Displaying publications 101 - 120 of 139 in total

Abstract:
Sort:
  1. Aslam MZ, Jeoti V, Karuppanan S, Malik AF, Iqbal A
    Sensors (Basel), 2018 May 24;18(6).
    PMID: 29882929 DOI: 10.3390/s18061687
    A Finite Element Method (FEM) simulation study is conducted, aiming to scrutinize the sensitivity of Sezawa wave mode in a multilayer AlN/SiO₂/Si Surface Acoustic Wave (SAW) sensor to low concentrations of Volatile Organic Compounds (VOCs), that is, trichloromethane, trichloroethylene, carbon tetrachloride and tetrachloroethene. A Complimentary Metal-Oxide Semiconductor (CMOS) compatible AlN/SiO₂/Si based multilayer SAW resonator structure is taken into account for this purpose. In this study, first, the influence of AlN and SiO₂ layers’ thicknesses over phase velocities and electromechanical coupling coefficients (k²) of two SAW modes (i.e., Rayleigh and Sezawa) is analyzed and the optimal thicknesses of AlN and SiO₂ layers are opted for best propagation characteristics. Next, the study is further extended to analyze the mass loading effect on resonance frequencies of SAW modes by coating a thin Polyisobutylene (PIB) polymer film over the AlN surface. Finally, the sensitivity of the two SAW modes is examined for VOCs. This study concluded that the sensitivity of Sezawa wave mode for 1 ppm of selected volatile organic gases is twice that of the Rayleigh wave mode.
    Matched MeSH terms: Finite Element Analysis
  2. Khuder T, Yunus N, Sulaiman E, Dabbagh A
    J Mech Behav Biomed Mater, 2017 11;75:97-104.
    PMID: 28709037 DOI: 10.1016/j.jmbbm.2017.06.039
    Denture fracture is a common clinical complication caused by improper material selection, design, or fabrication technique. This study aimed to investigate the effect of two attachment systems on fracture risk of the implant-overdentures (IOD) via finite element analysis (FEA), using the force distributions obtained from patients' occlusal analyses and to compare the obtained results with the clinical complications associated with these attachments. A three-dimensional jaw model comprised of the edentulous bones was constructed. Three types of mandibular prostheses including complete denture (CD) (model LCD), IOD with Locator attachment (model LID-L), and IOD with telescopic attachment (model LID-T), as well as a maxillary CD (model UCD) were assembled. The vertical occlusal forces at anterior and posterior quadrants were obtained from the patients wearing mandibular CDs or IODs. The FEA results were further compared with the mechanical failures of different prostheses observed at patient recalls. In overall, the fracture risk of mandibular prostheses was lower than the maxillary compartments. The UCD opposing LCD underwent higher strains than that opposing LID-L and LID-T, which was mostly concentrated at the anterior mid-palatal polished surface. On the other hand, LID-L showed the lowest strain, followed by LID-T, and LCD. The obtained results were consistent with the clinical complications observed in the patient recalls.
    Matched MeSH terms: Finite Element Analysis
  3. Givehchi S, Wong YH, Yeong CH, Abdullah BJJ
    Minim Invasive Ther Allied Technol, 2018 Apr;27(2):81-89.
    PMID: 28612670 DOI: 10.1080/13645706.2017.1330757
    PURPOSE: To investigate the effect of radiofrequency ablation (RFA) electrode trajectory on complete tumor ablation using computational simulation.

    MATERIAL AND METHODS: The RFA of a spherical tumor of 2.0 cm diameter along with 0.5 cm clinical safety margin was simulated using Finite Element Analysis software. A total of 86 points inside one-eighth of the tumor volume along the axial, sagittal and coronal planes were selected as the target sites for electrode-tip placement. The angle of the electrode insertion in both craniocaudal and orbital planes ranged from -90° to +90° with 30° increment. The RFA electrode was simulated to pass through the target site at different angles in combination of both craniocaudal and orbital planes before being advanced to the edge of the tumor.

