Displaying publications 81 - 100 of 415 in total

Abstract:
Sort:
  1. George E, Wong HB
    Singapore Med J, 1993 Dec;34(6):500-3.
    PMID: 8153710
    Patients with the Hb beta + [IVS 1-5 (G-->C)] clinically presented as beta-thalassaemia intermedia and remained asymptomatic in the absence of blood transfusions. With or without blood transfusions the patients were short and had moderate to marked thalassaemia facies. Children who received blood transfusions showed progressive iron loading with age. The serum ferritin and serum alanine transaminase levels were significantly raised in the patients who were given blood transfusions. In the presence of blood transfusions, and absence of adequate iron chelation therapy, splenectomy became an inevitable event at some stage of the disease because of increasing transfusing requirements.
    Matched MeSH terms: Iron Chelating Agents/therapeutic use
  2. George E, Wong HB, Jamaluddin M, Huisman TH
    Singapore Med J, 1993 Jun;34(3):241-4.
    PMID: 8266182
    Following complete DNA characterisation patients with Hb H disease were assigned into two groups: deletional (alpha +/alpha o) and non deletional (HbCS/alpha o). Earlier studies have indicated that the group with (HbCS/alpha o) has more severe clinical problems. The serum malonyldialdehyde (MDA) levels, a secondary product of lipid peroxidation were within the normal range, though significantly higher levels of MDA were seen in the non-deletional type of Hb H disease when compared with the deletional type. Markedly low vitamin E levels were also seen in the former group. There were no significant differences in clinical severity may be attributed to an interplay of the accelerated destruction of damaged mature red blood cells secondary to the oxidative denaturation of Hb H and inclusion precipitation; higher levels of Hb H and more inclusion precipitation were seen in the group with (HbCS/alpha o). Low levels of vitamin E in the (HbCS/alpha o) group being due to its consumption in the neutralisation of free radicals formed with the oxidation of globin chains.
    Matched MeSH terms: Iron/blood*
  3. Paul FM
    Singapore Med J, 1974 Dec;15(4):231-40.
    PMID: 4458066
    Ninety-six cases of severe malnutrition and associated nutritional disorders were encountered in children in the department of paediatrics for the year 1971. The predominant age group was in children under the age of two years. Malay and Indian children were affected more than the Chinese children with malnutrition. Protein caloric malnutrition had already affected the growth pattern of these children as the majority were below the 50th percentile in height and weight comparing them with Hong Kong childrens’ height and weight standards. Seventy-five per cent of the children presented with infection. Fifty-four per cent of the families with malnutrition had three to six children and in two thirds of the families the income was from $100/- to $249/- per month. Forty per cent of the children lived in the kampong type of houses with no proper sanitation. Worm infestation was common in this group. The mean haemoglobin, serum iron levels, and serum folic acid levels were lower in the Indians and Malays. Protein caloric malnutrition must be treated early because of its irreversible effects on brain and bone growth. It is recommended that some form of allowance either in the form of food or money be given to these children from poor social-economic background.
    Matched MeSH terms: Iron/blood
  4. Abdullah HR, Ang AL, Froessler B, Hofmann A, Jang JH, Kim YW, et al.
    Singapore Med J, 2020 Jun;61(6):287-296.
    PMID: 31044255 DOI: 10.11622/smedj.2019037
    Preoperative anaemia is common in the Asia-Pacific. Iron deficiency anaemia (IDA) is a risk factor that can be addressed under patient blood management (PBM) Pillar 1, leading to reduced morbidity and mortality. We examined PBM implementation under four different healthcare systems, identified challenges and proposed several measures: (a) Test for anaemia once patients are scheduled for surgery. (b) Inform patients about risks of preoperative anaemia and benefits of treatment. (c) Treat IDA and replenish iron stores before surgery, using intravenous iron when oral treatment is ineffective, not tolerated or when rapid iron replenishment is needed; transfusion should not be the default management. (d) Harness support from multiple medical disciplines and relevant bodies to promote PBM implementation. (e) Demonstrate better outcomes and cost savings from reduced mortality and morbidity. Although PBM implementation may seem complex and daunting, it is feasible to start small. Implementing PBM Pillar 1, particularly in preoperative patients, is a sensible first step regardless of the healthcare setting.
