of the triradiate cartilage. Patient is allowed early rehabilitation with this method.

    CONCLUSION: This novel method provides an alternative to traditional usage of wires, pins, plates and screws as is described in most literature. However, it requires the surgeon to appreciate that the safe corridors for the implant are much narrower than adults. We recommend this technique for fractures that are deemed suitable for intramedullary fixation and further research in the future will be needed.

    Matched MeSH terms: Bone Screws
  3. Ayob KA, Merican AM, Sulaiman SH, Hariz Ramli AR
    Jt Dis Relat Surg, 2021;32(1):239-244.
    PMID: 33463444 DOI: 10.5606/ehc.2021.77862
    Injuries to the pelvic vasculature during total hip arthroplasties are rare but have serious consequence. They demand urgent and early identification so that appropriate treatment can be instituted. If the bleeding is severe, cardiovascular compromise occurs intraoperatively and this will alert the surgeon of this possibility during acetabular screw placement. Alternatively, a delay in diagnosis can occur because the bleeding and the injured vessel are in the pelvic cavity and not visualized during the surgery. In this article, we report two cases from our center occurring within a six-month interval that sustained a vascular injury during acetabular drilling for screw placement for cementless cup fixation. Each case had a different vessel injury and different lessons can be learned from these rare injuries. The first case had an injury of the inferior gluteal artery following a breach of the sciatic notch. The vessel was treated with percutaneous embolization. The second case demonstrated a venous injury, following a medial protrusio technique for congenital hip dysplasia and a short anterosuperior screw, transecting the external iliac vein. This was subsequently repaired using an endovascular technique. We conclude the reasons for these vessel injuries after analyzing advanced imaging, discuss measures to avoid vessel injury and detail the minimally invasive method for their treatment.
    Matched MeSH terms: Bone Screws
  4. Kapil-Mani KC, Acharya P, Arun S
    Malays Orthop J, 2018 Mar;12(1):15-20.
    PMID: 29725507 DOI: 10.5704/MOJ.1803.003
    Introduction: Various treatment modalities are available but no consensus has been reached for optimal treatment of lateral third clavicle fractures. Precontoured locking plates with broad lateral end for multiple screws fixation is a newly designed plate for lateral third clavicle fractures. The objective of our study was to analyse the functional outcomes as well as complications of this technique in a significant number of cases with long follow-up duration. Materials and Methods: Forty-six patients with distal third clavicle fractures were treated by precontoured clavicular locking plate with broad lateral end. Functional outcomes were assessed on the basis of Constant-Murley Shoulder Outcome Score and University of California, Los Angeles (UCLA) Shoulder Rating Score, active shoulder range of motion, time for fracture union and coraco-clavicular distance. Results: The mean Constant-Murley score was 92.56±4.47 (range: 79-98) for injured side and 96.22±2.23 (range: 90-100) for normal side with p-Value 0.56. Mean coraco-clavicular distance at final follow-up was 10.52±1.13 mm (range 9.7 to 11.7 mm) in injured side and 10.25±0.98 mm (range 9.6 to 11.2 mm) in normal side. Mean UCLA Shoulder Rating Score was 32.55±2.12 (range: 27-34) for injured side and 33.46±1.88 (range: 31- 35) on normal side with p value 0.58. No major complications that necessitated revision of surgery occurred in our study. Conclusion: This newly designed plate seemed extremely useful in successful union of lateral third clavicle fractures, with reduced rate of complications like fixation failures, iatrogenic rotator cuff injury, AC joint osteoarthritis and sub-acromial bursitis, with good functional outcomes.
    Matched MeSH terms: Bone Screws
  5. Bulut G, Colak I, Mik G, Kilic Z, Tasdemir Z
    Malays Orthop J, 2018 Jul;12(2):47-51.
    PMID: 30112129 DOI: 10.5704/MOJ.1807.009
