Displaying publications 121 - 140 of 150 in total

Abstract:
Sort:
  1. Khoo LS, Lai PS, Saidin MH, Noor Z, Mahmood MS
    Forensic Sci Int, 2018 Jul;288:242-255.
    PMID: 29783180 DOI: 10.1016/j.forsciint.2018.04.017
    Cadaver body bags are the conventional method to contain a human body or human remains, which includes the use for storage and transportation of the deceased at any crime scene or disaster scene. During disasters, most often than not, the first responders including the police will be equipped with cadaver body bags to do scene processing of human remains and collection of personal belongings at the disaster site. However, in an unanticipated large scale disasters involving hundreds and thousands of fatalities, cadaver body bags supplies may be scarce. The authors have therefore innovated the cling film plastic wrap as an alternative for the cadaver body bag used at the disaster site. The plastic wrap was tested on six different experimental subjects, i.e. both adult and child mannequins; body parts of the mannequin figure (arm and hand); a human adult subject and an unknown dead body. The strengths of the cling film plastic wrap are discussed in comparison with the cadaver body bag in the aspects of costing, weight, duration of the wrap, water and body fluid resistant properties, visibility and other advantages. An average savings of more than 5000% are noted for both adult body wrap and child body wrap compared to the cadaver body wrap. This simply means that the authors can either wrap 25 adult dead bodies or 80 children dead bodies with the cost of 1 cadaver body bag. The cling film plastic wrap has proven to have significant innovation impact for dead body management particularly by the first responders in large scale disasters. With proper handling of dead bodies, first responders can manage the dead with dignity and respect in an overwhelmed situation to facilitate the humanitarian victim identification process later.
    Matched MeSH terms: Cadaver
  2. Khoo LS, Lai PS, Saidin MH, Noor Z, Mahmood MS
    Forensic Sci Int, 2018 Apr;285:50-57.
    PMID: 29433011 DOI: 10.1016/j.forsciint.2018.01.018
    Cadaver body bags are the conventional method to contain a human body or human remains, which includes the use for storage and transportation of the deceased at any crime scene or disaster scene. During disasters, most often than not, the first responders including the police will be equipped with cadaver body bags to do scene processing of human remains and collection of personal belongings at the disaster site. However, in an unanticipated large scale disasters involving hundreds and thousands of fatalities, cadaver body bags supplies may be scarce. The authors have therefore innovated the cling film plastic wrap as an alternative for the cadaver body bag used at the disaster site. The plastic wrap was tested on six different experimental subjects, i.e. both adult and child mannequins; body parts of the mannequin figure (arm and hand); a human adult subject and an unknown dead body. The strengths of the cling film plastic wrap are discussed in comparison with the cadaver body bag in the aspects of costing, weight, duration of the wrap, water and body fluid resistant properties, visibility and other advantages. An average savings of more than 5000% are noted for both adult body wrap and child body wrap compared to the cadaver body wrap. This simply means that the authors can either wrap 25 adult dead bodies or 80 children dead bodies with the cost of 1 cadaver body bag. The cling film plastic wrap has proven to have significant innovation impact for dead body management particularly by the first responders in large scale disasters. With proper handling of dead bodies, first responders can manage the dead with dignity and respect in an overwhelmed situation to facilitate the humanitarian victim identification process later.
    Matched MeSH terms: Cadaver*
  3. Khan AA, Asari MA, Pasha MA
    Folia Morphol (Warsz), 2015 12 29;75(3):306-310.
    PMID: 26711654 DOI: 10.5603/FM.a2015.0130
    Variations of the sciatic nerve have been extensively studied in the past including its relationship with the piriformis muscle and associated clinical conditions like piriformis syndrome and sciatica. In the present study we noticed some interesting variations of the sciatic nerve, which were slightly different from the cases described earlier. In the previous studies most of the authors described the higher division of sciatic nerve and none of them discussed its formation. In this study we tried to look its formation from the sacral plexus and its divisions in the thigh. We noticed that in one cadaver the two components of the sciatic nerve originated directly from the sacral plexus and coursed down without merging in the thigh. Should this be called a higher division or non formation of the sciatic nerve? On the other hand in two other cadavers, the two divisions after emerging separately from the sacral plexus, united in the gluteal region and in the thigh respectively. Should we call this as higher division or low formation of the sciatic nerve? In two other cadavers the sciatic nerve emerged from the greater sciatic foramen below the piriformis and divided in the gluteal region itself. Ideally this should be called as higher division of sciatic nerve.
    Matched MeSH terms: Cadaver
  4. Khan AA, Asari MA, Hassan A, Aiman N
    Folia Morphol (Warsz), 2013 Feb;72(1):82-5.
    PMID: 23749717
