METHODS: Fifty digital models were scanned from the same plaster models. Arch and tooth size measurements were made by 2 operators, twice. Calibration was done on 10 sets of models and checked using the Pearson correlation coefficient. Data were analyzed by error variances, repeatability coefficient, repeated-measures analysis of variance, and Bland-Altman plots.
RESULTS: Error variances ranged between 0.001 and 0.044 mm for the digital caliper method, and between 0.002 and 0.054 mm for the 3D software method. Repeated-measures analysis of variance showed small but statistically significant differences (P <0.05) between the repeated measurements in the arch and buccolingual planes (0.011 and 0.008 mm, respectively). There were no statistically significant differences between methods and between operators. Bland-Altman plots showed that the mean biases were close to zero, and the 95% limits of agreement were within ±0.50 mm. Repeatability coefficients for all measurements were similar.
CONCLUSIONS: Measurements made on models scanned by the 3D structured-light scanner were in good agreement with those made on conventional plaster models and were, therefore, clinically acceptable.
PURPOSE: To develop 3D personalized left ventricular (LV) models and thickening assessment framework for assessing regional wall thickening dysfunction and dyssynchrony in AMI patients.
STUDY TYPE: Retrospective study, diagnostic accuracy.
SUBJECTS: Forty-four subjects consisting of 15 healthy subjects and 29 AMI patients.
FIELD STRENGTH/SEQUENCE: 1.5T/steady-state free precession cine MRI scans; LGE MRI scans.
ASSESSMENT: Quantitative thickening measurements across all cardiac phases were correlated and validated against clinical evaluation of infarct transmurality by an experienced cardiac radiologist based on the American Heart Association (AHA) 17-segment model.
STATISTICAL TEST: Nonparametric 2-k related sample-based Kruskal-Wallis test; Mann-Whitney U-test; Pearson's correlation coefficient.
RESULTS: Healthy LV wall segments undergo significant wall thickening (P 50% transmurality) underwent remarkable wall thinning during contraction (thickening index [TI] = 1.46 ± 0.26 mm) as opposed to healthy myocardium (TI = 4.01 ± 1.04 mm). For AMI patients, LV that showed signs of thinning were found to be associated with a significantly higher percentage of dyssynchrony as compared with healthy subjects (dyssynchrony index [DI] = 15.0 ± 5.0% vs. 7.5 ± 2.0%, P
METHOD: Compartmental models were fitted. The final model was determined based on the objective function value and inspection of goodness-of-fit plots. The bias and precision of parameter estimates were compared between SAEM and FOCEi using stochastic simulations and estimations. For robustness, parameters were re-estimated as the initial estimates were perturbed 100 times and resultant changes evaluated.
RESULTS: The absorption kinetics of metformin depend significantly on food status. Under the fasted state, the first-order absorption into the central compartment was preceded by zero-order infusion into the depot compartment, whereas for the fed state, the absorption into the depot was instantaneous followed by first-order absorption from depot into the central compartment. The means of relative mean estimation error (rMEE) ( ME E SAEM ME E FOCEi ) and rRMSE ( RMS E SAEM RMS E FOCEi ) were 0.48 and 0.35, respectively. All parameter estimates given by SAEM appeared to be narrowly distributed and were close to the true value used for simulation. In contrast, the distribution of estimates from FOCEi were skewed and more biased. When initial estimates were perturbed, FOCEi estimates were more biased and imprecise.
DISCUSSION: nlmixr is reliable for NLMEM. SAEM was superior to FOCEi in terms of bias and precision, and more robust against initial estimate perturbations.