    An 18-year old male patient, with a history of paragliding accident, sustaining a coronal shear fracture of the body of the talus, an anterior process fracture of the calcaneus extending to the calcaneocuboid joint and a nondisplaced navicular body fracture at the right foot and a displaced fracture of the navicular body accompanied with posteromedial process fracture of the talus at the left side was referred to our emergency clinic. For the right foot, the coronal plane fracture of the talar body was anatomically reduced and fixed with screws. For the left foot, screw fixation was performed through the lateral aspect to fix the large posteromedial fragment. Small bone fragments were removed from the left navicular fracture, and the main fragments were also fixed with screw. The talo-navicular joint was stabilised with a Kirschner wire. At 36 months follow-up, bilateral foot and ankle functions were satisfactory, Maryland scores of the right and left foot were 85 (good) and 90 (excellent), respectively, and the patient regained his full activity level by the 5th month postoperatively. With reference to the number and types of fractures in this one patient, we present a standard protocol for treatment of isolated talus, navicular and calcaneal fractures presenting together in a single foot injury.
    Matched MeSH terms: Bone Screws
  6. Dayangku Intan Munthoub, Wan Aizan Wan Abdul Rahman
    Sains Malaysiana, 2011;40:1179-1186.
    Natural organic and abundant resources biopolymers received more attention due to their low cost, availability and degradability after usage. Cassava skin was used as natural fillers to the polyvinyl alcohol (PVA). Cassava skin/poly vinyl alcohol blends were compounded using melt extrusion twin screw extruder and test samples were prepared using the compression method. Various ratios of cassava skin and glycerol were investigated to identify suitable composition based on the water absorption and tensile properties. The water absorption of the cassava skins/PVA samples increased at higher composition of cassava skin due to their hydrophilic properties but decrease with glycerol content. The strength of the cassava skins/PVA samples increased with the higher composition of cassava skin up to 70 wt% while gradually decreased with the increasing composition of glycerol. The Young modulus increased with glycerol content but decreased with fibre loading up to 70 wt%. Elongation at break decreased with fibre loading and glycerol up to 70 wt% and 30 phr, respectively.
    Matched MeSH terms: Bone Screws
  7. Noia G, Silluzio N, Sircana G, Maccauro G, Ziranu A
    Malays Orthop J, 2019 Nov;13(3):80-84.
    PMID: 31890117 DOI: 10.5704/MOJ.1911.015
    Bilateral fracture-dislocation of the talus is a rare occurrence. It represents 0.06% of the dislocations and 2% of the traumas of the talus. We report the case of a 29-year-old patient with an exposed bilateral fracture of the talus following a plane accident. On the right ankle, the patient had a fracture-dislocation Hawkin 3 Gustilo II, on the left ankle presented a Hawkin 4 Gustilo IIIB. The patient was treated within six hours from the trauma. We reduced the dislocation and performed an osteotomy of the tibial malleolus and osteosynthesis of the fracture with screws. The definitive stabilisation has been achieved in both limbs with an external fixator. We evaluated the patient at 1, 3, 6, 8, 12 and 18 months from treatment, with a radiograph and with SF-36 and Foot and Ankle Disability Index questionnaires. No infection was reported, radiographs showed a successful consolidation of the fracture in both limbs. At the one year follow-up, the patient was able to walk without aids and there were no signs of osteonecrosis on the MRI. The treatment of these lesions requires timely treatment, an anatomical reduction of the fracture and patient's collaboration. The use of external fixator with internal osteosynthesis represents a good therapeutic option in Hawkins 3 and 4 type fractures.
    Matched MeSH terms: Bone Screws
  8. Beng TB, Kotani Y, Sia U, Gonchar I
    Asian Spine J, 2019 10;13(5):809-814.
    PMID: 31154702 DOI: 10.31616/asj.2018.0283
    Study Design: Retrospective clinical study on the indirect decompressive effect of oblique lateral interbody fusion (OLIF) for adult spinal deformity.