    Anatomical variations in the femoral vein are of great clinical importance especially in cases of deep vein thrombosis (DVT). Knowledge of the variable anatomy of the femoral vein is important to minimise false-negative findings on ultrasound examination in patients with DVT and help to explain the 'silent' DVT. Furthermore, the presence of a duplicated femoral vein itself is associated with higher incidence of DVT. These venous anomalies are usually due to the truncular venous malformation. In the present study, while dissecting the right lower limb, we found a case of variation of the femoral vein. In this case, besides a duplicated femoral vein, we also noticed a 3rd interconnecting channel near the apex of the femoral triangle joining the two veins. This variation has not been reported previously by other authors. Considering its uniqueness and clinical importance, we decided to report this case.
    Matched MeSH terms: Cadaver
  5. Mat Taib CN, Hassan SN, Esa N, Mohd Moklas MA, San AA
    Folia Morphol (Warsz), 2016 09 26;76(1):38-43.
    PMID: 27665953 DOI: 10.5603/FM.a2016.0045
    Formation, distribution and possible communication of the median nerve are essential to know in treatment and surgeries of various conditions of injuries e.g. repair or reconstruction of the median nerve post traumatic accident. In the present study, 44 upper limbs were dissected. Root forming the median nerve, the median nerve in relation with the axillary artery and communication of the median nerve with other nerves were noted.
    Matched MeSH terms: Cadaver
  6. Heo CC, Teel PD, OConnor BM, Tomberlin JK
    Exp Appl Acarol, 2021 Dec;85(2-4):223-246.
    PMID: 34762225 DOI: 10.1007/s10493-021-00676-6
    Acari community structure and function associated with delayed pig carrion decomposition has not been examined. In this study, 18 swine carcasses were studied in central Texas, USA, during two consecutive summers (2013 and 2014). Samples of ca. 400 g soil were collected from beneath, aside, and 5 m away from each pig carcass over 180 days. Mites from soil samples were extracted using Berlese funnels and identified to order and family levels and classified according to ecological function. In total 1565 and 1740 mites were identified from the 2013 and 2014 soil samples, respectively. Significant differences were determined for mite community structure at order and family levels temporally on carrion (e.g., day 0 × day 14) regardless of treatments and between soil regions where mites were collected (e.g., soil beneath vs. soil 5 m away from carrion). However, no significant differences were found in mite community structure at the order level between pig carrion with and without delayed Diptera colonization (i.e., treatments). Analysis at the family level determined a significant difference across treatments for both summers. Ecological function of mites did not change significantly following the delayed decomposition of pig carcasses. However, detritivores and fungivores were significant indicator groups during the pig carrion decomposition process. Furthermore, 13 phoretic mite species associated with eight forensically important beetle species were documented. Data from this study indicated that the rate of nutrient flow into the soil impacted associated arthropod communities; however, detecting such shifts depends on the taxonomic resolution being applied.
    Matched MeSH terms: Cadaver
  7. Chan CY, Kwan MK, Saw LB
    Eur Spine J, 2010 Jan;19(1):78-84.
    PMID: 19763636 DOI: 10.1007/s00586-009-1157-8
    The objective of this cadaveric study is to determine the safety and outcome of thoracic pedicle screw placement in Asians using the funnel technique. Pedicle screws have superior biomechanical as well as clinical data when compared to other methods of instrumentation. However, misplacement in the thoracic spine can result in major neurological implications. There is great variability of the thoracic pedicle morphometry between the Western and the Asian population. The feasibility of thoracic pedicle screw insertion in Asians has not been fully elucidated yet. A pre-insertion radiograph was performed and surgeons were blinded to the morphometry of the thoracic pedicles. 240 pedicle screws were inserted in ten Asian cadavers from T1 to T12 using the funnel technique. 5.0 mm screws were used from T1 to T6 while 6.0 mm screws were used from T7 to T12. Perforations were detected by direct visualization via a wide laminectomy. The narrowest pedicles are found between T3 and T6. T5 pedicle width is smallest measuring 4.1 +/- 1.3 mm. There were 24 (10.0%) Grade 1 perforations and only 1 (0.4%) Grade 2 perforation. Grade 2 or worse perforation is considered significant perforation which would threaten the neural structures. There were twice as many lateral and inferior perforations compared to medial perforations. 48.0% of the perforations occurred at T1, T2 and T3 pedicles. Pedicle fracture occurred in 10.4% of pedicles. Intra-operatively, the absence of funnel was found in 24.5% of pedicles. In conclusion, thoracic pedicle screws using 5.0 mm at T1-T6 and 6.0 mm at T7-T12 can be inserted safely in Asian cadavers using the funnel technique despite having smaller thoracic pedicle morphometry.
    Matched MeSH terms: Cadaver
  8. Naveen K, Jyothsna P, Nayak SB, Mohandas RK, Swamy RS, Deepthinath R, et al.
    Ethiop J Health Sci, 2014 Jan;24(1):93-6.
    PMID: 24591805
    BACKGROUND: Axillary artery is known to show different variations mostly in its branching pattern. Similarly, the origin of profunda brachii is often encountered with abnormality. Therefore, when the vascular variations in the upper limb persist, mostly it is confined to its branching pattern followed by its variant origin. But, among all the reported variations of profunda brachii, its variant origin from the 3rd part of the axillary artery with common trunk for the branches of axillary artery is unique.