    Matched MeSH terms: Iron/administration & dosage*; Anemia, Iron-Deficiency/drug therapy*
  5. Norhaniza R, Mazlan SA, Ubaidillah U, Sedlacik M, Aziz SAA, Nazmi N, et al.
    Sensors (Basel), 2021 Feb 28;21(5).
    PMID: 33670872 DOI: 10.3390/s21051660
    Magnetoactive (MA) foam, with its tunable mechanical properties and magnetostriction, has the potential to be used for the development of soft sensor technology. However, researchers have found that its mechanical properties and magnetostriction are morphologically dependent, thereby limiting its capabilities for dexterous manipulation. Thus, in this work, MA foam was developed with additional capabilities for controlling its magnetostriction, normal force, storage modulus, shear stress and torque by manipulating the concentration of carbonyl iron particles (CIPs) and the magnetic field with regard to morphological changes. MA foams were prepared with three weight percentages of CIPs, namely, 35 wt.%, 55 wt.% and 75 wt.%, and three different modes, namely, zero shear, constant shear and various shears. The results showed that the MA foam with 75 wt.% of CIPs enhanced the normal force sensitivity and positive magnetostriction sensitivity by up to 97% and 85%, respectively. Moreover, the sensitivities of the storage modulus, torque and shear stress were 8.97 Pa/mT, 0.021 µN/mT, and 0.0096 Pa/mT, respectively. Meanwhile, the magnetic dipolar interaction between the CIPs was capable of changing the property of MA foam from a positive to a negative magnetostriction under various shear strains with a low loss of energy. Therefore, it is believed that this kind of highly sensitive MA foam can potentially be implemented in future soft sensor systems.
    Matched MeSH terms: Iron; Iron Carbonyl Compounds
  6. Yap BK, M Soair SN, Talik NA, Lim WF, Mei I L
    Sensors (Basel), 2018 Aug 10;18(8).
    PMID: 30103424 DOI: 10.3390/s18082625
    Over the past 20 years, rapid technological advancement in the field of microfluidics has produced a wide array of microfluidic point-of-care (POC) diagnostic devices for the healthcare industry. However, potential microfluidic applications in the field of nutrition, specifically to diagnose iron deficiency anemia (IDA) detection, remain scarce. Iron deficiency anemia is the most common form of anemia, which affects billions of people globally, especially the elderly, women, and children. This review comprehensively analyzes the current diagnosis technologies that address anemia-related IDA-POC microfluidic devices in the future. This review briefly highlights various microfluidics devices that have the potential to detect IDA and discusses some commercially available devices for blood plasma separation mechanisms. Reagent deposition and integration into microfluidic devices are also explored. Finally, we discuss the challenges of insights into potential portable microfluidic systems, especially for remote IDA detection.
    Matched MeSH terms: Anemia, Iron-Deficiency/diagnosis*
  7. Zubir NA, Yacou C, Motuzas J, Zhang X, Diniz da Costa JC
    Sci Rep, 2014;4:4594.
    PMID: 24699690 DOI: 10.1038/srep04594
    Graphene oxide-iron oxide (GO-Fe3O4) nanocomposites were synthesised by co-precipitating iron salts onto GO sheets in basic solution. The results showed that formation of two distinct structures was dependent upon the GO loading. The first structure corresponds to a low GO loading up to 10 wt%, associated with the beneficial intercalation of GO within Fe3O4 nanoparticles and resulting in higher surface area up to 409 m(2) g(-1). High GO loading beyond 10 wt% led to the aggregation of Fe3O4 nanoparticles and the undesirable stacking of GO sheets. The presence of strong interfacial interactions (Fe-O-C bonds) between both components at low GO loading lead to 20% higher degradation of Acid Orange 7 than the Fe3O4 nanoparticles in heterogeneous Fenton-like reaction. This behaviour was attributed to synergistic structural and functional effect of the combined GO and Fe3O4 nanoparticles.
    Matched MeSH terms: Iron
  8. Hassan MA, Mahmoodian R, Hamdi M
    Sci Rep, 2014;4:3724.