    RESULTS: Complete tumor ablation was observed whenever the electrode-tip penetrated through the epicenter of the tumor regardless of the angles of electrode insertion in both craniocaudal and orbital planes. Complete tumor ablation can also be achieved by placing the electrode-tip at several optimal sites and angles.

    CONCLUSIONS: Identification of the tumor epicenter on the central slice of the axial images is essential to enhance the success rate of complete tumor ablation during RFA procedures.

    Matched MeSH terms: Finite Element Analysis
  4. AHMAD SHAHIR BIN JAMALUDIN, ABDULLAH BIN YASSIN
    Sains Malaysiana, 2013;42:1727-1733.
    Invention of milling combined laser sintering system (MLSS) is able to reduce the mould manufacturing time and improve the mould accuracy. Thus, more study is needed to increase the understanding for the laser sintered material machining characteristic to gain benefit from the invention of MLSS. This paper clarified the analysis of laser sintered material machinability with the application of Finite Element Method (FEM). Mild steel AISI1055 was applied in developing the Finite Element model in this study due to its popularity in machinability test and adequate level of data availability. 2D orthogonal cutting was employed on edge design tools with updated Lagrangian coupled thermo mechanical plane strain model. Adaptive meshing, tool edge radius and various types of friction models were assigned to obtain efficient simulations and precise cutting results. Cutting force and cutting-edge temperature estimated by Finite Element Method are validated against corresponding experimental values by previous researchers. In the study, cutting force increases when radial depth increases and lowest error acquired when the shear friction factor of 0.8 was applied. Machining simulation for laser sintered materials estimated lower cutting force compared with mild steel AISI1055 due to lower Young modulus. Higher cutting temperature estimated for machining simulation laser sintered material compared with machining simulation mild steel AISI1055 due to its low thermal conductivity.
    Matched MeSH terms: Finite Element Analysis
  5. Kwan Z, Khairu Najhan NN, Yau YH, Luximon Y, M Nor F
    Int J Numer Method Biomed Eng, 2020 11;36(11):e3390.
    PMID: 32735083 DOI: 10.1002/cnm.3390
    A realistic three-dimensional (3D) computational model of skin flap closures using Asian-like head templates from two different genders, male and female, has been developed. The current study aimed to understand the biomechanics of the local flap designs along with the effect of wound closures on the respective genders. Two Asian head templates from opposite genders were obtained to use as base models. A third-order Yeoh hyperelastic model was adapted to characterize as skin material properties. A single layer composed of combined epidermis and dermis was considered, and the models were thickened according to respective anatomical positions. Each model gender was excised with a fixed defect size which was consequently covered by three different local flap designs, namely advancement, rotation, and rhomboid flaps. Post-operative simulation presented various scenarios of skin flap closures. Rotation and rhomboid flaps demonstrated maximal tension at the apex of the flap for both genders as well as advancement flap in the female face model. However, advancement flap closure in the male face model was presented otherwise. Yet, the deformation patterns and the peak tension of the discussed flaps were consistent with conventional local flap surgery. Moreover, male face models generated higher stresses compared to the female face models with a 70.34% mean difference. Overall, the skin flap operations were executed manually, and the designed surgery model met the objectives successfully while acknowledging the study limitations. NOVELTY FILE: 3D head templates were considered to address the gap as 3D face models were uncommonly employed in understanding the biomechanics of the local flaps realistically. Most of the existing studies focus on the 2D and 3D planar geometry in their models. As gender comparison has yet to be addressed, we intended to fill this gap by exploring the stress contours of the local flap designs in different genders. Create a 3D face model from two opposite genders which is capable of simulating closure of wounds using local flaps with a focus on advancement, rotation, and rhomboid flaps.
    Matched MeSH terms: Finite Element Analysis
  6. Ng TP, R Koloor SS, Djuansjah JRP, Abdul Kadir MR
    J Mech Behav Biomed Mater, 2017 02;66:1-11.
    PMID: 27825047 DOI: 10.1016/j.jmbbm.2016.10.014
    The main failure factors of cortical bone are aging or osteoporosis, accident and high energy trauma or physiological activities. However, the mechanism of damage evolution coupled with yield criterion is considered as one of the unclear subjects in failure analysis of cortical bone materials. Therefore, this study attempts to assess the structural response and progressive failure process of cortical bone using a brittle damaged plasticity model. For this reason, several compressive tests are performed on cortical bone specimens made of bovine femur, in order to obtain the structural response and mechanical properties of the material. Complementary finite element (FE) model of the sample and test is prepared to simulate the elastic-to-damage behavior of the cortical bone using the brittle damaged plasticity model. The FE model is validated in a comparative method using the predicted and measured structural response as load-compressive displacement through simulation and experiment. FE results indicated that the compressive damage initiated and propagated at central region where maximum equivalent plastic strain is computed, which coincided with the degradation of structural compressive stiffness followed by a vast amount of strain energy dissipation. The parameter of compressive damage rate, which is a function dependent on damage parameter and the plastic strain is examined for different rates. Results show that considering a similar rate to the initial slope of the damage parameter in the experiment would give a better sense for prediction of compressive failure.
    Matched MeSH terms: Finite Element Analysis
  7. Akhbar MFA
    Comput Methods Programs Biomed, 2023 Apr;231:107361.
    PMID: 36736133 DOI: 10.1016/j.cmpb.2023.107361
    BACKGROUND AND OBJECTIVE: Conventional surgical drill bits suffer from several drawbacks, including extreme heat generation, breakage, jam, and undesired breakthrough. Understanding the impacts of drill margin on bone damage can provide insights that lay the foundation for improvement in the existing surgical drill bit. However, research on drill margins in bone drilling is lacking. This work assesses the influences of margin height and width on thermomechanical damage in bone drilling.

