Displaying publications 81 - 100 of 1711 in total

Abstract:
Sort:
  1. Chan KL, Yuen KH, Jinadasa S, Peh KK, Toh WT
    Planta Med, 1997 Feb;63(1):66-9.
    PMID: 9063097
    A high-performance liquid chromatography assay equipped with a glassy carbon electrode for electrochemical detection (HPLC-ECD) was developed at reductive mode for the analysis of artemisinin, the antimalarial drug from Artemisia annua (Asteraceae) in human plasma. This method was selective, sensitive, and produced satisfactory recovery, precision, and accuracy. Analysis of plasma samples from 8 male volunteers given 10 mg kg-1 of artemisinin orally as an aqueous suspension showed a mean peak plasma concentration (Cmax) of 580.89 ng ml-1 +/- 88.64 SD at 2.5 h +/- 0.5 SD after dosing, and the mean area under the plasma concentration-time curve (AUC0-infinity) was 2227.57 ng h ml-1 +/- 677.22 SD. In addition, the elimination rate constant (Ke), elimination half-life (t1/2), and apparent volume of distribution (Vd) were calculated to be 0.2971 h-1 +/- 0.0644 SD, 2.42 h +/- 0.46 SD, and 16.26 l kg-1 +/- 3.44 SD, respectively.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  2. Jayaraman SD, Ismail S, Nair NK, Navaratnam V
    J Chromatogr B Biomed Sci Appl, 1997 Mar 07;690(1-2):253-7.
    PMID: 9106050
    A method is described for the determination of pyronaridine in plasma using high-performance liquid chromatography with fluorescence detection. The method involves liquid-liquid extraction with phosphate buffer (pH 6.0, 0.05 M) and diethyl ether-hexane (70:30%, v/v) and chromatographic separation on a C18 column (Nucleosil, 250 x 4.6 mm I.D., 5 microns particle size) with acetonitrile-0.05 M phosphate buffer pH 6.0 (60:40%, v/v) as the mobile phase (1 ml/min) and detection by fluorescence (lambda ex = 267 nm, lambda em = 443 nm). The detector response is linear up to 1000 ng and the overall recoveries of pyronaridine and quinine were 90.0 and 60.3%, respectively. The assay procedure was adequately sensitive to measure 10 ng/ml pyronaridine in plasma samples with acceptable precision (< 15% C.V.). The method was found to be suitable for use in clinical pharmacological studies.
    Matched MeSH terms: Chromatography, High Pressure Liquid
  3. Mordi MN, Mansor SM, Navaratnam V, Wernsdorfer WH
    Br J Clin Pharmacol, 1997 Apr;43(4):363-5.
    PMID: 9146847
    AIMS: To determine the pharmacokinetics of artemether (ARM) and its principal active metabolite, dihydroartemisinin (DHA) in healthy volunteers.

    METHODS: Six healthy male Malaysian subjects were given a single oral dose of 200 mg artemether. Blood samples were collected to 72 h. Plasma concentrations of the two compounds were measured simultaneously by reversed-phase h.p.l.c. with electro-chemical detection in the reductive mode.

    RESULTS: Mean (+/- s.d.) maximum concentrations of ARM, 310 +/- 153 micrograms l-1, were reached 1.88 +/- 0.21 h after drug intake. The mean elimination half-life was 2.00 +/- 0.59 h, and the mean AUC 671 +/- 271 micrograms l-1 h. The mean Cmax of DHA, 273 +/- 64 micrograms l-1 was observed at 1.92 +/- 0.13 h. The mean AUC of DHA was 753 +/- 233 micrograms h l-1'. ARM and DHA were stable at < or = -20 degrees C for at least 4 months in plasma samples.

    CONCLUSIONS: The relatively short half-life of ARM may be one of the factors responsible for the poor radical cure rate of falciparum malaria with regimens employing daily dosing. In view of the rapid loss of DHA in plasma samples held at room temperature (26 degrees C) it is recommended to store them at a temperature of < or = -20 degrees C as early as possible after sample collection.

