Displaying publications 101 - 120 of 151 in total

Abstract:
Sort:
  1. Park SJ, Ahn JM, Kim YH, Park DW, Yun SC, Lee JY, et al.
    N Engl J Med, 2015 Mar 26;372(13):1204-12.
    PMID: 25774645 DOI: 10.1056/NEJMoa1415447
    BACKGROUND: Most trials comparing percutaneous coronary intervention (PCI) with coronary-artery bypass grafting (CABG) have not made use of second-generation drug-eluting stents.
    METHODS: We conducted a randomized noninferiority trial at 27 centers in East Asia. We planned to randomly assign 1776 patients with multivessel coronary artery disease to PCI with everolimus-eluting stents or to CABG. The primary end point was a composite of death, myocardial infarction, or target-vessel revascularization at 2 years after randomization. Event rates during longer-term follow-up were also compared between groups.
    RESULTS: After the enrollment of 880 patients (438 patients randomly assigned to the PCI group and 442 randomly assigned to the CABG group), the study was terminated early owing to slow enrollment. At 2 years, the primary end point had occurred in 11.0% of the patients in the PCI group and in 7.9% of those in the CABG group (absolute risk difference, 3.1 percentage points; 95% confidence interval [CI], -0.8 to 6.9; P=0.32 for noninferiority). At longer-term follow-up (median, 4.6 years), the primary end point had occurred in 15.3% of the patients in the PCI group and in 10.6% of those in the CABG group (hazard ratio, 1.47; 95% CI, 1.01 to 2.13; P=0.04). No significant differences were seen between the two groups in the occurrence of a composite safety end point of death, myocardial infarction, or stroke. However, the rates of any repeat revascularization and spontaneous myocardial infarction were significantly higher after PCI than after CABG.
    CONCLUSIONS: Among patients with multivessel coronary artery disease, the rate of major adverse cardiovascular events was higher among those who had undergone PCI with the use of everolimus-eluting stents than among those who had undergone CABG. (Funded by CardioVascular Research Foundation and others; BEST ClinicalTrials.gov number, NCT00997828.).
    Matched MeSH terms: Drug-Eluting Stents*
  2. Noor Khairiah AK, Mohamad Nazrulhisham MN, Hazman MN
    Med J Malaysia, 2018 12;73(6):407-409.
    PMID: 30647215
    Malignant intrathoracic disease is the commonest cause of superior vena cava (SVC) obstruction. Life threatening SVC obstruction with intense dyspnoea requires urgent treatment. SVC stenting has been developed in recent years which results in rapid relief of the obstruction. The Yconfiguration technique has been reported to provide support for all three limbs of the bifurcation to prevent restenosis. At present, there are limited reports on the use of Y-configuration stent in stent techniques for endovascular stenting in malignant SVC obstruction. We share our clinical experience of two patients who received balloon-mounted stents using this technique.
    Matched MeSH terms: Stents*
  3. Promphan W, Han Siang K, Prachasilchai P, Jarutach J, Makonkawkeyoon K, Siwaprapakorn W, et al.
    Catheter Cardiovasc Interv, 2020 09 01;96(3):E310-E316.
    PMID: 32299151 DOI: 10.1002/ccd.28892
    OBJECTIVES: To assess feasibility and early outcomes of using BeGraft Aortic stent in the treatment of aortic coarctation (CoA).

    BACKGROUND: BeGraft Aortic stent (Bentley InnoMed, Hechingen, Germany) allows large postdilation diameter up to 30 mm. With availability of lengths of 19-59 mm and lower stent profile, they can be used in native and recurrent CoA in adults and in pediatric patients.

    MATERIALS AND METHODS: This is a multicentre retrospective analysis of 12 implanted BeGraft Aortic stents in CoA between May 2017 and April 2019.

