Displaying publications 141 - 160 of 238 in total

Abstract:
Sort:
  1. Yarima MH, Khandaker MU, Nadhiya A, Olatunji MA
    Radiat Prot Dosimetry, 2019 Oct 01;184(3-4):359-362.
    PMID: 31089715 DOI: 10.1093/rpd/ncz115
    Uranium, thorium and potassium are the most abundant naturally occurring radioactive materials (NORMs) found in soils and other environmental media including foodstuffs. Since the human exposures to NORMs is an unavoidable phenomenon, in such a way that they can easily find their way to human being via food chain, detailed knowledge on their presence in foodstuffs is necessary to assess the radiation dose to the population. Thus, the present study concerns the assessment of natural radioactivity in maize, a staple foodstuff for Nigerian, via HPGe gamma-ray spectrometry. Activity concentrations (Bq/kg) in the maize samples were found to be in the range of 6.1 ± 0.6-8.2 ± 1.3, 2.2 ± 0.4-5.1 ± 0.7 and 288 ± 16-401 ± 24 for 226Ra, 232Th and 40K, respectively. Measured data for 226Ra and 232Th show below the world average values of 67 Bq/kg and 82 Bq/kg, respectively, while the activity of 40K exceeds the global average of 310 Bq/kg. The annual effective dose via the maize consumption was found to be far below the UNSCEAR recommended ingestion dose limit of 290 μSv/y, and the estimated lifetime cancer risk show lower than the ICRP (1991) cancer risk factor of 2.5 × 10-3 based on the additional annual dose limit of 1 mSv for general public, thus pose no adverse health risk to the Nigerian populace.
    Matched MeSH terms: Potassium Radioisotopes/analysis*
  2. Usmani S, Rasheed R, Al Kandari F
    J Nucl Med Technol, 2020 Jun;48(2):181-183.
    PMID: 32111663 DOI: 10.2967/jnmt.119.235986
    Textitis is a new term used to refer to the degenerative-strain osteoarthritis that comes from excessive use of a smart phone. 18F-NaF is increasingly used in diagnosing skeletal pain that is not identified on radiographs. We report a case of a 26-y-old woman with left breast cancer referred for 18F-NaF PET/CT, who was complaining of right thumb and wrist pain. Findings were negative for bone secondaries. Dedicated hands views were acquired on a positron emission mammography scanner and showed focal uptake at the first carpometacarpal and second metacarpophalangeal joints. On the basis of the strong history, the findings were likely due to active arthritic changes caused by repetitive strain injury from excessive text messaging.
    Matched MeSH terms: Fluorine Radioisotopes*
  3. Samat SB, Evans CJ, Kadni T, Dolah MT
    Br J Radiol, 2000 Aug;73(872):867-77.
    PMID: 11026863
    A cylindrical gamma-ray 60Co source of activity alpha is predicted to produce an exposure rate X at a distance d in vacuum, given by X = gamma(T)(alpha/d2), where gamma(T) is the specific gamma-ray constant. It has been documented that this formula may be used to approximate X with an accuracy of 1% from a source of length l, provided that d/l > or = 5. It is shown that the formula is accurate to 0.1% under these conditions, provided that the distance is measured from the centre of the source. When absorption in the source and scattering in the collimator are considered, the position of the origin d = 0 can shift by a distance of the order of centimetres. Absorption in air between the source and the ionization chamber adds an exponential factor to the formula. It is shown that even when these modifications are included the discrepancy in the results, although generally less than 1%, is still large compared with the measurement errors. Some suggestions are made for the origin of this discrepancy.
    Matched MeSH terms: Cobalt Radioisotopes/therapeutic use*
  4. Lai FM, Liam CK, Paramsothy M, George J
    Int J Tuberc Lung Dis, 1997 Dec;1(6):563-9.
    PMID: 9487455
    University Hospital, Kuala Lumpur, Malaysia.
