Displaying publications 141 - 160 of 1044 in total

Abstract:
Sort:
  1. Bicchierai G, Nori J, De Benedetto D, Boeri C, Vanzi E, Bianchi S, et al.
    Tumori, 2019 Oct;105(5):378-387.
    PMID: 30558495 DOI: 10.1177/0300891618816212
    PURPOSE: To evaluate the role of contrast-enhanced spectral mammography (CESM) in the post biopsy management of breast lesions classified as lesions of uncertain malignant potential (B3) by core needle biopsy and vacuum-assisted biopsy (VAB).

    METHODS: The local ethics committee approved this retrospective study and for this type of study formal consent is not required. A total of 42 B3 lesions in 40 women aged 41-77 years were included in our study. All patients underwent CESM 2-3 weeks after the biopsy procedure and surgical excision was subsequently performed within 60 days of the CESM procedure. Three radiologists reviewed the images independently. The results were then compared with histologic findings.

    RESULTS: The sensitivity, specificity, and positive and negative predictive values for confirmed demonstration of malignancy at CESM were 33.3%, 87.2%, 16.7%, and 94.4% for reader 1; 66.7%, 76.9%, 18.2%, and 96.7% for reader 2; 66.7%, 74.4%, 16.7%, and 96.7% for reader 3. Overall agreement on detection of malignant lesions using CESM among readers ranged from moderate to substantial (κ = .451-.696), for categorization of BPE from moderate to substantial (κ = .562-.711), and for evaluation of lesion intensity enhancement from fair to moderate (κ = .346-.459).

    CONCLUSION: In cases of Breast Imaging Reporting and Data System (BI-RADS) 1, BI-RADS 2, or BI-RADS 3 results at CESM, follow-up or VAB rather than surgical biopsy might be performed.

    Matched MeSH terms: Sensitivity and Specificity
  2. Low GKK, Kagize J, Faull KJ, Azahar A
    Trop Med Int Health, 2019 10;24(10):1169-1197.
    PMID: 31373098 DOI: 10.1111/tmi.13294
    OBJECTIVE: To review the diagnostic test accuracy and predictive value of statistical models in differentiating the severity of dengue infection.

    METHODS: Electronic searches were conducted in the Cochrane Database of Systematic Reviews, Cochrane Central Register of Controlled Trials, MEDLINE (complete), PubMed and Scopus. Eligible studies to be included in this review were cohort studies with participants confirmed by laboratory test for dengue infection and comparison among the different severity of dengue infection by using statistical models. The methodological quality of the paper was assessed by independent reviewers using QUADAS-2.

    RESULTS: Twenty-six studies published from 1994 to 2017 were included. Most diagnostic models produced an accuracy of 75% to 80% except one with 86%. Two models predicting severe dengue according to the WHO 2009 classification have 86% accuracy. Both of these logistic regression models were applied during the first three days of illness, and their sensitivity and specificity were 91-100% and 79.3-86%, respectively. Another model which evaluated the 30-day mortality of dengue infection had an accuracy of 98.5%.

    CONCLUSION: Although there are several potential predictive or diagnostic models for dengue infection, their limitations could affect their validity. It is recommended that these models be revalidated in other clinical settings and their methods be improved and standardised in future.

