Displaying publications 61 - 72 of 72 in total

Abstract:
Sort:
  1. Fraga MV, Stoller JZ, Glau CL, De Luca D, Rempell RG, Wenger JL, et al.
    Pediatrics, 2019 11;144(5).
    PMID: 31615954 DOI: 10.1542/peds.2019-1401
    Point-of-care ultrasound is currently widely used across the landscape of pediatric care. Ultrasound machines are now smaller, are easier to use, and have much improved image quality. They have become common in emergency departments, ICUs, inpatient wards, and outpatient clinics. Recent growth of supportive evidence makes a strong case for using point-of-care ultrasound for pediatric interventions such as vascular access (in particular, central-line placement), lumbar puncture, fluid drainage (paracentesis, thoracentesis, pericardiocentesis), suprapubic aspiration, and soft tissue incision and drainage. Our review of this evidence reveals that point-of-care ultrasound has become a powerful tool for improving procedural success and patient safety. Pediatric patients and clinicians performing procedures stand to benefit greatly from point-of-care ultrasound, because seeing is believing.
    Matched MeSH terms: Point-of-Care Systems*
  2. Citartan M
    Talanta, 2021 Sep 01;232:122436.
    PMID: 34074421 DOI: 10.1016/j.talanta.2021.122436
    Dot blot assays have always been associated with antibodies as the main molecular recognition element, which are widely employed in a myriad of diagnostic applications. With the rising of aptamers as the equivalent molecular recognition elements of antibodies, dot blot assays are also one of the diagnostic avenues that should be scrutinized for their amenability with aptamers as the potential surrogates of antibodies. In this review, the stepwise procedures of an aptamer-based dot blot assays are underscored before reviewing the existing aptamer-based dot blot assays developed so far. Most of the applications center on monitoring the progress of SELEX and as the validatory assays to assess the potency of aptamer candidates. For the purpose of diagnostics, the current effort is still languid and as such possible suggestions to galvanize the move to spur the aptamer-based dot blot assays to a point-of-care arena are discussed.
    Matched MeSH terms: Point-of-Care Systems
  3. Zainol Abidin AS, Rahim RA, Md Arshad MK, Fatin Nabilah MF, Voon CH, Tang TH, et al.
    Sensors (Basel), 2017 May 22;17(5).
    PMID: 28531146 DOI: 10.3390/s17051180
    Anxiety is a psychological problem that often emerges during the normal course of human life. The detection of anxiety often involves a physical exam and a self-reporting questionnaire. However, these approaches have limitations, as the data might lack reliability and consistency upon application to the same population over time. Furthermore, there might be varying understanding and interpretations of the particular question by the participant, which necessitating the approach of using biomarker-based measurement for stress diagnosis. The most prominent biomarker related to stress, hormone cortisol, plays a key role in the fight-or-flight situation, alters the immune response, and suppresses the digestive and the reproductive systems. We have taken the endeavour to review the available aptamer-based biosensor (aptasensor) for cortisol detection. The potential point-of-care diagnostic strategies that could be harnessed for the aptasensing of cortisol were also envisaged.
    Matched MeSH terms: Point-of-Care Systems*
  4. Singh S, Numan A, Cinti S
    Anal Chem, 2022 Jan 11;94(1):26-40.
    PMID: 34802244 DOI: 10.1021/acs.analchem.1c03856
    Matched MeSH terms: Point-of-Care Systems
  5. Lai AKH, Noor Azhar AMB, Bustam AB, Tiong XT, Chan HC, Ahmad RB, et al.
    BMC Med Educ, 2020 Aug 12;20(1):263.
    PMID: 32787921 DOI: 10.1186/s12909-020-02173-7
    BACKGROUND: Although gamification increases user engagement, its effectiveness in point-of-care ultrasonographic training has yet to be fully established. This study was conducted with the primary outcome of evaluating its effectiveness in point-of-care ultrasonographic training as compared to conventional approach.

    METHODS: Participants consisting of junior doctors were randomized into either the (1) gamified or the (2) conventional educational approach for ultrasonographic training.