    Matched MeSH terms: Chromatography, High Pressure Liquid
  4. Navaratnam V, Mordi MN, Mansor SM
    J Chromatogr B Biomed Sci Appl, 1997 Apr 25;692(1):157-62.
    PMID: 9187395
    A selective reproducible high-performance liquid chromatographic assay for the simultaneous quantitative determination of the antimalarial compound artesunic acid (ARS), dihydroartemisinin (DQHS) and artemisinin (QHS), as internal standard, is described. After extraction from plasma, ARS and DQHS were analysed using an Econosil C8 column and a mobile phase of acetonitrile-0.05 M acetic acid (42:58, v/v) adjusted to pH 5.0 and electrochemical detection in the reductive mode. The mean recovery of ARS and DQHS over a concentration range of 50-200 ng/ml was 75.5% and 93.5%, respectively. The within-day coefficients of variation were 4.2-7.4% for ARS and 2.6-4.9% for DQHS. The day-to-day coefficients of variation were 1.6-9.6% and 0.5-8.3%, respectively. The minimum detectable concentration for ARS and DQHS in plasma was 4.0 ng/ml for both compounds. The method was found to be suitable for use in clinical pharmacological studies.
    Matched MeSH terms: Chromatography, High Pressure Liquid
  5. Peh KK, Yuen KH
    J Chromatogr B Biomed Sci Appl, 1997 May 23;693(1):241-4.
    PMID: 9200543
    A simple high-performance liquid chromatographic method using fluorescence detection was developed for the determination of acyclovir in human plasma. The method entailed direct injection of the plasma sample after deproteination. It is both specific and sensitive with a detection limit of 30 ng/ml at a signal-to-noise ratio of 3:1, and is thus suitable for use in pharmacokinetic studies of acyclovir. The method had a mean absolute recovery of 96%, while the within-day and between-day coefficients of variation and percentages error were all less than 8%. The calibration curve was linear over a concentration range of 62.5-4000 ng/ml.
    Matched MeSH terms: Chromatography, High Pressure Liquid
  6. Selvamuniandy TS, Mohamed N, Mansor SM, Nair NK, Navaratnam V
    J Chromatogr B Biomed Sci Appl, 1997 Oct 24;700(1-2):209-13.
    PMID: 9390731
    A selective and sensitive HPLC assay for the quantitative determination of a new antifilarial drug, 6,4'-bis-(2-imidazolinylhydrazone)-2-phenylimidazo[1,2-a]pyr idine (CDR 101) is described. After extraction from plasma and blood, CDR 101 was analysed using a C18 Nucleosil ODS column (250x4.6 mm, 5 microm particle size) and mobile phase of acetonitrile-0.05 M ammonium acetate adjusted to pH 3.0, with UV detection at 318 nm. The mean recoveries of CDR 101 in plasma and blood over a concentration range of 25-500 ng/ml were 95.5+/-2.01% and 83.3+/-1.87%, respectively. The within-day and day-to-day coefficient of variations for plasma were 3.23-6.21% and 2.59-9.90%, respectively, those for blood were 2.59-5.92% and 2.89-6.82%, respectively. The minimum detectable concentration for CDR 101 was 1 ng/ml in plasma and 2.5 ng/ml in whole blood. This method was found to be suitable for clinical pharmacokinetic studies.
    Matched MeSH terms: Chromatography, High Pressure Liquid
  7. Peh KK, Billa N, Yuen KH
    J Chromatogr B Biomed Sci Appl, 1997 Nov 07;701(1):140-5.
