Displaying publications 81 - 100 of 279 in total

Abstract:
Sort:
  1. Teo PC, Kassim AY, Thevarajan K
    J Orthop Surg (Hong Kong), 2013 Dec;21(3):340-6.
    PMID: 24366797
    To propose a novel method to measure the neck shaft angle and anteversion of the femur using anteroposterior and 45-degree oblique radiographs.
    Matched MeSH terms: Range of Motion, Articular
  2. Sulaiman AR, Simbak N, Wan Ismail WF, Wan Z, Halim AS
    J Orthop Surg (Hong Kong), 2011 Aug;19(2):250-3.
    PMID: 21857057
    We report 2 patients with congenital pseudoarthrosis of the tibia who underwent intramedullary Rush rod transfixation through the ankle joint following refracture and nonunion of vascularised fibular grafting 6 and 8 months earlier. After 9 and 5 years, both Rush rods were broken at the level of the ankle joints, while the reconstructed area was solidly united. The growth of the distal tibia increased the distance of the tips of the broken rod and hence the ankle joint motion. The broken tips may damage the articular cartilage and result in valgus deformity of the ankle and limb length discrepancy.
    Matched MeSH terms: Range of Motion, Articular
  3. Yong CK, Choon DS, Soon HC
    J Orthop Surg (Hong Kong), 2008 Aug;16(2):197-200.
    PMID: 18725672
    To present midterm results of Duracon total knee arthroplasty (TKA) performed between 1991 and 2001.
    Matched MeSH terms: Range of Motion, Articular
  4. Foead A, Penafort R, Saw A, Sengupta S
    J Orthop Surg (Hong Kong), 2004 Jun;12(1):76-82.
    PMID: 15237126
    To conduct a prospective randomised controlled study to compare the stability and risk of nerve injury between fractures treated by medial-lateral pin fixation and those treated by 2-lateral pin fixation.
    Matched MeSH terms: Range of Motion, Articular/physiology
  5. Arif M, Sivananthan S, Choon DS
    J Orthop Surg (Hong Kong), 2004 Jun;12(1):25-30.
    PMID: 15237118
    To report the outcome of revised total hip arthroplasty procedures involving an anterior cortical window, extensive strut allografts, and an Exeter impaction graft.
    Matched MeSH terms: Range of Motion, Articular/physiology
  6. Yin Wei CC, Haw SS, Bashir ES, Beng SL, Shanmugam R, Keong KM
    J Orthop Surg (Hong Kong), 2017 01;25(1):2309499017690656.
    PMID: 28219305 DOI: 10.1177/2309499017690656
    OBJECTIVE: To compare construct stiffness of cortical screw (CS)-rod transforaminal lumbar interbody fusion (TLIF) construct (G2) versus pedicle screw (PS)-rod TLIF construct (G1) in the standardized porcine lumbar spine.

    METHODS: Six porcine lumbar spines (L2-L5) were separated into 12 functional spine units. Bilateral total facetectomies and interlaminar decompression were performed for all specimens. Non-destructive loading to assess stiffness in lateral bending, flexion and extension as well as axial rotation was performed using a universal material testing machine.

    RESULTS: PS and CS constructs were significantly stiffer than the intact spine except in axial rotation. Using the normalized ratio to the intact spine, there is no significant difference between the stiffness of PS and CS: flexion (1.41 ± 0.27, 1.55 ± 0.32), extension (1.98 ± 0.49, 2.25 ± 0.44), right lateral flexion (1.93 ± 0.57, 1.55 ± 0.30), left lateral flexion (2.00 ± 0.73, 2.16 ± 0.20), right axial rotation (0.99 ± 0.21, 0.83 ± 0.26) and left axial rotation (0.96 ± 0.22, 0.92 ± 0.25).

    CONCLUSION: The CS-rod TLIF construct provided comparable construct stiffness to a traditional PS-rod TLIF construct in a 'standardized' porcine lumbar spine model.