    RESULTS: A total of 31 junior doctors participated in this study (16 participants in gamified arm, 15 in the conventional arm after one participant from the conventional arm dropped out due to work commitment). Two-way mixed ANOVA test showed that there was no statistically significant interaction between the types of educational approach and time of testing (pre-test, post-test, 2 months post-training) for both theoretical knowledge score and practical skills score, with F(2, 58) = 39.6, p point-of-care ultrasonographic training.

    Matched MeSH terms: Point-of-Care Systems*
  6. Warrener L, Slibinskas R, Chua KB, Nigatu W, Brown KE, Sasnauskas K, et al.
    Bull World Health Organ, 2011 Sep 01;89(9):675-82.
    PMID: 21897488 DOI: 10.2471/BLT.11.088427
    OBJECTIVE: To evaluate the performance of a newly developed point-of-care test (POCT) for the detection of measles-specific IgM antibodies in serum and oral fluid specimens and to assess if measles virus nucleic acid could be recovered from used POCT strips.

    METHODS: The POCT was used to test 170 serum specimens collected through measles surveillance or vaccination programmes in Ethiopia, Malaysia and the Russian Federation: 69 were positive for measles immunoglobulin M (IgM) antibodies, 74 were positive for rubella IgM antibodies and 7 were positive for both. Also tested were 282 oral fluid specimens from the measles, mumps and rubella (MMR) surveillance programme of the United Kingdom of Great Britain and Northern Ireland. The Microimmune measles IgM capture enzyme immunoassay was the gold standard for comparison. A panel of 24 oral fluids was used to investigate if measles virus haemagglutinin (H) and nucleocapsid (N) genes could be amplified by polymerase chain reaction directly from used POCT strips.

    FINDINGS: With serum POCT showed a sensitivity and specificity of 90.8% (69/76) and 93.6% (88/94), respectively; with oral fluids, sensitivity and specificity were 90.0% (63/70) and 96.2% (200/208), respectively. Both H and N genes were reliably detected in POCT strips and the N genes could be sequenced for genotyping. Measles virus genes could be recovered from POCT strips after storage for 5 weeks at 20-25 °C.

    CONCLUSION: The POCT has the sensitivity and specificity required of a field-based test for measles diagnosis. However, its role in global measles control programmes requires further evaluation.

    Matched MeSH terms: Point-of-Care Systems/standards*
  7. Nanthasurasak P, See HH, Zhang M, Guijt RM, Breadmore MC
    Angew Chem Int Ed Engl, 2019 03 18;58(12):3790-3794.
    PMID: 30614157 DOI: 10.1002/anie.201812077
    An electrokinetic platform was developed for extracting small-molecule pharmaceuticals from a dried blood spot. Through the exclusion of liquid reagents and use of low field strength (6 V cm-1 ), the electroextraction of a drug from a dried blood spot, deposited on a polymer inclusion membrane (PIM), could be realised while in transit in the mail. In transit sample preparation provides a potential solution to in situ sample degradation and may accelerate the workflow upon arrival of a patient sample at the analytical facility. The electroextraction method was enabled through our discovery of the use of 15-20 μm thin PIMs as electrophoretic separation medium in absence of liquid reagents. Here, a PIM consisting of cellulose triacetate as polymer base, 2-nitrophenyl octyl ether as plasticizer and 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide as carrier was used. The PIM, was packaged with two 12 V batteries to supply the separation voltage. A blood spot containing berberine chloride was deposited and dried before the applying the separation potential, allowing for the electroextraction while the packaged device was shipped in internal mail. Upon arrival in the analytical laboratory, the PIM was analysed using a fluorescence microscope with photon multiplier tube, quantifying the berberine extracted away from the sample matrix. This platform represents a new opportunity for processing clinical samples during transport to the laboratory, saving time and manual handling to accelerate the time to result.
    Matched MeSH terms: Point-of-Care Systems
  8. Swathirajan CR, Vignesh R, Boobalan J, Solomon SS, Saravanan S, Balakrishnan P
    J Med Microbiol, 2017 Oct;66(10):1379-1382.
    PMID: 28901908 DOI: 10.1099/jmm.0.000514
    BACKGROUND: Sustainable suppression of HIV replication forms the basis of anti-retroviral therapy (ART) medication. Thus, reliable quantification of HIV viral load has become an essential factor to monitor the effectiveness of the ART. Longer turnaround-time (TAT), batch testing and technical skills are major drawbacks of standard real-time PCR assays.