    PMID: 24430621 DOI: 10.1038/srep03724
    A modified smoothed particle hydrodynamic (MSPH) computational technique was utilized to simulate molten particle motion and infiltration speed on multi-scale analysis levels. The radial velocity and velocity gradient of molten alumina, iron infiltration in the TiC product and solidification rate, were predicted during centrifugal self-propagating high-temperature synthesis (SHS) simulation, which assisted the coating process by MSPH. The effects of particle size and temperature on infiltration and solidification of iron and alumina were mainly investigated. The obtained results were validated with experimental microstructure evidence. The simulation model successfully describes the magnitude of iron and alumina diffusion in a centrifugal thermite SHS and Ti + C hybrid reaction under centrifugal acceleration.
    Matched MeSH terms: Iron
  9. Yusop AH, Daud NM, Nur H, Kadir MR, Hermawan H
    Sci Rep, 2015;5:11194.
    PMID: 26057073 DOI: 10.1038/srep11194
    Iron and its alloy have been proposed as biodegradable metals for temporary medical implants. However, the formation of iron oxide and iron phosphate on their surface slows down their degradation kinetics in both in vitro and in vivo scenarios. This work presents new approach to tailor degradation behavior of iron by incorporating biodegradable polymers into the metal. Porous pure iron (PPI) was vacuum infiltrated by poly(lactic-co-glycolic acid) (PLGA) to form fully dense PLGA-infiltrated porous iron (PIPI) and dip coated into the PLGA to form partially dense PLGA-coated porous iron (PCPI). Results showed that compressive strength and toughness of the PIPI and PCPI were higher compared to PPI. A strong interfacial interaction was developed between the PLGA layer and the iron surface. Degradation rate of PIPI and PCPI was higher than that of PPI due to the effect of PLGA hydrolysis. The fast degradation of PIPI did not affect the viability of human fibroblast cells. Finally, this work discusses a degradation mechanism for PIPI and the effect of PLGA incorporation in accelerating the degradation of iron.
    Matched MeSH terms: Iron/chemistry*
  10. Burhannuddin NL, Nordin NA, Mazlan SA, Aziz SAA, Kuwano N, Jamari SKM, et al.
    Sci Rep, 2021 Jan 13;11(1):868.
    PMID: 33441824 DOI: 10.1038/s41598-020-80539-z
    Carbonyl iron particles (CIPs) is one of the key components in magnetic rubber, known as magnetorheological elastomer (MRE). Apart from the influence of their sizes and concentrations, the role of the particle' shape is pronounced worthy of the attention for the MRE performance. However, the usage of CIPs in MRE during long-term applications may lead to corrosion effects on the embedded CIPs, which significantly affects the performance of devices or systems utilizing MRE. Hence, the distinctions between the two types of MRE embedded in different shapes of spherical and plate-like CIPs, at both conditions of non-corroded and corroded CIPs were investigated in terms of the field-dependent rheological properties of MRE. The plate-like shape was produced from spherical CIPs through a milling process using a rotary ball mill. Then, both shapes of CIPs individually subjected to an accelerated corrosion test in diluted hydrochloric (HCl) at different concentrations, particularly at 0.5, 1.0, and 1.5 vol.% for 30 min of immersion time. Eight samples of CIPs, including non-corroded for both CIPs shapes, were characterized in terms of a morphological study by field emission scanning electron microscope (FESEM) and magnetic properties via vibrating sample magnetometer (VSM). The field-dependent rheological properties of MREs were analyzed the change in the dynamic modulus behavior of MREs via rheometer. From the application perspective, this finding may be useful for the system to be considered that provide an idea to prolong the performance MRE by utilizing the different shapes of CIPs even when the material is fading.
    Matched MeSH terms: Iron; Iron Carbonyl Compounds
  11. Johari MAF, Mazlan SA, Nasef MM, Ubaidillah U, Nordin NA, Aziz SAA, et al.
    Sci Rep, 2021 May 25;11(1):10936.