    Purpose: To evaluate the effect of interbody distraction by OLIF for the treatment of adult spinal deformity.

    Overview of Literature: Adult spinal deformity with symptomatic stenosis has been addressed conventionally using a direct posterior decompression approach with fusion. However, stenotic symptoms can also be alleviated indirectly through restoration of intervertebral and foraminal heights and correction of spinal alignment.

    Methods: Twenty-eight patients with adult spinal deformity underwent OLIF combined with modified cortical bone trajectory screws at 94 lumbar levels with neuromonitoring. The patients were divided into three groups based on their preoperative lumbar lordosis: group A, <0°; group B, 0°-20°; and group C, >20°. The cross-sectional area (CSA) of the thecal sac was measured preoperatively and postoperatively on axial magnetic resonance images. Differences in CSA were evaluated, and the relationship between the CSA extension ratio and preoperative CSA was assessed. Changes in disc height and segmental disc angle were measured from plain radiographs.

    Results: OLIFs were performed successfully without neural complications. In group A, the mean CSA increased from 120.6 mm2 preoperatively to 148.5 mm2 postoperatively (p <0.001). The mean CSA for group B increased from 120.1 mm2 preoperatively to 154.4 mm2 postoperatively (p <0.001). Group C had an increase in mean CSA from 114.7 mm2 preoperatively to 160.7 mm2 postoperatively (p <0.001). The mean CSA enlargement ratio was 27.5%, 32.1%, and 60.4% in groups A, B, and C, respectively. The mean CSA extension ratio was inversely correlated with preoperative CSA.

    Conclusions: The effect of indirect neural decompression in adult spinal deformity with OLIF varies with the degree of preoperative lumbar lordosis.

    Matched MeSH terms: Bone Screws
  9. Tamburrelli FC, Perna A, Proietti L, Zirio G, Santagada DA, Genitiempo M
    Malays Orthop J, 2019 Nov;13(3):39-44.
    PMID: 31890109 DOI: 10.5704/MOJ.1911.007
    Introduction: Posterior percutaneous instrumentation may represent a challenge when multiple levels need to be instrumentated, especially when including the upper thoracic spine. The aim of the present study was to evaluate the technical feasibility and the long-term outcome of such long constructs in different surgical conditions. Materials and Methods: This investigation was a retrospective cohort study which included patients who underwent thoraco-lumbar percutaneous fixations. We collected clinical, surgical and radiological data, with a minimum follow-up of 24 months. Health-related quality-of-life, residual pain, instrumentation placement, and complications were studied. Results: A total of 18 procedures were enrolled, in which 182 screws were implanted, (170 positioned in thoracic and 12 in lumbar pedicles, respectively). No surgical complications or hardware failure occurred in our series, 6 out of 182 (3,2%) screws had a partial pedicle breach, without neurological impairment or need for surgical revision. Conclusion: According to our results, a fully posterior percutaneous approach for long thoraco-lumbar spine instrumentation can be considered safe and reproducible, although an adequate training is strictly required.
    Matched MeSH terms: Bone Screws
  10. Kamar Affendi NH, Ahmad R, Tong Wah L, Abdul Hamid NF, Abdul Hakim AY
    Dent Med Probl, 2024;61(2):257-268.
    PMID: 38686968 DOI: 10.17219/dmp/155811
    BACKGROUND: The screw-retrievable cement-retained (SRCR) design combines the benefits of both screwand cement-retained implant-supported restorations. This concept has sparked interest in implant dentistry. However, there is a lack of research on fracture behaviors and clinical performance of such restorations.

    OBJECTIVES: The aim of the present article was to review the current literature on the fracture loads and fracture modes of SRCR implant restorations - in vitro studies, and also studies demonstrating the clinical performance of such design.

    MATERIAL AND METHODS: A literature search was conducted from January 2000 to June 2022, using 6 databases to identify studies on fracture load and clinical performance that fulfilled the eligibility criteria. Thirty-eight studies met the inclusion criteria (22 in vitro and16 in vivo). The in vivo studies comprised case reports/series/letters (9), clinical techniques (2), retrospective/prospective studies (3), and randomized controlled trials (RCTs) (2).