    Matched MeSH terms: Sensitivity and Specificity
  3. Masdor NA, Altintas Z, Shukor MY, Tothill IE
    Sci Rep, 2019 09 20;9(1):13642.
    PMID: 31541137 DOI: 10.1038/s41598-019-49672-2
    In this work, a subtractive inhibition assay (SIA) based on surface plasmon resonance (SPR) for the rapid detection of Campylobacter jejuni was developed. For this, rabbit polyclonal antibody with specificity to C. jejuni was first mixed with C. jejuni cells and unbound antibody was subsequently separated using a sequential process of centrifugation and then detected using an immobilized goat anti-rabbit IgG polyclonal antibody on the SPR sensor chip. This SIA-SPR method showed excellent sensitivity for C. jejuni with a limit of detection (LOD) of 131 ± 4 CFU mL-1 and a 95% confidence interval from 122 to 140 CFU mL-1. The method has also high specificity. The developed method showed low cross-reactivity to bacterial pathogens such as Salmonella enterica serovar Typhimurium (7.8%), Listeria monocytogenes (3.88%) and Escherichia coli (1.56%). The SIA-SPR method together with the culturing (plating) method was able to detect C. jejuni in the real chicken sample at less than 500 CFU mL-1, the minimum infectious dose for C. jejuni while a commercial ELISA kit was unable to detect the bacterium. Since the currently available detection tools rely on culturing methods, which take more than 48 hours to detect the bacterium, the developed method in this work has the potential to be a rapid and sensitive detection method for C. jejuni.
    Matched MeSH terms: Sensitivity and Specificity
  4. Jirjees F, Soliman K, Wang Y, Sonawane R, Sheshala R, Jones D, et al.
    J Pharm Biomed Anal, 2019 Sep 10;174:145-150.
    PMID: 31167158 DOI: 10.1016/j.jpba.2019.05.038
    Bevacizumab is a full-length human monoclonal antibody used to treat various neovascular diseases such as wet age-related macular degeneration (AMD), diabetic eye disease and other problems of the retina. Monthly intravitreal injections of bevacizumab (Avastin®) are effective in the treatment of wet AMD. However, there is a growing demand in the development of sustained release ophthalmic formulations. Therefore, this study aims, for the first time, to develop a rapid, simple, and sensitive method using size exclusion chromatography coupled with fluorescence detection for routine quantification of bevacizumab in ophthalmic formulations and during in vitro release studies. The selected chromatographic conditions included an aqueous mobile phase composed of 35 mM sodium phosphate buffer and 300 mM sodium chloride (pH 6.8), a flow rate of 0.5 mL/min, and the fluorescence detector was operated at excitation and emission wavelengths of 280 and 340 nm, respectively. The peak area-concentration relationship maintained its linearity over concentration range of 0.1-20 μg/mL (R2 = 0.9993), and the quantitation limit was 100 ng/mL. The method was validated for specificity, accuracy, precision, and robustness. The developed method had a run time of 6 min at temperature 25 °C, making it a unique validated method for rapid and cost-effective quantification of bevacizumab.
    Matched MeSH terms: Sensitivity and Specificity
  5. Tan WS, Teo CH, Chan D, Heinrich M, Feber A, Sarpong R, et al.
    BJU Int, 2019 09;124(3):408-417.
    PMID: 30694612 DOI: 10.1111/bju.14690
    OBJECTIVES: To determine the minimal accepted sensitivity (MAS) of a urine biomarker that patients are willing to accept to replace cystoscopy and to assess qualitatively their views and reasons.

    PATIENTS AND METHODS: Patients were part of a prospective multicentre observational study recruiting people with bladder cancer for a urine biomarker study (DETECT II; ClinicalTrials.gov: NCT02781428). A mixed-methods approach comprising (1) a questionnaire to assess patients' experience with cystoscopy and patients' preference for cystoscopy vs urinary biomarker, and (2) semi-structured interviews to understand patient views, choice and reasons for their preference.

    RESULTS: A urine biomarker with an MAS of 90% would be accepted by 75.8% of patients. This was despite a high self-reported prevalence of haematuria (51.0%), dysuria/lower urinary tract symptoms (69.1%) and urinary tract infection requiring antibiotics (25.8%). There was no association between MAS with patient demographics, adverse events experienced, cancer characteristics or distance of patients' home to hospital. The qualitative analysis suggested that patients acknowledge that cystoscopy is invasive, embarrassing and associated with adverse events but are willing to tolerate the procedure because of its high sensitivity. Patients have confidence in cystoscopy and appreciate the visual diagnosis of cancer. Both low- and high-risk patients would consider a biomarker with a reported sensitivity similar to that of cystoscopy.