    Matched MeSH terms: Range of Motion, Articular
  7. Ajit Singh V, Earnest Kunasingh D, Haseeb A, Yasin NF
    J Orthop Surg (Hong Kong), 2019 5 30;27(2):2309499019850313.
    PMID: 31138060 DOI: 10.1177/2309499019850313
    PURPOSE: Expandable endoprosthesis allows limb salvage in children with an option to leading a better life. However, the revision rate and implant-related complications impose as a limitation in the skeletal immature. This study investigates the functional outcomes and complications related to expandable endoprosthesis in our centre.

    MATERIALS AND METHODS: Twenty surviving patients with expandable endoprosthesis from 2006 till 2015 were scored using Musculoskeletal Tumour Society (MSTS) outcomes instrument and reviewed retrospectively for range of motion of respected joints, limb length discrepancy, number of surgeries performed, complications and oncological outcomes. Patients with less than 2 years of follow-up were excluded from this study.

    RESULTS: Forty-five percentage patients reached skeletal maturity with initial growing endoprosthesis and 25% of patients were revised to adult modular prosthesis. One hundred fifty-seven surgeries were performed over the 9-year period. The average MSTS score was 90.83%. The mortality rate was 10% within 5 years due to advanced disease. Infection and implant failure rate was 15% each. The event-free survival was 50% and overall survival rate was 90%.

    CONCLUSION: There is no single best option for reconstruction in skeletally immature. This study demonstrates a favourable functional and survival outcome of paediatric patients with expandable endoprosthesis. The excellent MSTS functional scores reflect that patients were satisfied and adjusted well to activities of daily living following surgery despite the complications.

    Matched MeSH terms: Range of Motion, Articular/physiology*
  8. Chiu CK, Lisitha KA, Elias DM, Yong VW, Chan CYW, Kwan MK
    J Orthop Surg (Hong Kong), 2018 10 26;26(3):2309499018806700.
    PMID: 30352524 DOI: 10.1177/2309499018806700
    BACKGROUND: This prospective clinical-radiological study was conducted to determine whether the dynamic mobility stress radiographs can predict the postoperative vertebral height restoration, kyphosis correction, and cement volume injected after vertebroplasty.

    METHODS: Patients included had the diagnosis of significant back pain caused by osteoporotic vertebral compression fracture secondary to trivial injury. All the patients underwent routine preoperative sitting lateral spine radiograph, supine stress lateral spine radiograph, and supine anteroposterior spine radiograph. The radiological parameters recorded were anterior vertebral height (AVH), middle vertebral height (MVH), posterior vertebral height (PVH), MVH level below, wedge endplate angle (WEPA), and regional kyphotic angle (RKA). The supine stress versus sitting difference (SSD) for all the above parameters were calculated.

    RESULTS: A total of 28 patients (4 males; 24 females) with the mean age of 75.6 ± 7.7 years were recruited into this study. The mean cement volume injected was 5.5 ± 1.8 ml. There was no difference between supine stress and postoperative radiographs for AVH ( p = 0.507), PVH ( p = 0.913) and WEPA ( p = 0.379). The MVH ( p = 0.026) and RKA ( p = 0.005) were significantly less in the supine stress radiographs compared to postoperative radiographs. There was significant correlation ( p < 0.05) between supine stress and postoperative AVH, MVH, PVH, WEPA, and RKA. The SSD for AVH, PVH, WEPA, and RKA did not have significant correlation with the cement volume ( p > 0.05). Only the SSD-MVH had significant correlation with cement volume, but the correlation was weak ( r = 0.39, p = 0.04).

    CONCLUSIONS: Dynamic mobility stress radiographs can predict the postoperative vertebral height restoration and kyphosis correction after vertebroplasty for thoracolumbar osteoporotic fracture with intravertebral clefts. However, it did not reliably predict the amount of cement volume injected as it was affected by other factors.

    Matched MeSH terms: Range of Motion, Articular/physiology
  9. Sun C, Zhang X, Lee WG, Tu Y, Li H, Cai X, et al.
    J Orthop Surg Res, 2020 Aug 05;15(1):297.
    PMID: 32758250 DOI: 10.1186/s13018-020-01823-2
    BACKGROUND: The infrapatellar fat pad (IPFP) or Hoffa's fat pad is often resected during total knee arthroplasty in order to improve visibility. However, the management of the IPFP during total knee arthroplasty (TKA) is the subject of an ongoing debate that has no clear consensus. The purpose of this review was to appraise if resection of the IPFP affects clinical outcomes.