    PMID: 34035434 DOI: 10.1038/s41598-021-90484-0
    The widespread use of magnetorheological elastomer (MRE) materials in various applications has yet to be limited due to the fact that there are substantial deficiencies in current experimental and theoretical research on its microstructural durability behavior. In this study, MRE composed of silicon rubber (SR) and 70 wt% of micron-sized carbonyl iron particles (CIP) was prepared and subjected to stress relaxation evaluation by torsional shear load. The microstructure and particle distribution of the obtained MRE was evaluated by a field emission scanning electron microscopy (FESEM). The influence of constant low strain at 0.01% is the continuing concern within the linear viscoelastic (LVE) region of MRE. Stress relaxation plays a significant role in the life cycle of MRE and revealed that storage modulus was reduced by 8.7%, normal force has weakened by 27%, and stress performance was reduced by 6.88% along approximately 84,000 s test duration time. This time scale was the longest ever reported being undertaken in the MRE stress relaxation study. Novel micro-mechanisms that responsible for the depleted performance of MRE was obtained by microstructurally observation using FESEM and in-phase mode of atomic force microscope (AFM). Attempts have been made to correlate strain localization produced by stress relaxation, with molecular deformation in MRE amorphous matrix. Exceptional attention was focused on the development of molecular slippage, disentanglement, microplasticity, microphase separation, and shear bands. The relation between these microstructural phenomena and the viscoelastic properties of MRE was diffusely defined and discussed. The presented MRE is homogeneous with uniform distribution of CIP. The most significant recent developments of systematic correlation between the effects of microstructural deformation and durability performance of MRE under stress relaxation has been observed and evaluated.
    Matched MeSH terms: Iron
  12. Ariffin EY, Zakariah EI, Ruslin F, Kassim M, Yamin BM, Heng LY, et al.
    Sci Rep, 2021 Apr 12;11(1):7883.
    PMID: 33846405 DOI: 10.1038/s41598-021-86939-z
    Ferrocene or ferrocenium has been widely studied in the field of organometallic complexes because of its stable thermodynamic, kinetic and redox properties. Novel hexaferrocenium tri[hexa(isothiocyanato)iron(III)]trihydroxonium (HexaFc) complex was the product from the reaction of ferrocene, maleic acid and ammonium thiocyanate and was confirmed by elemental analysis CHNS, FTIR and single crystal X-ray crystallography. In this study, HexaFc was used for the first time as an electroactive indicator for porcine DNA biosensor. The UV-Vis DNA titrations with this compound showed hypochromism and redshift at 250 nm with increasing DNA concentrations. The binding constant (Kb) for HexaFc complex towards CT-DNA (calf-thymus DNA) was 3.1 × 104 M-1, indicated intercalator behaviour of the complex. To test the usefulness of this complex for DNA biosensor application, a porcine DNA biosensor was constructed. The recognition probes were covalently immobilised onto silica nanospheres (SiNSs) via glutaraldehyde linker on a screen-printed electrode (SPE). After intercalation with the HexaFc complex, the response of the biosensor to the complementary porcine DNA was measured using differential pulse voltammetry. The DNA biosensor demonstrated a linear response range to the complementary porcine DNA from 1 × 10-6 to 1 × 10-3 µM (R2 = 0.9642) with a limit detection of 4.83 × 10-8 µM and the response was stable up to 23 days of storage at 4 °C with 86% of its initial response. The results indicated that HexaFc complex is a feasible indicator for the DNA hybridisation without the use of a chemical label for the detection of porcine DNA.
    Matched MeSH terms: Iron/chemistry*
  13. Mat Nasir N, Md Isa Z, Ismail NH, Ismail R, Mohd Tamil A, Jaafar MH, et al.
    Sci Rep, 2024 Apr 13;14(1):8590.