    CONCLUSION: Patients value the high sensitivity of cystoscopy despite the reported discomfort and adverse events experienced after it. The sensitivity of a urinary biomarker must be close to cystoscopy to gain patients' acceptance.

    Matched MeSH terms: Sensitivity and Specificity
  6. Ambily R, Mini M, Siju J, Vamshikrishna S, Abhinay G, Gleeja VL, et al.
    Trop Biomed, 2019 Sep 01;36(3):654-663.
    PMID: 33597487
    A study was undertaken to evaluate the relevance of detecting IgM and IgG antibodies in diagnosis of canine leptospirosis in Kerala, a southern state of India, which is endemic for the disease. A total of 205 blood (35 from healthy vaccinated, 30 from healthy unvaccinated and 140 from diseased dogs) and 151 urine samples (11 from healthy vaccinated and 140 from diseased dogs) were collected from three districts of Kerala, Thrissur, Palakkad and Kozhikode with high incidence of leptospirosis. Recombinant LipL41 protein was used as antigen and IgG and IgM based ELISAs were standardized. The results were compared with the gold standard test, microscopic agglutination test (MAT). The MAT positive samples (146 samples) were divided into those having titre >1:800 and those between 1:100 and 1:400 in view that the former constituted the acute cases. It was found that IgM ELISA was more specific and sensitive in detecting acute cases (MAT >1:800) whereas IgG ELISA was less specific. In case of seroprevalence studies (MAT titre 1:100 to 1: 400), IgG ELISA was found to be more sensitive and specific than IgM ELISA. Receiver operating characteristic curves when plotted, revealed the accuracy of IgM ELISA in acute leptospirosis. Many samples were positive for both IgG and IgM antibodies. Polymerase Chain Reaction (PCR) targeting lipl41 gene was standardized and urine and blood samples from the same dogs were tested. PCR was found to be the specific test for the early detection of leptospires in blood even before seroconversion. However, PCR analysis of the urine samples was found to be insensitive. Hence, it can be concluded that the diagnostic strategies should be modified, and a combination of serological and molecular tests is recommended in endemic areas rather than simple detection of IgM or IgG antibodies, for the early detection of acute clinical cases of leptospirosis.
    Matched MeSH terms: Sensitivity and Specificity
  7. Ashouri Saheli Z, Shenagari M, Harzandi N, Monfared A
    Trop Biomed, 2019 Sep 01;36(3):766-775.
    PMID: 33597498
    The need for an intensive care protocol, sometimes weekly or biweekly, has led to a significant increase in laboratory costs for kidney recipients. In the present study, an inhouse tetraplex nested PCR assay was developed and validated for the specific detection of BKV, JCV, HCMV and EBV in clinical samples. We determined the Limit of Detection (LOD) and analytical specificity. To demonstrate the diagnostic performance of the assay, a total of 102 archival plasma samples were tested and compared with a commercial uniplex real-time PCR kits. The analytical sensitivity of the in-house tetraplex nested PCR assay was 173 copies/ml, when all four viruses were present in the specimens. These values were 79.2, 58.7, 87.6 and 96.1 copies/ml when only, BKV, JCV, HCMV and EBV respectively, were present. The cross-reactivity assays were shown no detectable signal in the tetraplex PCR results. The estimated diagnostic sensitivities were 92.6% for BKV, 92.3% for JCV and 100% for both HCMV and EBV as compared with commercial kits. Regarding the sensitivity and specificity, it seems that the developed Multiplex Nested PCR assay could be used as a reliable virusassociated renal rejection (VRR) panel in post renal transplant surveillance.
    Matched MeSH terms: Sensitivity and Specificity
  8. Rahumatullah A, Lim TS, Yunus MH, Noordin R
    Am J Trop Med Hyg, 2019 08;101(2):436-440.
    PMID: 31162018 DOI: 10.4269/ajtmh.19-0034