    METHODS: The performance of the point-of-care Xpert HIV-1 viral load assay was evaluated against the Abbott RealTime PCR m2000rt system. A total of 96 plasma specimens ranging from 2.5 log10 copies ml-1 to 4.99 log10 copies ml-1 and proficiency testing panel specimens were used. Precision and accuracy were checked using the Pearson correlation co-efficient test and Bland-Altman analysis.

    RESULTS: Compared to the Abbott RealTime PCR, the Xpert HIV-1 viral load assay showed a good correlation (Pearson r=0.81; P<0.0001) with a mean difference of 0.27 log10 copies ml-1 (95 % CI, -0.41 to 0.96 log10 copies ml-1; sd, 0.35 log10 copies ml-1).

    CONCLUSION: Reliable and ease of testing individual specimens could make the Xpert HIV-1 viral load assay an efficient alternative method for ART monitoring in clinical management of HIV disease in resource-limited settings. The rapid test results (less than 2 h) could help in making an immediate clinical decision, which further strengthens patient care.

    Matched MeSH terms: Point-of-Care Systems*
  9. Gan RK, Sanchez Martinez A, Abu Hasan MA, Castro Delgado R, Arcos González P
    J Ultrasound, 2023 Jun;26(2):343-353.
    PMID: 36694072 DOI: 10.1007/s40477-022-00761-5
    INTRODUCTION: Necrotizing fasciitis (NF) is a rapidly progressive necrosis of the fascial layer with a high mortality rate. It is a life-threatening medical emergency that requires urgent treatment. Lack of skin finding in NF made diagnosis difficult and required a high clinical index of suspicion. The use of ultrasound may guide clinicians in improving diagnostic speed and accuracy, thus leading to improved management decisions and patient outcomes. This literature search aims to review the use of point-of-care ultrasonography in diagnosing necrotizing fasciitis.

    METHOD: We searched relevant electronic databases, including PUBMED, MEDLINE, and SCOPUS, and performed a systematic review. Keywords used were "necrotizing fasciitis" or "necrotising fasciitis" or "necrotizing soft tissue infections" and "point-of-care ultrasonography" "ultrasonography" or "ultrasound". No temporal limitation was set. An additional search was performed via google scholar, and the top 100 entry was screened.

    RESULTS: Among 540 papers screened, only 21 were related to diagnosing necrotizing fasciitis using ultrasonography. The outcome includes three observational studies, 16 case reports, and two case series, covering the period from 1976 to 2022.

    CONCLUSION: Although the use of ultrasonography in diagnosing NF was published in several papers with promising results, more studies are required to investigate its diagnostic accuracy and potential to reduce time delay before surgical intervention, morbidity, and mortality.