    CASE DETAILS: We report here an anomalous origin of profunda brachii as continuation of an arterial trunk arising from 3rd part of the axillary artery. This common trunk at its commencement passed between 2 roots of median nerve and gave branches of 3rd part of axillary artery before it continued as profunda brachii artery. The further course and branching pattern of profunda brachii were normal.

    CONCLUSION: Since the axillary artery is next choice of artery for arterial cannulation in cardiopulmonary bypass procedures, prior knowledge of existence of such variation in its branching pattern helps in avoiding possible diagnostic or interventional therapeutic errors.

    Matched MeSH terms: Cadaver
  9. Ashfaq Akram, Muhammad Zahedi Daud, Md Gapar Md Joha, Rizwan Farzana, Rahmatullah Khan
    MyJurnal
    Due to cost containment considerations, it is common to have medical schools being
    located in buildings or campuses built for some other purposes. These buildings are converted into
    medical schools which often compromising the functional architectural aspects. Objectives: The
    paper examines, explores and proposes an architectural concept of a purpose-built medical school. The
    architectural design proposed is sensitive to the values and norms of many schools around the globe.
    Methods: An Internet search and personal communication were conducted, focusing on the concepts
    of the functionality of medical school. It emphasises on general design of the main building, keeping
    in mind the various kinds of teaching, learning and assessment activities. We examined lecture hall,
    pre-clinical laboratory, skill laboratory, general facilities of Objective Structured Practical Examination
    (OSPE) and Objective Structured Clinical Examination (OSCE). Results: We present hypothetical
    structural designs based on built-functions concepts. For example, for the better vision of students
    around a demonstration table, an inclined floor surface is proposed. The concept is as illustrated by
    anatomy dissection area built inclined upward from the cadaver table. It inevitably provides a better
    visual access to the students around the table. Other teaching and learning areas are also illustrated
    wherever appropriate in the text. Conclusion: The paper is hypothetical and explores innovative
    structural designs of modern medical schools. While most are built to meet the demands of current
    technology, it cannot however completely replace face-to-face teaching and learning processes.
    Research in architectural designs of education buildings and facilities may be further developed into a
    new research niche of medical education.
    Matched MeSH terms: Cadaver
  10. Nair RS, Nair S
    Curr Drug Deliv, 2015;12(5):517-23.
    PMID: 25675336
    Mortality rate due to heart diseases increases dramatically with age. Captopril is an angiotensin converting enzyme inhibitor (ACE) used effectively for the management of hypertension. Due to short elimination half-life of captopril the oral dose is very high. Captopril is prone to oxidation and it has been reported that the oxidation rate of captopril in skin tissues is considerably low when compared to intestinal tissues. All these factors make captopril an ideal drug candidate for transdermal delivery. In this research work an effort was made to formulate transdermal films of captopril by utilizing polyvinylpyrrolidone (PVP) and polyvinyl alcohol (PVA) as film formers and polyethylene glycol 400 (PEG400) as a plasticizer. Dimethyl sulfoxide (DMSO) and dimethylformamide (DMF) were used as permeation enhancers. Physicochemical parameters of the films such as appearance, thickness, weight variation and drug content were evaluated. The invitro permeation studies were carried out through excised human cadaver skin using Franz diffusion cells. The in-vitro permeation studies demonstrated that the film (P4) having the polymer ratio (PVP:PVA = 80:20) with DMSO (10%) resulted a promising drug release of 79.58% at 24 hours with a flux of 70.0 µg/cm(2)/hr. No signs of erythema or oedema were observed on the rabbit skin as a result of skin irritation study by Draize test. Based on the stability report it was confirmed that the films were physically and chemically stable, hence the prepared films are very well suited for transdermal application.
    Matched MeSH terms: Cadaver
  11. Wong LP
    Clin Transplant, 2011 Jan-Feb;25(1):E22-31.
    PMID: 20718827 DOI: 10.1111/j.1399-0012.2010.01312.x
    Malaysia's organ and tissue donation rates are among the lowest in the world. The study aims to explore the knowledge, attitudes, practices and behaviors regarding deceased organ donation and transplantation in the diverse ethnic communities in the state of Selangor, Malaysia.
    Matched MeSH terms: Cadaver
  12. Kwan MK, Chan CY, Saw LB, Rukmanikanthan S, Lenke LG
    Clin Spine Surg, 2017 04;30(3):E297-E304.
    PMID: 28323715 DOI: 10.1097/BSD.0b013e3182aab29d
    STUDY DESIGN: Cadaveric and biomechanical study.