    RESULTS: Twelve patients aged 7.7-38 years (median 18.3 years) with body weight of 19.9-56 kg (median 45.5 kg). Eight patients (66%) had native juxtaductal CoA while four had recurrent CoA after previous surgical or transcatheter treatments. The stents were implanted successfully in all the patients with no serious adverse events. The length of the stents ranged from 27 to 59 mm and the implanted stent diameter varied from 12 to 18 mm. The median intraprocedural CoA pressure gradient decreased from 25 mmHg (range 16-66 mmHg) to 2 mmHg (range 0-13 mmHg). The mean follow-up duration was 10.2 months. Two patient (16.6%) had residual stent narrowing requiring staged redilation. One patient (8%) had pseudoaneurysm formation at 1 year cardiac CT follow-up.

    CONCLUSIONS: The BeGraft Aortic stent may be considered to be safe and effective in the short term in treatment of CoA from childhood to adulthood. Long-term follow-up is needed.

    Matched MeSH terms: Stents*
  4. Leong MC, Ahmed Alhassan AA, Sivalingam S, Alwi M
    Ann Thorac Surg, 2019 09;108(3):813-819.
    PMID: 30998905 DOI: 10.1016/j.athoracsur.2019.03.045
    BACKGROUND: Ductal stenting is performed to retrain involuted left ventricles (LVs) in patients with d-transposition of the great arteries and intact ventricular septum (TGA-IVS). However, its efficacy is largely unknown. This study aimed to determine the safety and efficacy of ductal stenting in retraining of the involuted LV in patients with TGA-IVS.

    METHODS: This was a single-center, retrospective study. Echocardiographic assessment of the LV geometry, mass, and free wall thickness was performed before stenting and before the arterial switch operation. Patients then underwent the arterial switch operation, and the postoperative outcomes were reviewed.

    RESULTS: There were 11 consecutive patients (male, 81.8%; mean age at stenting, 43.11 ± 18.19 days) with TGA-IVS with involuted LV who underwent LV retraining by ductal stenting from July 2013 to December 2017. Retraining by ductus stenting failed in 4 patients (36.3%). Two patients required pulmonary artery banding, and another 2 had an LV mass index of less than 35 g/m2. Patients in the successful group had improved LV mass index from 45.14 ± 17.91 to 81.86 ± 33.11g/m2 (p = 0.023) compared with 34.50 ± 10.47 to 20.50 ± 9.88 g/m2 (p = 0.169) and improved LV geometry after ductal stenting. The failed group was associated with an increased need for extracorporeal support (14.5% vs 50%, p = 0.012). An atrial septal defect-to-interatrial septum length ratio of more than 0.38 was associated with failed LV retraining.

    CONCLUSIONS: Ductal stenting is an effective method to retrain the involuted LV in TGA-IVS. A large atrial septal defect (atrial septal defect-to-interatrial septum length ratio >0.38) was associated with poor response to LV retraining.

    Matched MeSH terms: Stents*
  5. Haranal M, Mood MC, Leong MC, Febrianti Z, Abdul Latiff H, Samion H, et al.
    Interact Cardiovasc Thorac Surg, 2020 08 01;31(2):221-227.
    PMID: 32437520 DOI: 10.1093/icvts/ivaa069
    OBJECTIVES: This study aims to review our institutional experience of ductal stenting (DS) on the growth of pulmonary arteries (PAs) and surgical outcomes of PA reconstruction in this subset of patients.

    METHODS: This is a retrospective study done in neonates and infants up to 3 months of age with duct-dependent pulmonary circulation who underwent DS from January 2014 to December 2015. Post-stenting PA growth, surgical outcomes of PA reconstruction, post-surgical re-interventions, morbidity and mortality were analysed.

    RESULTS: During the study period, 46 patients underwent successful DS, of whom 38 underwent presurgery catheterization and definite surgery. There was significant growth of PAs in these patients. Biventricular repair was done in 31 patients while 7 had univentricular palliation. Left PA augmentation was required in 13 patients, and 10 required central PA augmentation during surgery. The mean follow-up period post-surgery was 4.5 ± 1.5 years. No significant postoperative complications were seen. No early or follow-up post-surgery mortality was seen. Four patients required re-interventions in the form of left PA stenting based on the echocardiography or computed tomography evidence of significant stenosis.

