  1. Lopez JB, Balasegaram M, Timor J, Thambyrajah V
    Malays J Pathol, 1997 Jun;19(1):53-8.
    PMID: 10879242
    Although alpha-fetoprotein (AFP) is regarded as the reference marker for hepatocellular carcinoma (HCC), it sometimes produces false results. The objective of this study was to see if some of the readily available laboratory markers could complement AFP to improve the laboratory diagnosis of HCC. The markers tested and their sensitivities were: CA 125, 92%; ferritin, 71.3%; CA 19-9, 69.8%; beta-2-microglobulin (B2M), 53.3%; CA 72-4, 13.6%; and carcinoembryonic antigen (CEA), 10.6%. In comparison, AFP had a sensitivity of 58.8%. CA 72-4 and CEA (at the "tumour" cut-off level of 20 ng/ml) had specificities of 100%, and AFP, 97.4%. The specificities of the other markers were less impressive: CEA, 77.8% (at the cut-off level of 5 ng/ml); ferritin, 48.6%; CA 125, 48.5%; B2M, 39.6%; and CA 19-9, 37.3%. The efficiencies of the markers for HCC, which are based on the consideration of sensitivity and specificity together, were as follows: AFP, 77.6%; CA 125, 71.3%; ferritin, 60.5%; CA 19-9, 55.3; B2M, 46.9%; CEA, 40.8%; and CA 72-4, 34.5%. The receiver-operating characteristic plots confirmed AFP to be the most efficient marker for HCC. Nevertheless, it is proposed that CA 125 be combined with AFP for HCC screening because of their excellent sensitivity and specificity, respectively: a negative result for both, or even just CA 125 alone, would indicate that the disease is unlikely while a positive AFP (which would likely occur with a positive CA 125) would make its presence highly probable. A positive CA 125 and negative AFP would be equivocal for HCC. Other markers in combination with AFP are less useful.
    Matched MeSH terms: Sensitivity and Specificity
  2. Normaznah Y, Furuta T, Saniah K, Noor Rain A, Kojima S, Mak JW
    PMID: 9444035
    Matched MeSH terms: Sensitivity and Specificity
  3. Boo NY, Cheong KB, Cheong SK, Lye MS, Zulfiqar MA
    J Paediatr Child Health, 1997 Aug;33(4):329-34.
    PMID: 9323622
    OBJECTIVES: To compare the overall accuracy of the stable microbubble test (SM test) with measurement of level of surfactant protein A (SP-A) of tracheal aspirate for the diagnosis of respiratory distress syndrome (RDS).

    METHODOLOGY: Tracheal aspirates were obtained from neonates on ventilatory support. The SM test was carried out on specimens of tracheal aspirate immediately after collection. Levels of SP-A in tracheal aspirates were determined by enzyme-linked immunosorbent assay (ELISA) method. The results of the SM test and SP-A level of the tracheal aspirates were compared against the clinical diagnosis of RDS based on clinical, radiological and bacteriological findings.

    RESULTS: Both the median microbubble counts (6 microbubbles/mm2, range = 0-90) and median SP-A levels (100 micrograms/L, range = 0-67447) of infants with RDS were significantly lower than those of infants with no obvious lung pathology (P < 0.0001), and pneumonia (P < 0.0001). The SM test of tracheal aspirates had higher overall accuracy for the diagnosis of RDS than measurement of SP-A levels (94.6% vs 82.4%). When the receiver operating characteristic (ROC) curves of both tests for RDS were compared, the area under the ROC curve of the SM test was larger (0.9689) than that of the SP-A method (0.8965).

    CONCLUSIONS: This study showed that the SM test of tracheal aspirate was a useful bedside diagnostic test for RDS. It could be carried out at any time after birth on infants requiring ventilatory support.