    METHODS: Thermomechanical damage-maximum bone temperature, osteonecrosis diameter, osteonecrosis depth, maximum thrust force, and torque-were calculated using the finite element method under various margin heights (0.05-0.25 mm) and widths (0.02-0.26 mm). The simulation results were validated with experimental tests and previous research data.

    RESULTS: The effect of margin height in increasing the maximum bone temperature, osteonecrosis diameter, and depth were at least 19.1%, 41.9%, and 59.6%, respectively. The thrust force and torque are highly sensitive to margin height. A higher margin height (0.21-0.25 mm) reduced the thrust force by 54.0% but increased drilling torque by 142.2%. The bone temperature, osteonecrosis diameter, and depth were 16.5%, 56.5%, and 81.4% lower, respectively, with increasing margin width. The minimum thrust force (11.1 N) and torque (41.9 Nmm) were produced with the highest margin width (0.26 mm). The margin height of 0.05-0.13 mm and a margin width of 0.22-0.26 produced the highest sum of weightage.

    CONCLUSIONS: A surgical drill bit with a margin height of 0.05-0.13 mm and a margin width of 0.22-0.26 mm can produce minimum thermomechanical damage in cortical bone drilling. The insights regarding the suitable ranges for margin height and width from this study could be adopted in future research devoted to optimizing the margin of the existing surgical drill bit.