    OBJECTIVE: The aim of this study was to assess the safety and pullout strength of medial, partial nonthreaded thoracic pedicle screws compared with conventional screws.

    SUMMARY OF BACKGROUND DATA: The perforation rate of the pedicle screws has been reported as high as 41%. Nerve injury and irritation can result from the compression of malpositioned screw on neural structures.

    METHODS: Ten fresh cadavers were studied. Screws, 5.0 and 6.0 mm, were inserted from T1 to T6 and T7 to T12, respectively. Pedicle perforations and fractures were recorded upon screw insertion and final positioning (nonthreaded portion facing medially) after a wide laminectomy. Pullout strength of novel and conventional screws were then tested using an Instron machine in an artificial bone substitute.

    RESULTS: A total of 240 thoracic pedicle screws were inserted. Of them, 88.8% (213 screws) were fully contained during screw insertion. There were 5.0% (12 screws) grade 1 medial perforations and 6.2% (15 screws) grade 1 lateral perforations during screw insertion. Upon final positioning, 93.8% (225 screws) were fully contained. All grade 1 medial perforations, which occurred during insertion, were converted to grade 0. No dural or nerve root injuries occurred. Pedicle split fractures were noted in 6.7% (16 screws). The use of medial, partial nonthreaded screws reduced the overall perforation rate from 11.2% to 6.2%. The mean pullout load for the 5 mm fully threaded screw versus medial, partial nonthreaded was 1419.3±106.1 N (1275.8-1538.8 N) and 1336.6±44.2 N (1293.0-1405.1 N) respectively, whereas 6 mm pullout load averaged 2126.0±134.8 N (1986.3-2338.3 N) and 2036.5±210.0 N (1818.4-2355.9 N). The difference was not statistically significant.

    CONCLUSIONS: The use of medial, partial nonthreaded pedicle screws reduced the medial perforation rate from 5.0% to 0%; however, the pullout strength was not significantly reduced. The use of this novel screw can potentially reduce the incidence of nerve injury or irritation after medial pedicle perforations.

    Matched MeSH terms: Cadaver
  13. Yang Harmony TC, Yusof N, Ramalingam S, Baharin R, Syahrom A, Mansor A
    Clin Orthop Relat Res, 2022 Feb 01;480(2):407-418.
    PMID: 34491235 DOI: 10.1097/CORR.0000000000001968
    BACKGROUND: Gamma irradiation, which minimizes the risk of infectious disease transmission when human bone allograft is used, has been found to negatively affect its biomechanical properties. However, in those studies, the deep-freezing temperature during irradiation was not necessarily maintained during transportation and sterilization, which may have affected the findings. Prior reports have also suggested that controlled deep freezing may mitigate the detrimental effects of irradiation on the mechanical properties of bone allograft.

    QUESTION/PURPOSE: Does a controlled deep-freezing temperature during irradiation help preserve the compressive mechanical properties of human femoral cortical bone allografts?