    CONCLUSIONS: DS provides good short-term palliation and the growth of PAs. However, a significant number of stented patients require reparative procedure on PAs at the time of surgical intervention. Acquired changes in the PAs following DS may be the reason for reintervention following PA reconstruction.

    Matched MeSH terms: Stents*
  6. Campos CM, Caixeta A, Franken M, Bartorelli AL, Whitbourn RJ, Wu CJ, et al.
    Catheter Cardiovasc Interv, 2018 02 15;91(3):387-395.
    PMID: 28471086 DOI: 10.1002/ccd.27109
    OBJECTIVES: to compare the occurrence of clinical events in diabetics treated with the Absorb bioresorbable vascular scaffold (Absorb BVS; Abbott Vascular, Santa Clara, CA) versus everolimus-eluting metal stents (EES; XIENCE V; Abbott Vascular, Santa Clara, CA) BACKGROUND: There are limited data dedicated to clinical outcomes of diabetic patients treated with bioresorbable scaffolds (BRS) at 2-year horizon.

    METHODS: The present study included 812 patients in the ABSORB EXTEND study in which a total of 215 diabetic patients were treated with Absorb BVS. In addition, 882 diabetic patients treated with EES in pooled data from the SPIRIT clinical program (SPIRIT II, SPIRIT III and SPIRIT IV trials) were used for comparison by applying propensity score matching using 29 different variables. The primary endpoint was ischemia driven major adverse cardiac events (ID-MACE), including cardiac death, myocardial infarction (MI), and ischemia driven target lesion revascularization (ID-TLR).

    RESULTS: After 2 years, the ID-MACE rate was 6.5% in the Absorb BVS vs. 8.9% in the Xience group (P = 0.40). There was no difference for MACE components or definite/probable device thrombosis (HR: 1.43 [0.24,8.58]; P = 0.69). The occurrence of MACE was not different for both diabetic status (insulin- and non-insulin-requiring diabetes) in all time points up to the 2-year follow-up for the Absorb and Xience groups.

    CONCLUSION: In this largest ever patient-level pooled comparison on the treatment of diabetic patients with BRS out to two years, individuals with diabetes treated with the Absorb BVS had a similar rate of MACE as compared with diabetics treated with the Xience EES. © 2017 Wiley Periodicals, Inc.

    Matched MeSH terms: Drug-Eluting Stents*
  7. Tan SSN, Fong AYY, Mejin M, Gerunsin J, Kong KL, Chin FYY, et al.
    Pharmacogenomics, 2017 08;18(13):1225-1239.
    PMID: 28745576 DOI: 10.2217/pgs-2017-0078
    BACKGROUND: Patients undergoing elective percutaneous coronary intervention (PCI) with drug-eluting stents (DES) who have impaired clopidogrel response, have a higher risk of subsequent major adverse cardiovascular events (MACE).

    AIM OF THE STUDY: To establish the relationship between CYP2C19 genotype, clopidogrel responsiveness and 1-year MACE.

    MATERIALS & METHODS: Aspirin/clopidogrel responses were assessed with Multiplate Analyzer and CYP2C19*2 allele by SpartanRx.

    RESULTS: A total of 42.0% carried ≥1 CYP2C19*2 allele. Prevalences of aspirin and clopidogrel high on-treatment platelet reactivity (HPR; local cutoffs: 300 AU*min for aspirin and 600 AU*min for clopidogrel) were 11.5% and 19.8% respectively. In multivariate ana-lysis, clopidogrel HPR was found to be an independent predictor for 1-year MACE (adj HR: 3.48, p = 0.022 ).

    CONCLUSION: Having clopidogrel HPR could be a potentially modifiable risk factor guided by phenotyping.