    Matched MeSH terms: Finite Element Analysis
  8. Smran A, Abdullah M, Ahmad NA, Ben Yahia F, Fouda AM, Alturaiki SA, et al.
    PLoS One, 2024;19(3):e0299552.
    PMID: 38483853 DOI: 10.1371/journal.pone.0299552
    This research aimed to assess the stress distribution in lower premolars that were obturated with BioRoot RCS or AH Plus, with or without gutta percha (GP), and subjected to vertical and oblique forces. One 3D geometric model of a mandibular second premolar was created using SolidWorks software. Eight different scenarios representing different root canal filling techniques, single cone technique with GP and bulk technique with sealer only with occlusal load directions were simulated as follows: Model 1 (BioRoot RCS sealer and GP under vertical load [VL]), Model 2 (BioRoot RCS sealer and GP under oblique load [OL]), Model 3 (AH Plus sealer with GP under VL), Model 4 (AH Plus sealer with GP under OL), Model 5 (BioRoot RCS sealer in bulk under VL), Model 6 (BioRoot RCS in bulk under OL), Model 7 (AH Plus sealer in bulk under VL), and Model 8 (AH Plus sealer in bulk under OL). A static load of 200 N was applied at three occlusal contact points, with a 45° angle from lingual to buccal. The von Mises stresses in root dentin were higher in cases where AH Plus was used compared to BioRoot RCS. Furthermore, shifting the load to an oblique direction resulted in increased stress levels. Replacing GP with sealer material had no effect on the dentin maximum von Mises stress in BioRoot RCS cases. Presence of a core material resulted in lower stress in dentin for AH Plus cases, however, it did not affect the stress levels in dentin for cases filled with BioRoot RCS. Stress distribution in the dentin under oblique direction was higher regardless of sealer or technique used.
    Matched MeSH terms: Finite Element Analysis
  9. Alsabery AI, Tayebi T, Kadhim HT, Ghalambaz M, Hashim I, Chamkha AJ
    J Adv Res, 2021 May;30:63-74.
    PMID: 34026287 DOI: 10.1016/j.jare.2020.09.008
    Introduction: Mixed convection flow and heat transfer within various cavities including lid-driven walls has many engineering applications. Investigation of such a problem is important in enhancing the performance of the cooling of electric, electronic and nuclear devices and controlling the fluid flow and heat exchange of the solar thermal operations and thermal storage.

    Objectives: The main aim of this fundamental investigation is to examine the influence of a two-phase hybrid nanofluid approach on mixed convection characteristics including the consequences of varying Richardson number, number of oscillations, nanoparticle volume fraction, and dimensionless length and dimensionless position of the solid obstacle.

    Methods: The migration of composite hybrid nanoparticles due to the nano-scale forces of the Brownian motion and thermophoresis was taken into account. There is an inner block near the middle of the enclosure, which contributes toward the flow, heat, and mass transfer. The top lid cover wall of the enclosure is allowed to move which induces a mixed convection flow. The impact of the migration of hybrid nanoparticles with regard to heat transfer is also conveyed in the conservation of energy. The governing equations are molded into the non-dimensional pattern and then explained using the finite element technique. The effect of various non-dimensional parameters such as the volume fraction of nanoparticles, the wave number of walls, and the Richardson number on the heat transfer and the concentration distribution of nanoparticles are examined. Various case studies for Al2O3-Cu/water hybrid nanofluids are performed.

    Results: The results reveal that the temperature gradient could induce a notable concentration variation in the enclosure.

    Conclusion: The location of the solid block and undulation of surfaces are valuable in the control of the heat transfer and the concentration distribution of the composite nanoparticles.

    Matched MeSH terms: Finite Element Analysis
  10. Patil PG, Seow LL, Uddanwadikar R, Pau A, Ukey PD
    J Prosthet Dent, 2024 Apr;131(4):675-682.
    PMID: 35667890 DOI: 10.1016/j.prosdent.2022.04.018
    STATEMENT OF PROBLEM: The edentulous mandible is commonly treated with a 2-implant overdenture. A change in diameter of the implants may affect the biomechanical behavior of the overdenture, but information on these effects is lacking.

    PURPOSE: The purpose of this 3D finite element analysis study was to evaluate the biomechanical behavior of 2-implant mandibular overdentures (2IMO) and their individual components by using implants of different diameters.