    RESULTS: The reviewed articles reported the effects of the SRCR design on the fracture risk if screw access channels were filled or unfilled, with regard to their diameter, and the preparation before or after glazing. The effect of the type of material used in the construction on the fracture modes SRCR restorations was also reported. The long-term clinical data was mainly retrospective and referred to metal-ceramic constructions. Limited long-term clinical data was available for all-ceramic materials and high-performance polymers (HPPs).

    CONCLUSIONS: Screw-retrievable cement-retained implant restorations appear to have potential in the monolithic design. If the SRCR construction is metal-ceramic or made of a veneered material, special design and abutment selection should be considered. High-performance polymers may be recommended as a substitute for posterior implant restoration.

    Matched MeSH terms: Bone Screws
  11. Yusof MI, Ming LK, Abdullah MS
    J Orthop Surg (Hong Kong), 2007 Aug;15(2):187-90.
    PMID: 17709859
    To measure the cervical pedicles and assess the feasibility of transpedicular fixation in a Malay population.
    Matched MeSH terms: Bone Screws*
  12. Yusof MI, Yusof AH, Abdullah MS, Hussin TM
    J Orthop Surg (Hong Kong), 2007 Apr;15(1):67-72.
    PMID: 17429121
    To measure the diameter of the odontoid process in a Malaysian population using computed tomographic (CT) scan and determine the feasibility of treating type-II odontoid fractures using 2 cortical screws.
    Matched MeSH terms: Bone Screws*
  13. Wong TS, Abdul Rashid ML, Hasan MS, Chiu CK, Chan CYW, Kwan MK
    J Orthop Surg (Hong Kong), 2019 4 9;27(2):2309499019840763.
    PMID: 30955474 DOI: 10.1177/2309499019840763
    The presence of anatomical anomalies such as absence of C1 posterior arch and presence of C2 high-riding vertebral artery may not allow a conventional C1-C2 fusion, and this patient will require occipitocervical fusion. A 62-year-old lady presented with cervical myelopathy. CT scan demonstrated an os odontoideum with C1-C2 dislocation. The posterior arch of atlas on right C1 vertebra was absent, and there was high-riding vertebral artery on left C2. MRI revealed severe cord compression with cord oedema. The chronic atlantoaxial dislocation was reduced successfully with skeletal traction. Hybrid C1-C2 fusion augmented with autogenous local bone graft with corticocancellous iliac crest bone graft was performed to avoid an unnecessary occipitocervical fusion. She was stable throughout surgery and discharged 6 days later. CT scan 6 months post-operation showed a solid posterior fusion mass. Hybrid C1-C2 fusion can be performed to avoid occipitocervical fusion despite presence of abnormal anatomy at C1 and C2 vertebrae.
    Matched MeSH terms: Bone Screws*
  14. Labens R, Khairuddin NH, Murray M, Jermyn K, Ahmad RS
    Vet Surg, 2019 Jan;48(1):96-104.
    PMID: 30403407 DOI: 10.1111/vsu.13123
    OBJECTIVE: To assess fracture gap reduction and stability of linear vs triangular 4.5-mm lag screw repair of experimental, uniarticular, and complete forelimb proximal phalanx (P1) fractures.

    STUDY DESIGN: Experimental.

    SAMPLE POPULATION: Fourteen equine cadaver limbs/horses.

    METHODS: Simulated fractures were repaired with 2 lag screws under 4-Nm insertion torque (linear repair). Computed tomography (CT) imaging was performed with the leg unloaded and loaded to forces generated while walking. The fracture repair was revised to include 3 lag screws placed with the same insertion torque (triangular repair) prior to CT. The width of the fracture gap was assessed qualitatively by 2 observers and graded on the basis of gap measurements relative to the average voxel size at dorsal, mid, and palmar P1 sites. Interobserver agreement was assessed with Cohen's κ. The effect of repair type, loading condition, and measurement site on fracture gap grades was evaluated by using Kendall's τ-b correlation coefficients and paired nonparametric tests. Significance was set at P ≤ .05.