    Matched MeSH terms: Drug-Eluting Stents/adverse effects
  8. Colombo A, Chandrasekhar J, Aquino M, Ong TK, Sartori S, Baber U, et al.
    Int J Cardiol, 2019 05 15;283:67-72.
    PMID: 30826192 DOI: 10.1016/j.ijcard.2019.01.053
    BACKGROUND: The COMBO stent (OrbusNeich Medical, Ft. Lauderdale, Florida) is a new-generation bio-engineered drug eluting stent, combining an abluminal coating of a bioabsorbable polymer matrix for sustained release of sirolimus and luminal anti-CD34 coating for endothelial progenitor cell capture and rapid endothelialization.

    METHODS: The Multinational Abluminal Sirolimus Coated BiO-Engineered StenT (MASCOT) registry was a prospective post-marketing study conducted from June 2014-May 2017 across 60 centers globally. Patients were eligible if COMBO stent implantation was attempted, and they received dual antiplatelet therapy (DAPT) per local guidelines. Follow-up was conducted by trained research staff at 1, 6 and 12 months by phone or clinic visit to capture clinical events and DAPT cessation events. The primary endpoint was 1-year target lesion failure (TLF), composite of cardiac death, non-fatal myocardial infarction not clearly attributable to a non-target vessel, or ischemia-driven target lesion revascularization.

    RESULTS: A total of 2614 patients were enrolled over the study period with 96.7% completion of 1-year follow-up. The mean age of enrolled patients was 62.9 ± 11.2 years and 23.0% were female. Diabetes mellitus was present at baseline in 33.5%. A total of 56.1% patients underwent PCI for acute coronary syndrome (ACS). The 1-year primary endpoint of TLF occurred in 3.4% patients (n = 88). Definite stent thrombosis occurred in 0.5% patients (n = 12).

    CONCLUSION: The MASCOT post marketing registry provides comprehensive safety and efficacy outcomes following contemporary PCI using the novel COMBO stent in an all-comer population. This platform is associated with low rates of 1-year TLF and ST. CLINICALTRIALS.

    GOV IDENTIFIER: NCT02183454.