    Matched MeSH terms: Gallium Radioisotopes*
  5. Sarmani SB, Kiprawi AZ, Ismail RB
    Biol Trace Elem Res, 1994;43-45:435-41.
    PMID: 7710858
    Fish has been known as a source of nonoccupational mercury exposure to fish-consuming population groups. In this study, hair samples collected from fishermen and their families residing in an industrialized area in Penang and a nonindustrialized area in Terengganu were analyzed for mercury by neutron activation. The range, arithmetic mean, geometric mean, and median of the mercury concentrations for the groups in Penang and in Terengganu were 0.45-16.68, 3.61, 3.49, and 2.96 and 6.79-18.31, 12.08, 11.69, and 12.05 mg/kg, respectively. Somewhat lower values than from the Penang group were found in a group from Selangor consisting mainly of office workers. The group in Penang took about 40-100 g of fish/d, whereas the group in Terengganu consumed twice as much. This shows that hair mercury levels depend on a fish consumption pattern, and not on the location of the population. The levels of mercury found in this study were similar to those reported by other workers for fish-consuming population groups worldwide.
    Matched MeSH terms: Mercury Radioisotopes/analysis
  6. Samat SB, Evans CJ
    Radiat Prot Dosimetry, 2003;103(4):341-7.
    PMID: 12797557
    For the specific absorbed dose constant for 60Co photons, three values quoted directly in the literature and two derived indirectly from published information are reported. The three publications giving the direct values mentioned no medium of absorption, whereas the other two specify tissue. A database of the specific absorbed dose constant is generated for each of 14 media namely air, water, bone and 11 types of soft tissue. These values are consistent with the three directly quoted values plus one of the indirectly obtained values. Air is found to be unlikely as the medium for the first three; and appropriate media for these are suggested. For the other two values, the generated database suggests that one is too small to be accurate; while the other is correct for tissue (as stated in the publication). An apparent error of 10(3) is identified in one of the values directly quoted.
    Matched MeSH terms: Cobalt Radioisotopes*
  7. Zaini A, Khir A, Doi SA, Chan SP, Paramsothy M, Khoo BH
    J Int Med Res, 1992 Jun;20(3):279-88.
    PMID: 1397673
    To evaluate the effects of simple compensated fixed-dose iodine-131 therapy for thyrotoxicosis, the long-term results for 74 patients treated with a fixed dose of iodine-131 ranging from 5 to 12 mCi (185 to 444 MBq) were evaluated in the first 2 years of a trial. The dose selected was loosely based on the gross size of the thyroid gland. Routine antithyroid drug therapy was given for a minimum of 3 months after iodine-131 therapy. The mean (+/- SD) duration of follow-up was 74.5 +/- 42 months. The results indicated that roughly 25% of patients treated in this way will become hypothyroid after 5 years and that 85% are cured (need no further therapy during the follow-up period) using a single dose of iodine-131. Of those cured using a single iodine-131 dose, 81% were no longer receiving drugs after 6 months and 85% after 1 year. Such a regimen seems currently to be among the best available where prolonged periods of medication-free euthyroidism after therapy are sought.
    Matched MeSH terms: Iodine Radioisotopes/therapeutic use*
  8. Nazeri AAZA, Sani SFA, Ung NM, Almugren KS, Alkallas FH, Bradley DA
    Appl Radiat Isot, 2021 Oct;176:109814.
    PMID: 34175543 DOI: 10.1016/j.apradiso.2021.109814
    Brachytherapy is commonly used in treatment of cervical, prostate, breast and skin cancers, also for oral cancers, typically via the application of sealed radioactive sources that are inserted within or alongside the area to be treated. A particular aim of the various brachytherapy techniques is to accurately transfer to the targeted tumour the largest possible dose, at the same time minimizing dose to the surrounding normal tissue, including organs at risk. The dose fall-off with distance from the sources is steep, the dose gradient representing a prime factor in determining the dose distribution, also representing a challenge to the conduct of measurements around sources. Amorphous borosilicate glass (B2O3) in the form of microscope cover slips is recognized to offer a practicable system for such thermoluminescence dosimetry (TLD), providing for high-spatial resolution (down to 
    Matched MeSH terms: Cobalt Radioisotopes/administration & dosage*
  9. Lee SK, Wagiran H, Ramli AT, Apriantoro NH, Wood AK
    J Environ Radioact, 2009 May;100(5):368-74.