    RESULTS: Agreement between loading and fracture gap widening was fair in triangular (κ = 0.53) and excellent in linear (κ = 0.81) repairs. Loading resulted in fracture gap distraction in linear repairs (Plinear  = .008). Triangular repairs reduced fractures better irrespective of loading (Punloaded  = .003; Ploaded  

    Matched MeSH terms: Bone Screws/veterinary
  15. Chang KC, Samartzis D, Fuego SM, Dhatt SS, Wong YW, Cheung WY, et al.
    Bone Joint J, 2013 Jul;95-B(7):972-6.
    PMID: 23814252 DOI: 10.1302/0301-620X.95B7.30598
    Transarticular screw fixation with autograft is an established procedure for the surgical treatment of atlantoaxial instability. Removal of the posterior arch of C1 may affect the rate of fusion. This study assessed the rate of atlantoaxial fusion using transarticular screws with or without removal of the posterior arch of C1. We reviewed 30 consecutive patients who underwent atlantoaxial fusion with a minimum follow-up of two years. In 25 patients (group A) the posterior arch of C1 was not excised (group A) and in five it was (group B). Fusion was assessed on static and dynamic radiographs. In selected patients CT imaging was also used to assess fusion and the position of the screws. There were 15 men and 15 women with a mean age of 51.2 years (23 to 77) and a mean follow-up of 7.7 years (2 to 11.6). Stable union with a solid fusion or a stable fibrous union was achieved in 29 patients (97%). In Group A, 20 patients (80%) achieved a solid fusion, four (16%) a stable fibrous union and one (4%) a nonunion. In Group B, stable union was achieved in all patients, three having a solid fusion and two a stable fibrous union. There was no statistically significant difference between the status of fusion in the two groups. Complications were noted in 12 patients (40%); these were mainly related to the screws, and included malpositioning and breakage. The presence of an intact or removed posterior arch of C1 did not affect the rate of fusion in patients with atlantoaxial instability undergoing C1/C2 fusion using transarticular screws and autograft.
    Matched MeSH terms: Bone Screws/adverse effects*
  16. Alizadeh M, Kadir MR, Fadhli MM, Fallahiarezoodar A, Azmi B, Murali MR, et al.
    J Orthop Res, 2013 Sep;31(9):1447-54.
    PMID: 23640802 DOI: 10.1002/jor.22376
    Posterior instrumentation is a common fixation method used to treat thoracolumbar burst fractures. However, the role of different cross-link configurations in improving fixation stability in these fractures has not been established. A 3D finite element model of T11-L3 was used to investigate the biomechanical behavior of short (2 level) and long (4 level) segmental spine pedicle screw fixation with various cross-links to treat a hypothetical L1 vertebra burst fracture. Three types of cross-link configurations with an applied moment of 7.5 Nm and 200 N axial force were evaluated. The long construct was stiffer than the short construct irrespective of whether the cross-links were used (p < 0.05). The short constructs showed no significant differences between the cross-link configurations. The XL cross-link provided the highest stiffness and was 14.9% stiffer than the one without a cross-link. The long construct resulted in reduced stress to the adjacent vertebral bodies and screw necks, with 66.7% reduction in bending stress on L2 when the XL cross-link was used. Thus, the stability for L1 burst fracture fixation was best achieved by using long segmental posterior instrumentation constructs and an XL cross-link configuration. Cross-links did not improved stability when a short structure was used.
    Matched MeSH terms: Bone Screws*
  17. Lee CK, Tan TS, Chan C, Kwan MK
    J Orthop Surg (Hong Kong), 2017 01;25(1):2309499017692683.
    PMID: 28211302 DOI: 10.1177/2309499017692683
    INTRODUCTION: C1 lateral mass (C1LM) screw is a common procedure in spine surgery. However, related studies are lacking in Asia. We aim to determine the safety of C1LM screw for the Chinese, Indians, and Malays.