    Matched MeSH terms: Drug-Eluting Stents*
  9. Chandrasekhar J, Sartori S, Aquino MB, Baber U, Hájek P, Atzev B, et al.
    Am J Cardiol, 2020 07 15;127:1-8.
    PMID: 32418717 DOI: 10.1016/j.amjcard.2020.04.014
    Older patients who undergo coronary interventions are at greater risk of ischemic events and less likely to tolerate prolonged dual antiplatelet therapy (DAPT) due to bleeding risk. The COMBO biodegradable polymer sirolimus-eluting stent promotes rapid endothelialization through endothelial progenitor cell capture technology which may be advantageous in elderly patients. We compared 1-year clinical outcomes and DAPT cessation events in patients >75 versus ≤75 years from the MASCOT registry. MASCOT was a prospective, multicenter cohort study of all-comers undergoing attempted COMBO stenting. The primary endpoint was 1-year target lesion failure (TLF), composite of cardiac death, myocardial infarction (MI) not clearly attributed to a nontarget vessel or clinically driven target lesion revascularization. Bleeding was adjudicated using the Bleeding Academic Research Consortium criteria. Adjusted outcomes were analyzed using Cox regression methods. The study included 18% (n = 479) patients >75 years and 72% (n = 2,135) patients ≤75 years. One-year TLF occurred in 4.6% patients >75 years versus 3.1% patients ≤75years of age, p = 0.10; adj hazard ratio 1.36, 95% confidence intervals 0.77 to 2.38, p = 0.29. There were no significant differences in cardiac death (1.7% vs 1.3%, p = 0.55), MI (2.1% vs 1.2%, p = 0.14), target lesion revascularization (1.7% vs 1.4%, p = 0.60) and definite stent thrombosis (0.8% vs 0.4%, p = 0.19). Major Bleeding Academic Research Consortium 3,5 bleeding (3.1% vs 1.5%, p = 0.01) and DAPT cessation rates (32.4% vs 23.0%, p <0.001) were significantly higher in elderly patients. In conclusion, elderly patients >75 years treated with COMBO stents had similar TLF but significantly greater incidence of bleeding than younger patients and DAPT cessation in one-third of patients over 1 year.
    Matched MeSH terms: Drug-Eluting Stents*
  10. Loch A, Bewersdorf JP, Veeriah RS
    Indian Heart J, 2017 03 17;69(5):651-654.
    PMID: 29054192 DOI: 10.1016/j.ihj.2017.03.002
    The LEADERS FREE trial concluded that the polymer free drug-coated BioFreedom™ stent appeared to be both safer and more effective than bare-metal stents (BMS) with an ISR rate comparable to traditional DES without the need for prolonged DAPT. We implanted 45 BioFreedom™ stents in 34 patients over a 4-month period. 4 patients represented early (106-238 days after the implant procedure) with angina symptoms and severe ISR was detected in all patients. The rate of severe and early ISR detected in our patient population of 11.8% is comparable to that of traditional BMS. Further studies are warranted.
    Matched MeSH terms: Drug-Eluting Stents*
  11. Mahendran HA, Singam P, Ho C, Goh EH, Tan GH, Zuklifli MZ
    Med J Malaysia, 2012 Apr;67(2):169-72.
    PMID: 22822637 MyJurnal
    Iatrogenic ureteric injuries are rare complications of abdomino-pelvic surgery but associated with high morbidity from infection and possible loss of renal function. A successful repair is related to the timing of diagnosis, site of injury and method of repair. This study was a retrospective review of outcomes of iatrogenic ureteric injury and factors contributing to successful operative repair. Twenty consecutive cases referred to the Urology Unit of the UKM Medical Center during an 11-year period from 1998 to 2009 were reviewed. Thirteen patients were diagnosed intraoperatively and underwent immediate repair. Seven patients had delayed diagnosis but also underwent immediate repair. In our series, there was no significant difference in outcome between injuries diagnosed intraoperatively versus injuries with delayed diagnosis. There was significant difference in the outcomes between methods of ureteric repair where ureter reimplantation via psoas hitch or Boari flap yielded better results than primary end-to-end anastomosis Three patients suffered loss of renal function from unsuccessful ureter repair. We conclude that all iatrogenic ureteric injury should be repaired immediately in the absence of overt sepsis. Ureter reimplantation using a Boari flap or psoas hitch is preferred to the end-to-end anastomosis especially when there is delayed diagnosis
    Matched MeSH terms: Stents
  12. Guru K, Yahya M
    Med J Malaysia, 2011 Dec;66(5):515-6.
    PMID: 22390117 MyJurnal
    Tuberculous vasculitis is a very rare presentation of tuberculosis. So far this is the second reported case in the literature. The diagnosis of this disorder is based on the clinical presentation as well as blood investigation results. With the ever improvement in modern medicine and improvement in endovascular treatment of such diseases, the morbidity and mortality of these patients have been dramatically reduced with better clinical and survival results. We present a case of endovascular stenting of a stenotic subclavian artery with good results.
    Matched MeSH terms: Stents
  13. Harvinder S, Rosalind S, Philip R, Mallina S, Gurdeep S
    Med J Malaysia, 2008 Aug;63(3):237-8.
    PMID: 19248697 MyJurnal
    Dacrycystorhinostomy (DCR) is a procedure performed to drain the lacrimal sac in cases of nasolacrimal duct obstruction or in chronic dacryocystitis. It can be performed externally or endoscopically. This is a prospective, nonrandomized study involving twenty-two consecutive patients (16 Females and 6 Males; mean age 45.54 y; range 18-74 y) who presented to the DCR clinic with epiphora secondary to nasolacrimal duct obstruction and recurrent infection. All patients underwent primary powered endoscopic DCR. A total of 24 procedures were performed using a standardized surgical technique. Post-operatively, symptom evaluation and endoscopic assessment of the newly created lacrimal ostium were done. Twenty-two of the 24 DCR's were patent after a mean follow-up of 21.5 months, yielding a success rate of 91.66%. Patency was assessed by symptomatic evaluation and endoscopic visualization at each post-operative visit. Two patients had complications, one orbital fat exposure and the other secondary haemmorhage. The two failures were due to synechiae formation. Therefore, powered endoscopic DCR with mucosal flaps without stenting has a success rate comparable to that achieved with stents and external DCR.
    Matched MeSH terms: Stents