    METHODS: We conducted a meta-analysis to identify relevant randomized controlled trials involving infrapatellar fat pad resection and infrapatellar fat pad preservation during total knee arthroplasty in electronic databases, including Web of Science, Embase, PubMed, Cochrane Controlled Trials Register, Cochrane Library, Highwire, CBM, CNKI, VIP, and Wanfang database, up to March 2020.

    RESULTS: Nine randomized controlled trials, involving 783 TKAs (722 patients), were included in the systematic review. Outcome measures included patellar tendon length (PTL), Insall-Salvati ratio (ISR), rate of anterior knee pain, Knee Society Scores (KSS), and knee range of motion. The meta-analysis identified a trend toward the shortening of the patellar tendon with IPFP resection at 6 months (P = 0.0001) and 1 year (P = 0.001). We found no statistical difference in ISR (P = 0.87), rate of anterior knee pain within 6 months (p = 0.45) and 1 year (p = 0.38), KSS at 1 year (p = 0.77), and knee range of motion within 6 months (p = 0.61) and 1 year (0.46).

    CONCLUSION: Based on the available level I evidence, we were unable to conclude that one surgical technique of IPFP can definitively be considered superior over the other. More adequately powered and better-designed randomized controlled trial (RCT) studies with long-term follow-up are required to produce evidence-based guidelines regarding IPFP resection.

    Matched MeSH terms: Range of Motion, Articular
  10. Sulaiman AR, Munajat I, Mohd EF
    J Pediatr Orthop B, 2011 Nov;20(6):366-71.
    PMID: 21716140 DOI: 10.1097/BPB.0b013e32834920df
    Operative treatment for neglected fracture of lateral humeral condyle (LHC) is difficult because of contracted muscle, fibrous tissue formation, and indistinct bony edges. Its success depends on the ability to preserve blood supply during the surgery. We retrospectively reviewed eight cases of neglected fracture of LHC in children treated with open reduction with selected multiple 'V' lengthening of common extensor muscle and internal fixation. The patients were between 3 and 8 years of age. The period of neglect was between 3 and 20 weeks. Four patients with displacement of more than 10 mm and neglect for 5 weeks or more required lengthening of common extensor muscle aponeurosis. The follow-up assessments were between 1 and 6.3 years with a mean of 4.4 years. All patients had union by 2 months. They gained improvement of flexion range of motion between 60° and 120° with a mean of 86.3°. Loss of final range of motion compared with the normal side was between 5° and 35° with a mean of 10°. No patient had limitation of activities or pain. Six cases had excellent and two cases had good Dillon functional score. All patients had lateral condyle prominent with different severities. There was one mild avascular necrosis and one fishtail deformity. Both of them had almost full range of motion. All patients had early physeal closure, except one, who had only 1 year follow-up. There was no case of progressive valgus deformity. Children with neglected fracture of LHC would benefit from anatomical reduction and internal fixation through a proper exposure and if indicated combined with multiple 'V' lengthening of common extensor muscle aponeurosis. This is a level IV study.
    Matched MeSH terms: Range of Motion, Articular
  11. Muhamad Effendi F, Nam Y, Shin CH, Cho TJ, Yoo WJ, Cheon JE, et al.
    J Pediatr Orthop B, 2018 Sep;27(5):407-411.
    PMID: 28704300 DOI: 10.1097/BPB.0000000000000477
    Heterotopic ossification in soft tissue or muscle is rare in the pediatric and adolescent age group. Most cases are associated with musculoskeletal injury and trauma to the central nervous system. Here, we describe an adolescent patient without a history of trauma or lesions in the central nervous system who presented with a painful limp with limited motion of the left hip. Investigations indicated unusually large heterotopic ossification extending from the inner aspect of the ilium down to the anterior part of the hip, highly likely to have developed after an unrecognized periacetabular pyomyositis primarily involving the iliacus muscle. Surgical excision was performed successfully without perioperative complications. No recurrence was detected at the final follow-up.
    Matched MeSH terms: Range of Motion, Articular
  12. Collin P, Hervé A, Walch G, Boileau P, Muniandy M, Chelli M
    J Shoulder Elbow Surg, 2019 Oct;28(10):2023-2030.
    PMID: 31405717 DOI: 10.1016/j.jse.2019.03.002
    BACKGROUND: Results of anatomic shoulder arthroplasty for glenohumeral osteoarthritis with severe glenoid retroversion are unpredictable with a high rate of glenoid loosening. Reverse shoulder arthroplasty (RSA) has been suggested as an alternative, with good early results. We sought to confirm this at longer follow-up (minimum 5 years). The study hypothesis was that early results would endure over time.