    METHODS: Three-dimensional computed tomographies of 180 subjects (60 from each ethnic) were analyzed. The length and angulations of C1LM screw and the location of internal carotid artery (ICA) in relation to C1LM were assessed and classified according to the classification by Murakami et al. The incidence of ponticulus posticus (PP) was determined and the differences among the population of these three ethnics were recorded.

    RESULTS: The average base length was 8.5 ± 1.4 mm. The lengths within the lateral mass were between 14.7 ± 1.6 mm and 21.7 ± 2.3 mm. The prevalence of PP was 8.3%. 55.3% (199) of ICA were located in zone 0, 38.3% (138) in zone 1-1, 6.4% (23) in zone 1-2, and none in zone 1-3 and zone 2. The average angulation from the entry point to the ICA was 8.5° ± 6.4° laterally. The mean distance of ICA from C1 anterior cortex was 3.7 ± 1.7 mm (range: 0.6∼11.3). There was no difference in distribution of ICA in zone 1 among the three population (Chinese-47%, Indians-61%, and Malays-53%; p > 0.05).

    CONCLUSIONS: No ICA is located medial to the entry point of C1LM screw. If bicortical purchase of C1LM screw is needed, screw protrusion of less than 3 mm or medially angulated is safe for ICA. The incidence of PP is 8.3% with higher prevalence among the Indian population.

    Matched MeSH terms: Bone Screws*
  18. Alhalawani AM, Towler MR
    J Biomater Appl, 2013 Nov;28(4):483-97.
    PMID: 23812580 DOI: 10.1177/0885328213495426
    Sternotomy and sternal closure occur prior to and post cardiac surgery, respectively. Although post-operative complications associated with poor sternal fixation can result in morbidity, mortality, and considerable resource utilization, sternotomy is preferred over other methods such as lateral thoracotomy. Rigid sternal fixation is associated with stability and reduced incidence of post-operative complications. This is a comprehensive review of the literature evaluating in vivo, in vitro, and clinical responses to applying commercial and experimental surgical tools for sternal fixation after median sternotomy. Wiring, interlocking, plate-screw, and cementation techniques have been examined for closure, but none have experienced widespread adoption. Although all techniques have their advantages, serious post-operative complications were associated with the use of wiring and/or plating techniques in high-risk patients. A fraction of studies have analyzed the use of sternal interlocking systems and only a single study analyzed the effect of using kryptonite cement with wires. Plating and interlocking techniques are superior to wiring in terms of stability and reduced rate of post-operative complications; however, further clinical studies and long-term follow-up are required. The ideal sternal closure should ensure stability, reduced rate of post-operative complications, and a short hospitalization period, alongside cost-effectiveness.
    Matched MeSH terms: Bone Screws
  19. Chua YP, Kwan MK, Saw A
    Med J Malaysia, 2005 Jul;60 Suppl C:78-82.
    PMID: 16381289
    The need for perioperative blood transfusion in elderly patients with trochanteric fracture scheduled for elective dynamic hip screw fixation has recently been questioned following reports on the association between allogeneic blood transfusion and post-operative infections. This retrospective study was undertaken to assess the amount of per operative blood loss and transfusion requirement in relation to pre-operative haemoglobin level in 198 patients with trochanteric fractures. The average per operative blood loss was 409 ml and it correlated well with the duration of the operation. More than half of the patients (52.5%) required blood transfusion and nearly three-quarters were anaemic prior to the surgery. Proactive pre-operative measures to optimize the patient's haemoglobin level and intra-operative minimization of blood loss are essential steps to obviate the need for perioperative allogeneic blood transfusion.
    Matched MeSH terms: Bone Screws
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links