  14. Alwi M
    Ann Pediatr Cardiol, 2008 Jan;1(1):38-45.
    PMID: 20300236 DOI: 10.4103/0974-2069.41054
    Ductal stenting is an attractive alternative to conventional shunt surgery in duct dependent congenital heart disease as it avoids thoracotomy and its related problems. With today's generation of coronary stents which have better profile, flexibility and trackability, ductal stenting may be achieved safely and with considerably less difficulty than previously described.As in Blalock-Taussig (BT) shunt, ductal stenting is indicated mainly in duct-dependent cyanotic lesions chiefly in the neonatal period. Unlike the Patent ductus arteriosus (PDA) as an isolated lesion, the ductus in cyanotic heart disease has a remarkable morphologic variability. The ductus tends to arise more proximally under the aortic arch, giving rise to a vertical ductus or occasionally it may arise from the subclavian artery. It also tends to be long and sometimes very tortuous, rendering stent implantation technically impossible. The ductus in these patients may also insert onto one of the branch pulmonary arteries with some stenosis at the site of insertion. The ductus in Tetralogy of Fallot with pulmonary atresia (TOF-PA) tend to exhibit these morphologic features and to a lesser degree in transposition of great arteries with ventricular septal defect and pulmonary atresia (TGA-VSD-PA) and the more complex forms of univentricular hearts. In the preliminary angiographic evaluation, it is important to delineate these morphologic features as the basis for case selection.Ductal stenting may be done by the retrograde femoral artery route or the antegrade transvenous route depending on the ductus morphology and the underlying cardiac lesion. The detailed techniques and essential hardware are described. Finally, major potential complications of the procedure are described. Acute stent thrombosis is the most serious and potentially catastrophic. Emergent treatment with thrombolytic therapy and mechanical disruption of thrombus are required. With proper case selection, appropriate technique and the right hardware ductal stenting provides reasonable short-medium term palliation in duct-dependent cyanotic heart disease.
    Matched MeSH terms: Stents
  15. Gul YA, Prasannan S, Hairuszah I
    Acta Chir. Belg., 2003 Aug;103(4):420-2.
    PMID: 14524166
    Primary malignant melanoma arising in the oesophagus is a rare condition with a dismal prognosis. The diagnosis is often made following surgical resection even though the endoscopic features may be pathognomonic. The classical treatment is oesophagectomy even though the advanced disease stage at the time of presentation and aggressive biological behaviour of the tumour usually results in a fatal outcome. We report the case of a male patient initially diagnosed with squamous oesophageal carcinoma and treated with conventional neo-adjuvant chemo-radiotherapy. Poor clinical and radiological response resulted in a review of the original histology confirming a diagnosis of primary malignant melanoma of the oesophagus. The subsequent alteration in management conferred the patient an improved quality of life. A short review of the literature on primary malignant melanoma of the oesophagus supplements this case report.
    Matched MeSH terms: Stents
  16. Tan SY, Md Din N, Mohd Khialdin S, Wan Abdul Halim WH, Tang SF
    Cureus, 2021 Feb 12;13(2):e13320.
    PMID: 33738163 DOI: 10.7759/cureus.13320
    The hazy corneal donor-recipient interface after corneal transplant may cause difficulties when implanting the XEN gel stent via ab-interno approach. We aim to describe XEN gel stent implantation via ab-externo approach in refractory steroid-induced glaucoma after corneal lamellar keratoplasty. Under local anaesthesia, the XEN injector needle was inserted 7 mm behind the limbus with the bevel facing up, directly beneath the conjunctiva and advanced to the marked 2.5 mm scleral entry wound. The needle then pierced the sclera until the needle tip was just visible in the anterior chamber (AC). The slider was pushed until the tip of the XEN stent was seen in the AC. The needle was slowly withdrawn while still pushing the slider to complete stent deployment. Subconjunctival Mitomycin C 0.01% (30 µg/0.3 mL) was then injected posterior to the bleb. Three eyes of three patients with steroid-induced glaucoma after lamellar keratoplasty underwent XEN gel stent implantation via ab-externo approach placed at the superotemporal quadrant. Pre-operatively, all patients had uncontrolled IOP between 30-45 mmHg despite maximum medications and selective laser trabeculoplasty. After XEN gel stent implantation, IOP ranged between 10-17 mmHg with one or two topical antiglaucoma at 12 months. Complications include hypotony maculopathy, stent migration and hyphaema, all of which were successfully managed. Corneal graft remained clear at 12 months. XEN gel stent implantation via ab-externo approach is able to achieve good intraocular pressure (IOP) control without compromising cornea graft in patients with steroid-induced glaucoma after lamellar keratoplasty at 12 months.
    Matched MeSH terms: Stents
  17. Sunil SP, Aimanan K, Ismazizi Z
    Med J Malaysia, 2021 03;76(2):270-272.
    PMID: 33742645
    Iliac aneurysms are rare in children, especially mycotic aneurysms. Re-vascularization is challenging given the infected field and concern on patency due to their growth potential and a longer life-span. We report a complex case of a mycotic iliac aneurysm in a child. A 12-years-old boy with a previous history of infective endocarditis was referred to us for a right common iliac mycotic aneurysm after presenting with pain. A balloon-expandable stent-graft was deployed across the aneurysm during the acute presentation. He improved post-operatively, but developed abdominal pain four weeks later. A repeat computed tomography (CT) imaging showed a new inflammation of the appendix which was adhered to the calcified wall of the aneurysm and an endoleak from the internal iliac artery. A laparotomy was performed and the right internal iliac artery ligated along with an appendicectomy and omental pedicle. Postoperatively the patient was well and discharged home. Six-month surveillance revealed a healthy child and imaging showed a patent stent-graft and no residual collection.
    Matched MeSH terms: Stents
  18. Shu Ann Hon, Jan Jan Chai, Lian Thai Lee, Qin Jian Low
    MyJurnal