    METHODS: Cortical bone cube samples, each measuring 64 mm3, were cut from the mid-diaphyseal midshaft of five fresh-frozen cadaver femurs (four male donors, mean [range] age at procurement 42 years [42 to 43]) and were allocated via block randomization into one of three experimental groups (with equal numbers of samples from each donor allocated into each group). Each experimental group consisted of 20 bone cube samples. Samples irradiated in dry ice were subjected to irradiation doses ranging from 26.7 kGy to 27.1 kGy (mean 26.9 kGy) at a deep-freezing temperature below -40°C (the recommended long-term storage temperature for allografts). Samples irradiated in gel ice underwent irradiation doses ranging from 26.2 kGy and 26.4 kGy (mean 26.3 kGy) in a freezing temperature range between -40°C and 0°C. Acting as controls, samples in a third group were not subjected to gamma irradiation. The mechanical properties (0.2% offset yield stress, ultimate compression stress, toughness, and the Young modulus) of samples from each group were subsequently evaluated via axial compression loading to failure along the long axis of the bone. The investigators were blinded to sample group during compression testing.

    RESULTS: The mean ultimate compression stress (84 ± 27 MPa versus 119 ± 31 MPa, mean difference 35 [95% CI 9 to 60]; p = 0.005) and toughness (3622 ± 1720 kJ/m3 versus 5854 ± 2900 kJ/m3, mean difference 2232 [95% CI 70 to 4394]; p = 0.009) of samples irradiated at a higher temperature range (-40°C to 0°C) were lower than in those irradiated at deep-freezing temperatures (below -40°C). The mean 0.2% offset yield stress (73 ± 28 MPa versus 109 ± 38 MPa, mean difference 36 [95% CI 11 to 60]; p = 0.002) and ultimate compression stress (84 ± 27 MPa versus 128 ± 40 MPa, mean difference 44 [95% CI 17 to 69]; p < 0.001) of samples irradiated at a higher temperature range (-40°C to 0°C) were lower than the nonirradiated control group samples. The mean 0.2% offset yield stress (73 ± 28 MPa versus 101 ± 28 MPa, mean difference 28 [95% CI 3 to 52]; p = 0.02; effect size = 1.0 [95% CI 0.8 to 1.2]) of samples irradiated at higher temperature range (-40°C to 0°C) were no different with the numbers available to those irradiated at deep-freezing temperature. The mean toughness (3622 ± 1720 kJ/m3 versus 6231 ± 3410 kJ/m3, mean difference 2609 [95% CI 447 to 4771]; p = 0.02; effect size = 1.0 [95% CI 0.8 to 1.2]) of samples irradiated at higher temperature range (-40°C to 0°C) were no different with the numbers available to the non-irradiated control group samples. The mean 0.2% offset yield stress, ultimate compression stress, and toughness of samples irradiated in deep-freezing temperatures (below -40°C) were not different with the numbers available to the non-irradiated control group samples. The Young modulus was not different with the numbers available among the three groups.

    CONCLUSION: In this study, maintenance of a deep-freezing temperature below -40°C, using dry ice as a cooling agent, consistently mitigated the adverse effects of irradiation on the monotonic-compression mechanical properties of human cortical bone tissue. Preserving the mechanical properties of a cortical allograft, when irradiated in a deep-freezing temperature, may have resulted from attenuation of the deleterious, indirect effects of gamma radiation on its collagen architecture in a frozen state. Immobilization of water molecules in this state prevents radiolysis and the subsequent generation of free radicals. This hypothesis was supported by an apparent loss of the protective effect when a range of higher freezing temperatures was used during irradiation.

    CLINICAL RELEVANCE: Deep-freezing temperatures below -40°C during gamma irradiation may be a promising approach to better retain the native mechanical properties of cortical bone allografts. A further study of the effect of deep-freezing during gamma radiation sterilization on sterility and other important biomechanical properties of cortical bone (such as, tensile strength, fracture toughness, and fatigue) is needed to confirm these findings.