    Matched MeSH terms: Point-of-Care Systems*
  10. Hussain A, Via G, Melniker L, Goffi A, Tavazzi G, Neri L, et al.
    Crit Care, 2020 12 24;24(1):702.
    PMID: 33357240 DOI: 10.1186/s13054-020-03369-5
    COVID-19 has caused great devastation in the past year. Multi-organ point-of-care ultrasound (PoCUS) including lung ultrasound (LUS) and focused cardiac ultrasound (FoCUS) as a clinical adjunct has played a significant role in triaging, diagnosis and medical management of COVID-19 patients. The expert panel from 27 countries and 6 continents with considerable experience of direct application of PoCUS on COVID-19 patients presents evidence-based consensus using GRADE methodology for the quality of evidence and an expedited, modified-Delphi process for the strength of expert consensus. The use of ultrasound is suggested in many clinical situations related to respiratory, cardiovascular and thromboembolic aspects of COVID-19, comparing well with other imaging modalities. The limitations due to insufficient data are highlighted as opportunities for future research.
    Matched MeSH terms: Point-of-Care Systems/standards*
  11. Grigg MJ, William T, Barber BE, Parameswaran U, Bird E, Piera K, et al.
    J Clin Microbiol, 2014 Jun;52(6):2053-60.
    PMID: 24696029 DOI: 10.1128/JCM.00181-14
    Plasmodium knowlesi causes severe and fatal malaria in Malaysia. Microscopic misdiagnosis is common and may delay appropriate treatment. P. knowlesi can cross-react with "species-specific" parasite lactate dehydrogenase (pLDH) monoclonal antibodies used in rapid diagnostic tests (RDTs) to detect P. falciparum and P. vivax. At one tertiary-care hospital and two district hospitals in Sabah, we prospectively evaluated two combination RDTs for malaria diagnosis by using both a pan-Plasmodium-pLDH (pan-pLDH)/P. falciparum-specific-pLDH (Pf-pLDH) RDT (OptiMAL-IT) and a non-P. falciparum VOM-pLDH/Pf-HRP2 RDT (CareStart). Differential cross-reactivity among these combinations was hypothesized to differentiate P. knowlesi from other Plasmodium monoinfections. Among 323 patients with PCR-confirmed P. knowlesi (n = 193), P. falciparum (n = 93), and P. vivax (n = 37) monoinfections, the VOM-pLDH individual component had the highest sensitivity for nonsevere (35%; 95% confidence interval [CI], 27 to 43%) and severe (92%; CI, 81 to 100%) P. knowlesi malaria. CareStart demonstrated a P. knowlesi sensitivity of 42% (CI, 34 to 49%) and specificity of 74% (CI, 65 to 82%), a P. vivax sensitivity of 83% (CI, 66 to 93%) and specificity of 71% (CI, 65 to 76%), and a P. falciparum sensitivity of 97% (CI, 90 to 99%) and specificity of 99% (CI, 97 to 100%). OptiMAL-IT demonstrated a P. knowlesi sensitivity of 32% (CI, 25 to 39%) and specificity of 21% (CI, 15 to 29%), a P. vivax sensitivity of 60% (CI, 42 to 75%) and specificity of 97% (CI, 94 to 99%), and a P. falciparum sensitivity of 82% (CI, 72 to 89%) and specificity of 39% (CI, 33 to 46%). The combination of CareStart plus OptiMAL-IT for P. knowlesi using predefined criteria gave a sensitivity of 25% (CI, 19 to 32%) and specificity of 97% (CI, 92 to 99%). Combining two RDT combinations was highly specific for P. knowlesi malaria diagnosis; however, sensitivity was poor. The specificity of pLDH RDTs was decreased for P. vivax and P. falciparum because of P. knowlesi cross-reactivity and cautions against their use alone in areas where P. knowlesi malaria is endemic. Sensitive P. knowlesi-specific RDTs and/or alternative molecular diagnostic tools are needed in areas where P. knowlesi malaria is endemic.
    Matched MeSH terms: Point-of-Care Systems*
  12. Adi O, Fong CP, Sum KM, Ahmad AH
    Am J Emerg Med, 2021 04;42:263.e1-263.e4.
    PMID: 32994082 DOI: 10.1016/j.ajem.2020.09.011
    Airway assessment is important in emergency airway management. A difficult airway can lead to life-threatening complications. A perfect airway assessment tool does not exist and unanticipated difficulty will remain unforeseen. Current bedside clinical predictors of the difficult airway are unreliable but airway ultrasound can be used as an adjunct to predict difficult laryngoscopy. We report a case of a 60-year-old man presenting to the emergency department with shortness of breath, hoarseness of voice and stridor. Airway ultrasound revealed a large laryngeal mass narrowing the upper airway, extending to bilateral vocal cords with heterogenous echogenicity. In view of impending complete upper airway obstruction, acute respiratory distress and airway ultrasound findings, urgent emergency tracheostomy was chosen as definitive airway over endotracheal intubation or surgical cricothyroidotomy. Point of care ultrasound (POCUS) was used to evaluate this patient with severe upper airway obstruction. A laryngeal mass was detected by ultrasound and this pointed towards the presence of a difficult airway. POCUS was a good non-invasive tool used for airway assessment in this uncooperative and unstable patient. Ultrasound predictors of the difficult airway include the inability to visualize the hyoid bone, short hyomental distance ratio, high pretracheal anterior neck thickness and large tongue size. Besides airway assessment, ultrasound can also help to predict endotracheal tube size, confirm intubation and guide emergency airway procedures such as cricothyroidotomy and tracheostomy. Point of care ultrasound of the upper airway can be used in airway assessment to identify distorted airway anatomy, pathological lesions and guide treatment decisions.
    Matched MeSH terms: Point-of-Care Systems*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links