    Lymphatic filariasis is a mosquito-borne parasitic disease responsible for morbidity and disability that affects 1.2 billion people worldwide, mainly the poor communities. Currently, filarial antigen testing is the method of choice for the detection of bancroftian filariasis, and to date, there are two commonly used tests. In the present study, a recently reported recombinant monoclonal antibody (5B) specific to BmSXP filarial antigen was used in developing an ELISA for the detection of circulating filarial antigen in sera of patients with bancroftian filariasis. The performance of the ELISA was evaluated using 124 serum samples. The ELISA was positive with all sera from microfilaremic bancroftian filariasis patients (n = 34). It also showed 100% diagnostic specificity when tested with sera from 50 healthy individuals and 40 patients with other parasitic diseases. The developed assay using the novel 5B recombinant monoclonal antibody could potentially be a promising alternative antigen detection test for bancroftian filariasis.
    Matched MeSH terms: Sensitivity and Specificity
  9. Chong YM, Tan XH, Hooi PS, Lee LM, Sam IC, Chan YF
    J Med Virol, 2019 08;91(8):1562-1565.
    PMID: 31032971 DOI: 10.1002/jmv.25495
    Rapid diagnosis of influenza is important for early treatment and institution of control measures. In developing tropical countries such as Malaysia, influenza occurs all year round, but molecular assays and conventional techniques (such as immunofluorescence and culture) for diagnosis are not widely available. Rapid influenza diagnostic tests (RIDTs) may be useful in this setting. A total of 552 fresh respiratory specimens were assessed from patients with respiratory symptoms at a teaching hospital in Kuala Lumpur, Malaysia from November 2017 to March 2018. Two digital immunoassays (DIAs), STANDARD F Influenza A/B Fluorescence Immunoassay (STANDARD F) and Sofia Influenza A + B Fluorescence Immunoassay (Sofia) and one conventional RIDT (immunochromatographic assay), SD Bioline Influenza Ag A/B/A(H1N1) Pandemic rapid test kit (SD Bioline) were evaluated in comparison with a WHO-recommended reverse transcription quantitative PCR (RT-qPCR). Of the 552 samples, influenza A virus was detected in 47 (8.5%) and influenza B virus in 7 (1.3%). The digital immunoassays STANDARD F and Sofia had significantly higher overall sensitivity rates (71.7% and 70.6%, respectively) than the conventional RIDT SD Bioline and immunofluorescence/viral culture (55.8% and 52.8%, respectively). Sensitivity rates were higher for influenza A than influenza B, and specificity rates were uniformly high, ranging from 98% to 100%. Digital readout RIDTs can be used in tropical settings with year-round influenza if PCR is unavailable.
    Matched MeSH terms: Sensitivity and Specificity
  10. Kato TA, Katsuki R, Kubo H, Shimokawa N, Sato-Kasai M, Hayakawa K, et al.
    Psychiatry Clin Neurosci, 2019 Aug;73(8):448-457.
    PMID: 30900331 DOI: 10.1111/pcn.12842
    AIM: Understanding premorbid personality is important, especially when considering treatment selection. Historically, the premorbid personality of patients with major depression in Japan was described as Shuchaku-kishitsu [similar to Typus melancholicus], as proposed by Shimoda in the 1930s. Since around 2000, there have been increased reports in Japan of young adults with depression who have had premorbid personality differing from the traditional type. In 2005, Tarumi termed this novel condition 'dysthymic-type depression,' and more recently the condition has been called Shin-gata/Gendai-gata Utsu-byo [modern-type depression (MTD)]. We recently developed a semi-structured diagnostic interview to evaluate MTD. Development of a tool that enables understanding of premorbid personality in a short time, especially at the early stage of treatment, is desirable. The object of this study was to develop a self-report scale to evaluate the traits of MTD, and to assess the scale's psychometric properties, diagnostic accuracy, and biological validity.