    Matched MeSH terms: Cadaver
  14. Shanmugam R, Ernst M, Stoffel K, Fischer MF, Wahl D, Richards RG, et al.
    Clin Biomech (Bristol, Avon), 2015 Jun;30(5):405-10.
    PMID: 25846324 DOI: 10.1016/j.clinbiomech.2015.03.019
    Dorsal plating is commonly used in proximal phalanx fractures but it bears the risk of interfering with the extensor apparatus. In this study, dorsal and lateral plating fixation methods are compared to assess biomechanical differences using conventional 1.5mm non-locking plates and novel 1.3mm lateral locking plates.
    Matched MeSH terms: Cadaver
  15. Rao KG, Bhat MS
    Clin Anat, 2006 Nov;19(8):724-5.
    PMID: 16944500
    Matched MeSH terms: Cadaver
  16. Ariffin AF, Yusof N, Mohd S, Rahman SA, Ramalingam S, Mansor A, et al.
    Cell Tissue Bank, 2019 Dec;20(4):527-534.
    PMID: 31456097 DOI: 10.1007/s10561-019-09785-4
    Calcium contents of demineralised human cortical bone determined by titrimetric assay and atomic absorption spectrophotometry technique were verified by comparing to neutron activation analysis which has high recovery of more than 90%. Conversion factors determined from the comparison is necessary to correct the calcium content for each technique. Femurs from cadaveric donors were cut into cortical rings and demineralised in 0.5 M hydrochloric acid for varying immersion times. Initial calcium content in the cortical bone measured by titration was 4.57%, only 21% of the measurement by neutron activation analysis; while measured by atomic absorption spectrophotometer was 13.4%, only 61% of neutron activation analysis. By comparing more readings with the measurements by neutron activation analysis with 93% recovery, a conversion factor of 4.83 was verified and applied for the readings by titration and 1.45 for atomic absorption spectrophotometer in calculating the correct calcium contents. The residual calcium content started to reduce after the cortical bone was demineralised in hydrochloric acid for 8 h and reduced to 13% after 24 h. Using the linear relationship, the residual calcium content could be reduced to less than 8% after immersion in hydrochloric acid for 40 h. Atomic absorption spectrophotometry technique is the method of choice for calcium content determination as it is more reliable compared to titrimetric assay.
    Matched MeSH terms: Cadaver
  17. Beh ZY, Hasan MS, Lai HY, Kassim NM, Md Zin SR, Chin KF
    BMC Anesthesiol, 2015;15:105.
    PMID: 26194896 DOI: 10.1186/s12871-015-0090-0
    The brachial plexus at the infraclavicular level runs deeper compared to its course proximally, giving rise to impaired needle visualisation due to the steep angle of needle insertion with the current ultrasound-guided approach. A new posterior parasagittal in-plane ultrasound-guided infraclavicular approach was introduced to improve needle visibility. However no further follow up study was done.
    Matched MeSH terms: Cadaver
  18. Kondo E, Merican AM, Yasuda K, Amis AA
    Arthroscopy, 2014 Mar;30(3):335-43.
    PMID: 24581258 DOI: 10.1016/j.arthro.2013.12.003
    The purpose of this study was to clarify the changes in the kinematics of the knee that result from isolated deficiency of the anteromedial (AM) or posterolateral (PL) bundle.
    Matched MeSH terms: Cadaver
  19. Schaubel DE, Stewart DE, Morrison HI, Zimmerman DL, Cameron JI, Jeffery JJ, et al.
    Arch. Intern. Med., 2000 8 6;160(15):2349-54.
    PMID: 10927733 DOI: 10.1001/archinte.160.15.2349
    BACKGROUND: Men in the United States undergoing renal replacement therapy are more likely than women to receive a kidney transplant. However, the ability to pay may, in part, be responsible for this finding.

    OBJECTIVE: To compare adult male and female transplantation rates in a setting in which equal access to medical treatment is assumed.

    METHODS: Using data from the Canadian Organ Replacement Register, the rate of first transplantations was computed for the 20, 131 men and the 13,458 women aged 20 years or older who initiated renal replacement therapy between January 1, 1981, and December 31, 1996. Poisson regression analysis was used to estimate the male-female transplantation rate ratio, adjusting for age, race, province, calendar period, underlying disease leading to renal failure, and dialytic modality. Actuarial survival methods were used to compare transplantation probability for covariable-matched cohorts of men and women.

    RESULTS: Men experienced 20% greater covariable-adjusted kidney transplantation rates relative to women (rate ratio, 1.20; 95% confidence interval, 1.13-1.27). The sex disparity was stronger for cadaveric transplants (rate ratio, 1.23) compared with those from living donors (rate ratio, 1.10). The 5-year probability of receiving a transplant was 47% for men and 39% for women within covariable-matched cohorts (P
    Matched MeSH terms: Cadaver
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links