    Matched MeSH terms: Sensitivity and Specificity
  4. Eamsobhana P, Yong HS, Mak JW, Wattanakulpanich D
    PMID: 9561620
    A dot-blot ELISA was compared with a previously performed sandwich ELISA for the detection of Parastrongylus cantonensis antigens in sera from patients. Using the same monoclonal antibody and the same sera, 6 of 10 sera (60%) from parastronglyiasis patients were positive in dot-blot ELISA, whereas with sandwich ELISA, 5 of the same patient sera (50%) were positive. The specificity in both assays was 100% using 50 sera from patients with other parasitic diseases; of these, 10 each were from patients with cysticercosis, filariasis, gnathostomiasis, malaria and toxocariasis. The control group consisted of 53 sera from normal health Thais and Malaysians. The sensitivity of the assays was, however, slightly better with dot-blot ELISA and because it is simple, quick and cost-effective, it may be a test of choice for specific diagnosis of human parastrongyliasis.
    Matched MeSH terms: Sensitivity and Specificity
  5. Ho TM, DeBruynne J, Ahamad M, Darussamin H
    Asian Pac J Allergy Immunol, 1997 Sep;15(3):123-6.
    PMID: 9438543
    The MAST CLA system was evaluated against skin prick test (SPT) for diagnosis of allergies to house dust mites (Dermatophagoides pteronyssinus, Dermatophagoides farinae) and cats. Forty three asthmatic children were examined by SPT and MAST CLA. Chi-square analysis indicated significant association between SPT and MAST CLA results for the house dust mites but not for cats. The sensitivities of MAST CLA for house dust mites and cats were 100 and 25% respectively; specificities were all less than 50%. The efficiency of MAST CLA for detection of allergy to the house dust mites was 88% and 44% for cats. A significant linear correlation was found between SPT wheal size and MAST CLA grade for D. farinae but not for D. pteronyssinus and cats. It is concluded that the MAST CLA allergy system can be used to supplement SPT for diagnosis of allergies to house dust mites but not to cats.
    Matched MeSH terms: Sensitivity and Specificity
  6. Selvamuniandy TS, Mohamed N, Mansor SM, Nair NK, Navaratnam V
    J Chromatogr B Biomed Sci Appl, 1997 Oct 24;700(1-2):209-13.
    PMID: 9390731
    A selective and sensitive HPLC assay for the quantitative determination of a new antifilarial drug, 6,4'-bis-(2-imidazolinylhydrazone)-2-phenylimidazo[1,2-a]pyr idine (CDR 101) is described. After extraction from plasma and blood, CDR 101 was analysed using a C18 Nucleosil ODS column (250x4.6 mm, 5 microm particle size) and mobile phase of acetonitrile-0.05 M ammonium acetate adjusted to pH 3.0, with UV detection at 318 nm. The mean recoveries of CDR 101 in plasma and blood over a concentration range of 25-500 ng/ml were 95.5+/-2.01% and 83.3+/-1.87%, respectively. The within-day and day-to-day coefficient of variations for plasma were 3.23-6.21% and 2.59-9.90%, respectively, those for blood were 2.59-5.92% and 2.89-6.82%, respectively. The minimum detectable concentration for CDR 101 was 1 ng/ml in plasma and 2.5 ng/ml in whole blood. This method was found to be suitable for clinical pharmacokinetic studies.
    Matched MeSH terms: Sensitivity and Specificity
  7. Peh KK, Billa N, Yuen KH
    J Chromatogr B Biomed Sci Appl, 1997 Nov 07;701(1):140-5.
    PMID: 9389350
    A simple liquid chromatographic method using amperometric detection was developed for the determination of naltrexone in human plasma. Prior to analysis, naltrexone and the internal standard (naloxone) were extracted from plasma samples using a 9:1 mixture of chloroform and isopropyl alcohol. The mobile phase comprised 0.1 M disodium hydrogen orthophosphate (pH 3.5) and acetonitrile (85.5:14.5, v/v). Analysis was run at a flow-rate of 0.8 ml/min with the detector operating under oxidative mode at an applied potential of +0.95 V. The method is specific and sensitive with a detection limit of approximately 1 ng/ml at a signal-to-noise ratio of 3:1. Mean recovery value of the extraction procedure was about 93%, while the within day and between day coefficient of variation and percent error values of the assay method were all less than 10%. The calibration curve was linear over a concentration range of 1.5-100 ng/ml.
    Matched MeSH terms: Sensitivity and Specificity
  8. Kirnpal-Kaur BS, Yap KL, Tan SC
    Malays J Pathol, 1997 Dec;19(2):133-6.
    PMID: 10879254
    A blocking test was incorporated into the commercial IDEIA Adenovirus test (DAKO Diagnostics Ltd., Cambridgeshire, UK) to detect false positive results when faecal specimens were tested for adenovirus antigen. Immune rabbit serum raised against pooled adenovirus particles from human faecal specimens, together with the pre-immune serum, was used. Assessment of positive showed that false positives were produced under two different conditions: when results were based on visual determination instead of a cut-off value determined from photometric reading, and when absorbance values were not immediately read at the end of the test. Under the optimum condition for reading and assessment of test results (immediate reading and photometric determination), 11% of 65 adenovirus-positive samples were checked by the blocking ELISA as false positives. The rest of the specimens showed blocking of positive absorbance values by 70 to 98%. ELISA was found to be more sensitive than immune electron microscopy on samples with lower antigen concentration.
    Matched MeSH terms: Sensitivity and Specificity
  9. Lai FM, Liam CK, Paramsothy M, George J
    Int J Tuberc Lung Dis, 1997 Dec;1(6):563-9.
    PMID: 9487455
    University Hospital, Kuala Lumpur, Malaysia.
    Matched MeSH terms: Sensitivity and Specificity
  10. Cox-Singh J, Mahayet S, Abdullah MS, Singh B
    Int J Parasitol, 1997 Dec;27(12):1575-7.
    PMID: 9467744
    Malaria remains a disease of underdeveloped and remote regions of the world. The application of polymerase chain reaction (PCR) technology to malaria epidemiology has the potential for increasing our knowledge and understanding of this disease. In order to study malaria in all geographical locations it is important that specimen collection and DNA extraction for PCR be kept simple. Here we report a method for extracting DNA from dried blood spots on filter paper which is capable of detecting one Plasmodium falciparum and two Plasmodium vivax parasites/microliter of whole blood by nested PCR without compromising the simplicity of specimen collection or DNA extraction.