    METHODS: A sample of 340 participants from clinical and community settings completed measures. Psychometric properties were assessed with factor analysis. Diagnostic accuracy of the MTD traits was compared against a semi-structured interview.

    RESULTS: The questionnaire contained 22 items across three subscales, thus we termed it the 22-item Tarumi's Modern-Type Depression Trait Scale: Avoidance of Social Roles, Complaint, and Low Self-Esteem (TACS-22). Internal consistency, test-retest reliability, and convergent validity were all satisfactory. Among patients with major depression, the area under the curve was 0.757 (sensitivity of 63.1% and specificity of 82.9%) and the score was positively correlated with plasma tryptophan.

    CONCLUSION: The TACS-22 possessed adequate psychometric properties and diagnostic accuracy in an initial sample of Japanese adults. Additional research on its ability to support clinical assessment of MTD is warranted.

    Matched MeSH terms: Sensitivity and Specificity
  11. Yunus MH, Arifin N, Balachandra D, Anuar NS, Noordin R
    Am J Trop Med Hyg, 2019 08;101(2):432-435.
    PMID: 31218996 DOI: 10.4269/ajtmh.19-0053
    The conventional method of detecting Strongyloides stercoralis in fecal samples has poor diagnostic sensitivity. Detection of Strongyloides-specific antibodies increases the sensitivity; however, most tests are ELISAs that use parasite extract which may cross-react with the sera of other helminth infections. To improve the serological diagnosis of strongyloidiasis, this study aimed at developing a sensitive and specific lateral flow rapid dipstick test. Two recombinant proteins, recombinant NIE (rNIE) and recombinant Ss1a (rSs1a), were used in preparing the dipstick, with gold-conjugated antihuman IgG4 as detector reagent. In parallel, the corresponding ELISA was performed. Both assays demonstrated diagnostic sensitivity of 91.3% (21/23) when tested with serum samples of patients with Strongyloides infection, and 100% specificity with 82 sera of asymptomatic (healthy) and those with other parasitic infections. The ELISA and dipstick test results were positively correlated to each other (r = 0.6114, P = 0.0019). The developed lateral flow dipstick test may improve the serodiagnosis of strongyloidiasis and merit further validation studies.
    Matched MeSH terms: Sensitivity and Specificity
  12. Fong SL, Lim KS, Tan L, Aris T, Khalid RA, Ali RA, et al.
    Epilepsy Behav, 2019 08;97:206-211.
    PMID: 31252280 DOI: 10.1016/j.yebeh.2019.05.033
    INTRODUCTION: Prevalence studies of epilepsy in Asia revealed a prevalence ranging from 1.5 to 14.0 per 1000 among Asian populations. However, the prevalence of epilepsy in Malaysia is not available for comparison with other countries. This study aimed to translate and validate a Malay brief screening instruments for ascertainment of epilepsy.

    METHOD: We translated into Malay a brief screening instrument for ascertainment of epilepsy designed and validated by Ottman et al., using the three-stage cross-cultural adaptation process developed by the International Quality of Life Assessment (IQOLA) project. We then administered the translated questionnaire via online survey to 162 cases (patients with epilepsy under follow-up care at the neurology clinic in University of Malaya Medical Centre, Kuala Lumpur) and 146 controls with no known history of epilepsy for validation.

    RESULTS: Applying the most liberal definition for a positive screen, we obtained a sensitivity of 96.3% (95% confidence interval [CI]: 91.8-98.5%), with a specificity of 66.4% (95% CI: 58.1-73.0%) and positive predictive value (PPV) of 2.0%. The most stringent definition for a positive screen (only epilepsy) resulted in a sensitivity of 97.4% (95% CI: 62.0-72.6%), specificity of 98.6% (95% CI: 94.6-99.7%), and PPV of 26.6%. Narrowing the definition of a positive screen decreased sensitivity but improved PPVs. When compared to the original English questionnaire, the sensitivities were similar for all four definitions of a positive screen.

    CONCLUSION: This is the first validated epilepsy screening questionnaire in the Malay language and represents a useful tool for the ascertainment of epilepsy in population-based studies.