    PMID: 38615144 DOI: 10.1038/s41598-024-59206-0
    Hypertension (HPT) is the leading modifiable risk factor for cardiovascular diseases and premature death worldwide. Currently, attention is given to various dietary approaches with a special focus on the role of micronutrient intake in the regulation of blood pressure. This study aims to measure the dietary intake of selected minerals among Malaysian adults and its association with HPT. This cross-sectional study involved 10,031 participants from the Prospective Urban and Rural Epidemiological study conducted in Malaysia. Participants were grouped into HPT if they reported having been diagnosed with high blood pressure [average systolic blood pressure (SBP)/average diastolic blood pressure (DBP) ≥ 140/90 mm Hg]. A validated food frequency questionnaire (FFQ) was used to measure participants' habitual dietary intake. The dietary mineral intake of calcium, copper, iron, magnesium, manganese, phosphorus, potassium, sodium, and zinc was measured. The chi-square test was used to assess differences in socio-demographic factors between HPT and non-HPT groups, while the Mann-Whitney U test was used to assess differences in dietary mineral intake between the groups. The participants' average dietary intake of calcium, copper, iron, magnesium, manganese, phosphorus, potassium, selenium, sodium, and zinc was 591.0 mg/day, 3.8 mg/day, 27.1 mg/day, 32.4 mg/day, 0.4 mg/day, 1431.1 mg/day, 2.3 g/day, 27.1 µg/day, 4526.7 mg/day and 1.5 mg/day, respectively. The intake was significantly lower among those with HPT than those without HPT except for calcium and manganese. Continuous education and intervention should be focused on decreasing sodium intake and increasing potassium, magnesium, manganese, zinc, and calcium intake for the general Malaysian population, particularly for the HPT patients.
    Matched MeSH terms: Iron
  14. Webb JF
    Sci Prog, 2003;86(Pt 3):203-34.
    PMID: 15079997
    The main physical properties of ferroelectric crystals are described, and the macroscopic and microscopic viewpoints are discussed along with some applications, such as in capacitors and nonlinear optics. The emphasis is on physical understanding, while the mathematical level is kept to a minimum or supplemented by graphical representations to make the article more accessible.
    Matched MeSH terms: Iron/chemistry*
  15. Chan KW, Tan GH, Wong RC
    Sci Justice, 2013 Mar;53(1):73-80.
    PMID: 23380066 DOI: 10.1016/j.scijus.2012.08.004
    Sixteen trace elements found in 309 street heroin samples, piped water and contaminated water were determined using inductively coupled plasma-mass spectrometry. All the street heroin samples were found to contain high levels of sodium, a reflection of the use of sodium bicarbonate during heroin synthesis. Additionally, this element was also found to be one of the potential contaminants acquired from the piped water. Calcium could be derived from lime while iron, aluminum and zinc could have come from the metallic container used in the processing/cutting stage. The levels of these elements remained low in the heroin and it could be due to the dilution effects from the addition of adulterants. Statistical validation was performed with six links of related heroin samples using principal component analysis to find the best pretreatment for sample classification. It was obtained that normalization followed by fourth root showed promising results with 8% errors in the sample clustering. The technique was then applied to the case samples. Finally, the result suggested that the case samples could have originated from at least two major groups respectively showing unique elemental profiles at the street level.
    Matched MeSH terms: Iron
  16. Nik Nur Izzati Nik Mohd Fakhruddin, Suzana Shahar, Nurul Atiqah Abd Aziz, Roslee Rajikan, Hanis Mastura Yahya
    Sains Malaysiana, 2016;45:1381-1391.
    Older adults quite often had an inadequate diet leading to micronutrient deficiencies and impaired immune response with subsequent development of degenerative diseases. This study aimed to determine the adequacy of energy and nutrient intake and its distribution among three aging groups i.e. successful aging (SA), usual aging (UA) and mild cognitive impairment (MCI). This is a cross-sectional study involving a large sample size (n = 2322) of older adults recruited through multistage random sampling from four states of Malaysia. An interview was conducted to measure dietary intake, neurocognitive status and functional status by using the Diet History Questionnaire (DHQ), Mini-Mental State Examination (MMSE), Rey Auditory Learning Test (RAVLT), Geriatric Depression Scale (GDS), Instrumental Activity of Daily Living (IADL) and Quality of Life Questionnaire. For comparison of dietary intake, a sub-sample of 173 respondents from each aging groups were matched and selected using a comparative cross-sectional approach. Women in SA group had the highest mean intake of vitamin A, calcium (p <0.05), vitamin C, riboflavin and iron (p<0.001). The same aging group also achieved the highest RNI percentage for the same nutrients. More than 80% of respondents for all aging groups did not met the recommended nutrient intake (RNI) for vitamin E, thiamin, niacin, folate, calcium and zinc. In women, MCI respondents were more likely to have an inadequate intake of vitamin A, C, riboflavin and iron followed by UA and SA. Inadequate vitamin E, niacin, folate and calcium were prevalent among all gender and aging groups. There is a need to further distinguish specific dietary patterns associated with these three aging groups to promote optimal nutrient intake for cognitive health.