    Matched MeSH terms: Sensitivity and Specificity
  11. Lam SK, Devine PL
    Clin Diagn Virol, 1998 May 1;10(1):75-81.
    PMID: 9646004
    Rapid diagnosis of dengue infection is essential to patient management and disease control. The development of a rapid (5 min) immunochromatographic test and a 2 h commercial capture enzyme linked immunosorbent assay (ELISA) for anti-dengue IgM and IgG antibodies may lead to more rapid and accurate testing in peripheral health settings and diagnostic laboratories.
    Matched MeSH terms: Sensitivity and Specificity
  12. Rohani MY, Hasnidah D, Ong KH
    Malays J Pathol, 1998 Jun;20(1):31-3.
    PMID: 10879261
    A chromatographic immunoassay cholera antigen detection kit, the Cholera Spot test, was evaluated. The test was found to be specific with a sensitivity of 10(6) cfu/ml for the direct detection of V. cholerae in simulated stool specimens and 10 cfu/ml in simulated cotton-tipped swab specimens after overnight incubation in alkaline peptone water. This enables early recognition of cholera cases and their contacts so that prevention and control measures can be promptly instituted.
    Matched MeSH terms: Sensitivity and Specificity
  13. Kah Hay Yuen, Kok Khiang Peh
    J Chromatogr B Biomed Sci Appl, 1998 Jun 12;710(1-2):243-6.
    PMID: 9686895
    A simple high-performance liquid chromatographic method using ultraviolet detection was developed for the determination of metformin in human plasma. The method entailed direct injection of the plasma sample after deproteination using perchloric acid. The mobile phase comprised 0.01 M potassium dihydrogen orthophosphate (pH 3.5) and acetonitrile (60:40, v/v). Analyses were run at a flow-rate of 1.0 ml/min with the detector operating at a detection wavelength of 234 nm. The method is specific and sensitive, with a quantification limit of approximately 60 ng/ml and a detection limit of 15 ng/ml at a signal-to-noise ratio of 3:1. The mean absolute recovery value was about 97%, while the within-day and between-day coefficient of variation and percent error values of the assay method were all less than 8%. The calibration curve was linear over a concentration range of 62.5-4000 ng/ml.
    Matched MeSH terms: Sensitivity and Specificity
  14. Abdullah BJ, Kaur H, Ng KH
    Br J Radiol, 1998 Sep;71(849):930-3.
    PMID: 10195007
    Dried fish bones from eight species of Malaysian fish were placed in an animal cadaver at four sites (tonsil, valleculae, larynx and oesophagus) and radiographed using a double and a single film-screen combination. The use of the single film-screen combination resulted in visibility of all fish bones placed in the larynx, two of which were not visible on the double film-screen combination. There was a 50% increase of the visibility of the fish bones in the oesophagus using the single film-screen combination. The difference in dose and cost between the two different film-screen combinations was not significant.
    Matched MeSH terms: Sensitivity and Specificity
  15. Ding YY, Lieu PK, Choo PWJ
    Med J Malaysia, 1998 Sep;53(3):209-16.
    PMID: 10968155
    The uroflow and pressure-flow data of 67 men aged 65 years or more were compared. At best, the uroflow study applying the Liverpool nomogram (25th percentile) and Bristol nomogram (OSD) diagnosed bladder outlet obstruction with sensitivity of 62.5% and 62.5% and specificity of 48.8% and 74.4% respectively. Using the 50th percentile of the Liverpool nomogram as the cut-off resulted in a negative predictive value of 100.0% allowing about 10% of men to have this diagnosis ruled out. We conclude that the uroflow study is inaccurate in diagnosing bladder outlet obstruction in elderly men. However, it can be used to rule out this condition in the small subset of men with maximum flow rates above the 50th percentile of the Liverpool nomogram.
    Matched MeSH terms: Sensitivity and Specificity
  16. Lee CT
    SPUMS J, 1998 Sep;28(3):125-32.
    PMID: 11542272
    The Sharpened Romberg Test (SRT) is a test of balance commonly used in Diving Medicine. Interpretation of an abnormal test can be confounded by several factors. This study was conducted to further evaluate the usefulness of the SRT. In the first part of the study, naval and civilian volunteers in a Naval Base were recruited as subjects. The SRT scores were recorded in two separate trials; once in the morning (4 attempts) and once in the evening (4 attempts) to evaluate the effect of practice on the SRT. In the second part of the study immediate pre- and post-dive scores in a group of divers were measured to evaluate: (1) the effect of decompression; (2) the effect of the normal post-dive fatigue; and (3) the vestibular effect of swaying after a boat ride. Comparisons were also made between the distributions of the SRTs of the normal subjects and those of a retrospective group of DCI patients treated at the Slark Hyperbaric Unit, Royal New Zealand Navy Hospital (RNZNH), Auckland. The SRT was found to have an early learning effect. Second attempts were significantly better than the first (p<0.001) within the same trial. However this learning effect plateaued by the third and fourth attempts. No difference was found between trials (morning and evening). There was a post-dive decline in the scores of the first attempts only (p<0.05). Subsequent second to fourth attempts were not affected by diving. The practice effect is only evident between the first and second attempts within the same trial but not between trials. The pre- and post-dive data showed that the SRT was not affected by decompression, post-dive fatigue or the vestibular sensation of swaying that is commonly experienced after a boat ride. Comparison of the distributions between controls and DCI patients showed a bimodal pattern. Fifty-four percent (54%) of the DCI patients had 'normal' scores (60 seconds), while 14% had scores between 16-35 seconds and 32% scored less than 15 seconds. In contrast, 95% of the control groups had 'normal' scores while 5% scored between 16-35 seconds. Therefore, accepting a score of less than 40 seconds as being "abnormal" will give the SRT a sensitivity of 46%, specificity of 95% and predictive value of 82%.
    Matched MeSH terms: Sensitivity and Specificity
  17. Hamilton RG, Adkinson NF
    J Allergy Clin Immunol, 1998 Sep;102(3):482-90.
    PMID: 9768592
    BACKGROUND: No characterized diagnostic natural rubber latex skin testing material is licensed for use in the United States.