    PMID: 9389350
    A simple liquid chromatographic method using amperometric detection was developed for the determination of naltrexone in human plasma. Prior to analysis, naltrexone and the internal standard (naloxone) were extracted from plasma samples using a 9:1 mixture of chloroform and isopropyl alcohol. The mobile phase comprised 0.1 M disodium hydrogen orthophosphate (pH 3.5) and acetonitrile (85.5:14.5, v/v). Analysis was run at a flow-rate of 0.8 ml/min with the detector operating under oxidative mode at an applied potential of +0.95 V. The method is specific and sensitive with a detection limit of approximately 1 ng/ml at a signal-to-noise ratio of 3:1. Mean recovery value of the extraction procedure was about 93%, while the within day and between day coefficient of variation and percent error values of the assay method were all less than 10%. The calibration curve was linear over a concentration range of 1.5-100 ng/ml.
    Matched MeSH terms: Chromatography, Liquid
  8. Malays J Nutr, 1997;3(2):-.
    MyJurnal
    This article examines the fat and fibre intakes of Malaysian adults and highlights discrepancies and practical limitations if these intakes are to match the levels for these nutrients advocated in the World Health Organisation (WHO) and American Heart Association (AHA) ‘diet models’. Local data on food consumption showed that the total fat intakes amongst Malaysian adults, contrary to common perception, were not high and the mean values obtained fell within the range of 40-66g or 22-26% kcal. As such, the dietary target of 30% kcal total fat or its intermediate target of 30-35% kcal, advocated by WHO and AHA mainly to address the problem of a high consumption of dietary fats in western populations, should not be adopted indiscriminately by Malaysians. Dietary fatty acid (FA) analysis by high performance liquid chromatography (HPLC) coupled with the use of food composition tables, showed that the typical Malaysian diet prepared with palm olein or palm olein-groundnut oil blends as cooking oil contained 3.2-4.0% kcal polyunsaturated fatty acids (PUFA), mainly as the w-6 linoleic acid, which is also the predominant essential fatty acid (EFA) in humans. This level of linoleic acid, with an ω-6/ ω--3 FA ratio approximating 10, is adequate for basal PUPA and EFA needs but fell short of the 4-10% kcal linoleic acid recommended by WHO (1993) to counter the effects of the cholesterol-raising saturated fatty acids (SFA). This raised upper limit of 10% kcal linoleic acid (previously 7% kcal), which equals the level of PUFA implied in the AHA diet model, appears unnecessarily high considering that the cholesterol-lowering potential of linoleic acid is maximum at about 6% kcal, while the health hazards associated with long-term high intakes of PUPA have never been completely dismissed. The new WHO lower limit for dietary linoleic acid (4% kcal) would have a controversial impact of raising the previous minimal 3% kcal EFA to above 4% kcal (linoleic + alpha-linolenic acids). Similarly, the WHO recommendation for total dietary fibre of 27-40g (equivalent to a daily combined intake of 400g of vegetables and fruits, 30g of which should come from pulses) appears at present, too high a dietary target for the average Malaysian adult whose habitual daily diet was estimated to contain about 180g of vegetables plus fruits, providing only about 13-16g total dietary fibre. Appropriately, an expert panel on Malaysian Dietary Guidelines has recommended instead, 20-30% kcal total fat containing 3-7% kcal PUFA, and 20-30g total dietary fibre for the local population.
    Matched MeSH terms: Chromatography, High Pressure Liquid
  9. Norliza YH, Mohamed Z, Zaini A, Lang CC
    JUMMEC, 1997;2:23-25.
    Matched MeSH terms: Chromatography
  10. Yuen KH, Peh KK, Billa N, Chan KL, Toh WT
    Drug Dev Ind Pharm, 1998 Feb;24(2):193-6.