    METHODS: We retrospectively reviewed all RSAs performed in 7 centers from 1998 to 2010. The inclusion criteria were primary glenohumeral osteoarthritis with B1, B2, B3, or C glenoid. Forty-nine shoulders in 45 patients fulfilled the criteria. Bone grafting was performed in 16 cases. Clinical outcomes were evaluated with the Constant score (CS) and shoulder range of motion.

    RESULTS: The mean total CS increased from 30 preoperatively to 68 points (P < .001) with significant improvements in all the subsections of the CS and range of motion. Scapular notching was observed in 20 shoulders (43%), grade 1 in 5 (11%), grade 2 in 7 (15%), grade 3 in 5 (11%), and grade 4 in 3 (6%). The glenoid bone graft healed in all the shoulders. Partial inferior lysis of the bone graft was present in 8 cases (50%). Scapular notching and glenoid bone graft resorption had no influence on the CS (P = .147 and P = .798).

    CONCLUSION: RSA for the treatment of primary glenohumeral osteoarthritis in patients with posterior glenoid deficiency and humeral subluxation without rotator cuff insufficiency resulted in excellent clinical outcomes at a minimum of 5 years of follow-up.

    Matched MeSH terms: Range of Motion, Articular
  13. Amiri-Khorasani M, Abu Osman NA, Yusof A
    J Strength Cond Res, 2011 Jun;25(6):1647-52.
    PMID: 21358428 DOI: 10.1519/JSC.0b013e3181db9f41
    The purpose of this study was to examine the effects of static and dynamic stretching within a pre-exercise warm-up on hip dynamic range of motion (DROM) during instep kicking in professional soccer players. The kicking motions of dominant legs were captured from 18 professional adult male soccer players (height: 180.38 ± 7.34 cm; mass: 69.77 ± 9.73 kg; age: 19.22 ± 1.83 years) using 4 3-dimensional digital video cameras at 50 Hz. Hip DROM at backward, forward, and follow-through phases (instep kick phases) after different warm-up protocols consisting of static, dynamic, and no-stretching on 3 nonconsecutive test days were captured for analysis. During the backswing phase, there was no difference in DROM after the dynamic stretching compared with the static stretching relative to the no-stretching method. There was a significant difference in DROM after the dynamic stretching compared with the static stretching relative to the no-stretching method during (a) the forward phase with p < 0.03, (b) the follow-through phase with p < 0.01, and (c) all phases with p < 0.01. We concluded that professional soccer players can perform a higher DROM of the hip joint during the instep kick after dynamic stretching incorporated in warm-ups, hence increasing the chances of scoring and injury prevention during soccer games.
    Matched MeSH terms: Range of Motion, Articular/physiology*
  14. Mani S, Sharma S, Singh DK
    J Telemed Telecare, 2021 Feb;27(2):88-97.
    PMID: 31272309 DOI: 10.1177/1357633X19861802
    INTRODUCTION: The aim of this study was to determine the concurrent validity and reliability of telerehabilitation (TR)-based evaluation of the cervical spine among adults with non-specific neck pain (NS-NP).

    METHODS: A total of 11 participants with NS-NP were recruited. Pain intensity, active range of motion (AROM), posture, deep neck flexor (DNF) endurance, combined neck movements and disability were measured using face-to-face and TR methods, with a one-hour break in between. TelePTsys, an image-based TR system, was used for TR assessment.