    Matched MeSH terms: Sensitivity and Specificity
  13. Boo NY, Chang YF, Leong YX, Tok ZY, Hooi LC, Chee SC, et al.
    Pediatr Res, 2019 08;86(2):216-220.
    PMID: 30696987 DOI: 10.1038/s41390-019-0304-0
    BACKGROUND: This study aimed to determine the accuracy of a point-of-care Bilistick method for measuring total serum bilirubin (TSB) and its turn-around-time (TAT) against hospital laboratory methods.

    METHODS: This prospective study was carried out on 561 term-gestation jaundiced neonates in two Malaysian hospitals. Venous blood sample was collected from each neonate for contemporary measurement of TSB by hospital laboratories and Bilistick. TAT was the time interval between specimen collection and TSB result reported by each method.

    RESULTS: The mean laboratory-measured TSB was 194.85 (±2.844) µmol/L and Bilistick TSB was 169.37 (±2.706) µmol/L. Pearson's correlation coefficient was: r = 0.901 (p 

    Matched MeSH terms: Sensitivity and Specificity
  14. Rahmani M, Ghafoorifard H, Afrang S, Ahmadi MT, Rahmani K, Ismail R
    IET Nanobiotechnol, 2019 Aug;13(6):584-592.
    PMID: 31432790 DOI: 10.1049/iet-nbt.2018.5288
    The response of trilayer graphene nanoribbon (TGN)-based ion-sensitive field-effect transistor (ISFET) to different pH solutions and adsorption effect on the sensing parameters are analytically studied in this research. The authors propose a TGN-based sensor to electrochemically detect pH. To this end, absorption effect on the sensing area in the form of carrier concentration, carrier velocity, and conductance variations are investigated. Also, the caused electrical response on TGN as a detection element is analytically proposed, in which significant current decrease of the sensor is observed after exposure to high pH values. In order to verify the accuracy of the model, it is compared with recent reports on pH sensors. The TGN-based pH sensor exposes higher current compared to that of carbon nanotube (CNT) counterpart for analogous ambient conditions. While, the comparative results demonstrate that the conductance of proposed model is lower than that of monolayer graphene-counterpart for equivalent pH values. The results confirm that the conductance of the sensor is decreased and Vg-min is obviously right-shifted by increasing value of pH. The authors demonstrate that although there is not the experimental evidence reported in the part of literature for TGN sensor, but the model can assist in comprehending experiments involving nanoscale pH sensors.
    Matched MeSH terms: Sensitivity and Specificity
  15. Abd Rahim MA, Johani FH, Shah SA, Hassan MR, Abdul Manaf MR
    Ann Glob Health, 2019 Jul 24;85(1).
    PMID: 31348624
    BACKGROUND: Helicobacter pylori (H. pylori) infection is known to be associated with peptic ulcer and gastric cancer. Detection of H. pylori infection is a significant part of peptic ulcer and gastric cancer prevention and management. 13C-urea breath test (UBT) provides a good option for the pathogen detection due to its accuracy and safety.

    OBJECTIVE: This review aims to evaluate the 13C-UBT diagnostic accuracy studies conducted among Asian population and validate its use for the Asian population.

    METHODS: Original articles were systematically searched in PubMed, Scopus, and Google Scholar using the PICOS strategy by applying relevant keywords. Only studies published in English and conducted in Asia were included. Our search returned 276 articles. After assessment, 11 articles which answered our research question and met the criteria set for systematic review and meta-analysis were accepted. A total of 15 study protocols were extracted from the 11 accepted articles.

    FINDINGS: Majority of the studies were conducted in Hong Kong (six), followed by Taiwan (five), Japan (two), and one each in Singapore and Israel. All studies had used histology as part of its gold standard of reference. All but one study was performed on adult populations. The summary estimate for sensitivity was 97% (95% CI: 96, 98%), and specificity was 96% (95% CI: 95, 97%), with significant heterogeneity between studies. Adjusting for the dose (50 mg) and breath sample collection time (20 minutes) had improved both accuracy estimates and significantly reduced heterogeneity.

    CONCLUSION: This review supports the test-and-treat strategy for H. pylori infection management. Prevalence and cost-effectiveness studies are mandatory for health authorities to adopt this strategy into national policy.