    PMID: 15605452
    The bioavailability of a generic preparation of acyclovir (Avorax) was compared with the innovator product, Zovirax. Twelve healthy volunteers participated in the study, conducted according to a randomized, two-way crossover design. The preparations were compared using the parameters area under the plasma concentration time curve (AUC(0-infinity), peak plasma concentration (Cmax), and time to reach peak plasma concentration (Tmax). No statistically significant difference was observed between the Tmax or the logarithmic transformed AUC(0-infinity) and C(max) values of the two preparations. In addition, the 90% confidence interval for the ratio of the logarithmic transformed AUC(0-infinity) values of Avorax over those of Zovirax was found to lie between 0.85 and 1.06, while that of the logarithmic transformed Cmax values was between 0.95 and 1.25, being within the bioequivalence limit of 0.80-1.25. Moreover, the elimination rate constant (k(e)), elimination half-life (t(1/2)), and apparent volume of distribution (Vd) values obtained with the two preparations were comparable and not significantly different statistically.
    Matched MeSH terms: Chromatography, High Pressure Liquid
  11. Jais AM, Matori MF, Kittakoop P, Sowanborirux K
    Gen. Pharmacol., 1998 Apr;30(4):561-3.
    PMID: 9522175
    1. Fatty acid profiles in the external mucus extract and roe of Channa striatus were determined using gas chromatography (GC). 2. The mucus samples were collected by inducing hypothermic stress (-20 degrees C) for about 1 hr, and the roe were collected from gravid females at night soon after they liberated their eggs in a spawning program. 3. All mucus and roe samples were freeze-dried, except a part of roe which was not. 4. The mucus extract contained unsaturated fatty acid (oleic acid, C18:1 and linoleic acid, C18:2) as a major component, 21.25% and 22.47% of total lipid. 5. For the freeze- and nonfreeze-dried roe, the major components of fatty acid were somewhat similar to the mucus but with higher percentages: 58.56%, 26.08% and 45.76%, 20.94%. Interestingly, the nonfreeze-dried roe contained a large proportion of arachidic acid, C20:0 (22.16%), which was totally absent in the freeze-dried roe samples. 6. This profiling of the fatty acid mucus extract and roe is useful in strengthening the earlier claims that haruan possesses a potential remedy for wound healing (Mat Jais et al., 1994). Therefore, we are discussing the possibility of getting an optimum amount of the essential fatty acid for wound healing from various other parts of the fish without sacrificing the fish.
    Matched MeSH terms: Chromatography, Gas
  12. Jeyaseelan K, Armugam A, Lachumanan R, Tan CH, Tan NH
    Biochim. Biophys. Acta, 1998 Apr 10;1380(2):209-22.
    PMID: 9565688
    Cardiotoxins are the most abundant toxin components of cobra venom. Although many cardiotoxins have been purified and characterized by amino acid sequencing and other pharmacological and biochemical studies, to date only five cardiotoxin cDNAs from Taiwan cobra (Naja naja atra), three cDNAs from Chinese cobra (Naja atra) and two more of uncertain origin (either Chinese or Taiwan cobra) have been reported. In this paper we show the existence of four isoforms of cardiotoxin by protein analysis and nine cDNA sequences encoding six isoforms of cardiotoxins (CTX 1-3, 4a, 4b and 5) from N. n. sputatrix by cDNA cloning. This forms the first report on the cloning and characterization of several cardiotoxin genes from a single species of a spitting cobra. The cDNAs encoding these isoforms, obtained by reverse transcription-polymerase chain reaction (RT-PCR), were subsequently expressed in Escherichia coli. The native and recombinant cardiotoxins were first characterized by Western blotting and N-terminal protein sequencing. These proteins were also found to have different levels of cytolytic activity on cultured baby hamster kidney cells. Four of the isoforms (CTX 1, 2, 4 and 5) are unique to N. n. sputatrix, with CTX 2 being the most abundant species constituting about 50% of the total cardiotoxins. The isoform CTX 3 (20% constitution) is highly homologous to the cardiotoxins of N. n. atra and N. n. naja, indicating that it may be universally present in all Naja naja subspecies. Our studies suggest that the most hydrophilic isoform (CTX 5) could have evolved first followed by the hydrophobic isoforms (CTX 1, 2, 3 and 4). We also speculate that Asiatic cobras could be the modern descendants of the African and Egyptian counterparts.