    MATERIAL AND METHODS: A 3D mandibular model was obtained from the cone beam computed tomography (CBCT) images of a 59-year-old edentulous man, and a 3D denture model was developed from intraoral scanning files in the Mimics software program. A 3D model of different diameters of implants (2.5 mm, 3.0 mm, 3.5 mm, and 4.0 mm) with a LOCATOR attachment was developed in the Solidworks software program. Two same-sized implants were inserted in the mandibular model at 10 mm from the midline in the 3Matics software program. A vertical load of 100 N was applied on the first molar region on the right side or both sides in the ANSYS software program. The maximum von Mises stresses and strains were recorded and analyzed.

    RESULTS: Stresses within the implants decreased with an increase in diameter (from 2.5 mm to 3 mm, 3.5 mm, and 4.0 mm) of the implants. The highest stresses were observed with 2.5-mm-diameter implants (0.949 MPa under unilateral and 0.915 MPa under bilateral loading) and the lowest with Ø4-mm implants (0.710 MPa under unilateral and 0.703 MPa under bilateral loading). The strains on the implants ranged between 0.0000056 and 0.0000097, and those on the mandible ranged between 0.0000513 and 0.0000566 across all diameters of the implants without following a specific trend.

    CONCLUSIONS: In 2IMO, the stresses in the implants and mandible decreased with an increase in the diameter of the implants. The implants of lesser diameter (2.5 mm) exhibited the highest stresses and strains, and the implants of the largest diameter (4 mm) exhibited the lowest stresses and strains under unilateral and bilateral loading conditions.