    PMID: 19299052 DOI: 10.1016/j.jenvrad.2009.01.001
    Natural background gamma radiation and radioactivity concentrations were investigated from 2003 to 2005 in Kinta District, Perak, Malaysia. Sample locations were distant from any 'amang' processing plants. The external gamma dose rates ranged from 39 to 1039 nGy h(-1). The mean external gamma dose rate was 222+/-191 nG yh(-1). Small areas of relatively enhanced activity were located having external gamma dose rates of up to 1039+/-104 nGy h(-1). The activity concentrations of (238)U, (232)Th and (40)K were analyzed by using a high-resolution co-axial HPGe detector system. The activity concentration ranges were 12-426 Bq kg(-1) for (238)U, 19-1377 Bq kg(-1) for (232)Th and <19-2204 Bq kg(-1) for (40)K. Based on the radioactivity levels determined, the gamma-absorbed dose rates in air at 1m above the ground were calculated. The calculated dose rates and measured dose rates had a good correlation coefficient, R of 0.94. To evaluate the radiological hazard of the natural radioactivity, the radium equivalent activity, the gamma-absorbed dose rate and the mean population weighted dose rate were calculated. An isodose map for the Kinta District was also produced.
    Matched MeSH terms: Radioisotopes/analysis*
  10. Sundram F
    Biomed Imaging Interv J, 2006 Jul;2(3):e40.
    PMID: 21614248 MyJurnal DOI: 10.2349/biij.2.3.e40
    Hepatocellular carcinoma (HCC) is a malignant tumour of the hepatocyte. It is a common malignancy worldwide and causes almost half a million deaths annually. Asia is a high risk area. Although surgery (hepatectomy or liver transplantation) is the main form of curative treatment, the majority of patients are not eligible for surgery due to extent of tumour and dysfunction of liver. Radiopharmaceuticals used for transarterial treatment of HCC were Yttrium-90 microspheres, Iodine-131 lipiodol, Rhenium-188 lipiodol, and Holmium-166 Chitosan complex. Yittrium-90 microspheres are glass or resin microspheres of mean sphere diameter of 20 to 30 micrometre. The activity administered was about 4 GBq. Reported response rate was about 20%, and median survival was 54 weeks. On inoperable tumours, reported objective response of I-131 lipiodol was 40 to 70%, and median survival was six to nine months. It showed efficacy similar to TACE. In adjuvant treatment following curative resection of HCC, reported three year survival was 86% compared with 46% for the control group. The administered activity in both adjuvant and inoperable HCC was about 2 GBq (55 mCi). Rhenium-188 lipiodol is a new radioconjugate, and using it we treated 70 patients with inoperable HCC. This treatment was a part of a multi-centre trial sponsored by the International Atomic Energy Agency. Partial response was obtained in 17% of cases, while 49% had stable disease at three months, and 34% showed disease progression. In terms of survival, 19% survived one year, 60% for six months, and 90% for three months. The mean activity was about 4.6 GBq (124 mCi). This method was safe and free from adverse effects.
    Matched MeSH terms: Iodine Radioisotopes; Yttrium Radioisotopes
  11. Bahari I, Mohsen N, Abdullah P
    J Environ Radioact, 2007;95(2-3):161-70.