    Matched MeSH terms: Chromatography, High Pressure Liquid
  13. Lam SK, Devine PL
    Clin Diagn Virol, 1998 May 1;10(1):75-81.
    PMID: 9646004
    Rapid diagnosis of dengue infection is essential to patient management and disease control. The development of a rapid (5 min) immunochromatographic test and a 2 h commercial capture enzyme linked immunosorbent assay (ELISA) for anti-dengue IgM and IgG antibodies may lead to more rapid and accurate testing in peripheral health settings and diagnostic laboratories.
    Matched MeSH terms: Chromatography
  14. Rohani MY, Hasnidah D, Ong KH
    Malays J Pathol, 1998 Jun;20(1):31-3.
    PMID: 10879261
    A chromatographic immunoassay cholera antigen detection kit, the Cholera Spot test, was evaluated. The test was found to be specific with a sensitivity of 10(6) cfu/ml for the direct detection of V. cholerae in simulated stool specimens and 10 cfu/ml in simulated cotton-tipped swab specimens after overnight incubation in alkaline peptone water. This enables early recognition of cholera cases and their contacts so that prevention and control measures can be promptly instituted.
    Matched MeSH terms: Chromatography
  15. Kah Hay Yuen, Kok Khiang Peh
    J Chromatogr B Biomed Sci Appl, 1998 Jun 12;710(1-2):243-6.
    PMID: 9686895
    A simple high-performance liquid chromatographic method using ultraviolet detection was developed for the determination of metformin in human plasma. The method entailed direct injection of the plasma sample after deproteination using perchloric acid. The mobile phase comprised 0.01 M potassium dihydrogen orthophosphate (pH 3.5) and acetonitrile (60:40, v/v). Analyses were run at a flow-rate of 1.0 ml/min with the detector operating at a detection wavelength of 234 nm. The method is specific and sensitive, with a quantification limit of approximately 60 ng/ml and a detection limit of 15 ng/ml at a signal-to-noise ratio of 3:1. The mean absolute recovery value was about 97%, while the within-day and between-day coefficient of variation and percent error values of the assay method were all less than 8%. The calibration curve was linear over a concentration range of 62.5-4000 ng/ml.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  16. Yuen KH, Peh KK
    J Chromatogr B Biomed Sci Appl, 1998 Sep 18;715(2):436-40.
    PMID: 9792531
    A simple high-performance liquid chromatographic method using fluorescence detection was developed for the determination of ketoconazole in human plasma. The method entailed direct injection of the plasma sample after deproteinization using acetonitrile. The mobile phase comprised 0.05 M disodium hydrogen orthophosphate and acetonitrile (50:50, v/v) adjusted to pH 6. Analysis was run at a flow-rate of 1.5 ml/min with the detector operating at an excitation wavelength of 260 nm and an emission wavelength of 375 nm. The method is specific and sensitive with a quantification limit of approximately 60 ng/ml and a detection limit of 40 ng/ml at a signal-to-noise ratio of 3:1. Mean absolute recovery value was about 105%, while the within-day and between-day coefficient of variation and percent error values of the assay method were all less than 14%. The calibration curve was linear over a concentration range of 62.5-8000 ng/ml.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  17. Jia Woei Wong, Kah Hay Yuen, Kok Khiang Peh
    J Chromatogr B Biomed Sci Appl, 1998 Sep 25;716(1-2):387-91.