    Matched MeSH terms: Finite Element Analysis
  11. Ishak MI, Kadir MR, Sulaiman E, Kasim NH
    Int J Oral Maxillofac Implants, 2013 May-Jun;28(3):e151-60.
    PMID: 23748334 DOI: 10.11607/jomi.2304
    To compare the extramaxillary approach with the widely used intrasinus approach via finite element method.
    Matched MeSH terms: Finite Element Analysis*
  12. Bajuri MN, Abdul Kadir MR, Murali MR, Kamarul T
    Med Biol Eng Comput, 2013 Feb;51(1-2):175-86.
    PMID: 23124814 DOI: 10.1007/s11517-012-0982-9
    The total replacement of wrists affected by rheumatoid arthritis (RA) has had mixed outcomes in terms of failure rates. This study was therefore conducted to analyse the biomechanics of wrist arthroplasty using recently reported implants that have shown encouraging results with the aim of providing some insights for the future development of wrist implants. A model of a healthy wrist was developed using computed tomography images from a healthy volunteer. An RA model was simulated based on all ten general characteristics of the disease. The ReMotion ™ total wrist system was then modelled to simulate total wrist arthroplasty (TWA). Finite element analysis was performed with loads simulating the static hand grip action. The results show that the RA model produced distorted patterns of stress distribution with tenfold higher contact pressure than the healthy model. For the TWA model, contact pressure was found to be approximately fivefold lower than the RA model. Compared to the healthy model, significant improvements were observed for the TWA model with minor variations in the stress distribution. In conclusion, the modelled TWA reduced contact pressure between bones but did not restore the stress distribution to the normal healthy condition.
    Matched MeSH terms: Finite Element Analysis*
  13. Banabilh SM, Rajion ZA, Samsudin AR, Singh GD
    Int J Orthod Milwaukee, 2006;17(4):17-20.
    PMID: 17256439
    Facial soft tissues are a major determinant of treatment choice. When Class I and Class II malocclusions were compared using finite-element analysis, morphologic differences were localized and quantified. This study highlights the importance of determining the timing, magnitude and direction offacial growth prior to treatment to achieve stable results.
    Matched MeSH terms: Finite Element Analysis*
  14. Baharuddin MY, Salleh ShH, Zulkifly AH, Lee MH, Noor AM, A Harris AR, et al.
    PMID: 24484753 DOI: 10.1186/1471-2474-15-30
    Minimal available information concerning hip morphology is the motivation for several researchers to study the difference between Asian and Western populations. Current use of a universal hip stem of variable size is not the best option for all femur types. This present study proposed a new design process of the cementless femoral stem using a three dimensional model which provided more information and accurate analysis compared to conventional methods.
    Matched MeSH terms: Finite Element Analysis*
  15. Makinejad MD, Abu Osman NA, Abu Bakar Wan Abas W, Bayat M
    Clinics (Sao Paulo), 2013 Sep;68(9):1180-8.
    PMID: 24141832 DOI: 10.6061/clinics/2013(09)02
    This study provides an experimental and finite element analysis of knee-joint structure during extended-knee landing based on the extracted impact force, and it numerically identifies the contact pressure, stress distribution and possibility of bone-to-bone contact when a subject lands from a safe height.
    Matched MeSH terms: Finite Element Analysis*
  16. TermehYousefi A, Bagheri S, Shahnazar S, Rahman MH, Kadri NA
    Mater Sci Eng C Mater Biol Appl, 2016 Feb;59:636-642.
    PMID: 26652417 DOI: 10.1016/j.msec.2015.10.041
    Carbon nanotubes (CNTs) are potentially ideal tips for atomic force microscopy (AFM) due to the robust mechanical properties, nanoscale diameter and also their ability to be functionalized by chemical and biological components at the tip ends. This contribution develops the idea of using CNTs as an AFM tip in computational analysis of the biological cells. The proposed software was ABAQUS 6.13 CAE/CEL provided by Dassault Systems, which is a powerful finite element (FE) tool to perform the numerical analysis and visualize the interactions between proposed tip and membrane of the cell. Finite element analysis employed for each section and displacement of the nodes located in the contact area was monitored by using an output database (ODB). Mooney-Rivlin hyperelastic model of the cell allows the simulation to obtain a new method for estimating the stiffness and spring constant of the cell. Stress and strain curve indicates the yield stress point which defines as a vertical stress and plan stress. Spring constant of the cell and the local stiffness was measured as well as the applied force of CNT-AFM tip on the contact area of the cell. This reliable integration of CNT-AFM tip process provides a new class of high performance nanoprobes for single biological cell analysis.
    Matched MeSH terms: Finite Element Analysis
  17. Moo EK, Han SK, Federico S, Sibole SC, Jinha A, Abu Osman NA, et al.
    J Biomech, 2014 Mar 21;47(5):1004-13.
    PMID: 24480705 DOI: 10.1016/j.jbiomech.2014.01.003