    Matched MeSH terms: Iron
  17. Fathul Karim Sahrani, Zaharah Ibrahim, Madzlan Aziz, Adibah Yahya
    Corrosion caused by sulphate-reducing bacteria (SRB) isolated from seawater nearby to Pasir Gudang has been studied. The test coupon was a AISI 304 stainless steel. Potential and corrosion rate measurements were carried out in various types of culturing solutions, with SRB1, SRB2, combination of SRB1 & SRB2 and without SRBs inoculated (sterilized). From Tafel plots a higher corrosion rate has been found in medium inoculated with SRBs than that of the sterilized medium (control). When SRBs were present in the medium, the Tafel plot shifted towards more negative values (Ecorr was shifted to much less anodic values) and increase in current density compared to that of the sterilized medium (control). Localized corrosion was observed on the metal surface, and it was associated to the SRB activity. X-ray analysis (EDAX) showed that the corrosion product has higher content of sulphur for medium containing SRBs than that of the sterilized medium. X-Ray Diffraction analysis carried out on corrosion products which showed the presence of iron sulphide. This indicates the influence of the presence of SRB in corrosion process.
    Matched MeSH terms: Iron
  18. Kok KY, Ng IK
    The effects of Fe buffer layer on the microstructures and GMR property of magnetron sputtered Co/Cu multilayers were studied. The main focus was to systematically identify the types of microstructural features present in the multilayers and to determine their characteristic length scales via qualitative and quantitative microstructural characterisation techniques. Both diffraction and imaging techniques were used to extract useful information on layering and crystallographic structures of the materials. This has provided an insight into the structure-property relationship of the materials system. Co/Cu multilayered samples grown with iron buffer layers were found to display better structural coherency and layering quality as compared to those grown without the iron buffer layers. The high GMR effect as demonstrated by these multilayers was associated with highly correlated interface profiles, sharp columnar grain boundaries and high degree of lateral coherency in columnar grain growth.
    Matched MeSH terms: Iron
  19. Wan Md Zin Wan Yunus, Md Jelas Haron
    Poly(hydroxamic acid) ion exchange resin was evaluated for speciation of iron(II) and iron(III) ions. Distribution coefficients indicate that the resin is more selective towards iron(III) ion. Column extractions show that iron(III) ion is quantatively extracted from sulfuric acid solutions at concentrations of between 0.01 to 0.00lM but only 2% or less of iron(II) ion is retained under these conditions. Further studies show that these two ions can be separated and their separations are not affected by the presence of nickel, zinc, copper, calcium, chloride, bromide, nitrate and sulphate.
    Resin penukar ion poli(asid hidroksamik) telah dikaji untuk penspesiesan ion-ionferum. Pekali taburan menunjukkan resin ini mempunyai kepilihan yang tinggi terhadap ion ferik berbanding dengan ionferus. Pengekstrakan dengan kaedah turus mendapati ion ferik dari larutan asid sulfurik 0.01 dan 0.00lM boleh diesktrak secara kuantitatif manakala pengekstrakan ion ferus hanya 2% atau lebih kecil. Kajian lanjut menunjukkan resin ini boleh memisahkan ion ferik dari ion ferus dan pemisahan ini tidak diganggu oleh kehadiran ion-ion nikel, zink, kuprum, kalsium, klorida, bromida, nitrat dan sulfat.
    Matched MeSH terms: Iron
  20. Ibrahim N, Baqiah H, Abdullah M
    Sains Malaysiana, 2013;42:961-966.
    High quality indium oxide and iron doped indium oxide nanocrystalline films were prepared by the sol-gel method followed by a spin coating technique. The samples were characterized by an X-ray diffractometer, an atomic force microscopy and a UV-vis spectroscopy. All samples had good crystallinity with a preferred orientation in the (222) direction. The crystallite size increased from 12.1 nm for the pure sample to 16.1 nm for the sample with x=0.35 and then decreased to 12.1 nm for the sample with x=0.45. All samples contained nanometer grain sizes with a smooth surface. All films showed a high transmission of over 91% in the wavelength range of 200-800 nm.
    Matched MeSH terms: Iron
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links