    A 49-year-old gentleman presented with epigastric pain for one day associated with one episode of vomiting and dyspnoea. Respiratory examination showed reduced breath sound over his left lower zone. He was treated as left spontaneous pneumothorax and left lung empyema requiring left chest tube insertion and intravenous antibiotics. His left pleural fluid biochemistry result was exudative while its centrifuge showed empyema. In ward, we noticed food material draining from his left chest tube during feeding. An urgent contrast enhanced computed tomography (CECT) thorax showed a left oesophageal-pleural fistula with possible broncho-oesophageal fistula. During oesoph- agogastroduodenoscopy (OGDS), air bubbles were seen in his left under-water chest drainage during air-insufflation of the oesophagus. The revised diagnosis was Boerhaave syndrome. He was treated with an esophageal stent to cover the perforation and a left lung decortication via video assisted thoracoscopic surgery (VATS) for his left empyema. He improved and was discharged well.
    Matched MeSH terms: Stents
  19. Krishna Moorthy PS, Saat SA, Sakijan AS
    Med J Malaysia, 2019 02;74(1):94-96.
    PMID: 30846673
    This is a case report of single-stage total thoracic aortic repair by the frozen elephant trunk technique for a 75-yearold female with a complex aortic pathology of mega-aorta extending from the ascending aorta to the descending aorta. We used a Thora flex™ Hybrid device, a frozen elephant trunk device with four branched grafts and the distal stent graft. The distal stent graft was inserted into the downstream descending aorta via an aortic arch and positioned 15 cm beyond the left subclavian artery after total arch replacement had been performed using a four-branch graft. The postoperative course was unremarkable with no complications. A post procedural computed tomography scan demonstrated complete exclusion of the descending thoracic aneurysm without endoleak. Therefore, fixing the whole mega-aorta in a single stage using the frozen elephant trunk was effective and safe.
    Matched MeSH terms: Stents