    RESULTS: A high degree of concurrent validity for pain (bias = 0.90), posture (bias = 0.96°), endurance (bias = -2.3 seconds), disability (bias = 0.10), AROM (extension bias = -0.60 cm, flexion bias = 1.2 cm, side flexion bias = -1.00, rotation bias = -0.30 cm) was found. Standard error of measurement and coefficient of variation (CV) values were within the acceptable level for concurrent validity, except the CV for cervical flexion and endurance. There was a high degree of reliability demonstrated for pain, posture, AROM, endurance and disability measurements. The average-measure interclass correlation coefficient (ICC(3,1)) ranged from 0.96 to 0.99 for inter-rater, and 0.93 to 0.99 for intra-rater reliabilities. There was moderate agreement for combination movement for validity (78.5%, p 

    Matched MeSH terms: Range of Motion, Articular
  15. Ali Md Nadzalan
    MyJurnal
    This study was conducted to investigate i) while the shoulder was in 180° of flexion and the elbow extended, which of the forearm position (supination, pronation and neutral) can generate the greatest handgrip strength, ii) is there any correlation of the handgrip strength between the dominant hand (right hand) and non-dominant hand (left hand) in each forearm position, and iii) will the dominant hand possessed 10% higher handgrip strength than the non-dominant hand. 100 right handed sedentary active students age 22.20 years old (± 1.03), height 172.83 cm (± 6.37), body mass 68.87 (± 11.52) and grip position 3.77 (± 0.77) were recruited in this study. The result indicated that for both the dominant and non-dominant hand, when the shoulder is in 180˚ flexion of the body with the elbow extended, the greatest grip strength was obtained when the forearm was in neutral position followed by pronation and supination position. Post Hoc analysis showed that for both dominant hand and non-dominant hand, pronation and supination forearm position produced greater strength score compared to supination forearm position (p0.05). In all forearm position, participants were shown to produced significantly greater strength in their dominant hand and all the scores were more than 10% greater compared to when using non-dominant hand. Positive relationships were also found for the strength score between dominant hand and non-dominant hand. As the conclusion, different shoulder, elbow and forearm position can affect handgrip strength.
    Matched MeSH terms: Range of Motion, Articular
  16. Yin, Jerusha Chan Poe, Ashril Yusof, Victor Selvarajah Selvanayagam
    MyJurnal
    Journal of Sports Science and Physical Education 5(2): 1-8, 2016 - The objective of this
    study was to determine the number of familiarisation sessions required for isokinetic knee
    extension and flexion in female varsity athletes. Thirty right footed dominance female varsity
    athletes (n=30; age: 21.73 ±0.22 years, body mass index (BMI): 22.58 ±0.52 kg/m2), with no
    history of knee injuries were recruited. The design started with either with the dominant or
    non-dominant limb, followed by the opposite limb. Four sets of isokinetic maximal voluntary
    contraction at 60 o/s were performed for each limb. The results showed that for knee
    extension regardless of which limb starts first is 2 sessions, however for knee flexion, 3
    sessions is required for dominant limb while 2 for non-dominant. In addition, the presence of
    cross-education effect is observed for knee flexion from non-dominant to dominant limb,
    where the number of session was reduced from three to two. In conclusion, we propose that
    two sessions of familiarisation are required for female varsity athletes and should begin with the non-dominant limb followed by dominant limb.
    Matched MeSH terms: Range of Motion, Articular
  17. Fallahiarezoodar A, Abdul Kadir MR, Alizadeh M, Naveen SV, Kamarul T
    Knee Surg Sports Traumatol Arthrosc, 2014 Dec;22(12):3019-27.
    PMID: 25149643 DOI: 10.1007/s00167-014-3227-7
    PURPOSE: Reproducing the femoral rollback through specially designed mechanism in knee implants is required to achieve full knee function in total knee arthroplasty. Most contemporary implants use cam/post mechanism to replace the function of Posterior Cruciate Ligament. This study was aimed to determine the most appropriate cam and post designs to produce normal femoral rollback of the knee.

    METHODS: Three different cams (triangle, ellipse, and circle) and three different posts (straight, convex, concave) geometries were considered in this study and were analysed using kinematic analyses. Femoral rollback did not occur until reaching 50° of knee flexion. Beyond this angle, two of the nine combinations demonstrate poor knee flexion and were eliminated from the study.

    RESULTS: The combination of circle cam with concave post, straight post and convex post showed 15.6, 15.9 and 16.1 mm posterior translation of the femur, respectively. The use of ellipse cam with convex post and straight post demonstrated a 15.3 and 14.9 mm femoral rollback, whilst the combination of triangle cam with convex post and straight post showed 16.1 and 15.8 mm femoral rollback, respectively.