    PMID: 17428589
    The processing of amang, or tin tailings, for valuable minerals has been shown to technologically enhance NORM and this has stirred significant radiological safety and health concerns among Malaysia's regulatory authority. A growing radiological concern is now focused on the amang effluent containing NORM in recycling ponds, since these ponds may be reclaimed for future residential developments. A study was carried out to assess the radiological risk associated with amang processing and the accumulated effluent in the recycling ponds. Twenty-six sediment samples from the recycling ponds of two amang plants in the states of Selangor and Perak, Malaysia, were collected and analyzed. The maximum activity concentrations of (238)U, (226)Ra, (232)Th and (40)K recorded in sediments from these ponds were higher than Malaysia's and the world's natural highest. Correspondingly, the mean radium equivalent activity concentration indices, Ra(eq), and gamma radiation representative level index, I(gammar), were higher than the world's average. The enhancement of NORM in effluent sediments as a consequence of amang processing, and the use of a closed water management recycling system created Effective Dose Rates, E (nSv h(-1)), that signal potential environmental radiological risks in these ponds, should they be reclaimed for future land use.
    Matched MeSH terms: Potassium Radioisotopes/analysis*
  12. Kamarulzaman K, Mohd Rohani MF, Mat Nawi N, Amir Hassan SZ
    Clin Nucl Med, 2024 Mar 01;49(3):250-252.
    PMID: 38306377 DOI: 10.1097/RLU.0000000000005037
    A 57-year-old woman received radioiodine therapy post total thyroidectomy for pT3aNxMx follicular thyroid carcinoma. Posttherapy 131I whole-body scan showed 131I concentration in the chest, mediastinum, and left upper thigh with stimulated thyroglobulin (Tg) of 89 μg/L. Subsequent radioiodine therapies showed persistent 131I accumulation in the anterior mediastinal soft tissue lesions and a hypodense segment VII liver lesion visualized on SPECT/CT, suggestive of iodine-avid metastatic disease despite the undetectable serum Tg (<1.0 μg/L) with no Tg antibody interference. Biopsy of the liver lesion revealed liver cyst, and consequent removal of the mediastinal lesions showed benign thymic cysts.
    Matched MeSH terms: Iodine Radioisotopes/therapeutic use
  13. Kolo MT, Aziz SA, Khandaker MU, Asaduzzaman K, Amin YM
    Environ Sci Pollut Res Int, 2015 Sep;22(17):13127-36.
    PMID: 25925148 DOI: 10.1007/s11356-015-4577-5
    Understanding the public awareness concerning the Lynas Advanced Material Plant (LAMP), an Australian rare earths processing plant located in Malaysia, a radiological study in soil and water samples collected at random surrounding the LAMP environment was undertaken using HPGe gamma-ray spectrometry. The mean soil activities for (226)Ra, (232)Th, and (40)K were found to be 6.56 ± 0.20, 10.62 ± 0.42, and 41.02 ± 0.67 Bq/kg, respectively, while for water samples were 0.33 ± 0.05, 0.18 ± 0.04, and 4.72 ± 0.29 Bq/l, respectively. The studied areas show typical local level of radioactivity from natural background radiation. The mean gamma absorbed dose rate in soils at 1 m above the ground was found to be 11.16 nGy/h. Assuming a 20 % outdoor occupancy factor, the corresponding annual effective dose showed a mean value of 0.014 mSv year(-1), significantly lower than the worldwide average value of 0.07 mSv year(-1) for the annual outdoor effective dose as reported by UNSCEAR (2000). Some other representative radiation indices such as activity utilization index (AUI), H ex, H in, excess lifetime cancer risk (ELCR), and annual gonadal dose equivalent (AGDE) were derived and also compared with the world average values. Statistical analysis performed on the obtained data showed a strong positive correlation between the radiological variables and (226)Ra and (232)Th.
    Matched MeSH terms: Potassium Radioisotopes/analysis*
  14. Aziz Saleh M, Termizi Ramli A, Alajerami Y, Damoom M, Sadiq Aliyu A
    Isotopes Environ Health Stud, 2014;50(1):103-13.