    PMID: 9824257
    A simple high-performance liquid chromatographic method using ultraviolet detection was developed for the determination of pentoxifylline in human plasma. Prior to analysis, pentoxifylline and the internal standard (chloramphenicol) were extracted from plasma sample using dichloromethane. The mobile phase comprised 0.02 M phosphoric acid adjusted to pH 4, methanol and tetrahydrofuran (55:45:1, v/v). Analysis was run at a flow-rate of 1.4 ml/min with the detector operated at a wavelength of 273 nm. The method was specific and sensitive with a detection limit of approximately 3.0 ng/ml at a signal to noise ratio of 3:1, while the limit of quantification was 12.5 ng/ml. Mean recovery value of the extraction procedure was about 99.9%, while the within-day and between-day coefficient of variation and percent error values of the assay method were all less than 10.0%. The calibration curve was linear over a concentration range of 12.5-400.0 ng/ml.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  18. Wong CF, Peh KK, Yuen KH
    J Chromatogr B Biomed Sci Appl, 1998 Oct 23;718(1):205-10.
    PMID: 9832378
    A simple high-performance liquid chromatographic method was developed for the determination of ranitidine in human plasma. Prior to analysis, ranitidine and the internal standard (metoprolol) were extracted from alkalinized plasma samples using dichloromethane. The mobile phase was 0.05 M potassium dihydrogenphosphate-acetonitrile (88:12, v/v) adjusted to pH 6.5. Analysis was run at a flow-rate of 1.3 ml/min and at a detection wavelength of 229 nm. The method is sensitive with a detection limit of 1 ng/ml at a signal-to-noise ratio of 3:1, while the quantification limit was set at 15 ng/ml. The calibration curve was linear over a concentration range of 15-2000 ng/ml. Mean recovery value of the extraction procedure was about 90%, while the within-day and between-day coefficients of variation and percent error values of the assay method were all less than 15%.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  19. Saad B, Ariffin M, Saleh MI
    Talanta, 1998 Dec;47(5):1231-6.
    PMID: 18967428
    A flow injection potentiometric method for the rapid determination of paraquat in herbicide formulations and biological samples is described. It is based on the utilization of a flow-through potentiometric detector containing polyvinyl chloride-immobilised octamethylcyclotetrasiloxane, a lipophilic plasticizer (tetra-n-undecyl 3,3',4,4'-benzophenone tetracarboxylate) and membrane additive potassium tetrakis(4-chlorophenyl)borate. The detector was minimally interfered by the presence of constituents such as Na(+), K(+), Ca(2+), Mg(2+), glucose, urea, lactic and citric acids at physiological levels, respectively. Good correlation between results of the proposed method and HPLC for the formulation samples was found, while results for the determination of paraquat in biological samples such as urine, vomitus and stomach washout was less satisfactory.
    Matched MeSH terms: Chromatography, High Pressure Liquid
  20. Chan KL, Choo CY, Morita H, Itokawa H
    Planta Med, 1998 Dec;64(8):741-5.
    PMID: 17253320 DOI: 10.1055/s-2006-957570
    An analytical method using HPLC with UV detection was developed to investigate the quassinoid content of Eurycoma longifolia Jack (Simaroubaceae) collected from various sources. Eurycomanone (1), longilactone (2), 14,15beta-dihydroxyklaineanone (3), 15beta-acetyl-14-hydroxyklaineanone (4), 6alpha-hydroxyeurycomalactone (5), and eurycomalactone (7) were isolated as reference standards and together with the synthesized 1beta,12alpha,15beta-triacetyleurycomanone (6, internal standard), were identified by NMR, MS, UV and IR spectroscopies. Their coefficient of variation values for 0.50-35 microg ml(-1) concentrations of quassinoids and their retention times measured within- and between-day were small. The recoveries of the spiked quassinoids in E. longifolia samples and their detection limits at 8.5 times signal to noise ratio were 99.75-109.13% and 0.01 microg ml(-1), respectively. From the root samples analysed, 1 had the highest concentration, being about 16.8-39.6 fold higher than the other quassinoids 2, 3, 5, 7 but 145.3 fold higher than 4 which showed the lowest concentration.
    Matched MeSH terms: Chromatography, High Pressure Liquid
Filters