    Cartilage lesions change the microenvironment of cells and may accelerate cartilage degradation through catabolic responses from chondrocytes. In this study, we investigated the effects of structural integrity of the extracellular matrix (ECM) on chondrocytes by comparing the mechanics of cells surrounded by an intact ECM with cells close to a cartilage lesion using experimental and numerical methods. Experimentally, 15% nominal compression was applied to bovine cartilage tissues using a light-transmissible compression system. Target cells in the intact ECM and near lesions were imaged by dual-photon microscopy. Changes in cell morphology (N(cell)=32 for both ECM conditions) were quantified. A two-scale (tissue level and cell level) Finite Element (FE) model was also developed. A 15% nominal compression was applied to a non-linear, biphasic tissue model with the corresponding cell level models studied at different radial locations from the centre of the sample in the transient phase and at steady state. We studied the Green-Lagrange strains in the tissue and cells. Experimental and theoretical results indicated that cells near lesions deform less axially than chondrocytes in the intact ECM at steady state. However, cells near lesions experienced large tensile strains in the principal height direction, which are likely associated with non-uniform tissue radial bulging. Previous experiments showed that tensile strains of high magnitude cause an up-regulation of digestive enzyme gene expressions. Therefore, we propose that cartilage degradation near tissue lesions may be due to the large tensile strains in the principal height direction applied to cells, thus leading to an up-regulation of catabolic factors.
    Matched MeSH terms: Finite Element Analysis
  18. Oshkour AA, Abu Osman NA, Yau YH, Tarlochan F, Abas WA
    Proc Inst Mech Eng H, 2013 Jan;227(1):3-17.
    PMID: 23516951
    This study aimed to develop a three-dimensional finite element model of a functionally graded femoral prosthesis. The model consisted of a femoral prosthesis created from functionally graded materials (FGMs), cement, and femur. The hip prosthesis was composed of FGMs made of titanium alloy, chrome-cobalt, and hydroxyapatite at volume fraction gradient exponents of 0, 1, and 5, respectively. The stress was measured on the femoral prosthesis, cement, and femur. Stress on the neck of the femoral prosthesis was not sensitive to the properties of the constituent material. However, stress on the stem and cement decreased proportionally as the volume fraction gradient exponent of the FGM increased. Meanwhile, stress became uniform on the cement mantle layer. In addition, stress on the femur in the proximal part increased and a high surface area of the femoral part was involved in absorbing the stress. As such, the stress-shielding area decreased. The results obtained in this study are significant in the design and longevity of new prosthetic devices because FGMs offer the potential to achieve stress distribution that more closely resembles that of the natural bone in the femur.
    Matched MeSH terms: Finite Element Analysis
  19. Syahrom A, Abdul Kadir MR, Abdullah J, Öchsner A
    Med Biol Eng Comput, 2011 Dec;49(12):1393-403.
    PMID: 21947767 DOI: 10.1007/s11517-011-0833-0
    The relationship between microarchitecture to the failure mechanism and mechanical properties can be assessed through experimental and computational methods. In this study, both methods were utilised using bovine cadavers. Twenty four samples of cancellous bone were extracted from fresh bovine and the samples were cleaned from excessive marrow. Uniaxial compression testing was performed with displacement control. After mechanical testing, each specimen was ashed in a furnace. Four of the samples were exemplarily scanned using micro-computed tomography (μCT) and three dimensional models of the cancellous bones were reconstructed for finite element simulation. The mechanical properties and the failure modes obtained from numerical simulations were then compared to the experiments. Correlations between microarchitectural parameters to the mechanical properties and failure modes were then made. The Young's modulus correlates well with the bone volume fraction with R² = 0.615 and P value 0.013. Three different types of failure modes of cancellous bone were observed: oblique fracture (21.7%), perpendicular global fracture (47.8%), and scattered localised fracture (30.4%). However, no correlations were found between the failure modes to the morphological parameters. The percentage of error between computer predictions and the actual experimental test was from 6 to 12%. These mechanical properties and information on failure modes can be used for the development of synthetic cancellous bone.
    Matched MeSH terms: Finite Element Analysis
  20. Moo EK, Herzog W, Han SK, Abu Osman NA, Pingguan-Murphy B, Federico S
    Biomech Model Mechanobiol, 2012 Sep;11(7):983-93.
    PMID: 22234779 DOI: 10.1007/s10237-011-0367-2
    Experimental findings indicate that in-situ chondrocytes die readily following impact loading, but remain essentially unaffected at low (non-impact) strain rates. This study was aimed at identifying possible causes for cell death in impact loading by quantifying chondrocyte mechanics when cartilage was subjected to a 5% nominal tissue strain at different strain rates. Multi-scale modelling techniques were used to simulate cartilage tissue and the corresponding chondrocytes residing in the tissue. Chondrocytes were modelled by accounting for the cell membrane, pericellular matrix and pericellular capsule. The results suggest that cell deformations, cell fluid pressures and fluid flow velocity through cells are highest at the highest (impact) strain rate, but they do not reach damaging levels. Tangential strain rates of the cell membrane were highest at the highest strain rate and were observed primarily in superficial tissue cells. Since cell death following impact loading occurs primarily in superficial zone cells, we speculate that cell death in impact loading is caused by the high tangential strain rates in the membrane of superficial zone cells causing membrane rupture and loss of cell content and integrity.
    Matched MeSH terms: Finite Element Analysis
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links