    Matched MeSH terms: Sensitivity and Specificity
  16. Guo S, Lakshmipriya T, Gopinath SCB, Anbu P, Feng Y
    Nanoscale Res Lett, 2019 Jul 02;14(1):222.
    PMID: 31267309 DOI: 10.1186/s11671-019-3058-z
    Developing an enhanced diagnosis using biosensors is important for the treatment of patients before disease complications arise. Improving biosensors would enable the detection of various low-abundance disease biomarkers. Efficient immobilization of probes/receptors on the sensing surface is one of the efficient ways to enhance detection. Herein, we introduced the pre-alkaline sensing surface with amine functionalization for capturing gold nanoparticle (GNP) conjugated to human blood clotting factor IX (FIX), and we demonstrated the excellent performance of the strategy. We have chosen the enzyme-linked immunosorbent assay (ELISA) and the interdigitated electrode (IDE), which are widely used, to demonstrate our method. The optimal amount for silanization has been found to be 2.5%, and 15-nm-sized GNPs are ideal and characterized. The limit of FIX detection was attained with ELISA at 100 pM with the premixed GNPs and FIX, which shows 60-fold improvement in sensitivity without biofouling, as compared to the conventional ELISA. Further, FIX was detected with higher specificity in human serum at a 1:1280 dilution, which is equivalent to 120 pM FIX. These results were complemented by the analysis on IDE, where improved detection at 25 pM was achieved, and FIX was detected in human serum at the dilution of 1:640. These optimized surfaces are useful for improving the detection of different diseases on varied sensing surfaces.
    Matched MeSH terms: Sensitivity and Specificity
  17. Chuah KH, Wan Yusoff WNI, Sthaneshwar P, Nik Mustapha NR, Mahadeva S, Chan WK
    Liver Int, 2019 07;39(7):1315-1324.
    PMID: 30825254 DOI: 10.1111/liv.14084
    INTRODUCTION: MACK-3 (combination of hoMa, Ast and CK18) was reported to be a good biomarker for the diagnosis of fibrotic non-alcoholic steatohepatitis (NASH). However, there is no external validation to date.

    AIM: To evaluate the accuracy of MACK-3 for the diagnosis of fibrotic NASH.

    METHODOLOGY: Consecutive adult non-alcoholic fatty liver disease (NAFLD) patients who had liver biopsy in a university hospital were included. MACK-3 was calculated using the online calculator using the following variables: fasting glucose, fasting insulin, aspartate aminotransferase (AST) and cytokeratin 18 (CK18). MACK-3 cut-offs ≤0.134 and ≥0.550 were used to predict absence and presence of fibrotic NASH, respectively. Histopathological examination of liver biopsy specimen was reported according to the NASH Clinical Research Network Scoring System.

    RESULTS: Data for 196 subjects were analysed. MACK-3 was good for diagnosis of fibrotic NASH (area under receiver-operating characteristics curve [AUROC] 0.80), comparable to the Fibrosis-4 index (FIB4) and the NAFLD fibrosis score (NFS) and superior to the BARD score and CK18. MACK-3 was good for diagnosis of active NASH (AUROC 0.81) and was superior to other blood fibrosis tests. The overall accuracy, percentage of subjects in grey zone, sensitivity, specificity, positive predictive value and negative predictive value of MACK-3 for diagnosis of fibrotic NASH was 79.1%, 46.9%, 100%, 43.8%, 43.1% and 100%, respectively, while for diagnosis of active NASH was 90.0%, 39.3%, 84.2%, 81.4%, 88.9% and 74.5%, respectively.

    CONCLUSION: MACK-3 is promising as a non-invasive test for active NASH and fibrotic NASH and may be useful to identify patients who need more aggressive intervention.