    OBJECTIVE: We have conducted a multicenter clinical skin testing study to document the safety and diagnostic sensitivity and specificity of a candidate Hevea brasiliensis nonammoniated latex (NAL) extract. These data are intended to support the licensing of this reagent for the diagnosis of latex allergy in high-risk populations.

    METHODS: Three hundred twenty-four subjects (304 adults and 20 children) were classified by their clinical history as having latex allergy (LA group, 124 adults and 10 children) or having no latex allergy (NLA group, 180 adults and 10 children). All subjects provided blood samples and then received sequential puncture skin tests (PSTs) at 1, 100, or 1000 microg/mL protein with a bifurcated needle and NAL (Greer Laboratories) from Malaysian Hevea brasiliensis (clone 600) sap. A 2-stage glove provocation test was used to clarify latex allergy status of individuals with positive history/negative PST result and negative history/positive PST result mismatches.

    RESULTS: Twenty-four subjects (15%) originally designated as having LA on the basis of their initial clinical history were reclassified to the NLA group on the basis of a negative glove provocation test result. Of the 134 subjects with LA, 54 (40%) were highly sensitive to latex, with a positive PST result at 1 microg/mL NAL. The Greer NAL reagent produced a positive PST rate (sensitivity) of 95% and 99% in subjects with LA at 100 microg/mL and 1 mg/mL, respectively. The negative PST rate (specificity) in 190 subjects with a negative history with the NAL extract at 100 microg/mL and 1 mg/mL, was 100% and 96%, respectively. Immediately after the PST, mild systemic reactions (mainly pruritus) were recorded in 16.1 % of the adults in the LA group and 4.4% of the adults in the NLA group. No reactions required treatment with epinephrine. Only mild delayed reactions were observed in 9.6% (LA group) and 2.8% (NLA group) of subjects 24 to 48 hours after PST. Mean wheal and erythema diameters measured in the 10 children in the LA group with spina bifida at 100 microg/mL and 1 mg/mL were similar to those observed in the adults in the LA group, suggesting that children are not at increased risk for systemic reactions compared with adults.