    PMID: 24279290 DOI: 10.1080/10256016.2013.821469
    The radiation survey of the ambient environment was conducted using two gamma detectors, and the measurement results were used in the computation of the mean external radiation dose rate, mean-weighted dose rate and annual effective dose, which are 144 nGy h(-1), 0.891 mSv y(-1) and 178 μSv, respectively. A high-purity germanium detector was used to determine the activity concentrations of (232)Th, (226)Ra and (40)K in soil samples. The results of the gamma spectrometry of the soil samples show radioactivity concentration ranges from 19±1 to 405±13 Bq kg(-1) with a mean value of 137±5 Bq kg(-1) for (232)Th, from 21±2 to 268±9 Bq kg(-1)with a mean value of 78±3 Bq kg(-1) for (226)Ra and from 23±9 to 1268±58 Bq kg(-1) with a mean value of 207±13 Bq kg(-1) for (40)K. Radium equivalent activity (Raeq) and external hazard index (Hex) were 290 Bq kg(-1) and 0.784, respectively, which were safe for the population. The mean lifetime dose and lifetime cancer risk for each person living in the area with average lifetime (70 y) were 12.46 mSv and 7.25×10(-4) Sv year, respectively. The results were compared with values given in United Nations Scientific Committee on the Effects of Atomic Radiation 2000.
    Matched MeSH terms: Potassium Radioisotopes/analysis
  15. Alnour IA, Wagiran H, Ibrahim N, Hamzah S, Elias MS, Laili Z, et al.
    Radiat Prot Dosimetry, 2014 Jan;158(2):201-7.
    PMID: 23965286 DOI: 10.1093/rpd/nct206
    The distribution of natural radionuclides ((238)U, (232)Th and (40)K) and their radiological hazard effect in rocks collected from the state of Johor, Malaysia were determined by gamma spectroscopy using a high-purity germanium detector. The highest values of (238)U, (232)Th and (40)K activity concentrations (67±6, 85±7 and 722±18 Bg kg(-1), respectively) were observed in the granite rock. The lowest concentrations of (238)U and (232)Th (2±0.1 Bq kg(-1) for (238)U and 2±0.1 Bq kg(-1) for (232)Th) were observed in gabbro rock. The lowest concentration of (40)K (45±2 Bq kg(-1)) was detected in sandstone. The radium equivalent activity concentrations for all rock samples investigated were lower than the internationally accepted value of 370 Bq kg(-1). The highest value of radium equivalent in the present study (239±17 Bq kg(-1)) was recorded in the area of granite belonging to an acid intrusive rock geological structure. The absorbed dose rate was found to range from 4 to 112 nGy h(-1). The effective dose ranged from 5 to 138 μSv h(-1). The internal and external hazard index values were given in results lower than unity. The purpose of this study is to provide information related to radioactivity background levels and the effects of radiation on residents in the study area under investigation. Moreover, the relationships between the radioactivity levels in the rocks within the geological structure of the studied area are discussed.
    Matched MeSH terms: Potassium Radioisotopes/analysis*
  16. Maxwell O, Wagiran H, Ibrahim N, Lee SK, Sabri S
    Radiat Prot Dosimetry, 2013 Dec;157(2):271-7.
    PMID: 23754832 DOI: 10.1093/rpd/nct140
    The purpose of this project is to evaluate the suitability of different sites as locations for obtaining underground water for consumption. The analysis of ²³⁸U, ²³²Th and ⁴⁰K from rock samples from each layer of borehole at a depth of ∼50 m at Site A borehole, S3L1-S3L6 in Gosa and 40 m at Site B borehole, S4L1-S4L5 in Lugbe, Abuja, north central Nigeria is presented. The gamma-ray spectrometry was carried out using a high-purity germanium detector coupled to a computer-based high-resolution multichannel analyzer. The activity concentrations at Site A borehole for ²³⁸U have a mean value of 26 ± 3, ranging from 23 ± 2 to 30 ± 3 Bq kg⁻¹, ²³²Th a mean value of 63 ± 5, ranging from 48 ± 4 to 76 ± 6 Bq kg⁻¹ and ⁴⁰K a mean value of 573 ± 72, ranging from 437 ± 56 to 821 ± 60 Bq kg⁻¹. The activity concentrations at Site B borehole for ²³⁸U have a mean value of 20 ± 2, ranging from 16 ± 2 to 23 ± 2 Bq kg⁻¹, ²³²Th a mean value of 46 ± 4, ranging from 43 ± 4 to 49 ± 4 Bq kg⁻¹, ⁴⁰K a mean value of 915 ± 116 and ranging from 817 ± 103 Bq kg⁻¹ to 1011 ± 128 Bq kg⁻¹. It is noted that the higher activity concentrations of ²³²Th and ²³⁸U are found in Site A at Gosa. Site B has lower radioactivity, and it is recommended that both sites are suitable for underground water consumption.