    Matched MeSH terms: Sensitivity and Specificity
  18. Hassan H, Razak HRA, Saad FFA, Kumar V
    Malays J Med Sci, 2019 Jul;26(4):122-126.
    PMID: 31496901 MyJurnal DOI: 10.21315/mjms2019.26.4.14
    Using radiolabelled peptides that bind, with high affinity and specificity, to receptors on tumour cells is one of the most promising fields in modern molecular imaging and targeted radionuclide therapy (1). In the emergence of molecular imaging and nuclear medicine diagnosis and therapy, albeit theranostic, radiolabelled peptides have become vital tools for in vivo visualisation and monitoring physiological and biochemical processes on molecular and cellular levels (2). This approach may benefit patients in the era of personalised medicine.
    Matched MeSH terms: Sensitivity and Specificity
  19. Omar J, Isa S, Ismail TST, Yaacob NM, Soh NAAC
    Malays J Med Sci, 2019 Jul;26(4):61-69.
    PMID: 31496894 MyJurnal DOI: 10.21315/mjms2019.26.4.7
    Background: As an early recognition of neonatal sepsis is important for triggering the initiation of treatment, this study was thus designed to assess the diagnostic performance and discrimination value of procalcitonin (PCT) in neonatal sepsis cases.

    Methods: This cross-sectional study, which was carried out at the Paediatric Intensive Care Unit of Hospital Universiti Sains Malaysia (HUSM) in Kelantan, Malaysia, had involved 60 neonates admitted for suspected sepsis. Sensitivity, specificity, positive predictive values (PPV), negative predictive values (NPV) and the area under receiver operating characteristics curve (AUC) for PCT were determined at initial presentation (0 h) as well as 12 h and 24 h after presentation in comparison to blood culture as the gold standard.

    Results: The study consisted of 27 (45.0%) male and 33 (55.0%) female neonates with a mean (SD) age of 76.8 (48.25) h. At cut-off PCT value of > 2 ng/mL, the sensitivity, specificity, PPV and NPV were 66.7%, 66.7%, 33.3% and 88.9% at 0 h. The respective parameters were 83.3%. 56.3%, 32.3% and 93.1% at 12 h and 83.3%, 52.1%, 30.3% and 92.6% at 24 h. AUC was 71.6%, 76.6% and 71.7% at 0 h, 12 h and 24 h.

    Conclusions: Diagnostic performance and discrimination values of PCT for diagnosis of neonatal sepsis varied with time of obtaining the blood samples. The PCT result at 12 h demonstrates the most optimal diagnostic performance and discrimination values.

    Matched MeSH terms: Sensitivity and Specificity
  20. Mussa A, Talib M, Mohamed Z, Hajissa K
    BMC Res Notes, 2019 Jun 11;12(1):334.
    PMID: 31186056 DOI: 10.1186/s13104-019-4361-6
    OBJECTIVE: Rapid diagnostic tests (RDTs) play a crucial role in the management and control of malaria infection. The histidine-rich protein 2 (PfHRP-2) based RDTs are the most commonly used RDTs for malaria diagnosis in Sudan. Deletion of pfhrp2 in Plasmodium falciparum genome affect the accuracy of PfHRP-2 based RDT kits. This study aimed to identify molecular variation of pfhrp2 among suspected malaria patients from different clinics in Omdurman, Sudan.

    RESULTS: A noticeable variation between the RDT (Alltest Biotech, China) and nPCR results was observed, for RDT 78% (46/59) were P. falciparum positive, 6.8% (4/59) were co-infected with both P. falciparum and Plasmodium vivax, 15.3% (9/59) were negative by the RDT. However, when the nPCR was applied only 44.1% (26/59) and 55.9% (33/59) was P. falciparum positive and negative respectively. The pfhrp2 was further amplified form all nPCR positive samples. Only 17 DNA samples were positive from the 26 positive P. falciparum, interestingly, variation in band sizes was observed and further confirmed by DNA sequencing, and sequencing analysis revealed a high-level of genetic diversity of the pfhrp2 gene in the parasite population from the study area. However, despite extreme sequence variation, diversity of PfHRP2 does not appear to affect RDT performance.

    Matched MeSH terms: Sensitivity and Specificity
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links