    CONCLUSIONS: A suggestive clinical history is necessary but not sufficient for a definitive diagnosis of IgE-dependent latex allergy. These data support the safety and diagnostic efficacy of the Greer NAL, skin test reagent at 100 micro/mL and 1 mg/mL for confirmatory PSTs.

    Matched MeSH terms: Sensitivity and Specificity
  18. Rahmah N, Anuar AK, A'shikin AN, Lim BH, Mehdi R, Abdullah B, et al.
    Biochem Biophys Res Commun, 1998 Sep 29;250(3):586-8.
    PMID: 9784388
    Western blot analyses were performed on 444 serum specimens: 40 sera from microfilaraemic individuals, 10 sera from elephantiasis patients, 24 treated individuals, 50 sera from residents of endemic areas without anti-filarial IgG4 antibodies (endemic normals), 20 sera from amicrofilaraemic individuals with high anti-filarial IgG4 antibodies, 200 sera from healthy city-dwellers (non-endemic samples), and 100 sera from soil-transmitted helminth-infected individuals. Phast electrophoresis system was used to electrophorese Brugia malayi soluble adult worm antigen on 10-15% SDS-PAGE gradient gels followed by electrophoretic transfer onto PVDF membranes. Membrane strips were then successively incubated with blocking solution, human sera, and monoclonal anti-human IgG4 antibody-HRP, with adequate washings done in between each incubation step. Luminol chemiluminescence detection was then used to develop the blots. An antigenic band with the MW of approximately 37 kDa was found to be consistently present in the Western blots of all microfilaraemic sera, all amicrofilaraemic sera with high titres of anti-filarial IgG4 antibodies, some treated patients, and some elephantiasis patients. The antigen did not occur in immunoblots of individuals with other helminthic infections, normal endemic individuals, and city dwellers. Therefore the B. malayi antigen of with the MW of approximately 37 kDa demonstrated specific reactions with sera of B. malayi-infected individuals and thus may be useful for diagnostic application.
    Matched MeSH terms: Sensitivity and Specificity
  19. Wong CF, Peh KK, Yuen KH
    J Chromatogr B Biomed Sci Appl, 1998 Oct 23;718(1):205-10.
    PMID: 9832378
    A simple high-performance liquid chromatographic method was developed for the determination of ranitidine in human plasma. Prior to analysis, ranitidine and the internal standard (metoprolol) were extracted from alkalinized plasma samples using dichloromethane. The mobile phase was 0.05 M potassium dihydrogenphosphate-acetonitrile (88:12, v/v) adjusted to pH 6.5. Analysis was run at a flow-rate of 1.3 ml/min and at a detection wavelength of 229 nm. The method is sensitive with a detection limit of 1 ng/ml at a signal-to-noise ratio of 3:1, while the quantification limit was set at 15 ng/ml. The calibration curve was linear over a concentration range of 15-2000 ng/ml. Mean recovery value of the extraction procedure was about 90%, while the within-day and between-day coefficients of variation and percent error values of the assay method were all less than 15%.
    Matched MeSH terms: Sensitivity and Specificity
  20. Salasawati H, Ramelah M, Pitt TL, Holmes B
    PMID: 10772579
    The purpose of this investigation was to evaluate the usefulness of a co-agglutination procedure for the typing of Flavobacterium meningosepticum. The sensitivity and specificity of the co-agglutination test was compared to the slide agglutination test using reference strains of the bacterial species. Antisera were characterized by both technics to determine their titer and working dilution. The specificity of the sera was assessed by performing tests which include strains of other species and serotypes. A collection of 47 strains of F. meningosepticum isolated from clinical specimens were typed by both co-agglutination and slide agglutination methods. Co-agglutination proved to be markedly more specific than the slide procedure although both methods were similar in sensitivity. It was concluded that co-agglutination proved to be an excellent method for the serotyping of F. meningosepticum.
    Matched MeSH terms: Sensitivity and Specificity