    Matched MeSH terms: Potassium Radioisotopes/analysis*
  17. Saleh MA, Ramli AT, Alajerami Y, Aliyu AS
    J Environ Radioact, 2013 Oct;124:130-40.
    PMID: 23727880 DOI: 10.1016/j.jenvrad.2013.04.013
    Extensive environmental survey and measurements of gamma radioactivity in the soil samples collected from Segamat District were conducted. Two gamma detectors were used for the measurements of background radiation in the area and the results were used in the computation of the mean external radiation dose rate and mean weighted dose rate, which are 276 nGy h(-1) and 1.169 mSv y(-1), respectively. A high purity germanium (HPGe) detector was used in the assessment of activity concentrations of (232)Th, (226)Ra and (40)K. The results of the gamma spectrometry range from 11 ± 1 to 1210 ± 41 Bq kg(-1) for (232)Th, 12 ± 1 to 968 ± 27 Bq kg(-1) for (226)Ra, and 12 ± 2 to 2450 ± 86 Bq kg(-1) for (40)K. Gross alpha and gross beta activity concentrations range from 170 ± 50 to 4360 ± 170 Bq kg(-1) and 70 ± 20 to 4690 ± 90 Bq kg(-1), respectively. These results were used in the plotting of digital maps (using ARCGIS 9.3) for isodose. The results are compared with values giving in UNSCEAR 2000.
    Matched MeSH terms: Potassium Radioisotopes/analysis*
  18. Asaduzzaman K, Mannan F, Khandaker MU, Farook MS, Elkezza A, Amin YB, et al.
    PLoS One, 2015;10(10):e0140667.
    PMID: 26473957 DOI: 10.1371/journal.pone.0140667
    The concentrations of primordial radionuclides (226Ra, 232Th and 40K) in commonly used building materials (brick, cement and sand), the raw materials of cement and the by-products of coal-fired power plants (fly ash) collected from various manufacturers and suppliers in Bangladesh were determined via gamma-ray spectrometry using an HPGe detector. The results showed that the mean concentrations of 226Ra, 232Th and 40K in all studied samples slightly exceeded the typical world average values of 50 Bq kg(-1), 50 Bq kg(-1) and 500 Bq kg(-1), respectively. The activity concentrations (especially 226Ra) of fly-ash-containing cement in this study were found to be higher than those of fly-ash-free cement. To evaluate the potential radiological risk to individuals associated with these building materials, various radiological hazard indicators were calculated. The radium equivalent activity values for all samples were found to be lower than the recommended limit for building materials of 370 Bq kg(-1), with the exception of the fly ash. For most samples, the values of the alpha index and the radiological hazard (external and internal) indices were found to be within the safe limit of 1. The mean indoor absorbed dose rate was observed to be higher than the population-weighted world average of 84 nGy h(-1), and the corresponding annual effective dose for most samples fell below the recommended upper dose limit of 1 mSv y(-1). For all investigated materials, the values of the gamma index were found to be greater than 0.5 but less than 1, indicating that the gamma dose contribution from the studied building materials exceeds the exemption dose criterion of 0.3 mSv y(-1) but complies with the upper dose principle of 1 mSv y(-1).