    CONCLUSION: The present study demonstrates that the use of circle cam and convex post created the best femoral rollback effect which in turn produces the highest amount of knee flexion. The findings of the study suggest that if the design is applied for knee implants, superior knee flexion may be possible for future patients.

    LEVEL OF EVIDENCE: IV.

    Matched MeSH terms: Range of Motion, Articular
  18. Merican AM, Ghosh KM, Baena FR, Deehan DJ, Amis AA
    Knee Surg Sports Traumatol Arthrosc, 2014 Mar;22(3):526-33.
    PMID: 23271038 DOI: 10.1007/s00167-012-2312-z
    PURPOSE: To study the effect of increasing patellar thickness (overstuffing) on patellofemoral kinematics in total knee arthroplasty and whether subsequent lateral retinacular release would restore the change in kinematics.

    METHODS: The quadriceps of eight fresh-frozen knees were loaded on a custom-made jig. Kinematic data were recorded using an optical tracking device for the native knee, following total knee arthroplasty (TKA), then with patellar thicknesses from -2 to +4 mm, during knee extension motion. Staged lateral retinacular releases were performed to examine the restoration of normal patellar kinematics.

    RESULTS: Compared to the native knee, TKA led to significant changes in patellofemoral kinematics, with significant increases in lateral shift, tilt and rotation. When patellar composite thickness was increased, the patella tilted further laterally. Lateral release partly corrected this lateral tilt but caused abnormal tibial external rotation. With complete release of the lateral retinaculum and capsule, the patella with an increased thickness of 4 mm remained more laterally tilted compared to the TKA with normal patellar thickness between 45° and 55° knee flexion and from 75° onwards. This was on average by 2.4° ± 2.9° (p 

    Matched MeSH terms: Range of Motion, Articular
  19. Yoon KH, Kim JS, Park JY, Park SY, Kiat RYD, Kim SG
    Knee Surg Sports Traumatol Arthrosc, 2021 Jun;29(6):1936-1943.
    PMID: 32914218 DOI: 10.1007/s00167-020-06266-0
    PURPOSE: To compare clinical and radiological outcomes and failure rates between anatomical and high femoral tunnels in remnant-preserving single-bundle posterior cruciate ligament (PCL) reconstruction.

    METHODS: 63 patients who underwent remnant-preserving single-bundle PCL reconstruction between 2011 and 2018 with a minimum 2-year follow-up were retrospectively reviewed. Patients were divided into two groups according to the femoral tunnel position: group A (33 patients with anatomical femoral tunnel) and group H (30 patients with high femoral tunnels). The femoral tunnel was positioned at the center (group A) or upper margin (group H) of the remnant anterolateral bundle. The position of the femoral tunnel was evaluated using the grid method on three-dimensional computed tomography. Clinical and radiological outcomes and failure rates were compared between the groups at the 2-year follow-up.

    RESULTS: The position of the femoral tunnel was significantly high in group H than in group A (87.4% ± 4.2% versus 76.1% ± 3.7%, p motion, and posterior drawer test. Radiological outcomes also showed no intergroup differences in the side-to-side differences of posterior tibial translation and osteoarthritis progression. Side-to-side difference on the Telos stress radiograph was 5.2 ± 2.9 mm in group A and 5.2 ± 2.7 mm in group H (n.s.). There were four failures in group A (12.1%) and one in group H (3.3%). The differences between the groups were not statistically significant.

    CONCLUSION: The clinical and radiological outcomes and failure rates of the high femoral tunnels were comparable with those of the anatomical femoral tunnels at the 2-year follow-up after remnant-preserving single-bundle PCL reconstruction. The findings of this study suggest that high femoral tunnels can be considered an alternative in remnant-preserving single-bundle PCL reconstruction.

    LEVEL OF EVIDENCE: III.

    Matched MeSH terms: Range of Motion, Articular
  20. Shetty P
    Lancet, 2013 May 18;381(9879):1709-10.
    PMID: 23691551
    Matched MeSH terms: Motion Pictures as Topic*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links