    Matched MeSH terms: Potassium Radioisotopes/analysis*
  19. Hassan H, Bakar SA, Halim KN, Idris J, Saad FF, Nordin AJ
    Curr Radiopharm, 2016;9(2):121-7.
    PMID: 26239237
    BACKGROUND AND OBJECTIVE: 18F-Fluorocholine has been suggested as one of the reputable imaging tracers for diagnosis of prostate tumour in Positron Emission Tomography / Computed Tomography (PET/CT) modality. Nevertheless, it has never been synthesised in Malaysia. We acknowledged that the major problem with 18F-Fluorocholine is due to its relatively low radiochemical yield at the end of synthesis (EOS). Therefore, this article presents improved 18FFluorocholine radiochemical yields after carrying out optimisation on azeotropic drying of 18F-Fluorine.

    METHODS: In the previous study, the azeotropic drying of non-carrier-added (n.c.a) 18F-Fluorine in the reactor was conducted at atmospheric pressure (0 atm) and shorter duration time. In this study, however, the azeotropic drying of non-carried-added (n.c.a) 18FFluorine was made at a high vacuum pressure (- 0.65 to - 0.85 bar) with an additional time of 30 seconds. At the end of the synthesis, the mean radiochemical yield was statistically compared between the two azeotropic drying conditions so as to observe whether the improvement made was significant to the radiochemical yield.

    RESULTS: From the paired sample t-test analysis, the improvement done to the azeotropic drying of non-carrier-added (n.c.a) 18F-Fluorine was statistically significant (p < 0.05). With the improvement made, the 18F-Fluorcholine radiochemical yield was found to have increase by one fold.

    CONCLUSION: Improved 18F-Fluorocholine radiochemical yields were obtained after the improvement had been done to the azeotropic drying of non-carrier-added (n.c.a) 18F-Fluorine. It was also observed that improvement made to the azeotropic drying of non-carrier-added (n.c.a) 18F-Fluorine did not affect the 18F-Fluorocholine quality control analysis.

    Matched MeSH terms: Fluorine Radioisotopes/chemistry*
  20. Entezam A, Fielding A, Bradley D, Fontanarosa D
    PLoS One, 2023;18(2):e0280765.
    PMID: 36730280 DOI: 10.1371/journal.pone.0280765
    Computed tomography (CT) derived Monte Carlo (MC) phantoms allow dose determination within small animal models that is not feasible with in-vivo dosimetry. The aim of this study was to develop a CT-derived MC phantom generated from a mouse with a xenograft tumour that could then be used to calculate both the dose heterogeneity in the tumour volume and out of field scattered dose for pre-clinical small animal irradiation experiments. A BEAMnrc Monte-Carlo model has been built of our irradiation system that comprises a lead collimator with a 1 cm diameter aperture fitted to a Cs-137 gamma irradiator. The MC model of the irradiation system was validated by comparing the calculated dose results with dosimetric film measurement in a polymethyl methacrylate (PMMA) phantom using a 1D gamma-index analysis. Dose distributions in the MC mouse phantom were calculated and visualized on the CT-image data. Dose volume histograms (DVHs) were generated for the tumour and organs at risk (OARs). The effect of the xenographic tumour volume on the scattered out of field dose was also investigated. The defined gamma index analysis criteria were met, indicating that our MC simulation is a valid model for MC mouse phantom dose calculations. MC dose calculations showed a maximum out of field dose to the mouse of 7% of Dmax. Absorbed dose to the tumour varies in the range 60%-100% of Dmax. DVH analysis demonstrated that tumour received an inhomogeneous dose of 12 Gy-20 Gy (for 20 Gy prescribed dose) while out of field doses to all OARs were minimized (1.29 Gy-1.38 Gy). Variation of the xenographic tumour volume exhibited no significant effect on the out of field scattered dose to OARs. The CT derived MC mouse model presented here is a useful tool for tumour dose verifications as well as investigating the doses to normal tissue (in out of field) for preclinical radiobiological research.
    Matched MeSH terms: Cesium Radioisotopes*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links